• Title/Summary/Keyword: IMAX

Search Result 18, Processing Time 0.024 seconds

Technology Status and Improvement Direction of Special Theaters in Korea by Format (국내 특수상영관 포맷별 기술현황과 개선방향)

  • Jung, Hyun-Jin
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.4
    • /
    • pp.73-87
    • /
    • 2021
  • Special theaters were created to provide a sense of immersion and spectacles due to differentiated screens, sound, seating facilities, and advanced services, and also expanded screens. The purpose of this study is to perform comparative analysis of the technical characteristics formats shown in special theaters(3D film, 4DX, IMAX, ScreenX, and VR) in order to identify and find ways to overcome the technological limitations in production. The various formats show differences in field of view depending on the exhibition technology and these differences affect the mise-en-scene, narrative, and editing of the film and consequently result in changes in the production environment and process. Therefore, directors and creators must understand the technological features and limitations of the new formats before making their approach. However, a new format encounters limitations on production sets due to the decline of technical education and succession. In situations where shooting with a special camera is essential, the particular characteristics of each format should be carefully considered from the planning stage but financial problems arise due to increase in production period and cost. To overcome these various obstacles, it is essential to first identify problems and present alternatives through in-depth research on the production set of each format. Finally, this research aims to explore the prototype of each format and analyze the current state of production technology with formats that have not been adapted to the market trends by combining with the other formats and showing that they can survive in new ways.

Ordering Kinetics of Triblock Copolymer/Low Molecular Weight Homopolymer Mixtures (삼중블록공중합체와 저분자량 단일중합체 혼합물의 미세상분리 동력학)

  • 차국헌
    • The Korean Journal of Rheology
    • /
    • v.10 no.2
    • /
    • pp.65-73
    • /
    • 1998
  • 본연구에서는poystyrene-block-poly (ethlene-co-butylene)-block-polystyrene(SEBS) 삼중블록 공중합체와 저분자량 단일중합체인 Hercotac 1149 (H1149)의 70/30 (w/w) 혼합물 의 미세상분리와 그동력학을 유변물성 측정법과 SAXS 실험을 통하여 연구해 보았다. 먼저 혼합물의 미세상분리 온도를 유변물성 측정법과 SAXS 실험을 통해 각각구한 다음 샘플을 미세상분리 온도보다 높은 온도에서 그이하의 온도로 급냉시킨 후 유변물성과 산란강도의 사간에 따른 변화로부터 미세상분리 동력학에 대한 정보를 구하였다. 이렇게 얻어진 데이터 를 Avrami 형태의 핵생성 성장(NG) 메커니즘으로 해석해 보았는데 최대산란강도 Imax 뿐만 아니라 저장 점탄성계수 G'과 손실 점탄성계수 G"의 시간에 따른 변화를 잘 예측할수 있 었다. 한편 서로다른 두 time-resolved 실험으로부터 Avrami 플롯을 그려서 구해진 Avrami 변수들은 같은 급냉 깊이에서는 서로 잘 일치함을 확인하였다. 반감기는 급냉 깊이가 증가 함에 따라 점차 감소하는 경향을 보였는데 이는 급냉 깊이가 클수록 미세상분리가 더 빨리 진행되고 있음을 보여주는 것이다. 또한 Avrami 지수는 급냉 깊이가 증가함에 따라 3에서 4로 급격히 변했는데 이로부터 급냉 깊이가 작을 때에는 70/30 (w/w) SEBS/H1149 혼합물 의 미세상분리가 불균일 핵생성 성장 메커니즘에 따라 진행되고 급냉 깊이가 더 커지면 미 세상분리가 스피노달 상분리 메커니즘으로 변하고 있음을 예측할수 있었다.

  • PDF

Quantitative analysis of the effect of fraction of inspired oxygen on peripheral oxygen saturation in healthy volunteers

  • Kang, Bong Jin;Kim, Myojung;Bang, Ji-Yeon;Lee, Eun-Kyung;Choi, Byung-Moon;Noh, Gyu-Jeong
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.2
    • /
    • pp.73-81
    • /
    • 2020
  • Background: The international organization for standardization (ISO) 80601-2-61 dictates that the accuracy of a pulse oximeter should be assessed by a controlled desaturation study. We aimed to characterize the relationship between the fraction of inspired oxygen (FiO2) and peripheral oxygen saturation (SpO2) using a turnover model by retrospectively analyzing the data obtained from previous controlled desaturation studies. Materials and Methods: Each volunteer was placed in a semi-Fowler's position and connected to a breathing circuit to administer the hypoxic gas mixture containing medical air, oxygen, nitrogen, and carbon dioxide. Volunteers were exposed to various levels of induced hypoxia over 70-100% arterial oxygen saturation (SaO2). The study period consisted of two rounds of hypoxia and the volunteers were maintained in room air between each round. FiO2 and SpO2 were recorded continuously during the study period. A population pharmacodynamic analysis was performed with the NONMEM VII level 4 (ICON Development Solutions, Ellicott City, MD, USA). Results: In total, 2899 SpO2 data points obtained from 20 volunteers were used to determine the pharmacodynamic characteristics. The pharmacodynamic parameters were as follows: kout = 0.942 1/min, Imax = 0.802, IC50 = 85.3%, γ = 27.3. Conclusion: The changes in SpO2 due to decreases in FiO2 well explained by the turnover model with inhibitory function as a sigmoidal model.

Analysis of Directing Super Hero Action Thriller (슈퍼 히어로 액션 스릴러 <다크 나이트>의 연출 분석)

  • Lee, Jeong-Gook
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.140-154
    • /
    • 2011
  • Through this thesis, I intended to analyze superhero action thriller through that achieved in art and box office after the film release. I would to access about it centering around directing viewpoint. of Christoper Nolan is evaluate as 'upgraded excellent action thriller'that have remarkable theme and excellent visual. Analysis of directing'll classify both contents and form. See about contents... theme of existential dilemma about the good and the evel, characters who is grew more powerful, and deeper than Batman series in old times. the fifth plot, especially dramatic plot by Joker's game, and various irony and motif. About form... efficient use of IMAX camera, prominence of action directing about car chase and fighting... better editing and music and art than former super hero series. The most important merit of is it's a philosophical theme. It is dipicted very seriously and successfully. First of all, the film has more advanced technique power and new directing style.

Study on corrosion fatigue of high strength steel (고장력강의 부식피로에 관한 연구)

  • 유헌일;천기정;택목양삼
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.5 no.1
    • /
    • pp.32-44
    • /
    • 1983
  • In case of $K_{Imax}$ < $K_{Iscc}$, the corrosion fatigue of high strength steel in 0.1N $H_{2}$S $O_{4}$ solution and 3.5% salt water is as follows. 1. The fatigue life shortens in order of 3.5% salt water and 0.1N $H_{2}$S $o_{4}$ solution. 2. The fatigue crack growth rate in air is obtained as the following equation. (dc/dN)$_{atr}$=7.23*10$^{-6}$ (.DELTA. K)$^{2.23}$ 3. The corrosion fatigue crack growth rate in environment is divided into three regions, that is, First Region, Second Region and Third Region from the small cyclic stress intensity. 4. The formation rate of the active surface on metal is slower than the mechano-chemical reaction rate in First Region. The crack growth rate depends on time and the cyclic stress intensity and is expressed as the following equation. (dc/dN)$_{I}$=C(/DELTA. K)$^{\delta}$ 5. The formation rate of the active surface is faster than the mechano-chemical reaction rate in Second Region and the synergistic effect by stress and corrosion becomes slow. In case the fatigue load is large, we have the critical crack growth rate which is not related to the cyclic stress intensity. 6. The corrosion crack growth rate by the mechano-chemical reaction is the same in $H_{2}$S $O_{4}$ solution and salt water, so Hydrogen accelerates the crack growth. 7. The environment has no effect on the corrosion fatigue crack growth rate in Third Region. 8. In First Region and Second Region, dimple is observed on the fatigue fracture surface in 0.1N $H_{2}$S $O_{4}$ solution. 9. The striation is observed in any environment as in air in Third Region and its interval approximately coincide with the crack growth rate.ate.e.e.

  • PDF

Contrast Media in Abdominal Computed Tomography: Optimization of Delivery Methods

  • Joon Koo Han;Byung Ihn Choi;Ah Young Kim;Soo Jung Kim
    • Korean Journal of Radiology
    • /
    • v.2 no.1
    • /
    • pp.28-36
    • /
    • 2001
  • Objective: To provide a systematic overview of the effects of various parameters on contrast enhancement within the same population, an animal experiment as well as a computer-aided simulation study was performed. Materials and Methods: In an animal experiment, single-level dynamic CT through the liver was performed at 5-second intervals just after the injection of contrast medium for 3 minutes. Combinations of three different amounts (1, 2, 3 mL/kg), concentrations (150, 200, 300 mgI/mL), and injection rates (0.5, 1, 2 mL/sec) were used. The CT number of the aorta (A), portal vein (P) and liver (L) was measured in each image, and time-attenuation curves for A, P and L were thus obtained. The degree of maximum enhancement (Imax) and time to reach peak enhancement (Tmax) of A, P and L were determined, and times to equilibrium (Teq) were analyzed. In the computed-aided simulation model, a program based on the amount, flow, and diffusion coefficient of body fluid in various compartments of the human body was designed. The input variables were the concentrations, volumes and injection rates of the contrast media used. The program generated the time-attenuation curves of A, P and L, as well as liver-to-hepatocellular carcinoma (HCC) contrast curves. On each curve, we calculated and plotted the optimal temporal window (time period above the lower threshold, which in this experiment was 10 Hounsfield units), the total area under the curve above the lower threshold, and the area within the optimal range. Results: A. Animal Experiment: At a given concentration and injection rate, an increased volume of contrast medium led to increases in Imax A, P and L. In addition, Tmax A, P, L and Teq were prolonged in parallel with increases in injection time The time-attenuation curve shifted upward and to the right. For a given volume and injection rate, an increased concentration of contrast medium increased the degree of aortic, portal and hepatic enhancement, though Tmax A, P and L remained the same. The time-attenuation curve shifted upward. For a given volume and concentration of contrast medium, changes in the injection rate had a prominent effect on aortic enhancement, and that of the portal vein and hepatic parenchyma also showed some increase, though the effect was less prominent. A increased in the rate of contrast injection led to shifting of the time enhancement curve to the left and upward. B. Computer Simulation: At a faster injection rate, there was minimal change in the degree of hepatic attenuation, though the duration of the optimal temporal window decreased. The area between 10 and 30 HU was greatest when contrast media was delivered at a rate of 2 3 mL/sec. Although the total area under the curve increased in proportion to the injection rate, most of this increase was above the upper threshould and thus the temporal window was narrow and the optimal area decreased. Conclusion: Increases in volume, concentration and injection rate all resulted in improved arterial enhancement. If cost was disregarded, increasing the injection volume was the most reliable way of obtaining good quality enhancement. The optimal way of delivering a given amount of contrast medium can be calculated using a computer-based mathematical model.

  • PDF

Studies on Fabrication and Characteristics of $Al_{0.3}Ga_0.7N/GaN$ Heterojunction Field Effect Transistors for High-Voltage and High-Power Applications (고전압과 고전력 응용을 위한 $Al_{0.3}Ga_0.7N/GaN$ 이종접합 전계효과 트랜지스터의 제작 및 특성에 관한 연구)

  • Kim, Jong-Wook;Lee, Jae-Seung;Kim, Chang-Suk;Jeong, Doo-Chan;Lee, Jae-Hak;Shin, Jin-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.8
    • /
    • pp.13-19
    • /
    • 2001
  • We report on the fabrication and characterization of $Al_{0.3}Ga_{0.7}N$ HFETs with different barrier layer thickness which were grown using plasma-assisted molecular beam epitaxy (PAMBE). The barrier thickness of $Al_{0.3}Ga_{0.7}N$/GaN HFETs could be optimized in order to maximize 2 dimensional electron gas induced by piezoelectric effect without the relaxation of $Al_{0.3}Ga_{0.7}N$ layer. $Al_{0.3}Ga_{0.7}N$/GaN (20 nm/2 mm) HFET with 0.6 ${\mu}m$-long and 34 ${\mu}m$-wide gate shows saturated current density ($V_{gs}=1\;V$) of 1.155 A/mm and transconductance of 250 ms/mm, respectively. From high frequency measurement, the fabricated $Al_{0.3}Ga_{0.7}N$/GaN HFETs showed $F_t=13$ GHz and $F_{max}=48$ GHz, respectively. The uniformity of less than 5% could be obtained over the 2 inch wafer. In addition to the optimization of epi-layer structure, the relation between breakdown voltage and high frequency characteristics has been examined.

  • PDF

The Differences in Resting Pulmonary Function in Relation to the Nutritional status of Patients with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환 환자의 영양상태에 따른 안정시 폐기능 차이)

  • Mun, Yeung-Chul;Yu, Sung-Keun;Park, Hye-Jung;Park, Jong-Won;Shin, Kyeong-Cheol;Chung, Jin-Hong;Lee, Kwan-Ho;Kim, Jung-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.6
    • /
    • pp.570-578
    • /
    • 2001
  • Background: With cases of chronic obstructive pulmonary disease(COPD), weight loss and low body weight have been found to correlate with increased mortality and poor prognosis. Therefore, nutritional aspects are an important part of the treatment in cases of COPD. In Korea, there is only limited data available for the changes of resting pulmonary function in relation to nutritional status. This study was carried out to investigate the differences of resting pulmonary function in relation to the nutritional status of patients with COPD. Method : 83 stable patients, with moderate to severe COPD, were clinically assessed for their nutritional status and resting pulmonary function. The patients' nutritional status was evaluated by body weight and fat-free mass (FFM), which was assessed by bioelectrical impedance analysis. According to their nutritional status, the 83 patients were divided into two groups, designated as the depleted, and non-depleted, groups. Result : Of the 83 patients, 31% were characterized by body weight loss and depletion of FFM, whereas 28% had either weight loss or depleted FFM. In the depleted group, significantly lower peak expiratory flow rate(p<0.05) and Kco(p<0.01), but significantly higher airway resistance(Raw, p<0.05) were noted. There was no difference for the non-depleted group in forced expiratory volume at one second, residual volume, inspiratory vital capacity, or total lung capacity. Maximal inspiratory pressure($P_{Imax}$) was also significantly lower in the depleted group(p<0.05). Conclusion : We conclude, from our clinical studies, that nutritional depletion is significantly associated with the change in resting pulmonary function for patients with moderate to severe COPD.

  • PDF