• Title/Summary/Keyword: IR-PTV

Search Result 2, Processing Time 0.017 seconds

Development and Validation of a Measurement Technique for Interfacial Velocity in Liquid-gas Separated Flow Using IR-PTV (적외선 입자추적유속계를 이용한 액체-기체 분리유동 시 계면속도 측정기법 개발 및 검증)

  • Kim, Sangeun;Kim, Hyungdae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.549-555
    • /
    • 2015
  • A measurement technique of interfacial velocity in air-water separated flow by particle tracking velocimetry using an infrared camera (IR-PTV) was developed. As infrared light with wavelength in the range of 3-5 um could hardly penetrate water, IR-PTV can selectively visualize only the tracer particles existing in depths less than 20 um underneath the air-water interface. To validate the measurement accuracy of the IR-PTV technique, a measurement of the interfacial velocity of the air-water separated flow using Styrofoam particles floating in water was conducted. The interfacial velocity values obtained with the two different measurement techniques showed good agreement with errors less than 5%. It was found from the experimental results obtained using the developed technique that with increasing air velocity, the interfacial velocity proportionally increases, likely because of the increased interfacial stress.

Dose Evaluation of Dental Artifacts Using MVCT in Head and Neck (두경부암 환자의 MVCT를 이용한 치아 인공물 보정에 따른 선량평가)

  • Shin, Chung Hun;Yun, In Ha;Jeon, Su Dong;Kim, Jeong Mi;Kim, Ho Jin;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.25-31
    • /
    • 2019
  • Purpose: Metals induce metal artifact during CT-image for therapy planning, and it occurs images distortion, which affects the volumetric measurement and radiation calculation. In the case of using megavoltage computed tomography(MVCT), the volume of metals can be measured as similar to true volume due to minimal metal artifact outcome. In this study, radiation assessment was conducted by comparing teeth volume from images of kVCT and MVCT of head and neck cancer patients, then assigning to kVCT image to calculate radiation after obtaining the similar volume of true teeth volume from MVCT. Also, formal IR image was able to verify the accuracy of radiation calculation. Material and method: 5 head and neck cancer patients who had intensity-modulated radiation therapy from Radixact® Series were of the subject in this study. Calculations of radiation when constraining true teeth volume out of kVCT image(A-CT) and when designated specific HU after teeth assigned using MVCT image were compared with formal IR image. Treatment planning was devised at the same constraints and mean dose was measured at the radiation assess points. The points were anterior of the teeth, between PTV and the teeth, the interior of PTV near the teeth, and the teeth where 5cm distance from PTV. Result: A difference of metals volume from kVCT and MVCT image was mean 3.49±2.61cc, maximum 7.43cc. PTV was limited to where the internal teeth were fully contained. The results of PTV dose evaluation showed that the average CI value of the kVCT treatment planning without the artifact correction was 0.86, and the average CI value of the kVCT with the artifact correction using MVCT image was 0.9. Conclusion: When the Treatment Planning was made without correction of metal artifacts, the dose of PTV was underestimated, indicating that dose uncertainty occurred. When the computerized treatment plan was made without correction of metal artifacts, the dose of PTV was underestimated, indicating that dose uncertainty occurred.