• 제목/요약/키워드: IR Light

검색결과 557건 처리시간 0.024초

Quantifying Variability of YSOs in the Mid-IR Over Six Years with NEOWISE

  • Park, Wooseok;Lee, Jeong-Eun;Contreras Pena, Carlos;Johnstone, Doug;Herczeg, Gregory;Lee, Sieun;Lee, Seonjae;Bhardwaj, Anupam;Schieven, Gerald
    • 천문학회보
    • /
    • 제46권1호
    • /
    • pp.57.2-57.2
    • /
    • 2021
  • Variability in Young Stellar Objects (YSOs) can be caused by time-dependent accretion rates, geometric changes in the circumstellar disks, the stochastic hydromagnetic interactions between stellar surfaces and inner disk edges, reconnections within the stellar magnetosphere, and hot/cold spots on stellar surfaces. We uncover ~1400 variables from a sample of ~5300 YSOs in nearby low-mass star-forming regions using mid-IR light curves obtained from the 5.5-years NEOWISE All Sky Survey. The mid-IR variability traces a wide range of dynamical, physical, and geometrical phenomenon. We classify six types of YSO variability based on their light curves: secular variability (Linear, Curved, Periodic) and stochastic variability (Burst, Drop, Irregular). YSOs in earlier evolutionary stages have higher fractions of variables at all types and higher amplitudes for the variability. Along with brightness variability, we also find a diverse range of secular color variations, which can be attributed to a competitive interplay between the variable accretion luminosity of the central source and the variable extinction by material associated with the accretion process. We compare the variability of known FUors/EXors and VeLLOs/LLSs, which represent two extreme ends (burst versus quiescent) of the episodic accretion process; FUors/EXors have a higher fraction of variables (65%) than VeLLOs/LLSs (41%). Short-term (few day) and long-term (decades) variability, as well as possible AGB contamination in the YSO catalogues, are also discussed.molecules become more complex by surface chemistry induced directly by high energy photons or by the thermal energy diffused over heated grain surface. Therefore, the ice composition is an

  • PDF

영역기반 가중치 맵을 이용한 멀티스팩트럼 플래시 영상 획득 (Multi-spectral Flash Imaging using Region-based Weight Map)

  • 최봉석;김대철;이철희;하영호
    • 전자공학회논문지
    • /
    • 제50권9호
    • /
    • pp.127-135
    • /
    • 2013
  • 저조도 환경에서 카메라로 영상을 획득하기 위해 일반적으로 가시광 플래시를 사용하거나 장노출 기법을 사용하게 된다. 그러나 가시광 플래시를 사용할 때 플래시 광에 의한 색 왜곡이나 적목 현상, 눈부심에 의한 거부감을 발생시킨다. 또한 장노출을 사용하게 되면 물체의 움직임에 의한 흔들림 현상이 발생하게 된다. 따라서 최근에는 이러한 단점을 극복하고, 저조도 환경에서 고화질의 영상을 획득하기 위하여 멀티 스팩트럴 플래시(Multi-spectral flash image)를 이용하여 영상을 획득하는 방법이 소개되었다. 이 방법은 가시광과 UV/IR스펙트럼의 다섯 채널을 이용하여 가시광영상의 색 정보와 UV/IR 스팩트럼 영상의 세부정보를 최적화하여 영상을 획득하는 방법이다. 하지만, 픽셀 기반의 최적화 과정에 있어 색 왜곡과 다른 잡음을 발생시키게 된다. 따라서 본 논문에서는 이러한 색 왜곡과 잡음을 개선하기 위해 영역 기반의 가중치 맵을 최적화 방법에 적용하여 색 왜곡을 개선하는 알고리즘을 제안한다. 먼저, 영상에 대하여 Canny 에지 검출 방법을 사용하여 영상의 윤곽을 검출하였다. 이를 가중치 맵으로 최적화방법에 적용함으로, 세부 영역에 대하여 UV/IR 플래시 영상의 정보에 가중치를 부여하고, 평탄한 영역에 대하여 가시광 영상의 색 정보를 가중치를 부여하여 색 왜곡을 개선하였다. 제안한 방법을 평가하기 위하여 실험을 통하여 제안한 방법과 이전방법을 비교하였고, 객관적 평가와 주관적 평가 모두 제안한 방법이 우수한 성능을 나타내었다.

광학적 분석방법을 이용한 보폭측정 (Measurement of Stride Length Using Optical Method)

  • 정구인;전재훈;이강휘;송민선
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.1116-1122
    • /
    • 2008
  • Since conventional methods for measuring stride length(distance) are many weaknesses, optical methods have been developed to measure stride length(distance) of human pedestrians. IR(Infrared) elements and Power LED(Light Emitting Diode) with two types of lens were used to correlate detected light intensity with stride length(distance). The suggested methods in this study are simple, convenient, and cost effective. The results can be used to analyze walking patterns of normal and disabled men, and to monitor the recovering processes of the disabled patients.

적외선 불꽃감지기 개발연구 (The Research & Development of Infra-Red Flame Detector)

  • 이복영;권오승;정창기;박상태;조성수
    • 한국화재소방학회논문지
    • /
    • 제14권2호
    • /
    • pp.1-6
    • /
    • 2000
  • 가연물 연소시 불꽃의 복사에너지 Spectrum분석을 통하여 태양광, 인공광과 Flame의 spectrum특성해석으로 불꽃감지기술을 정립하였다. IR파장대의 복사에너지를 감지하기 위해 초전형 감지소자개발로 PZT소자를 개발하였으며, Band Pass Filter와 회로안정화기술을 적용한 적외선 불꽃화재감지기를 개발하였다. 시작품의 성능은 신뢰성 있는 적외선 불꽃감지기로 검증이 되었으며, 연구결과는 휘발유, 석유화학제품의 연소시 발생되는 불꽃을 조기에 감지하는 복사에너지 감지기가 개발되었다.

  • PDF

치과용 가시광선 중합형 복합수지의 새로운 광개시제에 관한 연구 (A Study on new Photoinitiator of Visible Light Dental Composite Resin)

  • 최용석;선금주
    • 대한치과기공학회지
    • /
    • 제23권2호
    • /
    • pp.49-59
    • /
    • 2002
  • The photopolymerization efficiency and surface hardness of composite resin containing 1,2-phenylpropanedione (PD) and diacetyl (DA) as photoinitiators were studied by IR and Vickers hardness and the results were compared with that of camphorquinone (CQ). Relative photopolymerization efficiency of the photoinitiators increased in the order of DA < CQ < PD. Vickers hardness of composite resin containing the photoinitiators increased in the order of CQ < PD < DA. Thus, PD is a new visible light photoinitiator for dental composite resin with higher photopolymerization efficiency and surface hardness than that of CQ. Mechanical properties such as Vickers hardness, diametral tensile strength, and flexural strength of the experimental resin composite prepared by addition of the photosensitizer into a resin of bis-GMA improved with increasing the photosensitizer content and irradiation time. The resin composite of bis-GMA containing DA or PD shows better mechanical properties than that of CQ.

  • PDF

생체 신호의 무구속 측정을 위한 근 적외선 특성 연구 (A Study on the Characteristics of near IR lights for non-restrained Biotelemetry)

  • 허수진;정찬수
    • 대한의용생체공학회:의공학회지
    • /
    • 제13권2호
    • /
    • pp.141-146
    • /
    • 1992
  • The propagation, reflection and scattering characteristics of the near Infra-red lights were experimented in order to check the feasibility of non-restrained biotelemetry using indirect transmitted light. The results of the experiments show that 3 kinds of walls examined are not specular reflectors but almost perfect diffuse surfaces with slight directivity and that light in a local point is spread out and fills the room uniformly by repeating the reflection and scattering at walls, ceiling, floor. These results also explain the fact that the diffusely reflected light can be utilized as the carrier of biotelemetry even after several scattering and reflections.

  • PDF

A Study on the Optimized Test Condition of Lock-in IR Thermography by Image Processing

  • Cho, Yong-Jin
    • 비파괴검사학회지
    • /
    • 제32권3호
    • /
    • pp.276-283
    • /
    • 2012
  • In this study, it was studies the utilization of LIT(lock-in infrared thermography) which can detect defects in welded parts of ship and offshore structures. Quantitative analysis was used through methods of filtering and texture measurement of image processing techniques to find the optimized experimental condition. We verified reliability in our methods by applying image processing techniques in order to normalize evaluations of comparative images that show phase difference. In addition, low to mid exposure showed good results whereas high exposure did not provide significant results in regards to intensity of light exposure on surface. Lock-in frequency was satisfactory around 0.1 Hz regardless of intensity of light source we had. In addition, having the integration time of thermography camera inversely proportional to intensity of exposed light source during the experiment allowed good outcome of results.

Synthesis and Characterization of Poly(fluorenylenevinylene-terphenylenevinylene) Containing Phenyl Pendant Group

  • Kim Yun-Hi;Jung Sung-Ouk;Lee Kwang-Hoi;Kwon Soon-Ki
    • Macromolecular Research
    • /
    • 제14권1호
    • /
    • pp.81-86
    • /
    • 2006
  • Poly(fluorenylenevinylene-terphenylenevinylene) containing phenyl pendant group was synthesized by Suzuki coupling reaction and characterized by ${1}^H$-NMR, ${13}^C$-NMR, and IR-spectrum. The weight average molecular weight ($M_{w}$) of the obtained polymer was 31,000 with a polydispersity index of 1.9. The polymer showed good solubility in common organic solvents, and the solution and film emitted blue emission ($\lambda_{max}$=460 nm) on irradiation with UV light. The ITO/PEDOT/polymer/Al device fabricated using the polymer as an emitting layer emitted blue light with a maximum peak around 460 nm. The maximum efficiency of the device was 0.011$\%$.

청소 로봇 성능 향상을 위한 먼지 검출 시스템 (A Dust Detection Sensor System for Improvement of a Robot Vacuum Cleaner)

  • 김동회;민병철;김동한
    • 제어로봇시스템학회논문지
    • /
    • 제19권10호
    • /
    • pp.896-900
    • /
    • 2013
  • In this paper, we develop a dust detection sensor system capable of identifying types of dust for an improvement of a robot vacuum cleaner. The dust detection sensor system is composed of a set of infra-red sensors: a single transmitter and multiple receivers. Given the fixed amount of light transmitted from the transmitter, the amount of light coming in multiple receiver sensors varies, depending on the type and density of dust that is passing between the transmitter and the receivers. Therefore, the type of dust can be identified by means of observing the change of the amount of light from the receiver sensors. For experiments, we use two types of dust, rice and sesame, and validate the effectiveness of the proposed method.

Design and Synthesis of New Fluorene-Based Blue Light Emitting Polymer Containing Electron Donating Alkoxy Groups and Electron Withdrawing Oxadiazole

  • Kim, Yun-Hi;Park, Sung-Jin;Park, Jong-Won;Kim, Jin-Hak;Kwon, Soon-Ki
    • Macromolecular Research
    • /
    • 제15권3호
    • /
    • pp.216-220
    • /
    • 2007
  • A new polyfluorene-based copolymer having 2-ethylhexyloxy-5-methoxy-l,4-phenylene as an electron donating group and 2,5-diphenyl-oxadiazole as an electron withdrawing group was synthesized by the Suzuki coupling reaction. The obtained copolymer was characterized by $^1H-NMR,\;^{13}C-NMR$, and IR-spectroscopy. The weight average molecular weight ($M_w$) of the obtained polymer was 18,600 with a polydispersity index of 1.5. The maximum photoluminescence of the solution and film of the polymer was observed at 453 nm and 456 nm, respectively. A double-layer device with the configuration, ITO/PEDOT/copolymer/Al, emitted blue light at 460 nm.