Usability Evaluation by Development of IRIS Type X-ray Collimator (조리개형 X선 콜리메이터의 개발에 따른 유용성 평가)

  • Kang, In-Seog;Park, Jae-Yoon;Lim, Cheong-Hwan;Choi, Jae-Ho;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.249-254
    • /
    • 2018
  • In this study, we evaluated the DAP(Dose Area Product) reduction effect of the newly developed IRIS collimator by measuring the DAP of the Rectangle collimator and the IRIS collimator depending on the field, SID(Source to Image recpetor Distance) change, and AEC mode use. The results were as follows. The IRIS collimator decreased DAP by 34.91, 29.33, and 29.04%, respectively, compared to the Rectangle collimator when the field was increased to $8{\times}8$, $12{\times}12$, $16{\times}16inch$. And also, when the SID was increased to 100, 120 and 140 cm, the IRIS collimator decreased DAP by 10.73, 33.68 and 46.22%, respectively, compared to the Rectangle collimator. In AEC mode and none-AEC mode, DAP in IRIS collimator was reduced by 32.71 and 21.69%, respectively, compared with the Rectangle type. The IRIS collimator can reduce DAP by 29.62% on average compared to Rectangle type, which is statistically significant. These results suggest that the newly developed IRIS collimator can be used in medical field to alleviate radiation exposure.

Development of the IRIS Collimator for the Portable Radiation Detector and Its Performance Evaluation Using the MCNP Code (IRIS형 방사선검출기 콜리메이터 제작 및 MCNP 코드를 이용한 성능평가)

  • Ji, Young-Yong;Chung, Kun Ho;Lee, Wanno;Choi, Sang-Do;Kim, Change-Jong;Kang, Mun Ja;Park, Sang Tae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.1
    • /
    • pp.55-61
    • /
    • 2015
  • When a radiation detector is applied to the measurement of the radioactivity of high-level of radioactive materials or the rapid response to the nuclear accident, several collimators with the different inner radii should be prepared according to the level of dose rate. This makes the in-situ measurement impractical, because of the heavy weight of the collimator. In this study, an IRIS collimator was developed so as to have a function of controlling the inner radius, with the same method used in optical camera, to vary the attenuation ratio of radiation. The shutter was made to have the double tungsten layers with different phase angles to prevent the radiation from penetrating owing to the mechanical tolerance. The performance evaluation through the MCNP code was conducted by calculating the attenuation ratio according to the inner radius of the collimator. The attenuation ratio was marked on the outer scale ring of the collimator. It is expected that when a radiation detector with the IRIS collimator is used for the in-situ measurement, it can change the attenuation ratio of the incident photon to the detector without replacing the collimator.