• Title/Summary/Keyword: IP Board

Search Result 122, Processing Time 0.029 seconds

Design and Implementation of the Diseases Diagnosis System Using The Cantilever Micro-Arrays (박막 캔틸레버 어레이 센서를 이용한 질병 진단기 설계 및 구현)

  • Jung, Seung-Pyo;Choi, Jun-Kyu;Lee, Jung-Hoon;Park, Ju-Sung
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.52-57
    • /
    • 2015
  • The disease diagnosis system has been developed using the thin nitride(Si3N4) cantilever arrays which can measure the difference of capacitances between sensor and reference. The system consists of 32-bits RISC(Reduced Instruction Set Computer), RAM/Flash, bus, communication IP's, ADC(Analog Digital Converter) board, and LCD display. The marker selection method, which give us the good accuracy from reasonal numbers of markers, is suggested. The developed system has the resolution under 1fF and can detect 10nM concentration of Thrombin.

Development of a remote monitoring system for gas detection at the subway station (지하철 역내 가스 검출 원격 모니터링 시스템 구현)

  • Park, Yong-Man;Kim, Hei-Sik;Kim, Gyu-Sik;Lee, Moon-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.439-441
    • /
    • 2007
  • The seoul metropolitan subway has installed 8 lines and about 500 stations to transport 5 million passengers everyday. The underground air pollution level in the subway stations is very severe status, which is very harmful to the commutators and its personals. Although subway roles as such a massive and huge transportation system, the subway doesn't adapt yet any real-time air monitoring system. They have only some hand-held type detector equipments for monitoring air pollution. Therefore subway passengers are exposed to the harmful air pollution environment. The most harmful environmental parameters among the air pollution are known as the dust and sound noise dB level in the subway station. Because the dust is consisted of very small particles, we can't see them easily in dark condition on the platform, but it is very harmful. The monitoring system for air pollution is developed using embedded system attached with 6 different environmental sensors. This system monitors air pollution of dust sound noise, gas, temperature, humidity, inflammable gas, toxic gas in the subway ?station. The sensor unit of the ARM-CPU board and sensor transmits real time environmental data to the main server using Zigbee wireless communication module and TCP/IP network. The main control server receives and displays the real-time environmental data, and it send alarms to the personals when high level value.

  • PDF

The Design and implementation of a 5.8GHz band LNA MMIC for Dedicated Short Range Communication (단거리전용통신을 위한 5.8GHz대역 LNA MMIC 설계 및 구현)

  • 문태정;황성범;김용규;송정근;홍창희
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.8
    • /
    • pp.549-554
    • /
    • 2003
  • In this paper, we have designed and implemented by a monolithic microwave integrated circuit(MMIC) of a 5.8GHz-band low noise amplifier (LNA) composed of receiver front-end(RFE) in a on-board equipment system for dedicated short range communication. The designed LNA is provided with two active devices, matching circuits, and two drain bias circuits. Operating at a single supply of 3V and a consumption current of 18mA, The gain at center frequency 5.8GHz is 13.4dB, NF is 1.94dB, Input IP3 is -3dBm, S$_{11}$ is -18dB, and S$_{22}$ is -13.3dB. The circuit size is 1.2 $\times$ 0.7 $\textrm{mm}^2$.>.

Design of the SD Protocol Analyzer (SD 프로토콜 분석기 설계)

  • Moon, Ji-Hoon;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.11
    • /
    • pp.1697-1706
    • /
    • 2013
  • Protocol analyzer is being used to analyze proper processing of CMD & data when developing SD slave IP. In this thesis, a protocol analyzer was developed for analyzing SD protocol in Windows environment using Visual C++. SD protocol analyzer consists of embedded Linux software for storing SD memory data and MFC program for analyzing this. As for protocol analysis, it has been designed to collect data transmitted from SD memory card to host by Linux software for its analysis by MFC. It was found through the experiment that the CMD type could be confirmed that occurs when reading and writing data to SD memory card using the developed board, and debugging the problems that occur was possible.

Wireless Ordering System For Embedded (무선 임베디드 주문 시스템)

  • Kim, min-seong;Cho, sang-hee;Jeong, seong-cheol;Lee, sang-gyu;Hong, kyung-ho
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.569-572
    • /
    • 2008
  • I proposed wireless ordering system using Qt embedded. This system will make the good use of real life applications and make fit for practical use. I embodied data input, transfer, gathering and back-transfer on wireless network using TCP/IP protocol on QSocket provided by Qt. Server environment is Linux 9.0 and gcc-2.95.3 on PC, and three target-boards consist PXA255 processor with wireless-LAN card which communicate through wireless access pointer. Software tools on target-board are gcc, tmake, qt-X11, qt-embedded and etc. I designed touch-screen interface for user convenience.

  • PDF

Robust Obstacle Detection and Avoidance Algorithm for Infrastructure-Based Vehicle Communication Under Signal Interference (중계기를 통한 다중 차량 간 통신 상황에서 신호 간섭에 강한 장애물 감지 및 회피 알고리즘)

  • Choi, Byung Chan;Kwon, Hyuk Chan;Son, Jin Hee;Nam, Haewoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.5
    • /
    • pp.574-580
    • /
    • 2016
  • In this paper, we will introduce the system that can control multiple vehicles on the road through Single Board Computers and V2I (Vehicle-To-Infrastructure). Also, we will propose the group evasive maneuver decision algorithm, which plays a critical role in deciding whether the vehicles in the system have to conduct evasive maneuvers to avoid obstacles on the road. In order to test this system, we have utilized Wi-Fi and TCP/IP for establishing the communication between multiple vehicles and the relay server, and observed their driving states on the road with obstacles. During the experiments, we have discovered that our original decision algorithm possesses high failure rate when there is frequency interference in ISM (Industrial Scientific Medical) band. In order to reduce this failure rate, we have implemented the data transition detector. This paper will focus on how the use of data transition detector can affect the reliability of the system under the frequency interference of ISM band. If this technology is improved and applied in the field, we will effectively deal with such dangerous situations as multiple collision accidents through vehicle-to-vehicle communication or vehicle-to-infrastructure communication. Furthermore, this can be applied to the autonomous driving technologies. This can be used as the reference data for the development of the similar system.

Implementation of Image Transmission Server System using Embedded Linux (임베디드 리눅스 기반의 영상전송서버 시스템 구현)

  • Jung, Yeon-Sung;Nam, Boo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.388-390
    • /
    • 2004
  • In this paper, we performed the implementation of image transmission server system using embedded system that is for the specified object and easy to install at any places and move to wherever. Since the embedded system has lower capability than PC, we have to reduce the quantity of calculation and transmission. The image compression like JPEG, needs that the server calculates for making compressed image, makes the server carry the load. So we compresses the image at the server and transmit the codes to the clients connected, then the received codes from server are decoded and displayed at the clients. In this process to make the image compression and transmission effectively, we decrease the procedure as simple as possible to transmit the data in almost real-time. We used the Redhat linux 9.0 OS at the host PC and the target board based on embedded linux. The image sequences are obtained from the camera attached to the FPGA board with ALTERA chip. For effectiveness and avoiding some constraints, we made the device driver. Generally the image transmission server is PC, but using the embedded system as a server makes the server portable and cheaper than the system based on PC.

  • PDF

Implementation of a Fieldbus System Based on Profibus-DP Protocol (Profibus-DP 프로토콜을 이용한 필드버스 시스템 구현)

  • Bae, Gyu-Sung;Kim, Jong-Bae;Park, Byoung-Wook;Lim, Kye-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.10
    • /
    • pp.903-910
    • /
    • 2000
  • In this paper, we describe a slave chip based on the Profibus-DP protocol and a system board to verify the developed slave chip. The Profibus-DP protocol is designed using VHDL and implemented on FPGA. The system board adopting the developed FPGA is designed FPGA is designed in which the firmware is implemented on Intel 8051 by using C language. Among the Profibus-DP protocols, low level layers from the physical layer to the data link layer is implemented in the form of hardware that we are able to greatly reduce the CPU load in processing protocols, and then higher layers could be processed by software. These technologies result in an IP to make terminal devices in the distributed control systems. Therefore, many digital logics as well as communication logics can be implemented onto SOC(System On a Chip) and it could be applied to various fieldbus-related areas.

  • PDF

A Study about Preventing Improper Working of Equipment on ATS System by Signaling Equipment (신호장치에 의한 ATS 신호장치 오동작 방지에 대한 연구)

  • Ko, Young-Hwan;Choi, Kyu-Hyoung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.579-587
    • /
    • 2008
  • Promotion of the line no.2 in Seoul Metro was changing from the existing signaling facilities for ATS(Automatic Train Stop) vehicles to the up-to-date signaling facilities for ATO(Automatic Train Operation). But, in consequence of conducting a trial run after being equipped with the ATO signaling facilities, the matter related to mix-operation with the existing ATS signaling facilities appeared. The operation of the existing ATS signaling system in combination with the ATO signaling system has made improper working related to frequency recognition of the ATS On-board Computerized Equipment. This obstructs operation of a working ATS vehicle. That is, as barring operation of an ATS vehicle that should proceed, it may make the proceeding ATS vehicle stop suddenly and after all, it will cause safety concerns. In this paper, we designed a wayside track occupancy detector that previously prevents improper working related to frequency recognition of the ATS On-board Computerized Equipment by gripping classification and working processes of operating trains throughout transmission of local signaling information from the existing facilities, which does not need to change or replace the existing signaling facilities. Furthermore, we described general characteristics of the wayside track occupancy detector and modeled the IFC(InterFace Contrivance) device and the logical circuit recognizing signal information. Then, we made an application program of PLC(programmable Logic Computer) based on the stated model. We, in relation to data transfer method, used the frame in TCP/IP transfer mode as the standard, and we demonstrated that ATO transmission frequency is intercepted.

  • PDF

Development of Digital Endoscopic Data Management System (디지탈 내시경 데이터 management system의 개발)

  • Song, C.G.;Lee, S.M.;Lee, Y.M.;Kim, W.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.304-306
    • /
    • 1996
  • Endoscopy has become a crucial diagnostic and theraputic procedure in clinical areas. Over the past three years, we have developed a computerized system to record and store clinical data pertaining to endoscopic surgery of laparascopic cholesystectomy, peviscopic endometriosis, and surgical arthroscopy. In this study, we are developed computer system, which is composed of frame grabber, sound board, VCR control board, LAN card and EDMS(endoscopic data management software). Also, computer system has controled over peripheral instruments as a color video printer, video cassette recorder, and endoscopic input/output signals(image and doctor's speech). Also, we are developed one body system of camels control unit including an endoscopic miniature camera and light source. Our system offer unsurpassed image quality in terms of resolution and color fidelity. Digital endoscopic data management system is based on open architecture and a set of widely available industry standards, namely: windows 3.1 as a operating system, TCP/IP as a network protocol and a time sequence based database that handles both an image and drctor's speech synchronized with endoscopic image.

  • PDF