• Title/Summary/Keyword: IMPLANT

Search Result 6,058, Processing Time 0.03 seconds

Implant-supported fixed prosthesis restoration of fully edentulous patient using computer-guided implant surgery and immediate loading: A case report (Computer guided implant surgery와 immediate loading을 활용한 무치악 환자의 전악 임플란트 고정성 보철물 수복 증례)

  • Hyeon-Me Sung;Kyoung-Hee Sul;Sun-Woo Kang;Jung-Han Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.131-139
    • /
    • 2024
  • In a edentulous patient, various methods can be employed for prosthetic treatment using implants, such as implant-supported fixed prostheses, overdentures, hybrid prostheses, and implant assisted removable partial denture. In this case, in a patient with moderate to severe chronic periodontitis requiring full arch extractions, implants were strategically placed using computer-guided surgery. In the maxilla, due to inadequate bone quality and quantity leading to insufficient initial stability, delayed loading was implemented, and interim prosthesis was used during the osseointegration period. In the mandible, stable initial stability was achieved, allowing for immediate loading to reduce patient discomfort. Primary stability is considered the most crucial factor for obtaining immediate loading, so a thorough clinical and radiological evaluation of the remaining alveolar bone quantity and quality must be conducted before surgery.

Mandibular Posterior Rehabilitation Case after Occlusal Plane Correction using Micro-Implant Anchorage (Micro-Implant를 이용한 교정치료로 교합평면 개선 후 하악 구치부 수복증례)

  • Park, Ju-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.2
    • /
    • pp.143-150
    • /
    • 2004
  • Endosseous implants have been used to provide anchorage control in orthodontic treatment without the need for special patient cooperation. However these implants have limitation like space requirement, cost, equipments. Recently titanium micro-implant for orthodontic anchorage was introduced. Micro-implants are small enough to place in any area of the alveolar bone, easy to implant and remove, and inexpensive. In addition, orthodontic force application can begin almost immediately after implantation. The mandibular first, maxillary first, mandibula second, and maxillary second molars were the four most commonly missing teeth in adult sample. In case of posterior molar teeth missing, deflective contacts in any position, over time, has produced pathologic change of occlusal scheme because of extrusion of opposing teeth. This case had interocclusal space deficiency by mandibular right molars missing over time. The micro-implants had been used for intrusion of maxillary right molars for interocclusal space. The micro-implant would be absolute anchorage for orthodontic movement. Therefore, the micro-implant would be effective method for correction of occlusal plane.

DENTAL IMPLANT TREATMENT WITH ILIAC BONE GRAFT VIA TWO-STAGE APPROACH FOR AVULSED ALVEOLAR BONE DEFECTS; CASE REPORT (외상성 치조골 상실 후 장골 이식을 동반한 이회법 임플란트 치료; 증례보고)

  • Choi, Young-Jun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.4
    • /
    • pp.386-390
    • /
    • 2007
  • This is about the case of loss of multiple teeth and alveolar bone caused by trauma, which needed alveolar bone augmentation before implant treatment. Alveolar bone was reconstructed using iliac bone graft, and thereafter first implant surgery was followed by consolidation period of 3 months. Iliac bone resorption was observed at the time of implant placement. And that resorption was more in the horizontal dimension than in the vertical. We conclude that additional treatment planning(e.g. using alveolar distraction osteogenesis or tissue expander) should be considered besides bone graft for vertical alveolar bone augmentation. For both maxilla and mandible, prosthodontic treatment was carried out $4{\sim}5$ months after implant placement. To compensate alveolar bone deficiency, partial hybrid overdenture on maxilla and implant-supported fixed bridge on mandible were fabricated, and the total treatment was finished.

Design Evaluation of Expandable Implants by the Finite Element Method (유한요소법에 의한 근단부 팽창형 임프란트 모델의 설계평가)

  • Park, Sang-Seok;Chae, Soo-Won;Kwon, Jong-Jin
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.406-411
    • /
    • 2001
  • The expandable implant employs an inner expansion screw in order to expand several legs of implant. Compressive stresses are produced at the bone tissue surrounding the implant, and the contact area between the implant and the bone tissue is increased, which result in increased resistance to horizontal and vertical pressure loads. The stress distribution in implant is also an important factor. Three types of implant models including an existing one have been investigated by using the Finite Element Method, and an improved design model has been suggested.

  • PDF

External vs internal connection implant system (External vs internal implant : 각각의 장점과 고려사항)

  • Seong, Dong-Jae;Hong, Seoung-Jin;Ha, Seung-Ryong
    • The Journal of the Korean dental association
    • /
    • v.54 no.3
    • /
    • pp.184-190
    • /
    • 2016
  • The osseointegration of titanium implants has been examined over the past 50 years. Many implant systems have been introduced and have become popular to the implant dentistry. The designs of the connection between implant fixture and abutment are divided into external vs internal connection. From beginning, the $Br{\aa}nemark$ system was characterized by an external hexagon. Internal connection has been developed to reduce stress transferred to the bone. These differences may have impact on the clinical procedures and protocols, laboratory and components costs, and incidence of complications. Therefore, the clinician has to know the different biomechanical features and understand their implications to produce successful implant-supported prosthesis with an external or an internal connection system.

  • PDF

THE TRANSMANDIBULAR IMPLANT SYSTEM (The Transmandibular Implant System)

  • Moon, Hong-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.3
    • /
    • pp.435-444
    • /
    • 1997
  • Many of the problems which are faced to the edentulous patients are related to a minimal amount of available mandibular bone volume and height. Most of the patients with mild atrophy of the mandible are treated using endosseous implant prosthodontics. TMI(Trans-mandibular Implant) can be used in case of severe mandibular atrophy, poor bone quality, atrophy of the mandible with exposed of inferior alveolar nerve, osteoporosis and the fracture of the atrophic mandible. Also it can eliminate the need for bone grafting and vestibuloplasty. The TMI is a rigid box frame structure which controls and distribute the masticatory force over the severely resorbed mandible. The box frame structure consist of a superstructure, baseplate, 4 transosseous posts, and 5 cortical screws. This is a case report that also describes about the transmandibular implant reconstruction system.

  • PDF

Comparative study on the radiopacity of different resin-based implant cements (레진계 임플란트용 시멘트의 방사선 불투과성에 대한 비교연구)

  • Han, Kyeong-Hwan;Cheon, Ho-Young;Kim, Min-Su;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.97-104
    • /
    • 2014
  • This study was aimed to compare the radiopacity of four kinds of currently available resin based implant cements using digital radiography. Materials and Methods: Four resin-based implant cements((Estemp $Implant^{TM}$ (Spident, Incheon, Korea), $Premier^{(R)}$Implant (Premier, Pennsylvania, USA), $Cem-Implant^{TM}$ (B.J.M lab, Or-yehuda, Israel), $InterCem^{TM}$ (SCI-PHARM, California, USA)) and control group (Elite Cement $100^{TM}$ (GC, Tokyo, Japan) ) were mixed and cured according to the manufacturer's instructions on the custom made split-type metal mold. A total of 150 specimens of each cement were prepared and each specimen (purity over 99%) was placed side-by-side with an aluminum step wedge for image taking with Intraoral X-ray unit (Esx, Vatech, Korea) and digital X-ray sensor (EzSensor, Vatech, Korea). For the evaluation of aluminum wedge equivalent thickness (mm Al), ImageJ 1.47 m (Wayne Rasband, National Institutes of Health, USA) and Color inspector 3D ver 2.0 (Interaktive Visualisierung von Farbraumen, Berlin, Germany) programs were used. Result: Among the 5 cements, Elite cement $100^{TM}$ (control group) showed the highest radio-opacity in all thickness. In the experimental group, $InterCem^{TM}$ had the highest radio-opacity followed by $Premier^{(R)}$ Implant $Cement^{TM}$, $Cem-Implant^{TM}$ and Estemp $Implant^{TM}$. In addition, $InterCem^{TM}$ showed radio-opacity that met the ISO No. 4049 standard in all the tested specimen thickness. Cem-Implant on 0.5 mm thickness showed radiopacity that met the ISO No. 4049 standard. Conclusion: Among the implant resin-based cements tested in the study, $Premier^{(R)}$ Implant Cement and Estemp $Implant^{TM}$ did not show appropriate radio-opacity. Only $InterCem^{TM}$ and $Cem-Implant^{TM}$ 0.5 mm specimen had the proper radiopacity and met the experiment standard.

THE STUDY ON THE IMPLANT GEOMETRY (3종의 임프란트 형태에 관한 연구)

  • Lee, Yong-Chan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.2
    • /
    • pp.245-252
    • /
    • 1996
  • The purpose of this study was to develop the implant which has superior stress distribution and primary stability to others by using Instron test and finite element method. The model used in the experiment were cylinder type implant, tapered screw type implant, screw type implants. Recognizing that the number of samples were small and the lack of applying press-fit conditions to the cylinder type, we can make the following conclusions.

  • PDF

A Fixed Bridge with Free Design Blade Implant (Free Design Blade Implant를 이용한 교의치)

  • Choie, Mok-Kyun;Lee, Bong-Won;Kim, Seung-Ki
    • The Journal of the Korean dental association
    • /
    • v.19 no.11 s.150
    • /
    • pp.975-979
    • /
    • 1981
  • In May 1981, the author placed Free Design Blade Implant into a 24-year old female patient with missing teeth of lower left molars, who did not want a removable partial denture. The bone available was good enough and in apparent general good health. The implant bridge was mad by four units, from 1st premolar to implant head, which is now in good esthetics and function.

  • PDF

Adhesion of Plasma Spray Coated Hydroxyapatite Film on the Two-Step Anodized Dental Implant

  • Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.05a
    • /
    • pp.126-126
    • /
    • 2012
  • In this study, adhesion of plasma spray coated hydroxyapatite film on the two-step anodized dental implant was investigated. The plasma spray was carried out on the dental implant after two step anodization. The adhesion of coated HA film was investigated by FE-SEM after fatigue test. In the case of two-step anodized implant showed a good adhesion between implant and coated film.

  • PDF