• Title/Summary/Keyword: IEC Rule

Search Result 28, Processing Time 0.031 seconds

Analysis On Security and Dependability for IED System in SAS (변전소 IED의 보안과 신뢰성에 관한 고찰)

  • Guan, Qiang;Han, Seung-Soo;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.21-23
    • /
    • 2006
  • As a general rule for evaluating dependability of a system, reliability is commonly considered which barely rays attention to the system behavior, however the estimation is based on the assumption of a fault-frost system, which may be impracticable and inaccurate especially for complicated system. This paper introduces a security and dependability integrated approach to analyze the availability of a fault-active system both from dependability and security points of view. Two fault modes involved are discussed about the impairment to the system reliance. The approach can be well applied to estimate and quantify the attribute of system robustness with the help of Markov chain process, which is good at solving status related problem. The comparison result between dual system and IEC61850-based almighty backup system is shown to sup-port the suggested approach.

  • PDF

Structural Analysis and Testing of 1.5kW Class Wind Turbine Blade (1.5kW급 풍력발전기용 블레이드의 구조해석 및 구조시험)

  • Kim, Hong-Kwan;Lee, Jang-Ho;Jang, Se-Myong;Kang, Ki-Weon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.51-57
    • /
    • 2010
  • This paper describes the structural design and testing for 1.5kW class wind turbine composite blade. In order to calculate the equivalent material properties rule-of-mixture is applied. Lay-up sequence, ply thickness and ply angle are designed to satisfy the requirements for structural integrity. Structural analysis by using commercial software ABAQUS is performed to assess the static, buckling and vibration response. And to verify the structural analysis and design, the full scale structural test in flapwise direction was performed under single point loading according to loading conditions calculated by the aerodynamic analysis and Case H (Parked wind loading) in IEC 61400-2.

Formulation of a New En Score in the Proficiency Test

  • Chul-Young Yi;In Jung Kim;Jong In Park;Yun Ho Kim;Young Min Seong
    • Progress in Medical Physics
    • /
    • v.35 no.1
    • /
    • pp.16-19
    • /
    • 2024
  • A new En score of the proficiency test (PT) is formulated; it is applicable when a correlation exists between the reference and participant's values. Based on the uncertainty propagation rule given in ISO/IEC Guide 98-3 (GUM:1995), the En score covering the correlation case is newly developed for the PT. The new En score will be applied in a future PT organized by the Korea Research Institute of Standards and Science (KRISS) dosimetry team. The new En score will enhance measurement traceability and contribute to improving the quality management system of participants in the KRISS PT by avoiding performance underestimation.

Testing and Analysis of Tube Voltage and Tube Current in The Radiation Generator for Mammography (유방촬영용 방사선발생장치의 관전압과 관전류 시험 분석)

  • Jung, Hong-Ryang;Hong, Dong-Hee;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Breast shooting performance management and quality control of the generator is applied to the amount of current IEC(International Electrotechnical Commission) 60601-2-45 tube voltage and tube current are based on standards that were proposed in the analysis of the test results were as follows. Tube voltage according to the value of the standard deviation by year of manufacture from 2001 to 2010 as a 42-3.15 showed the most significant, according to the year of manufacture by tube amperage value of the standard deviation to 6.38 in the pre-2000 showed the most significant, manufactured after 2011 the standard deviation of the devices, the PAE(Percent Average Error) was relatively low. This latest generation device was manufactured in the breast of the tube voltage and tube diagnosed shooting the correct amount of current to maintain the performance that can be seen. The results of this study as the basis for radiography diagnosed breast caused by using the device's performance and maintain quality control, so the current Food and Drug Administration "about the safety of diagnostic radiation generator rule" specified in the test cycle during three years of self-inspection radiation on a radiation generating device ensure safety and performance of the device using a coherent X-ray(constancy) by two ultimately able to keep the radiation dose to the public to reduce the expected effect is expected.

A Study on the Naming Rules of Metadata based on Ontology (온톨로지 기반 메타데이터 명명 규칙에 관한 연구)

  • Ko, Young-Man;Seo, Tae-Sul
    • Journal of the Korean Society for information Management
    • /
    • v.22 no.4 s.58
    • /
    • pp.97-109
    • /
    • 2005
  • To build the consistency among different metadata systems and to increase the interoperability of that systems even among different domains, naming rules and glossaries for the data elements are necessary. This study provides discussion of naming and identification of the data element concept, data element, conceptual domain, value domain, and its meta model. This study also describes example naming conventions based on ontology derived from the combination with object, properties, and representation of data elements. The naming principles and rules described in this study use I-R analysis, DC metadata set, and SHOE 1.0 as an example of the scientific documents. This study would be a guideline to build the naming rules of metadata based on ontology in various domains.

Structural Design and Experimental Investigation of A Medium Scale Composite Wind Turbine Blade Considering Fatigue Life (피로 수명을 고려한 중형 복합재 풍력터빈 블레이드의 구조설계 및 실험 평가)

  • Gong, Chang Deok;Bang, Jo Hyeok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.3
    • /
    • pp.23-30
    • /
    • 2003
  • In this study, the various load cases by specified by the IEC61400-1 international specification and GL Regulations for the wind energy conversion system were considered, and a specific composite structure configuration which can effectively endure various loads was proposed. In order to evaluate the structure, the structural analysis for the composite wind turbine blade was performed using the finite element method(FEM). In the structural design, the acceptable configuration of blade structure was determined through the parametric studies, and the most dominant design parameters were confirmed. In the stress analysis using the FEM, it was confirmed that the blade structure was safe and stable for all the considerd load cases. Moreover the safety of the blade root joint with insert bolts, newly devised in this study, was checked against the design loads and also the fatigue loads. The fatigue life for operating more than 20 years was estimated by using the well-known S-N linear damage rule, the load spectrum and Spera's empirical equations. The full-scale static test was performed under the simulated aerodynamic loads. from the experimental results, it was found that the designed blade had the structural integrity. Furthermore the measured results were agreed with the analytical results such as deflections, strains, the mass and the radial center of gravity. The studied blade was successfully certified by an international institute, GL, of Germany.

A Study on SIL Allocation for Signaling Function with Fuzzy Risk Graph (퍼지 리스크 그래프를 적용한 신호 기능 SIL 할당에 관한 연구)

  • Yang, Heekap;Lee, Jongwoo
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.2
    • /
    • pp.145-158
    • /
    • 2016
  • This paper introduces a risk graph which is one method for determining the SIL as a measure of the effectiveness of signaling system. The purpose of this research is to make up for the weakness of the qualitative determination, which has input value ambiguity and a boundary problem in the SIL range. The fuzzy input valuable consists of consequence, exposure, avoidance and demand rate. The fuzzy inference produces forty eight fuzzy rule by adapting the calibrated risk graph in the IEC 61511. The Max-min composition is utilized for the fuzzy inference. The result of the fuzzy inference is the fuzzy value. Therefore, using the de-fuzzification method, the result should be converted to a crisp value that can be utilized for real projects. Ultimately, the safety requirement for hazard is identified by proposing a SIL result with a tolerable hazard rate. For the validation the results of the proposed method, the fuzzy risk graph model is compared with the safety analysis of the signaling system in CENELEC SC 9XA WG A10 report.

CDISC Transformer: a metadata-based transformation tool for clinical trial and research data into CDISC standards

  • Park, Yu-Rang;Kim, Hye-Hyeon;Seo, Hwa-Jeong;Kim, Ju-Han
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.10
    • /
    • pp.1830-1840
    • /
    • 2011
  • CDISC (Clinical Data Interchanging Standards Consortium) standards are to support the acquisition, exchange, submission and archival of clinical trial and research data. SDTM (Study Data Tabulation Model) for Case Report Forms (CRFs) was recommended for U.S. Food and Drug Administration (FDA) regulatory submissions since 2004. Although the SDTM Implementation Guide gives a standardized and predefined collection of submission metadata 'domains' containing extensive variable collections, transforming CRFs to SDTM files for FDA submission is still a very hard and time-consuming task. For addressing this issue, we developed metadata based SDTM mapping rules. Using these mapping rules, we also developed a semi-automatic tool, named CDISC Transformer, for transforming clinical trial data to CDISC standard compliant data. The performance of CDISC Transformer with or without MDR support was evaluated using CDISC blank CRF as the 'gold standard'. Both MDR and user inquiry-supported transformation substantially improved the accuracy of our transformation rules. CDISC Transformer will greatly reduce the workloads and enhance standardized data entry and integration for clinical trial and research in various healthcare domains.