• Title/Summary/Keyword: IEC 61850 Substation

Search Result 123, Processing Time 0.031 seconds

UsN based Soundness Monitoring Diagnosis System of Power Transmission Steel Tower (UsN 기반의 송전철탑 건전성 감시진단시스템 기본설계)

  • Lee, Dong-Cheol;Bae, Ul-Lok;Kim, Woo-Jung;Min, Bung-Yun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.56-62
    • /
    • 2007
  • In this paper, design method for power tower hazard diagnosis/predition system based on UsN was proposed. The proposed method used multi-hybrid sensors to measure rotation, displacement, and inclination state of power tower, and made decision/prediction of hazard of power tower. System design was made with requirement analysis of monitoring for transmission power facility and use of MEMS and optic fiber sensors. For hazard decision, analysis of correlation was made using sensor output. LN based on IEC61850,international standard for digital substation, was also proposed. For transmission facility monitoring, digital substation and power tower were considered as parts of power facility networks.

A study for PDMS Application Scheme of Digital S/S with IEC61850 Base (IEC61850 기반 디지털 변전시스팀에서의 PDMS 적용 방안에 관한 연구)

  • Lee, D.C.;Kim, H.S.;Bae, U.L.;Min, B.W.
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.78-82
    • /
    • 2006
  • The Partial Discharge Monitoring System is technology which is available to measure & analysis the partial discharge of Power equipment. This technology is in the limelight as a pre-forecast system of equipment defect but there are some problems like no protocol standard, layered network management and the limitation of physical size. This paper presents whole system structure includes engineering centers, LN(Logical Node) to apply PDMS for, base-digital substation system, ICE61850 compatible Condition Monitoring &Diagnosis (CMD), Local Unit(LU), Intelligent Electronic Device (IED) for the solution scheme of these limitations.

  • PDF

Traffic Generation Method of Sampled Values for Smart Grid (스마트 그리드를 위한 샘플 값들의 트래픽 발생 방안)

  • Hwang, Sung-Ho;Park, Kyung-Won;Park, Jeong-Do;Song, Han-Chun;Park, Jae-Do
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.225-230
    • /
    • 2015
  • This study presents a method for generating IEC 61850 Sampled Values(SV) traffic by combining the emulation function of network simulator ns-3 with the actual communication equipment. For the SV traffic generation and reception, the emulation function of the network simulator ns-3 is used, while as a communication network, the actual communication equipment, switches are used. In addition, the SV traffic frames generated are analyzed, using Wireshark, and it is confirmed that the SV traffic frames are generated accurately. The method for the SV traffic generation proposed in the present study will be very useful when various SV traffics are generated under the environment of an actual substation.

The Development of Gateway System for Power Automation based on TETRA (TETRA 기반 전력자동화 게이트웨이 시스템 개발)

  • Song, Byung-Kwen;Kim, Geon-Ung
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.41-50
    • /
    • 2010
  • TETRA is the standard of Digital Trunked Radio System suggested by the ETSI(European Telecommunications Standards Institut ). It is adopted as Electric Power IT Wireless Backbone Network in Korea. Police station and Fire Station are using TETRA network. Currently, Power Automation Protocols are DNP3.0 in Distribution Automation System, DLMS in Auto Metering Infrastructure, IEC61850 in Substation Automation. These protocols are transmissions using CDMA or WCDMA modem. If Power Automation protocol uses TETRA networks, it can be interoperable with the systems in police or fire stations. And it has outstanding ability to handle problems in a disaster situation. So, This paper propose a gateway system of Power Automation which can transmit the power automation protocol using TETRA.

Precision time sync. HW/SW platform for power system protection (전력시스템 보호를 위한 정밀 시각 동기 적용 HW/SW 플랫폼 기술)

  • Nam, Kyung-Deok;Son, Kyu-Jung;Chang, Tae-Gyu;Kang, Sang-Hee
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1036-1043
    • /
    • 2018
  • This paper presented future power system protection technologies through the HW/SW integration platform with IEC 61850 and IEEE c37.238 standards. To determine the implementation performance of the integrated platform, an example of EVM (Evaluation Module) was constructed to satisfy the standards. The platform has been identified as a future power system integrated IED(Intelligent Electronic Device) HW/SW technology that meets the level of error required by the time sync standard and the level of delay required by protecting the power system.

A Study on Substation Automation in Power System (전력계통의 변전소 자동화에 대한 연구)

  • Moon, Hyoung-Bae;Lim, Seong-Joo;Lee, Sang-Joong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.119-124
    • /
    • 2005
  • The deregulation of energy market, together with structure reorganization of vertically integrated companies in electrical utility requires efficient and reliable substation automation system. The problem of non-standards where other countries suffer through the SA points could be settled using IEC 61850 and hereby the coming SAS project can realize the system that characterize the telecommunication standards and function integration.

  • PDF

Interoperability Test of the Digital Substation using IED Conformance Testing System (IED 적합성 시험장치를 이용한 디지털 변전소 상호운용성 시험)

  • Lee, N.H.;Jang, B.T.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.11-12
    • /
    • 2007
  • In order to verify a digital substation based on IEC 61850, KEPRI in charge of POWER IT project related to SAS has constructed IED conformance testing system, which consists of HMI, IED (Intelligent Electronic Device), network equipment, V/I generator, and performed the interoperability test between two IEDs made by other vendors. The test was proceeded based on SCL and with system integrated tools

  • PDF

154kV Main TR. Bay IED Based On IEC-61850 (IEC-61850 기반의 154kV M.Tr Bay IED 적용 사례)

  • Roh, Jae-Keun;Oh, Jae-Hoon;Kim, Byoung-Choul;Ko, Choul-Jin;Yang, Hang-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.764-765
    • /
    • 2011
  • 전력시스템을 더 효율적으로 운용하고, 더 지능화하려는 노력은 2000년대 초 다양한 각도로 진행되어 왔다. 그리하여 중장기 국책과제인 전력IT 과제를 필두로 여러 지능화 기기들이 국 내외 유관업체를 통하여 지속적으로 성장을 하였고 현재에 이르러서는 과제의 틀이 아닌 비즈니스 모델 창출을 위하여 여러 시범 사업들이 구상되고 있는 중이다. 이는 전력IT 의 핵심 아이템이라 할 수 있는 IEC-61850 국제 표준 프로토콜 기반의 IED (Intelligent Electronic Devices) 개발과 어울려 변전소의 직접 현장 적용을 통한 엔지니어링 기술 개발에 역점을 두고 있는 상태이다. 변전소 자동화 (S/A: Substation Automation)의 영역이 점점 현실화 되어가고, 전 세계 적용 Site의 폭발적인 증가로 힘입어 이젠 선택이 아닌 필수가 되고 있고, 적용에서 끝이 아닌 다양한 엔지니어링 Tool 의 개발, 진단 시스템의 융합 등과 더불어 계속 발전해나가고 있다. 본 논문에서는 이러한 시대적 흐름을 바탕으로 당사에서 참여중인 한국전력 154kV S/A 시범사업 및 스마트그리드 실증사업을 통하여 현장 적용된 154kV Main Transformer 용 IED 솔루션의 적용 사례를 소개하고자 한다. S/A 시범사업의 경우, 한국전력 충주본부 풍동S/S에서 올해 초 설계되어 현재 현장 엔지니어링을 1차 마무리한 상태이며, 스마트 그리드 실증사업은 제주 성산S/S에서 진행 중이며 이도 마무리를 하는 단계에 이르러, 그동안 현장적용의 문제점을 논의하고, 이에 대한 대응책을 서로 공유하며 정리하고 있다. 참고로 본 논문에서는 IEC-61850 프로토콜 구현에 대한 것은 다루지 않으며, 다만 현장제어에 필요하고 또한 구현되어 있는 기능에 대한 전반적인 내용을 다루게 된다.

  • PDF

A Study on Auto-Drawing for Station HMI by using SCL (SCL을 이용한 Station HMI Auto-drawing기법에 관한 연구)

  • Kim, In-Woong;Kim, Tae-Wan;Choi, Myeon-Song;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.256-257
    • /
    • 2008
  • 본 논문은 IEC 61850기반의 변전소 자동화 시스템에서 Station HMI의 표현기법을 Autodrawing 하는 방안을 제안하였다. 변전소 자동화 시스템 설계자가 IEC 61850 Standard에서 제안하고 있는 변전소 시스템 구성 언어인 SCL(Substation Configuration description Language)을 가지고 변전소의 정보들을 구성 하게 된다. 이러한 SCD파일에 있는 변전소의 모든 정보를 활용하여 Station HMI에 변전소의 단선도를 자동으로 Drawing하고 각 장치들의 상태정보를 도시화 하며 통신 상태까지 표시 할 수 있는 방법을 포함하고 있다. SCL 구조를 해석하여 Data Structure에 저장하고 그 유용성에 따라 자동 생성이 가능한 기법이다.

  • PDF

The Study of Distributed Disturbance Recording System (분산형 사고파형저장 시스템에 대한 연구)

  • Park, Jong-Chan;Lee, Se-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.30-35
    • /
    • 2008
  • In this paper, the application of power Quality monitoring based on Sampled Value(SV) which is introduced in the IEC61850 International Standard for substation communication are discussed. Firstly, while Merging Unit(MU) is designed as a process level device transmitting sensor data, the practical problems such as time delay compensation and optical fiber communication are encountered. Secondly, the Sampled Value message which is proper to a power quality monitoring system is presented. Because the power quality monitoring system requests less time-critical service compared to protection and control applications, the Sampled Value service message structure is introduced to improve efficiency. Lastly, the power quality monitoring server having various power quality analysis functions is suggested to verify the performance of Merging Unit With the diverse experiments, it is proved that the process bus distributed solution is flexible and economic for the power quality monitoring.