Effects of Change in Heat Release Rate on Unsteady Fire Characteristics in a Semi-Closed Compartment (반밀폐된 구획에서 발열량 변화에 따른 비정상 화재특성)

  • Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.75-83
    • /
    • 2012
  • An experimental study was conducted to investigate the effects of change in heat release rate on unsteady fire characteristics of under-ventilated fire in a semi-closed compartment. A standard doorway width of the full-scale ISO 9705 room was modified to 0.1 m and the flow rate of heptane fuel was increased linearly with time using a spray nozzle located at the center of enclosure. Temperature, heat flux, species concentrations and heat release rate were continuously measured and then global equivalence ratio (GER) concept was adopted to represent the unsteady thermal and chemical characteristics inside the compartment. It was observed that there was a significant difference in unsteady behavior between global and local combustion efficiency, and the GERs predicted by ideal and measured heat release rate were also shown different results in time. The unsteady behaviors of temperature, heat flux and species concentrations were represented well using the GER concept. It was important to note that CO concentration was gradually decreased with the increase in GER after reaching its maximum value in the range of 2.0~3.0 of global equivalence ratio. In addition, the experimental data on unsteady thermal and chemical behaviors obtained in a semi-closed compartment will be usefully used to validate a realistic fire simulation.

Experimental and Numerical Studies on the Failure of Curtain Wall Double Glazed for Radiation Effect (커튼월 이중 유리 외장재 파단에 대한 실험 및 수치해석 연구)

  • Nam, Jiwoo;Ryou, Hong-Sun;Kim, Dong-Joon;Kim, Sung-Won;Nam, Jun-Seok;Cho, Seongwook
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.40-44
    • /
    • 2015
  • National and international standards for curtain wall glass are focused on wind pressure and insulation performance, but disasters such as fires and earthquakes are not considered. Failure of curtain wall glass during a fire in a skyscraper increases the loss of lives and property due to the spread of fire. Therefore, the fire resistance of curtain wall glass should be investigated, and technology to prevent glass failure should be developed to prevent fire damage due to spreading fire. It is important to predict the starting point of cracks and the cause of glass failure to prevent it effectively using the limited water in a skyscraper. In this study, double glazed glass was exposed to a radiator in an experiment performed to analyze the thermal characteristics. The results show that glass that was not directly exposed to high temperature and pressure was broken. To identify this failure case, numerical analysis was performed. Three glass specimens were installed in an ISO 9705 room and exposed to radiation using a radiator, and a thermocouple was used to measure the temperature on the surface of the glass. Widely used double glazed glass was analyzed for weakness to fire.

Effects of Ventilation Condition on the Fire Characteristics in Compartment Fires (Part I: Performance Estimation of FDS) (구획화재에서 환기조건의 변화가 화재특성에 미치는 영향(Part I: FDS의 성능평가))

  • Hwang, Cheol-Hong;Park, Chung-Hwa;Ko, Gwon-Hyun;Lock, Andrew
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.131-138
    • /
    • 2010
  • Experimental and numerical studies were conducted to investigate the thermal and chemical characteristics of heptane fires in a full-scale ISO 9705 room. Representative fire conditions were considered for over-ventilated fire (OVF) and under-ventilated fire (UVF). Fuel flow rate and doorway width were changed to create OVF and UVF conditions. Detailed comparisons of temperature and species concentrations between experimental and numerical data were presented in order to validate the predictive performance of FDS (Fire Dynamic Simulator). The OVF and UVF were explicitly characterized with distributions of temperature and product formation measured in the upper layer, as well as combustion efficiency and global equivalence ratio. It was shown that the numerical results provided a quantitatively realistic prediction of the experimental results observed in the OVF conditions. For the UVF, the numerically predicted temperature showed reasonable agreement with the measured temperature. The predicted steady-state volume fractions of $O_2$, $CO_2$, CO and THC also agreed quantitatively with the experimental data. Although there were some limitations to predict accurately the transient behavior in terms of CO production/consumption in the UVF condition, it was concluded that the current FDS was very useful tool to predict the fire characteristics inside the compartment for the OVF and UVF.

A Correlation Study for the Prediction of the Maximum Heat Release Rate in Closed-Compartments of Various Configurations (다양한 형상의 밀폐된 구획에서 최대 열발생률 예측을 위한 상관식 검토)

  • Yun, Hong-Seok;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.16-23
    • /
    • 2018
  • In a closed-compartment with various configurations, the correlation that can predict the maximum heat release rate (HRR) with the changes in internal volume and fire growth rate was investigated numerically. The volume of the compartment was controlled by varying the length ratio based on the bottom surface shape of the ISO 9705 fire room, where the ceiling height was fixed to 2.4 m. As a main result, the effect of a change in ceiling height on the maximum HRR was examined by a comparison with a previous study that considered the change in ceiling height. In addition, a more generalized correlation equation was proposed that could predict the maximum HRR in closed-compartments regardless of the changes in ceiling height. This correlation had an average error of 7% and a maximum error of 19% for various fire growth rates when compared with the numerical results. Finally, the applicability of the proposed correlation to representative fire compartments applied to the domestic performance-based design (PBD) was examined. These results are expected to provide useful information on predicting the maximum HRR caused by flashover in closed-compartments as well as the input information required in a fire simulation.

A Study of a Heat Flux Mapping Procedure to Overcome the Limitation of Heat Flux Gauges in Fire Tests (화재실험시 열유속 센서 사용의 단점을 보완한 Heat Flux Mapping Procedure에 관한 연구)

  • Choi, Keum-Ran
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.4 s.72
    • /
    • pp.171-179
    • /
    • 2005
  • It is essential to understand the role of wall lining materials when they are exposed to a fire from an ignition source. Full-scale test methods permit an assessment of the performance of a wall lining material. Fire growth models have been developed due to the costly expense associated with full-scale testing. The models require heat flux maps from the ignition burner flame as input data. Work to date was impeded by a lack of detailed spatial characterization of the heat flux maps due to the use of limited instrumentation. To increase the power of fire modeling, accurate and detailed heat flux maps from the ignition burner are essential. High level spatial resolution for surface temperature can be provided from an infrared camera. The objective of this study was to develop a heat flux mapping procedure for a room test burner flame to a wall configuration with surface temperature information taken from an infrared camera. A prototype experiment was performed using the ISO 9705 test burner to demonstrate the developed heat flux mapping procedure. The results of the experiment allow the heat flux and spatial resolutions of the method to be determined and compared to the methods currently available.

An Experimental Study on Relationship Between Global Equivalence Ratio and Fire Characteristics in Full-Scale Compartment Fires (실제 규모의 구획화재에서 총괄당량비와 화재특성의 상관관계에 관한 실험적 연구)

  • Hwang, Cheol-Hong;Park, Chung-Hwa;Ko, Gwon Hyun;Lock, Andrew
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.3
    • /
    • pp.32-39
    • /
    • 2010
  • An experimental study was conducted to investigate the relationship between global equivalence ratio(GER) and fire characteristics in an ISO 9705 room. Heptane fuel was burned with different fuel flow rates and doorway widths in order to force the room to be placed in different GER conditions. It was observed that after the onset of under-ventilated fire conditions, temperature and unburned fuel components such as CO and soot increased with increasing heat release rate (HRR), regardless of the doorway width. From the analysis of local mixture fraction, it was reconfirmed that the inclusion of soot production in the product composition was very important to predict accurately the chemical conditions inside the compartment, particularly for the under-ventilated fire conditions. In addition, the local equivalence ratio (LER) was directly proportional to the GER with a unit gradient regardless of doorway width when the soot production was included in the chemical products. This finding provided an important potential that the GER could be used to correlate the local thermal and chemical environment measured at the upper layer of a full-scale enclosure when soot was included.

Effect of the Characteristic Length Scale on the Grid Dependency of FDS model (특성길이에 따른 FDS 모델의 격자 의존성)

  • Kim, Sung-Chan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.66-69
    • /
    • 2012
  • Field Model에 의한 화재해석방법은 화재현상을 지배하는 망정식윤 직접 해석하기 때문에 Zone model에 비해 공간내의 상세 정보를 제공함과 동시에 다양한 화재형태에 내해 보편적인 적용이 가능하다. Field model은 해석영역을 구성하는 격자점에 대해 이산화된 지배 방정식을 해석하는 과정에서 차분방법이나 격자의 크기에 따라 수치오류가 발생할 수 있다. 특히 격자수는 계산시간에 영향을 미치는 가장 중요한 인자이기 때문에 효율적인 계산을 위해서는 격자크기의 최적화가 이루어져야 한다. 본 연구에서는 구획공간 화재의 최적 격자크기 선정을 위해 격자해상도(Grid Resolution)에 따른 해석결과의 독립성을 비교분석하고 이를 통해 구획공간화재에 대한 격자 최적화 방법에 대해 논의하고자 한다. 화재크기 및 특성 길이에 따른 격자의존성을 파악하기 위해 ISO-9705 표준화재실에 내해 적용된 격자크기는 최소 3 cm에서 최대 30 cm까지 총 7 종류의 격자크기에 대해 FDS 해석이 수행되었다. 해석결과, 환기량이 충분한 화재에 대해서도 격자해상도가 16보다 작은 경우 출입구의 유동은 격자에 따른 독립성을 확보하지 못하는 것으로 나타났으며 화재발열량이 증가함에 따라 독립적인 해석해를 얻기 위해서는 더 큰 격자해상도를 요구하는 것으로 나타났다. 따라서 현재 실무에서 격자최적화를 위해 사용되고 있는 격자선정법에 대한 재검토가 필요하며 화재특성 및 구획공간 조건에 따른 최적격자 조건을 도출하기 위한 추가적인 연구가 필요하다.

  • PDF

An Evaluation of FDS for Predicting the Unsteady Fire Characteristics in a Semi-Closed Compartment (반밀폐된 구획에서 비정상 화재특성 예측을 위한 FDS의 평가)

  • Hwang, Cheol-Hong;Mun, Sun-Yeo;Park, Chung-Hwa;Kim, Jong-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.3-6
    • /
    • 2011
  • 비정상(unsteady) 화재성장이 발생되는 반밀폐된 구획에서 환기부족화재의 열 및 화학적 특성에 관한 FDS(Fire Dynamics Simulator)의 예측성능 평가가 수행되었다. 이를 위해 실규모 ISO 9705 표준 화재실의 출입구 폭이 0.1m로 축소되었으며, spray 노즐을 통해 Heptane 연료유량은 선형적으로 증가되었다. 수치계산에 대한 신뢰도 확보를 위하여 동일조건에서 수행된 실험결과와의 상세한 비교가 이루어졌다. 적절한 격자계를 이용한 FDS의 결과는 구획 내부의 온도 및 열유속(heat flux)은 비교적 잘 예측하지만, 비정상 CO 및 $CO_2$ 생성특성은 적절히 예측하지 못함을 확인하였다. 이러한 결과는 최근 수행된 유사조건의 정상상태 환기부족 구획화재에 대한 FDS 예측결과와 상반된 것으로서, 반밀폐된 구획화재 모델링에서 FDS를 이용한 비정상 CO 생성특성 예측에 상당한 주위가 요구됨을 확인하였다.

  • PDF

Multi-dimensional Fire Behaviors in an Under-ventilated Compartment Fire (환기부족 구획화재에서 다차원 화재거동)

  • Hwang, Cheol-Hong;Park, Chung-Hwa;Ko, Gwon-Hyun;Lock, Andrew
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.37-42
    • /
    • 2010
  • 실제 규모 ISO 9705 표준 화재실에서 과환기(over-ventilated) 및 환기부족(under-ventilated) 화재에 대한 열 및 화학적 특성에 관한 실험이 수행되었다. 또한 FDS(Fire Dynamic Simulator)를 이용하여 수치적 예측성능에 대한 평가와 환기부족화재에서 건물 내부의 다차원 화재현상에 대한 해석이 이루어졌다. 과환기 및 환기부족화재의 특성은 연소효율, 총괄 당량비 뿐만 아니라 고온 상층부의 온도분포, 연소 생성물의 농도에 의해 명확하게 구분되었다. 실험결과와의 비교를 통해 과환기 및 환기부족화재에서 FDS는 공간내부의 온도, 열유속 및 다양한 화학종의 분포를 정량적으로 잘 예측함을 확인하였다. 과환기화재와 비교할 때, 환기부족화재에서 내부유동은 반대방향의 다차원 재순환 유동구조를 갖고 있음을 발견하였다. 동시에 공간내부의 $O_2$ 및 CO의 분포 역시 다차원 구조를 갖기 때문에 기존화재연구에서 측정되는 고온 상층부의 열 및 화학적 특성은 환기부족화재를 이해하는데 많은 한계가 있음을 확인하였다.

  • PDF

Thermal Characteristics of Under Ventilated Compartment Fire (환기부족 구획화재의 열적 특성)

  • Kim, Sung-Chan;Hamins, Anthony
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.41-48
    • /
    • 2009
  • The present study has been performed to investigate the thermal characteristics of under-ventilated compartment fire which is a typical fire condition in structures. A series of fire experiments was conducted to characterize the thermally driven flow in a 2/5 scale ISO 9705 fire compartment. Three different fuels were used in this test series, methane gas, heptane pool, and polystyrene pellets fire. In order to measure accurate temperature, double shield aspirated thermocouples reducing the effect of radiative energy exchange on temperature measurement were used in addition to bare bead thermocouples. The upper layer temperature for well ventilated fire was increased with increasing heat release rate, but it was slightly decreased for under-ventilated fire. The measured temperatures in the upper layer at the front sampling location were higher than at the rear. Thermal characteristics through the doorway were also analysed for a wide range of heat release rates. This study provides a comprehensive and quantitative assessment of fire behavior for under-ventilation condition of fire.