• 제목/요약/키워드: IR-Thermography

Search Result 60, Processing Time 0.036 seconds

Determination of an Test Condition for IR Thermography to Inspect a Wall-Thinning Defect in Nuclear Piping Components (원전 배관 감육 결함 검사를 위한 IR 열화상시험 조건 결정)

  • Kim, Jin-Weon;Yun, Won-Kyung;Jung, Hyun-Chul;Kim, Kyeong-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.12-19
    • /
    • 2012
  • This study conducted infrared (IR) thermography tests using pipe and plate specimens with artificial wall-thinning defects to find an optimal condition for IR thermography test on the wall-thinned nuclear piping components. In the experiment halogen lamp was used to heat the specimens. The distance between the specimen and the lamp and the intensity of halogen lamp were regarded as experimental parameter. When the distance was set to 1~2 m and the lamp intensity was above 60 % of full power, a single scanning of IR thermography detected all artificial wall-thinning defects, whose minimum dimension was $2{\Theta}=90^{\circ}$, d/t=0.5, and $L/D_o=0.25$, within the pipe of 500 mm in length. Regardless of the distance between the specimen and the lamp, the image of wall-thinning defect in IR thermography became distinctive as the intensity of halogen lamp increased. The detectability of IR thermography was similar for both plate and pipe specimens, but the optimal test condition for IR thermography depended on the type of specimen.

Damage detection of composite materials via IR thermography and electrical resistance measurement: A review

  • Park, Kundo;Lee, Junhyeong;Ryu, Seunghwa
    • Structural Engineering and Mechanics
    • /
    • v.80 no.5
    • /
    • pp.563-583
    • /
    • 2021
  • Composite materials, composed of multiple constituent materials with dissimilar properties, are actively adopted in a wide range of industrial sectors due to their remarkable strength-to-weight and stiffness-to-weight ratio. Nevertheless, the failure mechanism of composite materials is highly complicated due to their sophisticated microstructure, making it much harder to predict their residual material lives in real life applications. A promising solution for this safety issue is structural damage detection. In the present paper, damage detection of composite material via electrical resistance-based technique and infrared thermography is reviewed. The operating principles of the two damage detection methodologies are introduced, and some research advances of each techniques are covered. The advancement of IR thermography-based non-destructive technique (NDT) including optical thermography, laser thermography and eddy current thermography will be reported, as well as the electrical impedance tomography (EIT) which is a technology increasingly drawing attentions in the field of electrical resistance-based damage detection. A brief comparison of the two methodologies based on each of their strengths and limitations is carried out, and a recent research update regarding the coupling of the two techniques for improved damage detection in composite materials will be discussed.

ON-POWER DETECTION OF PIPE WALL-THINNED DEFECTS USING IR THERMOGRAPHY IN NPPS

  • Kim, Ju Hyun;Yoo, Kwae Hwan;Na, Man Gyun;Kim, Jin Weon;Kim, Kyeong Suk
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.225-234
    • /
    • 2014
  • Wall-thinned defects caused by accelerated corrosion due to fluid flow in the inner pipe appear in many structures of the secondary systems in nuclear power plants (NPPs) and are a major factor in degrading the integrity of pipes. Wall-thinned defects need to be managed not only when the NPP is under maintenance but also when the NPP is in normal operation. To this end, a test technique was developed in this study to detect such wall-thinned defects based on the temperature difference on the surface of a hot pipe using infrared (IR) thermography and a cooling device. Finite element analysis (FEA) was conducted to examine the tendency and experimental conditions for the cooling experiment. Based on the FEA results, the equipment was configured before the cooling experiment was conducted. The IR camera was then used to detect defects in the inner pipe of the pipe specimen that had artificially induced defects. The IR thermography developed in this study is expected to help resolve the issues related to the limitations of non-destructive inspection techniques that are currently conducted for NPP secondary systems and is expected to be very useful on the NPPs site.

The Effectiveness of Infrared Thermography in Patients with Whiplash Injury

  • Lee, Young Seo;Paeng, Sung Hwa;Farhadi, Hooman F.;Lee, Won Hee;Kim, Sung Tae;Lee, Kun Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.4
    • /
    • pp.283-288
    • /
    • 2015
  • Objective : This study aims to visualize the subjective symptoms before and after the treatment of whiplash injury using infrared (IR) thermography. Methods : IR thermography was performed for 42 patients who were diagnosed with whiplash injury. There were 19 male and 23 female patients. The mean age was 43.12 years. Thermal differences (${\Delta}T$) in the neck and shoulder and changes in the thermal differences (${\Delta}dT$) before and after treatment were analyzed. Pain after injury was evaluated using visual analogue scale (VAS) before and after treatment (${\Delta}VAS$). The correlations between ${\Delta}dT$ and ${\Delta}VAS$ results before and after the treatment were examined. We used Digital Infrared Thermal Imaging equipment of Dorex company for IR thermography. Results : The skin temperature of the neck and shoulder immediately after injury showed $1-2^{\circ}C$ hyperthermia than normal. After two weeks, the skin temperature was normal range. ${\Delta}T$ after immediately injuy was higher than normal value, but it was gradually near the normal value after two weeks. ${\Delta}dT$ before and after treatment were statistically significant (p<0.05). VAS of the neck and shoulder significantly reduced after 2 week (p=0.001). Also, there was significant correlation between ${\Delta}dT$ and reduced ${\Delta}VAS$ (the neck; r=0.412, p<0.007) (the shoulder; r=0.648, p<0.000). Conclusion : The skin temperature of sites with whiplash injury is immediately hyperthermia and gradually decreased after two weeks, finally it got close to normal temperature. These were highly correlated with reduced VAS. IR thermography can be a reliable tool to visualize the symptoms of whiplash injury and the effectiveness of treatment in clinical settings.

Multiple crack evaluation on concrete using a line laser thermography scanning system

  • Jang, Keunyoung;An, Yun-Kyu
    • Smart Structures and Systems
    • /
    • v.22 no.2
    • /
    • pp.201-207
    • /
    • 2018
  • This paper proposes a line laser thermography scanning (LLTS) system for multiple crack evaluation on a concrete structure, as the core technology for unmanned aerial vehicle-mounted crack inspection. The LLTS system consists of a line shape continuous-wave laser source, an infrared (IR) camera, a control computer and a scanning jig. The line laser generates thermal waves on a target concrete structure, and the IR camera simultaneously measures the corresponding thermal responses. By spatially scanning the LLTS system along a target concrete structure, multiple cracks even in a large scale concrete structure can be effectively visualized and evaluated. Since raw IR data obtained by scanning the LLTS system, however, includes timely- and spatially-varying IR images due to the limited field of view (FOV) of the LLTS system, a novel time-spatial-integrated (TSI) coordinate transform algorithm is developed for precise crack evaluation in a static condition. The proposed system has the following technical advantages: (1) the thermal wave propagation is effectively induced on a concrete structure with low thermal conductivity of approximately 0.8 W/m K; (2) the limited FOV issues can be solved by the TSI coordinate transform; and (3) multiple cracks are able to be visualized and evaluated by normalizing the responses based on phase mapping and spatial derivative processes. The proposed LLTS system is experimentally validated using a concrete specimen with various cracks. The experimental results reveal that the LLTS system successfully visualizes and evaluates multiple cracks without false alarms.

Test Research Using an IR Thermography Technique in a Supersonic Wind Tunnel (초음속 풍동에서의 IR Thermography 기법을 활용한 시험연구)

  • Kim, Ikhyun;Lee, Jaeho;Park, Gisu;Byun, Yunghwan;Lee, Jongkook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.2
    • /
    • pp.99-107
    • /
    • 2016
  • Test research on Infra-Red Thermography(IRT) technique in a supersonic wind tunnel has been conducted. Inadvertent technical difficulties and their solutions associated with the technique in running of the facility were examined. Two flow conditions at Mach number of 3 and 4 were considered. A double compression ramp model, that replicates realistic high-speed vehicle configuration, was used as test model. The present IR data were compared with shadowgraph visualization images and laminar computational fluid dynamics(CFD) results. It has been shown that the IRT technique can be used in quantifying various fluid dynamic features such as flow transition, separation and three-dimensional phenomena around the double compression ramp model.

Evaluation of Thermography Camera Using Molded Optical Lens for Medical Applications (몰드성형 광학렌즈를 이용한 의료기기용 열화상카메라 체열진단의 적용도 평가)

  • Ryu, Seong Mi;Kim, Hye-Jeong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.8
    • /
    • pp.624-628
    • /
    • 2013
  • With the recent development of less-costly uncooled detector technology, expensive optics are among the remaining significant cost drivers in the thermography camera. As a potential solution to this problem, the fabrication of IR lenses using chalcogenide glass has been studied in recent years. We report on the molding and evaluation of a ultra-precision chalcogenide-glass lens for the thermography camera for body-temperature monitoring. In addition, we fabricated prototype thermography camera using the chalcogenide-glass lens and obtained the thermal image from the camera. In this work, it was found out that thermography camera discerned body-temperature between 20 and $50^{\circ}C$ through the analysis of thermal image. It is confirmed that thermography camera using the chalcogenide-glass lens is applicable to the body-temperature monitoring system.

Development of UV-IR Camera using IR Module and Improved UV Filter Transmittance (투과율 향상 UV 필터와 IR 모듈을 이용한 자외선-적외선(UV-IR) 카메라 개발)

  • Kim, Young-Seok;Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Choi, Myeong-Il;Kim, Woo-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.37-43
    • /
    • 2012
  • UV-IR diagnostic technology is being used for predictive maintenance of high voltage equipment together with IR-thermography and ultrasonic devices. In this paper, the UV-IR camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. UV-IR camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. In a distance of 5m with the UV-IR it is possible to detect partial discharge with a PD level of 2.5 pC and a RIV(Radio Influence Voltage) level of $3.6dB{\mu}V$.

Tension Behavior of Nicalon/CAS Ceramic Composites (Nicalon/CAS 세라믹 복합재료의 인장특성)

  • Kim, Jeong-Guk;Kim, Weon-Kyong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.232-237
    • /
    • 2004
  • The tension behavior of Nicalon/CAS glass-ceramic matrix composites was investigated. Infrared (IR) thermography was employed for two different types of $Nicalon^{TM}/CAS$ composites, i.e., cross-ply and unidirectional specimens. During tensile testing, an IR camera was used for in-situ monitoring of progressive damages of $Nicalon^{TM}/CAS$ samples. The IR camera provided the temperature changes during tensile testing. Microstructural characterization using scanning electron microscopy (SEM) was performed to investigate the fracture mechanisms of $Nicalon^{TM}/CAS$ composites. In this investigation, the thermographic NDE technique was used to facilitate a better understanding of the fracture mechanisms of the $Nicalon^{TM}/CAS$ composites during tensile testing.

  • PDF