• Title/Summary/Keyword: IR absorption

검색결과 556건 처리시간 0.025초

TDLAS 시스템을 이용한 유해 배기가스의 농도 계측 (The Concentration Measurements of Toxic Exhaust Gas by Tunable Diode Laser Absorption Spectroscopy System)

  • 차학주;김민수;신명철;김세원;전광민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.222-227
    • /
    • 2003
  • Recent advances in room-temperature, visible and near-IR diode laser sources for telecommunication, optical data storage applications are enabling combustion diagnostics system based on diode laser absorption spectroscopy. In contrast to some traditional sampling-based gas-sensing instruments, tunable diode laser absorption spectroscopy system is advantageous because of their non-invasive nature, high sensitivity, fast response time and real-time measurement capability. So, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor system arc now appearing for a variety of applications. The objective of this research is to take advantage of distributed feed-back diode laser and measure the $CO_{2}$ concentration (by using direct absorption and wavelength modulation spectroscopy methods). In addition to survey spectra of $CO_{2}$ bands and spectroscopic parameters between 1565 and 1579 run were computed at temperatures between 296 and 1200 K (by using HITRAN 2000 database). It experimentally found out that the features of direct absorption and wavelength modulation spectroscopy methods.

  • PDF

Research on Preparation of Sheath-Core Bicomponent Composite Ion Exchange Fibers and Absorption Properties to Metal Ion

  • Ding, Zhi-Jia;Qi, Lu;Ye, Jian-Zhong
    • Macromolecular Research
    • /
    • 제16권1호
    • /
    • pp.21-30
    • /
    • 2008
  • Based on the sheath-core bicomponent composite fibers with modified polystyrene (PS) and the modified polypropylene (PP), composite fibers obtained were further cross-linked and sulphonated with chlorosulphonic acid to produce strong acidic cation ion exchange fibers. The structures of the fibers obtained were characterized using Fourier transform infrared (FT-IR) spectroscopy, differential scanning calorimetry (DSC) etc. The optimal technology of the fibers obtained is discussed. The static absorption capacity of the sheath-core bicomponent composite cation exchange fibers for $Zn^{2+}$, $Cu^{2+}$ was determined. The absorption kinetics and major factors affecting the absorption capacities of $Zn^{2+}$, $Cu^{2+}$ were studied, and its chemical stability and regenerating properties were probed. The results suggest that cation exchange fibers with better mechanical properties and higher exchange capability were obtained. Moreover, this type of ion exchange fiber has good absorption properties and working stability to various metal ions. Hence, they have higher practicability.

다이오드 레이저를 이용한 광흡수 농도 계측 기법 (I) (Species Concentration Measurement Using Diode Laser Absorption Spectroscopy (I))

  • 안재현;김용모;김세원
    • 한국연소학회지
    • /
    • 제9권3호
    • /
    • pp.27-35
    • /
    • 2004
  • Diode laser absorption sensors are advantageous because they may provide fast, sensitive, absolute, and selective measurements of species concentration. These systems are very attractive for practical applications owing to its compactness, resonable cost, robustness, and ease of use. In addition, diode lasers are fiber-optic compatible and thus enable simultaneous measurements of multiple species along a line-of-sight. Recent advances of room-temperature, near-IR and visible diode laser sources for telecommunication, optical data storage applications make it possible to be applied for combustion diagnostics based on diode laser absorption spectroscopy. Therefore, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor systems are now appearing for variety of applications. The objectives of this research are to develope a new gas sensing system and to verify feasibility of this system. Wavelength and power characteristics as a function of injection current and temperature are experimentally found out. Direct absorption spectroscopy has been demonstrated in these experiments and has a bright prospect to this diode laser system.

  • PDF

Hydrolytic Stability of Sulfonic Acid-Containing Polyimides for Fuel Cell Membranes

  • Kim Hyoung-Juhn;Litt Morton H.;Shin Eun-Mi;Nam Sang Yong
    • Macromolecular Research
    • /
    • 제12권6호
    • /
    • pp.545-552
    • /
    • 2004
  • The long-term stability of sulfonic acid-containing polyimides has been investigated. The hydrolytic degradation of homopolyimide and the block copolyimide comprising $27\;mol\%$ of 2,2'-bis(trifluoromethyl)benzidine and $9\;mol\%$ of m-phenylenediamine (BTFMB27mPl0[7/(3+1)]), was quantified through viscosity measurements and FT-IR spectroscopic analyses. The viscosity decrease with respect to time and the degradation rate were similar. The degrees of degradation with respect to time under ambient conditions and at elevated temperature in water were monitored by FT-IR spectroscopy. A new absorption peak was observed at $1786\;cm^{-1},$ which we corresponds to the presence of anhydride end groups formed by hydrolytic scission of the imide rings.

탈지분유 전처리에 의한 면직물의 물성 (The Physical Properties of Cotton Fabric Pretreated with Skim Milk Powder)

  • 이수민;송화순
    • 한국염색가공학회지
    • /
    • 제17권1호
    • /
    • pp.52-59
    • /
    • 2005
  • The purpose of this study is to establish the scientific data of cotton fabric pretreated with skim milk powder and to improve the dyeability. The surface monophology, add on, whiteness, stiffness, air permeability, moisture regain and absorption of cotton fabrics were evaluated by varying concentration of SMP to get the optimal conditions in pretreatment. FT-IR of cotton fabrics pretreated with SMP were measured. Amino acid compositions, viscosity of SMP were evaluated. The K/S values by varying concentration of cinnamon cassia and subtract of dyed SMP-C were measured. I attempted to evalute the color fastness of untreated and AI. The results are as follow; The optimal concentration of SMP was 9%(w/v) to be pretreated with cotton fabrics. From FT-IR spectrum, formation of -NH$_2$ and -COOH was verified by SMP-C. Denaturalization of protein and condensation of carbohydrate, fat, etc. were found in a measurement of amino acid and viscocity. The K/S value of cotton fabrics pretreated with SMP was higher than that of untreated. Most of the color fastnesses were great.

Time-Resolved Infrared Spectroscopy of Molecular Reorientation During FLC Electro-Optic Switching

  • Jang, Won-Gun;Clark, Noel A.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.1112-1117
    • /
    • 2003
  • Polarized Fourier transform infrared (IR) absorption is used to probe molecular conformation in a ferroelectric liquid crystal (FLC) during the reorientation induced by the external field. Spectra of planar aligned cells of FLC W314 are measured as functions of IR polarizer orientation and electric field applied to the FLC. The time evolution of the dichroism of the absorbance due to biphenyl core and alkyl tail molecular vibration modes, is observed. Static IR dichroism experiments show a W314 dichroism structure in which the principal axis of dielectric tensor from molecular core vibration are tilted further from the smectic layer normal than those of the tail. This structure indicates the effective binding site in which the molecules are confined in the Sm-C phase has, on average, "zig-zag" shape and this zig-zag binding site structure is rigidly maintained while the molecular axis rotates about the layer normal during field-induced switching.

  • PDF

Calculated and Experimental UV and IR Spectra of Oligo-para-phenylenes

  • Park, Kwangyong;Lee, Tae-Won;Yoon, Min-Ju;Choe, Jong-In
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권2호
    • /
    • pp.531-538
    • /
    • 2014
  • The quantum mechanical properties of a series of oligo-para-phenylenes (2-11) were characterized using DFT B3LYP/6-311G(d,p) calculations. The global minimum among the various torsional conformers of an oligo-p-phenylene is calculated to be a twist conformation. A less stable planar conformation, in which all the dihedral angles in oligo-p-phenylene are restricted to be planar, has also been calculated. The total electronic energies, normal vibrational modes, Gibbs free energies, and HOMOs and LUMOs of the two different conformations (twisted and planar) of the oligo-p-phenylenes were analyzed. The energy differences between the HOMOs and LUMOs of the substrates are in accord with the maximum absorption peaks of the experimental UV spectra of 2-6. The calculated normal vibrational modes of 2-6 were comparable with their experimental IR spectra.

수직분사제트에서의 헥산 증기농도측정 (Hexane Vapor Concentration Measurement of a Liquid Jet in Crossflow)

  • 오정석;이원남;이종근;도미니크 산타비카
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.383-389
    • /
    • 2010
  • 적외선 흡수법을 사용하여 액체 헵탄 수직분사제트의 증기농도를 정성적으로 측정하였다. 본 연구의 목적은 모형 램젯 연소기에서 레이저를 이용한 적외선 흡수법으로 액체연료의 분열부터 기화까지의 과정을 이해하는 것이다. 실험결과로부터 헥산 증기 몰분율은 온도가 증가함에 따라 증가하였으나 연료공기 운동량비 변화에 대해서는 큰 차이가 나지 않았다.

  • PDF

$PbTiO_3$ 박막의 적외선 스펙트럼특성과 초전감지소자의 모델링에 관한 연구 (A Study on IR Spectrum Characteristics of $PbTiO_3$ Thin Film and Pyroelectric Detector Modeling.)

  • 김성민;이문기;김봉열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(I)
    • /
    • pp.439-443
    • /
    • 1987
  • $PbTiO_3$ thin film is prepared by rf sputtering method to implement the pyroelectric infrared detector at room temperature. Annealing of $PbTiO_3$ thin film is done from $400^{\circ}C$ to $550^{\circ}C$ each for 2 hours in furnace. The spectral response to recrystallization process of $PbTiO_3$ thin film is measured by IR photospectro meter. Pyroelectric detector Modeling is studied for implementing device using electrical equivalent circuit model. It is found that $PbTiO_3$ thin film has two IR absorption band within $1000-400\;cm^{-1}$ (10um-25um) and it's spectral response is improved as annealing temperature increase. As a result of pyroelectric detector modeling, we find the possibility of implementing optimum device structure.

  • PDF

수직분사제트에서의 헥산 증기농도측정 (Hexane Vapor Concentration Measurement of a Liquid Jet in Crossflow)

  • 오정석;이원남;이종근
    • 한국추진공학회지
    • /
    • 제14권4호
    • /
    • pp.25-31
    • /
    • 2010
  • 적외선 흡수법을 사용하여 액체 헥산 수직분사제트의 증기농도를 정성적으로 측정하였다. 본 연구의 목적은 모형 램제트 연소기에서 레이저를 이용한 적외선 흡수법으로 액체연료의 분열부터 기화까지의 과정을 이해하는 것이다. 실험결과로부터 헥산 증기 몰분율은 온도가 증가함에 따라 증가하였으나 연료 공기 운동량비 변화에 대해서는 큰 차이가 나지 않았다.