$MnO_2$ 첨가량에 따른 $BaTiO_3$계의 PTC효과와 원적외선 방사특성에 관한 연구 (A study on the Radiation Properties of Far-infrared and PTC Effect in the $BaTiO_3$ system by $MnO_2$ Amounts of Additives)

  • 송민종;박춘배;강도열
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1993년도 춘계학술대회 논문집
    • /
    • pp.3-5
    • /
    • 1993
  • It is very important that a spectrum of reflectance is in accord wi th a spectrum of absorbance for a effective heating. Therefore. the objective of this study was to achieve a technical composite for material plan which PTC thermistor increase a radiation property of far-infrared and keep a characteristic of R-T The Ceramic speciman studies had the composition $BaTiO_3$ with additive of 1.67 $Al_2O_3$, 3.75 $SiO_2$, 1.25 $TiO_2$, 0.15 $Sb_2O_3$ and 0.00-0.182 $MnO_2$. $MnO_2$ amounts of additives was both increase on the anomalous resistivity-temperature characteristics and high efficiency on the radiation properties bodies of far-infrared. This result shows that specimens produced high emissivity(average 0.8) of far-infrared at 4.5-15$[{\mu}m]$ by measuring a characteristic of IR and R-T.

  • PDF

Transparent and Flexible All-Organic Multi-Functional Sensing Devices Based on Field-effect Transistor Structure

  • Trung, Tran Quang;Tien, Nguyen Thanh;Seol, Young-Gug;Lee, Nae-Eung
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.491-491
    • /
    • 2011
  • Transparent and flexible electronic devices that are light-weight, unbreakable, low power consumption, optically transparent, and mechanical flexible possibly have great potential in new applications of digital gadgets. Potential applications include transparent displays, heads-up display, sensor, and artificial skin. Recent reports on transparent and flexible field-effect transistors (tf-FETs) have focused on improving mechanical properties, optical transmittance, and performances. Most of tf-FET devices were fabricated with transparent oxide semiconductors which mechanical flexibility is limited. And, there have been no reports of transparent and flexible all-organic tf-FETs fabricated with organic semiconductor channel, gate dielectric, gate electrode, source/drain electrode, and encapsulation for sensor applications. We present the first demonstration of transparent, flexible all-organic sensor based on multifunctional organic FETs with organic semiconductor channel, gate dielectric, and electrodes having a capability of sensing infrared (IR) radiation and mechanical strain. The key component of our device design is to integrate the poly(vinylidene fluoride-triflouroethylene) (P(VDF-TrFE) co-polymer directly into transparent and flexible OFETs as a multi-functional dielectric layer, which has both piezoelectric and pyroelectric properties. The P(VDF-TrFE) co-polumer gate dielectric has a high sensitivity to the wavelength regime over 800 nm. In particular, wavelength variations of P(VDF-TrFE) molecules coincide with wavelength range of IR radiation from human body (7000 nm ~14000 nm) so that the devices are highly sensitive with IR radiation of human body. Devices were examined by measuring IR light response at different powers. After that, we continued to measure IR response under various bending radius. AC (alternating current) gate biasing method was used to separate the response of direct pyroelectric gate dielectric and other electrical parameters such as mobility, capacitance, and contact resistance. Experiment results demonstrate that the tf-OTFT with high sensitivity to IR radiation can be applied for IR sensors.

  • PDF

Smoothness of the Zodiacal Light and Emission from the AKARI North Ecliptic Pole Monito rObservations

  • Pyo, Jeong-Hyun;Matsumoto, Toshio;Tange, Tsutomu;Jeong, Woong-Seob;Matsuhara, Hideo;Matsuura, Shuji;Wada, Takehiko;Seo, Hyun-Jong;Hong, Seung-Soo
    • 천문학회보
    • /
    • 제35권2호
    • /
    • pp.52.1-52.1
    • /
    • 2010
  • The Japanese infrared (IR) space mission AKARI monitored the brightness in the fields very close to the north ecliptic pole (NEP) with nine wavebands in Infrared Camera (IRC), which cover the wavelength range from 2 to $24{\mu}m$. We reduced the NEP monitor observations and examined the smoothness of the sky background brightness. Our analysis shows that the background brightness is smooth over a frame of about $10'\times10'$ within about 0.1% deviation in mid-IR. Because the zodiacal light (ZL) and emission (ZE) dominate the diffuse sky brightness in the near- and mid-IR wavelengths, the background brightness varies with season through a year. We tried sinusoidal fittings to the observed NEP background brightness. The fitting analysis shows that the sine function is successful in describing the seasonal variation of the ZL and ZE within 2% deviations from the observed brightness, especially for the 15, 18, and $24{\mu}m$ bands, within 0.3%. These results will provide limits and caveats for the studies of the cosmic infrared background radiation.

  • PDF

적외선 센서 냉각용 극저온 용기의 과도 냉각 특성에 관한 수치해석 (Numerical Analysis on the Transient Cooling Characteristics of an Infrared Detector Cryochamber)

  • 이정훈;김호영;강병하
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.68-72
    • /
    • 2002
  • This work investigates the transient cooling characteristics of an Infrared (IR) detector cryochamber, which has a critical effect on the cooling load. The current thermal modeling considers the conduction heat transfer through a cold well. the gaseous conduction due to outgassing. and the radiation heat transfer. The transient cooling Performance. i.e. the penetration depth and cooling load, is determined using a finite difference method. It is found that the penetration depth increases as the bore conductivity increases. Gaseous conduction and radiation hardly affect the penetration depth. The transient cooling load increases as the bore conductivity increases. The effects of gaseous conduction and radiation on transient heat transfer are weak at initial stages of cooling. However, their effects become significant as the cooling Process Proceeds.

자외선/적외선 불꽃감지기 소개 및 오동작 방지를 위한 연구 (Introduction of Ultraviolet/Infrared Flame Detector and Method for False Detection Prevention)

  • 임병현;고낙용;황종선;김영민;김종만
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 기술교육전문연구회
    • /
    • pp.8-11
    • /
    • 2003
  • We propose that when combustible burn with contain carbon, introduce fire detector with sensor of private-use detectable light energy as infrared and ultraviolet in energy of electromagnetic-wave type radiate from flame, method for correct discrimination to resemble fire produce false alarm of detector such as sun light, hot object radiation, are welding. This research using infrared sensor is pyroelectric infrared sensor based black body radiation theory. Ultraviolet sensor is uv Tron using gas multiplication effect to current discharge and photoelectric effect of metal. To have high sensibility and to gain proper output voltage, it has high responsive performance. This research introduced UV/IR compound type flame detector and proposed method of false alarm reduced to resemble fire. The result propres the prevention and extinction of fire technique degree, certificated operation of detector.

  • PDF

터보팬을 모사한 소형 엔진에서의 바이패스 비에 따른 적외선 신호 측정 (Infrared Signal Measurement with Bypass Ratio in a Small Engine Simulating a Turbofan)

  • 최재원;장현식;김혜민;최성만
    • 한국추진공학회지
    • /
    • 제24권5호
    • /
    • pp.34-42
    • /
    • 2020
  • 현대 항공전에서 적외선 신호는 상대방 탐지에 있어 중요한 역할을 하며, 생존성 및 스텔스성 향상을 위해 저감되어야 한다. 특히 항공기 엔진 후류에서 발생하는 적외선 신호는 높은 강도를 가지며 파장이 짧아 대부분의 열 추적 미사일이 이러한 신호를 따라 탐지하게 된다. 이에 따라 본 연구에서는 엔진 후류에서 발생하는 Gas radiation 신호 측정 및 특성 분석을 수행하였다. 실제 항공기 터보팬 엔진을 모사하기 위해 마이크로 터보제트 엔진을 구성하였으며, 바이패스 비 조절을 통한 적외선 신호 저감 특성을 파악하였다. 이를 통해 각 파장 별 적외선 신호 특성을 분석하고 신호 저감 기술들에 대한 검증을 수행한다.

양극산화된 알루미늄의 적외선 복사특성 연구 (A Study on the Infrared Radiation Properties of Anodized Aluminum)

  • 강병철;최정진;김기호
    • 한국표면공학회지
    • /
    • 제35권3호
    • /
    • pp.149-157
    • /
    • 2002
  • Spectral emissivity depends on the surface conditions of the materials. The mechanisms that affect the spectral emissivity in anodic oxide films on aluminum were investigated. The aluminum specimens were anodized in a sulfuric acid solution and the thickness of the resulting oxide film formed changed with the anodizing time. FT-IR spectrum analysis identified the anodic oxide film as boehmite ($Al_2$$O_3$.$H_2$O). Both the infrared emisivity and reflectivity of the anodized aluminum were affected by the structure of the anodic oxide film because Al-OH and Al-O-Al have a pronounced absorption band in the infrared region of the spectrum. The presence of an anodic oxide film on aluminum caused a rapid drop in the infrared reflectivity. An aluminum surface in the clean state had an emissivity of approximately 0.2. However, the infrared emissivity rapidly increased to 0.91 as the thickness of the anodic oxide film increased.

적외선 카메라 KAONICS의 열해석 (A STUDY OF THERMAL ANALYSIS OF KAONICS)

  • 강지나;이성호;진호;박수종;문봉곤;김상호;박장현
    • Journal of Astronomy and Space Sciences
    • /
    • 제21권4호
    • /
    • pp.467-480
    • /
    • 2004
  • KAONICS(KAO Near Infrared Camera System)와 같은 적외선 카메라는 열잡음제거가 매우 중요하다. 입사창을 통해 들어오는 외부의 열복사 이외에도 카메라의 외벽을 통해 유입되는 열복사가 배경복사로서 검출기에 입사하여 시스템의 성능을 저하 시키며 그 양은 무시할 수 없다. 따라서 배경복사와 검출기 자체의 열잡음을 줄이기 위해서 카메라 내부의 광학계 전체와 검출기를 냉각해야만 한다. 이에 본 연구에서는 J, H, Ks, L 파장 대를 관측하기 위한 내부 냉각온도를 정량적으로 결정하였으며 카메라 외부에서 유입되는 복사량을 추산하고 냉각에 필요한 냉각 열용량을 추정하여 냉각기를 선택하였다. 선택된 냉각기를 이용하여 냉각할 때 Cold-Box가 목표온도에 도달하는 시간과 최종 냉각 온도를 계산하여 시스템 제작에 반영하였다.

퓨리에 변환 적외선 분광기를 이용한 수직 분광 복사율 측정 장치의 제작과 측정 (Construction and Measurement of Normal Spectral Emissivity Device using Fourier Transform Infrared Spectrometer)

  • 전상호;유남준;조재흥;박철웅;박승남;이근우
    • 한국광학회지
    • /
    • 제19권6호
    • /
    • pp.400-407
    • /
    • 2008
  • 퓨리에 변환 적외선 분광기(FT-IR)를 이용한 물질의 적외선 분광 복사율 측정 장치를 구축하고 이 장치의 성능을 평가하였다. 본 장치는 기준 흑체, 시료 가열로, 광학계, FT-IR로 구성되어 있으며, 측정 온도 및 파장 영역은 $200^{\circ}C{\sim}500^{\circ}C$$3.5{\mu}m{\sim}20{\mu}m$ 이다. 기준 흑체의 유효 복사율은 0.9993 이상으로 거의 1에 가까운 값을 나타내고 있었으며, 흑체의 분광 복사율에 대한 합성 상대 불확도는 0.69% 이하이다. $300^{\circ}C$에서 불투명한 알루미나, 흑연, 양극 처리된 알루미늄 시료의 수직 분광 복사율과, 금속(IMS200)의 표면 거칠기에 따른 복사율을 측정하였다. 금속(IMS200)의 표면 거칠기에 따른 복사율 변화는 거칠기가 증가할수록 증가하였다.

적외선 감지 센서를 이용한 점 용접부의 검사 (Inspection of the spot welding using IR sensor)

  • 임대철;박인태;강형식;권대갑
    • 한국정밀공학회지
    • /
    • 제16권1호통권94호
    • /
    • pp.132-140
    • /
    • 1999
  • This paper suggests a monitoring method for the pulsed laser spot welding of the thin metal sheets using a point IR(InfraRed) sensor. A new criterion was introduced and the experimental results guaranteed the efficiency. The ideal radiation feature was derived from the mathematical model and was simulated. The radiation feature is robust to withstand the change of measuring condition and can be used to detect the absorbed laser energy. In an experiment, the radiation feature was examined for the differect laser energy. The pulse width and the laser power was variated and the radiation feature was examined. In the other experiment, the relationship between the weld strength and radiation feature was examined. Artificial Neural Network(ANN) was employed to find out the relationship. The correlation coefficient between the real strength and the estimated strength is high as 0.94 and the mean square error is low as 0.64 kgf learned parts. Another group of the welds was used to appraise the learning efficiency. The correlation coefficient between the measured and the estimated weld strength is high as 0.91.

  • PDF