• Title/Summary/Keyword: IEC 61970

Search Result 17, Processing Time 0.034 seconds

A Study on the Model of A Electric Railway Substation Automation Based on IEC 61850 and IEC 61970 (IEC 61850과 IEC 61970을 표준으로 하는 전철변전소 종합자동화 모델에 관한 연구)

  • Ko, Chung-Ku;Jang, Woo-Jin;Choi, Kyu-Hyoung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1014-1019
    • /
    • 2011
  • The substation automation is a system to remote-monitor and control electric power flow. And in line with electrification of railway, an interest in electric railway substation automation is increasing. IEC standardized IEC 61850, IEC 61968 and IEC 61970 communication protocol for the telecommunication standardization of the electric power automation industry. The recent SCADA systems in managed electric railway substations are have the problem about the compatibility with the products which fit to the international standard specification afterward. In this paper, the model of electric railway substation automation based on IEC 61850 and IEC 61970 is presented. And the method supporting the compatibility between the equipment is proposed.

  • PDF

IEC 61968/61970 based Distribution Management System Suggestion (IEC 61968과 61970 기반의 배전운영 시스템 제안)

  • Kim, Taw-Wan;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Kwon, Sung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.231-238
    • /
    • 2011
  • A role of Distribution Automation System(DAS) is required to be changed from observing and control to complex and various new system including functions which monitoring, control, prediction, operation and management of EMS type according to be gradually Smart Grid of distribution operation system for development of further power system industrial. IEC(International Electrotechnical Commission) published communication standards which interface and data model of distribution operation system to IEC 61968 and of host system like EMS(Energy Management System) to IEC 61970. So far, each standards are emphasizing themselves, but if they are applied by designed integration of the standards, it could be more efficiency system. So, in this paper, integration application of IEC standards and structure of further distribution operation system to use them are proposed by gradually increasing importance of communication protocols, functions and roles in further distribution management system considering Smart Grid.

Designs of the Unified Information Model-IEC61850/IEC61970 and Topology Model for Smart Grid (스마트 그리드 망을 위한 IEC61970/IEC61850 통합 정보 모델과 토폴로지 모델 설계)

  • Yun, Seok-Yeul;Yim, Hwa-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.28-33
    • /
    • 2012
  • The smart grid, which is an integrated type of the power system and the digital network, requires the integration of a CIM(Common Information Model) standard for information modelling at the power control centers and an IEC 61850 standard for automation at the substation level in order to efficiently exchange the information between system elements. This paper describes the method of data transfer from one standard information model to the other standard unified information model by mapping between the objects of IEC 61850 and IEC61970 CIM standards both in the static and dynamic models, and designs the method of data transfer and information exchange between the topology processing application using unified topology class packages.

A study on an implementation of IEC 61970 based EMS database (IEC 61970 기반의 EMS 데이터베이스 구축에 관한 연구)

  • Lee, J.H.;Sohn, J.M.;Nam, Y.W.;Lee, Y.I.;Park, J.H.;Kim, P.S.;Kim, B.S.;Shin, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.323-325
    • /
    • 2006
  • 전력계통 에너지관리시스템(EMS)을 위한 공통 정보모델(CIM:Common Information Model)은 1990년대 후반에 EPRI의 CCAPI (Control Center Application Program Interface) 연구 프로젝트에서 시작하여, 현재는 IEC의 국제표준인 IEC 61970시리즈로 등록되어 있다. 특히, CIM은 IEC61970의 Part 301, 302에 정의되어 있는 공통데이터 모델을 지칭하며, IEC61970의 Part 401${\sim}$407에 정의되어 있는 CIS (Component Interface Specification)와 더불어 EMS의 API(Application Program Interface)를 정의하는 핵심 요소이다. CIM (Common Information Model)은 전격회사의 전력 시스템 운영을 포함하여 전력회사 전반에 사용되는 주요한 객체(object)들을 나타내는 추상적 모델(abstract model)이다. 또한, CIM은 전력계통 자원을 객체 클래스들(object classes)과 속성들(attributes)로 표현하는 표준 방법을 제공함으로써, 발전분야나 배전분야와 같이 전력 계통의 운용 영역이 다른 계통들과 EMS 시스템 연계, 독립적으로 개발된 전체 EMS 시스템간의 연계, 서로 다른 판매자에 의해서 독립적으로 개발된 EMS 응용 프로그램간의 통합을 용이하게 한다. 본 논문에서는 전력계통 공통 데이터 모델인 IEC 61970을 소개하고, 이에 기반을 둔 한국형 EMS 데이터베스 구축에 관해 설명한다.

  • PDF

Development of CIMToolkit based on IEC 61970/61968 for System IntegrationA Study on the Design of Testable CAM using MTA Code (시스템 통합을 위한 IEC 61970/61968 기반의 CIMToolkit 개발)

  • Heo, Dong-Uk;Seo, Jeong-Il;Han, Ju-Hyun;Son, Sung-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1473-1478
    • /
    • 2011
  • Since IT technology was combined with the power system, many systems and applications have been developed and also Integration between systems has been followed in order to meet much higher level. Futher more to reduce the cost of system integration there were needs standardized data model and interfaces among systems or applications. so IEC has reached to establish standard interfaces and data model. Most of the current distribution automation system in South Korea, each operating independently in an enclosed environment, are managed. As time goes by, however, because of resons that the system is increasingly complex by implenting new kind of power source and demand for electricity is rapidly increasing, it became difficult to predict with a independent data from one system. In this paper, In order to apply common infomation model and standard interfaces which are defined in IEC 61970/61968 to the exisiting distribution automation system in KEPCO, several software tools and applications which have been created will be introduced.

Introduction of International Standard Test Scenario of the SCADA System with CIM using IEC 61970 (IEC 61970 CIM 기반 SCADA 시스템 표준시험 시나리오)

  • Jang, B.T.;Lee, Y.J.;Lee, N.H.;Han, J.Y.;Kim, S.K.;Choi, J.K.;An, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.573-574
    • /
    • 2015
  • 스마트그리드 전력계통시스템 기술의 중요한 특징중의 하나는 국제표준을 기본으로 탑재하고 있다. 발전소부터 수용가까지 각 영역별로 운영중인 시스템들이 국제표준을 준수한다는 것은 어떤 특정임무만을 담당하는 독립된 시스템이 아닌 타 시스템에 정보를 주고 받는 분산시스템의 구조로 전력시스템 전체 아키텍쳐가 변화하고 있는 것이다. 이러한 환경은 ICT(Information & Communication Technology)와 매우 친화적이며 스마트그리드의 발전을 촉진시킨다. 전력회사마다 운영중인 송변전자동화시스템인 SCADA(Supervisory Control And Data Acquisition)에 대하여 IEC 61970 표준을 지원하는 기능을 갖춘 제품들이 세계시장에 급속히 공급되고 있어 표준을 기반으로 하는 이기종 제품간에 정보교환의 호환성을 검증하는 상호운용성 시험의 중요성이 커지고 있는 실정이다. 본 논문에서는 IEC 61970이 적용된 SCADA 시스템을 대상으로 표준기반의 상호운용성 시험에 대해 기술하고자 한다.

  • PDF

IEC 61970 CIM based Study on the application of model for Wide Area Monitoring And Control System (IEC 61970 CIM을 기반으로 한 Wide Area Monitoring And Control system 모델 적용 연구)

  • Cho, Jun-Hee;Oh, Young-Suk;Choi, Mi-Hwa;Shin, Seung-Hee;Kim, Ji-Young
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.178-179
    • /
    • 2011
  • The exchange of information with legacy systems is a main issue in the era of SMARTGRID. Because WAMAC(Wide Area Monitoring and Control) system has monitoring function, as well as control function, it is very necessary for WAMAC to exchange data and information with SCADA(Supervisory Control and Data Acquisition) / EMS(Energy Management System). IEC 61970 CIM(Common Information Model) is an abstract model that represents all the major objects in an electric utility enterprise typically involved in utility operations. In this paper, a proposal that adopting CIM to WAMAC model be submitted so that the integration of various legacy system and application for itself be able to be flexible.

  • PDF

K-Grid Integrated Data Modeling and Data Exchange Protocol Design and Evaluation (K-Grid 통합 노드 데이터 모델링 및 정보교환 프로토콜 설계와 시험)

  • Choi, Jung-In
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.119-131
    • /
    • 2011
  • To be integrated into the IEC 61970-based K-Grid, application of open communication protocol and sub-system modeling to major nodes is needed. In this paper, a module which links load nodes in customers to CIM based on psXML/oBIX, one of open protocols, was developed and data modeling and communication protocols of IEC 61850-7-42 based DER and ESS which apply the module to the customers who have DER and ESS were designed. Also the XML-based distributed database middleware was designed. The proposed modeling and protocols were applied to the building in which commercial DER products and the effectiveness of the proposed data modeling and the communication protocol were evaluated.

A Study on the Applying Standardized CIM-based model of Power System Application (전력계통 애플리케니션의 표준화된 CIM 기반 모델 적용 연구)

  • Lee, Jae-Won;Kim, Gun-Joong;Hwang, In-Jun;Yang, Min-Ook;Cho, Hwi-Cheng;Lee, Ji-Hye
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.288_289
    • /
    • 2009
  • 전력시스템은 시간이 지남에 따라서 부하의 증가와 다양한 설비기기의 투입, 지속적인 유지보수와 수요에 대한 예측이 필요하다. 이런 전력 시스템을 관리하기 위한 많은 애플리케이션들이 있으며 전력 시스템 애플리케이션을 위한 공통 정보모델 표준을 위한 IEC61970 국제 표준화 작업이 활발히 이루어지고 있다. 본 논문에서는 IEC61970 Part3 CIM(Common Information Model)의 적용을 위한 미들웨어 도입과 데이터베이스 모델 적용 방안에 대해서 알아본다.

  • PDF

Development of the Gateway in IEC61850 based Substation for Smart Grid (스마트 그리드용 IEC61850 기반 변전소에서의 게이트웨이 개발)

  • Yun, Seok-Yeul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1324-1330
    • /
    • 2011
  • This paper presents the development of gateway for smart grid for the interoperable communication between IEC 61850 station leveled devices and one of legacy Modbus, DNP3, and IEC60870-5-101/104/103 communication protocol devices of bay level in substation or for the exchange of information between IEC 61850 substation and SCADA control center. The data-mapping model is designed for the exchange of information and the gateway configuration tool is developed for generating meta-data based on XML Schema. this paper is mostly concerned with the design and realization of gateway system for the interoperable data communication between a legacy protocol device and IEC61850 based devices or systems.