• 제목/요약/키워드: IEC 60364

검색결과 87건 처리시간 0.029초

IEC 60364 기반의 한국형 저압전기설비 통합 실증단지 모델링 및 차단기와 케이블의 선정 방안 고찰 (Study of Selection Plan of Circuit breakers, Cables and Modeling of Korean Low Voltage Electrical Installation integration Test Site based on IEC 60364)

  • 김두웅;류규상;김한수;신대성;류기환;김철환
    • 조명전기설비학회논문지
    • /
    • 제29권9호
    • /
    • pp.59-64
    • /
    • 2015
  • IEC is an international standards which are used in many countries with Europe as the center. IEC standard is introduced in Korea according to WTO/TBT agreements, however until now there are no buildings in Korea which are designed applying IEC standard. Therefore, KEA(Korea Electric Association) is scheduled to construct Korean low voltage electrical installation integration test site which is designed applying IEC standard. In this paper, before being under construction of Korean low voltage electrical installation integration test site, power substation is modeled based on real design parameters and method to select circuit breakers and cables is presented applying IEC standard in the modeled power substation. EMTP(ElctroMagnetic Transient Program) is used for simulation program. EMTP which is power system analysis program is easy to model power system and power substation.

IEC 60364의 접지방식에 기반한 안전성 평가 시험장치의 모델링 및 구현에 관한 연구 (Modeling and Implementation of Safety Test Device for Grounding System Based on IEC 60364)

  • 김순식;한병길;이후동;페레이라 마리토;노대석
    • 한국산학기술학회논문지
    • /
    • 제22권6호
    • /
    • pp.599-609
    • /
    • 2021
  • 국내 접지방식은 2021년부터 IEC 60364에서 제시하는 접지방식을 새롭게 채택하고 있다. 이 접지방식은 인체접촉사고 발생 시, 접촉전압과 통과전류에 대한 특성이 다양하게 나타날 수 있어, 인체에 대한 안전성 평가가 구체적으로 요구되고 있다. 또한, 한국전기안전공사나 대한전기협회에서 IEC 60364의 접지방식에 대한 안전기술 교육을 부분적으로 수행하고 있지만, 안전성을 평가할 수 있는 시험장치가 미흡하여, 전기안전관리자에 대한 교육이 어려운 실정이다. 따라서, 본 논문에서는 IEC 60364의 접지방식별 안전성 평가를 수행할 수 있는 시험장치를 모델링하고, 이를 바탕으로 시험장치를 구현한다. 즉, 전력계통 상용해석 프로그램인 PSCAD/EMTDC를 이용하여, 계통 전원부, 접지방식별 시험장치부, 보조장치부로 구성된 안전성 평가 시험장치의 모델링을 제시하고, 계통전원부, TT접지방식 시험장치부, TN-S접지방식 시험장치부, 모니터링부로 구성된 안전성 평가 시험장치를 구현한다. 상기의 모델링과 시험장치를 이용하여, TT접지방식과 TN-S접지방식의 인체 안전성 특성을 분석한 결과, TT접지방식의 경우 고장점 임피던스가 0[Ω], 10[Ω], 100[Ω]에서 인체 통과전류는 각각 104[mA], 87.4[mA], 35.5[mA]가 산정되었고, TN-S접지방식의 경우 54.9[mA], 4.1[mA], 0.4[mA]가 산정됨에 따라, TN-S접지방식이 TT접지방식에 비하여 감전에 대한 보호가 우수함을 알 수 있고, 저압수용가에서 사용 중인 TT 접지방식에서 TN-S 접지방식으로 전환하면 감전에 대한 보호성능을 향상시킬 수 있음을 알 수 있었다.

IEC 60364의 구성체계

  • 한찬호
    • 전기기술인
    • /
    • 통권286호
    • /
    • pp.19-23
    • /
    • 2006
  • IEC는 International Electrotechnical Commission(국제전기표준회의)의 약자로 전기관계의 국제 표준화를 목적으로 설립된 국제단체로서 각국을 대표하는 표준화 기관으로 구성되어 있다. IEC도 국제 표준화기구(ISO)와 마찬가지로 의결권을 갖는 회원은 1국가 1단체 또는 기관으로 국한되어 있다. 전문분야별로 기술위원회(TC), 분과위원회(SC),또는 작업그룹 (WG)을 설치하고 IEC 국제표준(IEC Publication)을 작성, 발표하여 각국에서 국가표준을 정할 때에 통일된 표준을 준거하도록 권고하고 있다. IEC 국제표준은 약 3,000건에 달하고 있다. IEC의 소재지는 제네바이고 비정부 기구이며 스위스 민법 제60조에 따른 사단 법인이다.

  • PDF

전기설비기술기준에 도입되는 IEC TC64 및 TC99 규격 (International Standards of IEC TC64 & TC99 apply to Technical Regulation in Korea Electricity Business Act)

  • 김광덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.220-222
    • /
    • 2004
  • The IEC standards related to the Technical Regulation in Korea Electricity Business Act are classified into the standards/guides for electrical system and the specifications for electrical equipment/materials. IEC Standard 60364 "Electrical Installations of Buildings" and IEC Standard 61936 "Power Installations Exceeding 1 kV AC" prepared by IEC Technical Committee(TC) 64 and TC 99 respectively, are representative standards for electrical installations of buildings, substations, industrial plants, etc.

  • PDF

도시철도 지하구간 접지설비 표준화 기준 연구 (A Study on the Unification of the Grounding System of Urban Railroad)

  • 김균식;박한용;백유호;심재창
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.470-480
    • /
    • 2008
  • After 1th line was built in 1974, the history of subway in Korea has been expended to 9th line which is under construction. It is time to prepare nation wide subway grounding system urgently according to the domestic electric standard that aligns to world wide standard by WTO/TBT treat (1995). Newly added grounding system to the fundamentally different system caused many problems. PSD(platform screen door) and other newly added equipment are also need grounding system. By the electrical code(established by Korea Electric Association), low voltage equipment(including grounding system) under 1,000V AC are in the process of change into IEC 60374. IEC 60364 standard will be added to the electrical code(established by Korea Electric Association) in 2007 and amended and after 3-5 years later, it will become a complete IEC 60364. So the purpose of this study is to compare the domestic rail road grounding system and suggest the standardized grounding system for the newly built subway.

  • PDF

한국전기규정(KEC) 제2편 저압전기설비분야 제43장 배선설비 제정 현황 (An Overview of Recent Developments in Korea Electrical Code(KEC) Part 2-43 : Low-Voltage Electrical installations-Wiring systems)

  • 신기현;이강희;김준택;이금환;이효진;김한수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1633-1634
    • /
    • 2015
  • WTO/TBT 협정에 따라 2006년부터 IEC 전선의 전면적인 사용과 전기설비기술기준의 판단기준에 IEC 60364 저압전기설비분야의 도입으로 국내현장에서 국제표준을 적용할 수 있게 되었다. 그러나 국제표준(IEC)은 내용이 포괄적이며, 원론적인 부분을 다루고 있어 실제 현장 적용에 많은 어려움이 있다. 이에 따라 대한전기협회에서는 국제표준(IEC)을 기초로 하여 국제수준과 대등한 "한국전기규정 KEC"를 제정중이며, 본 연구는 KS C IEC 60364-5-52 기초로 작성한 KEC 제2편 저압전기설비분야 제43장 배선설비의 제정현황을 소개하는 것이다.

  • PDF