• Title/Summary/Keyword: IS-801

Search Result 514, Processing Time 0.023 seconds

Dynamic Thresholding Scheme for Fingerprint Identification (지문 식별을 위한 동적 임계치 설정방법)

  • Kim, Kyoung-Min;Lee, Buhm;Park, Joong-Jo;Jung, Soon-Won
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.9
    • /
    • pp.801-805
    • /
    • 2012
  • This paper proposes dynamic thresholding scheme for fingerprint identification. As a user authentication method by fingerprint recognition technology, verification method based on 1:1 matching was mainly used in the past, but identification method based on 1:N matching is generally used recently. The control of the value of FAR is very important in the application areas such as access control and time attendance systems. This paper proposes dynamic thresholding scheme which could properly control the value of FAR according to the field of applications and size of the fingerprints database.

A Study of Nanoscale Structure of Anodic Porous Alumina film (다공성 알루미나 박막의 나노 스케일 구조에 관한 연구)

  • 정경한;신훈규;권영수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.9
    • /
    • pp.801-806
    • /
    • 2003
  • In recent years, there has been large interest in the fabrication of the self organized nanoscale structures since not only their potential utilization in electronic, optoelectronic, and magnetic devices but also their fundamental interest such as uniformity and regularization. An attractive candidate of these materials is anodic porous alumina film(Al$_2$O$_3$) which is formed by the anodization of aluminum in an appropriate acid solution. In this study to fabricate the porous alumina film with very uniform and nearly parallel pores the anodization was carried out under constant voltage mode in 0.3M oxalic acid as an electrolyte. The hexagonally ordered arrays with a few $\mu\textrm{m}$ in size two-dimensional polycrystalline structure were obtained of which pore densities were 1.1${\times}$10$\^$10//$\textrm{cm}^2$.

Vulnerability assessment and retrofit solutions of precast industrial structures

  • Belleri, Andrea;Torquati, Mauro;Riva, Paolo;Nascimbene, Roberto
    • Earthquakes and Structures
    • /
    • v.8 no.3
    • /
    • pp.801-820
    • /
    • 2015
  • The seismic sequence which hit the Northern Italian territory in 2012 produced extensive damage to reinforced concrete (RC) precast buildings typically adopted as industrial facilities. The considered damaged buildings are constituted by one-storey precast structures with RC columns connected to the ground by means of isolated socket foundations. The roof structural layout is composed of pre-stressed RC beams supporting pre-stressed RC floor elements, both designed as simply supported beams. The observed damage pattern, already highlighted in previous earthquakes, is mainly related to insufficient connection strength and ductility or to the absence of mechanical devices, being the connections designed neglecting seismic loads or neglecting displacement and rotation compatibility between adjacent elements. Following the vulnerabilities emerged in past seismic events, the paper investigates the seismic performance of industrial facilities typical of the Italian territory. The European building code seismic assessment methodologies are presented and discussed, as well as the retrofit interventions required to achieve an appropriate level of seismic capacity. The assessment procedure and retrofit solutions are applied to a selected case study.

Analysis of Electric Field Distribution and Characteristics of Volume Resistivity in HDPE/EVA Film for Recycling (재활용을 고려한 HDPE/EVA필름의 전계분포 및 체적저항특성 해석)

  • Lee, Hung-Kyu;Lim, Kee-Joe;Kim, Yong-Joo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.9
    • /
    • pp.801-807
    • /
    • 2008
  • Recently, CV, CN-CV and CNCV-W cable are used for HVDC transmission and distribution cable. However, XLPE which is used as insulation layer of power cable has thermosetting properties. It is very difficult to recycling. In this paper, we prepared HDPE/EVA film, which the blending ratio are 80:20, 70:30, 60:40, 50;50 respectively for the purpose of recycling. Main factor such as electric field distribution and its resistivity in insulation system affected on insulation performance and reliability for HVDC applications. Therefore, electric field distribution formed by space charge and characteristics of volume resistivity was currently investigated. We suggest the possibility of utilization for HVDC insulation layer from the results.

Effect of NMDA Receptor on Analgesic Effect of Bovine Milk-derived Lactoferrin (BLF) (우유속 락토페린의 NMDA 수용체를 통한 진통효과)

  • Jeon, Yong-Joon;Yun, Jae-Suk;Lim, Hwa-Kyung;Park, Ki-Suk;Na, Han-Kang;Kim, Dong-Sup;Kim, Joo-il;Yoon, Yea-Chang;Choi, Ki Hwan
    • YAKHAK HOEJI
    • /
    • v.49 no.5
    • /
    • pp.370-374
    • /
    • 2005
  • Lactoferrin is a multifunctional protein that is found in milk, neutrophils, and other biological fluids, and its receptors have also been identified in the central nervous system. Recently, it was reported that bovine milk-derived lacto­ferrin (BLF) produced analgesia via a $\mu$-opioid receptor-mediated response in the spinal cord. However the precise mech­anism of this analgesic effect is remains unclear. In Randall-Selitto paw pressure study, each single administration of morphine (10 mg/kg) and BLF (50, 100 and 200 mg/kg) induced analgesia, however, NMDA receptor antagonist MK-801 (0.1, 0.2 and 0.3 mg/kg), inhibited analgesia induced by BLF (100 mg/kg). Intracerebroventricular infusion (I.C.V.) of N­methyl-D-aspartic acid (NMDA) ($0.3\;{\mu}g/8.0\;{\mu}l/hr/day$), as a NMDA receptor agonist, reversed inhibition of MK-801 (0.3 mg/kg) on analgesia induced by BLF (100 mg/kg). These results suggest that BLF have analgesic effect, through NMDA recep­tor activation.

Understanding of dynamic system properties in the frequency domain using bond graphs (본드선도를 이용한 동적시스템의 주파수역 특성이해)

  • Park, Jeon-Soo;Kim, Jong-Shik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.4
    • /
    • pp.801-810
    • /
    • 1998
  • Modeling and analysis of dynamic systems generally demand their resutls to be interpreted each other with a physical sense. It sometimes requires that there should exist a unified tool in the treatment of dynamic systems which can be applied to both their modeling and analysis equally. This paper shows how models just after the progress of modeling via bond graph standards are converted to ones which are appropriate for analyzing a dynamic system in the frequency domain. Four bond graph prototypes are introduced to obtain frequency properties of dynamic systems such as zero stability, relative order, zero and pole dynamics, etc. directly from bond graphs, and the method are proposed which reduces nearly all models of bond graph standards to one of the prototypes without any change of physical similarity. This procedure as a tool for the structural reduction of bond graphs and finding frequency properties of a dynamic system is further investigated to survey its effectiveness through an example.

Long-term Change in Sea Level along the Eastern Coastal Waters of Korea using Tide Gauge, Water Temperature and Salinity (조위 및 수온, 염분 데이터를 이용한 동해 연안의 해수면 변화)

  • Park, Se-Young;Lee, Chung-Il
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.801-806
    • /
    • 2014
  • Long-term change in sea level along the eastern coast of Korea was illustrated using four tide-gauge station (Pohang, Mukho, Sokcho, Ulleung) data, water temperature and salinity. Seasonal variation in the sea level change was dominant. The sea level change by steric height derived from water temperature and salinity was relatively lower than that measured from the tide-gauge stations. Sea level rising rate per year by steric height increased with latitude. The effect of salinity(water temperature) on the sea level change is greater in winter(in summer).

Experiment of single screw piles under inclined cyclic pulling loading

  • Dong, Tian Wen;Zheng, Ying Ren
    • Geomechanics and Engineering
    • /
    • v.8 no.6
    • /
    • pp.801-810
    • /
    • 2015
  • The ultimate pullout capacity under inclined dynamic loading is an important measure of the destruction degree of vertical screw piles (anchors) under dynamic actions. Based on the static and dynamic tests on two kinds of model screw piles, the ultimate bearing capacity was researched considering different distance-width ratio of blade (D/W) and preloading ratio. The results compared well with other experimental data available in the literature. This research reveals that D/W might determine the failure model of the piles (anchors), for example D/W = 3.14 or 5; a critical dynamic-static loading ratio (DSLR) existed in the experiments. The critical DSLR was reached under the conditions of 40%~60% preloading (D/W = 3.14) or 20%~40% preloading (D/W = 5), respectively.

A CONSTRUCTION OF COMMUTATIVE NILPOTENT SEMIGROUPS

  • Liu, Qiong;Wu, Tongsuo;Ye, Meng
    • Bulletin of the Korean Mathematical Society
    • /
    • v.50 no.3
    • /
    • pp.801-809
    • /
    • 2013
  • In this paper, we construct nilpotent semigroups S such that $S^n=\{0\}$, $S^{n-1}{\neq}\{0\}$ and ${\Gamma}(S)$ is a refinement of the star graph $K_{1,n-3}$ with center $c$ together with finitely many or infinitely many end vertices adjacent to $c$, for each finite positive integer $n{\geq}5$. We also give counting formulae to calculate the number of the mutually non-isomorphic nilpotent semigroups when $n=5$, 6 and in finite cases.

The Flow Visualization of ER Fluid Between Two Parallel-Plate Electrodes Separated by Small Distance (좁은 평행평판전극 사이의 ER유체 유동의 가시화)

  • Park, Myeong-Kwan;Rhee, Eun-Jun;Oshima, Shuzo;Yamane, Ryuichiro
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.7
    • /
    • pp.801-810
    • /
    • 1999
  • The purpose of present research was to get characteristics and basic knowledges of electrorheological(ER) suspension. To observe behaviors of the ER suspensions. transparent conductive plates were used to visualize the flow of ER suspensions between two parallel plate electrodes. The influence of flowing speed and intensity of electric field on the ER fluid were examined in circle-shaped electric field, and it takes several hundred milliseconds that suspensions in flow cluster. The present study also conducts a numerical analysis adopting the Bingham model. It is found that simple Bingham model can not property describe the flow behavior in the parallel plates.