A Feasibility Study for Application of Single-Chip Solution for Diagnostic Resting ECG (ECG 원칩 솔루션의 진단용 심전계 적용을 위한 타당성 연구)

  • Kang, Bum-Sun;Choi, Gi Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.86-94
    • /
    • 2015
  • In order for medical devices to be used outside hospital, they have to be not only of small size but also power consumption has to be kept at low level. This study investigates the feasibility of application of ADS1298 ECG single-chip solution developed by Texas Instruments Inc. for use in development of a new platform for diagnostic resting ECG. To prove the feasibility of commercial products based on the ADS1298 chip, the performance of the ADS1298 chip was measured in terms of input impedance, common mode rejection, frequency response, and input dynamic range using the testing method under the suitability criteria of the IEC 60601-2-25 standard. Result of the this study shows that commercialization of the ECG products based on the ADS1298 ECG single-chip solution that satisfies the international standards would be possible, if the manufactures take the filter characteristics into account in building a new platform for diagnostic resting ECG.

The Protective Co-ordination between Low-Voltage Circuit-Breaker (저압차단기기의 보호협조)

  • Park, S.C.;Oh, J.S.;Lee, B.W.;Ryu, M.J.;Seo, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.340-343
    • /
    • 2001
  • In an electrical network, electrical power are transmitted by a various of protection, isolation and control electric circuit devices. This thesis deals with the protection function between circuit-breakers. The protective coordination concerns the behaviour of two devices placed in series in an electrical network, with a short-circuit downstream circuit-breaker. It has two basic principles: First, discrimination which is an increasing requirement of low voltage electrical distribution systems. Second, which is less well known: cascading, which consists of installing a device, whose breaking capacity is less than the three-phase short-circuit current at its terminals and helped by main circuit-breaker. The important advantage of cascading is to be able to install at a branch circuit-breaker of a lesser performance without endangering the safety of the installation for more economical usage. To determine and guarantee co-ordination between two circuit breakers, it is necessary to carry out a theoretical approach, first, and then confirm the results by means of standard tests. This is illustrated in appendix A of IEC 947-2.

  • PDF

Efficiency measuring in pump using Thermodynamic method (열역학법에 의한 펌프의 수력효율측정)

  • Kwon, Young June;Seo, Chang Deok;Jung, Yong Chea;Park, Jang Won
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.546-551
    • /
    • 2004
  • An applying Thermodynamic method for the purpose of measuring hydraulic efficiency of pump-motor system, based on IEC60041 code, is not easy to adopt at field test. Even though there were splendid development in measuring technic in discharge measuring through the hydraulic machina lots of unsolved problems concerned in flow-rate are still remain in measuring hydraulic efficiency in hydraulic machine. The key point in measuring hydraulic efficiency is to measure exact flow-rate. So, Thermodynamic methode provides a good solution. This methode measures hydraulic efficiency by detecting the difference of temperature and pressure between the hydraulic process of machine, without measuring flow-rate of pump or turbine. By measuring temperature in mk level and absolute pressure in pascal, we can get a difference of thermodynamic specific energy in Moliere chart before and after of hydraulic process, md that difference is equal to hydraulic loses. Following the standard in proceeding Thermodynamic methode, I hope these trial and records make others be familiar to the thermal methode and make it easer to beginner for trial.

  • PDF

Experimental study on the effects of EVA(Ethylene Vinyl Acetate) for solar cell's long-term life (EVA(Ethylene Vinyl Acetate) 수지가 태양전지의 장기적인 수명에 미치는 영향에 관한 실험적 연구)

  • Kim, Seon Yong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.397-401
    • /
    • 2015
  • In this study, analysed the characteristics of power drop and surface damage in solar cell through high temperature and humidity test in the 3 case of EVA(ethylene vinyl acetate) and 2 case ribbon thickness. The solar cells were tested during the 500hr in $85^{\circ}C$ temperature and 85% relative humidity conditions, that excerpted standard of PV Module(KS C IEC-61215). Through the EL(Electroluminescence) shots, specimen's surface have partialy damaged. Before and after high humidity and high temperature test, ribbon thickness $200{\mu}m$ EVA1 case power drop rate was 8.463%, EVA2 case was 6.667%, EVA3 case was 6.373%. In the ribbon thickness $250{\mu}m$ EVA1 case power drop rate was 6.521%, EVA2 case was 8.517%, EVA3 case was 6.019%. EVA3 case was the lowest power and FF(fill factor) drop rate at the 2 case of ribbon thickness, because EVA3 is laerger than EVA1 and EVA2 in thickness, elongation and tensile strength.

An Assessment Study for Design Load of a Small Wind Turbine (소형풍력발전기의 설계하중 평가 연구)

  • Hyun, Seung-Gun;Kim, Keon-Hoon;Huh, Jong-Chul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.48-53
    • /
    • 2011
  • In this study, it is to verify the applicability for a simplified model(IEC61400-2, Design Require-ments for Small Wind Turbines, 2006-03) is the international standard is used to the structural design. In the design process of a wind turbine, the safety of a designed wind turbine is one of the most important factors. The simplified model can be used to determine the design load for small wind turbines. So, this paper has been re-evaluated a small wind turbine design loads that produced already. As a result, the material characteristic value(Rchar) of Blade, Rotor shaft and the tower are $90E6[N/m^2]$, $441E6[N/m^2]$ and $94E6[N/m^2]$. Therefore, the value of the applied safety factor to each part of the survival probability of 95% are satisfied.

  • PDF

A Study on the SIL Allocation and Demonstration for Train Control System (열차제어시스템 SIL할당 및 입증에 관한 연구)

  • Shin, Duc-Ko;Baek, Jong-Hyen;Lee, Kang-Mi;Lee, Jae-Ho
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.855-859
    • /
    • 2009
  • In this paper, we introduce the estimation method by Risk or SIL(Safety Integrity Level) for the criterion of safety assurance and summarize each application method and target. IEC 62278(EN 50126) which is international standard for the specification and verification of the railway system RAMS indicate a criterion of safety assurance. Especially, it recommend the safety verification by continuous verification as the order of requirement establishment, design, manufacture, installation, operation, and maintenance for the equipment not easy to quantify the operation environment. In this paper, we study the SIL requirement allocation method relating to internal new system development and existing system improvement by analysing SIL recommendations which were used to understand SIL for a train control equipment in 1990s in IRSE and theoretically their allocation background. This paper help the safety management of Korea train control system to develope the quantitative management procedure as international level by analyzing the SIL requirement allocation by operation agency and the right SIL verification procedure by manufacture and indicating the example to assure safety because it is necessary for improvement and localization for the Korea train control system having highly dependence on aboard technology.

  • PDF

Three-Dimensional Computational Flow Analysis on Meteorological-Tower Shading Effect (풍황탑 차폐영향 분석을 위한 3차원 전산유동해석)

  • Rhee, Hui-Nam;Kim, Tae-Sung;Jeon, Wan-Ho;Kim, Hyun-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • It is difficult to avoid measurement errors caused by the shading effect of the meteorological tower, which is used for wind resource assessment according to the IEC Standard. This paper presents a validation of the computational flow analysis results by comparing the results with the wind tunnel experiment conducted for Reynolds numbers in the $10^4$ to $10^5$ range, for the preparation of a database for use in an automatic method of correcting met-tower shading errors. A three-dimensional simulation employing the MP (Modified Production) $k-{\varepsilon}$ turbulence model predicted a wind speed deficit in the wake region according to minimum wind speed ratio, within an MAE (Mean Absolute Error) of 2.4%.

A study on RFID code system for Traceability of agro-livestock products (농축산물 생산 이력 정보 추적을 위한 RFID 코드체계에 관한 연구)

  • Park, Min-Ho;Ko, Sung-Seok
    • The Journal of Society for e-Business Studies
    • /
    • v.12 no.2
    • /
    • pp.95-110
    • /
    • 2007
  • The agro-livestock industry is composed of a complicated supply chain and the customer‘s interest in safety of agro-livestock products is increasing. In order to provide customer with the accurate information about the history of product, and make good use of these information, traceability systems based on RFID technology were implemented and are planned. It is, however, difficult to make the efficient flow of information and to enhance or expand the traceability system because of the lack of the standard of RFID code system. To overcome this problem, we propose a RFID code system for the traceability of argo-livestock products on the basis of ISO/IEC 15459 KKR code system.

  • PDF

Optimum Design Methodology of the Damped Oscillatory Impulse Current Generator Considering a Nonlinear Load (비선형 부하를 고려한 감쇠 진동형 임펄스 전류발생기의 설계 기법)

  • Chang, Sug-Hun;Lee, Jae-Bok;Shenderey, S.V.;Myung, Sung-Ho;Cho, Yuen-Gue
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2255-2262
    • /
    • 2008
  • This paper presents a design parameter calculation methodology and its realization to construction for the damped oscillatory impulse current generator(ICG) modelled as damping factor $\alpha$. Matlab internal functions, "fzero" and "polyfit" are applied to find a which are solutions of second order nonlinear equation related with three wave parameters $T_{1},T_{2}$ and $I_{os}$. The calculation results for standard impulse current waveforms such as 4/10${\mu}s$, 8/20${\mu}s$ and 30/80${\mu}s$ show very good accuracy and this results make it possible to extend to generalization in the design of damped oscillatory lCG with any capacitor. 8/20${\mu}s$ ICG based on the calculated design circuit parameters is fabricated in consideration of the nonlinear load(MOV) variation. Comparisons of the tested waveforms with the designed estimation show error within 10% for the waveform tolerance recommended in IEC 60060-1 and IEEE std. C62.45.

Synthesis and Properties of High Voltage Silicone Rubber by Platinum-based Flame Retardant

  • Jung, Se-Young;Kim, Byung-Kyu
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.6
    • /
    • pp.283-292
    • /
    • 2006
  • So that high-strength and electrical properties apply by excellent high voltage insulator electricity material, ATH content and platinum-based flame retardant that influence in flame retardant and tracking characteristic among composite of silicone rubber studied mechanical strength and influence getting to electrical properties. Composition of ${\alpha}$, ${\omega}-vinyl$ poly (dimethyl-methylphenyl) siloxane(VPMPS) of a polymer quantity made doing mole of D4, $D3^{Me,Ph}$ and VMS by 1000:15:0.2 mole ratio and uses basic catalyst tetramethylammonium silanolate(TMAS) and do opening equilibrium polymerization to be used to main polymer for high voltage insulation insulator. Control ATH content and content of platinum-based flame retardant and made high voltage insulation silicone rubber. Measured mechanical strength of making silicone rubber using UTM, and tracking characteristic according to standard of IEC 60587, flame retardant test studied effect that flame retardant characteristic gets in tracking characteristic, measuring according to UL94V method of test.