• Title/Summary/Keyword: IE method

Search Result 584, Processing Time 0.042 seconds

A Comparative Study on Coupling of Element-free Galerkin Method and Infinite Element by IE's Shape Function (무한요소 형상함수에 따른 무요소법과의 조합 방법 비교 연구)

  • 이상호;김명원;윤영철
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.279-287
    • /
    • 2003
  • This paper deals with a comparative study on coupling of Element-free Galerkin(EFG) method and Infinite Element(IE) by IE's shape function. In this study, mapped infinite elements(mapped IE) and decay function infinite elements(decay IE) are coupled with the EFG method. A coupling procedure of EFG-Mapped IE is much easier to be integrated than a coupled EFG-Decay IE. A coupled EFG-IE method used well-defined functions to preserve the continuity and linear consistency on the interface of the EFG region and IE region. Several benchmark problems are solved to verify the effectiveness and accuracy of the coupling algorithms by IE's shape function. The numerical results show that the developed algorithms work well for the elastic problems with infinite boundaries.

  • PDF

A Study on Electromagnetic Scattering Analysis of Penetrable Objects Using Block Matrix Preconditioner(BMP) and IE-FFT (Block Matrix Preconditioner와 IE-FFT를 이용한 침투 가능한 구조물의 전자기 산란해석에 관한 연구)

  • Kang, Ju-Hwan
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.614-621
    • /
    • 2019
  • In this paper, we presents the integral equation-fast Fourier transform(IE-FFT) and block matrix preconditioner (BMP) to solve electromagnetic scattering problems of penetrable structures composed of dielectric or magnetic materials. IE-FFT can significantly improve the amount of calculation to solve the matrix equation constructed from the moment method(MoM). Moreover, the iterative method in conjunction with BMP can be significantly reduce the number of iterations required to solve the matrix equations which are constructed from electrically large structures. Numerical results show that IE-FFT and block matrix preconditioner can solve electromagnetic scattering problems for penetrable objects quickly and accurately.

A Model Test of IE and IR Method to Detect the Cavity Underneath the Concrete Structure (콘크리트 구조물 하부의 공동 탐지를 위한 충격반향(IE) 및 충격응답(IR) 기법의 모형 실험)

  • Noh, Myung-Gun;Oh, Seok-Hoon
    • Journal of the Korean earth science society
    • /
    • v.32 no.1
    • /
    • pp.1-11
    • /
    • 2011
  • The impact echo and impulse response methods were applied to the safety inspection of concrete structure, which has the rear cavity. The concrete structure model used in this study was divided into four sections, pure concrete, concrete+cavity, reinforced concrete with iron bar, and reinforced concrete+cavity, respectively. Previous study performed by authors have showed a possibility of success to use these method for detection of the rear cavity of concrete structure. Therefore, we tried to get more enhanced result with IE and IR methods through this study. Especially, IE and IR methods are relatively accurate to map the point of measurement, which makes it possible to interpret the depth of the concrete bed and effect by rear cavity with confidence. Followings were revealed from the results; the IE method shows some small peak zones probably indicating the rear cavity in the frequency lower than the resonance frequency and the changes of mobility and dynamic stiffness in the IR method indicate the weak zones. The proposed methods can be used to delineate the weak zones of the concrete structure.

IE-SASW Method for Nondestructive Testing of Geotechnical Concrete Structure : II. Experimental Studies (콘크리트 지반구조물의 비파괴검사를 위한 충격반향-표면파 병행기법 : II. 실험적 연구)

  • 김동수;서원석;이광명
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.271-283
    • /
    • 2002
  • P-wave velocity of concrete is a crucial parameter in determining the thickness of concrete lining, the location of cracks or other defects in Impact-Echo(IE) method. This study introduces an IE-SASW method that may determine the P-wave velocity on a surface of each testing area using the Spectral Analysis of Surface Wave (SASW) method. In numerical studies(Part I), it was verified that P-wave velocities could be obtained from SASW. In this paper(Part II), experimental studies were made in slab type concrete model specimens in which voids and waterproof sheet were included at the known locations. Accordingly, the feasibility of the proposed method was evaluated. The IE-SASW method was also performed in the precast model tunnel on ground and open-cut tunnel in ground. SASW tests were performed to determine the P-wave velocity of the concrete and then IE tests were carried at regularly spaced points along the testing lines to determine the thickness of structures. The nondestructive testing method which combined SASW and IE tests showed the great potential in the field applications.

An IE-FFT Algorithm to Analyze PEC Objects for MFIE Formulation

  • Seo, Seung Mo
    • Journal of electromagnetic engineering and science
    • /
    • v.19 no.1
    • /
    • pp.6-12
    • /
    • 2019
  • An IE-FFT algorithm is implemented and applied to the electromagnetic (EM) solution of perfect electric conducting (PEC) scattering problems. The solution of the method of moments (MoM), based on the magnetic field integral equation (MFIE), is obtained for PEC objects with closed surfaces. The IE-FFT algorithm uses a uniform Cartesian grid to apply a global fast Fourier transform (FFT), which leads to significantly reduce memory requirement and speed up CPU with an iterative solver. The IE-FFT algorithm utilizes two discretizations, one for the unknown induced surface current on the planar triangular patches of 3D arbitrary geometries and the other on a uniform Cartesian grid for interpolating the free-space Green's function. The uniform interpolation of the Green's functions allows for a global FFT for far-field interaction terms, and the near-field interaction terms should be adequately corrected. A 3D block-Toeplitz structure for the Lagrangian interpolation of the Green's function is proposed. The MFIE formulation with the IE-FFT algorithm, without the help of a preconditioner, is converged in certain iterations with a generalized minimal residual (GMRES) method. The complexity of the IE-FFT is found to be approximately $O(N^{1.5})$and $O(N^{1.5}logN)$ for memory requirements and CPU time, respectively.

IE-SASW Method for Nondestructive Testing of Geotechnical Concrete Structure : I. Numerical Studies (콘크리트 지반구조물의 비파괴검사를 위한 충격반향-표면파병행기법 : I. 수치해석적 연구)

  • 김동수;서원석;이광명
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.257-270
    • /
    • 2002
  • The Impact-Echo(IE) method has been used to evaluate the integrity of concrete structures. In this method, the P-wave velocity of concrete is a crucial parameter in determining the thickness of concrete lining, the location of cracks or other defects. In many field applications of the IE method, the P-wave velocity is obtained by testing the core or the portion of a structure where the exact thickness is known. Occasionally, however, the core can not be obtained in specific structures and the P-wave velocity determined from core testing may not be a representative value of the structure. This study introduces an IE-SASW method that may determine the P-wave velocity on a surface of each testing area using the Spectral Analysis of Surface Wave (SASW) method. Results obtained from numerical studies are presented in this paper (Part I), and results obtained from experimental studies are presented in the companion paper (Part II). In this paper, numerical analyses using ABAQUS were carried out to investigate the effectiveness and the limitations of the IE-SASW method.

Technical note: Estimation of Korean industry-average initiating event frequencies for use in probabilistic safety assessment

  • Kim, Dong-San;Park, Jin Hee;Lim, Ho-Gon
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.211-221
    • /
    • 2020
  • One fundamental element of probabilistic safety assessment (PSA) is the initiating event (IE) analysis. Since IE frequencies can change over time, time-trend analysis is required to obtain optimized IE frequencies. Accordingly, such time-trend analyses have been employed to estimate industry-average IE frequencies for use in the PSAs of U.S. nuclear power plants (NPPs); existing PSAs of Korean NPPs, however, neglect such analysis in the estimation of IE frequencies. This article therefore provides the method for and results of estimating Korean industry-average IE frequencies using time-trend analysis. It also examines the effects of the IE frequencies obtained from this study on risk insights by applying them to recently updated internal events Level 1 PSA models (at-power and shutdown) for an OPR-1000 plant. As a result, at-power core damage frequency decreased while shutdown core damage frequency increased, with the related contributions from each IE category changing accordingly. These results imply that the incorporation of time-trend analysis leads to different IE frequencies and resulting risk insights. The IE frequency distributions presented in this study can be used in future PSA updates for Korean NPPs, and should be further updated themselves by adding more recent data.

Combination of Element-Free Galerkin Method and Infinite Elements (무요소법과 무한요소의 결합에 관한 연구)

  • 이상호;김태연
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.76-83
    • /
    • 2001
  • In this study, a new method coupling of Element-Free Galerkin(EFG) method and Infinite Elements(IE) method is presented for extending application of the EFG method to engineering problems in unbounded domain. EFG method and IE method are briefly reviewed, and then the coupling procedure of the two methods is proposed. Numerical Algorithm by way of EFG-lE coupling technique is also developed. Numerical results illustrate the performance of the proposed technique. The accuracy of numerical solutions by the developed algorithm is guaranteed in comparing those of the other methods.

  • PDF

Case Study on the Impact-Echo Method for Tunnel Safety Diagnosis (터널 안전진단을 위한 충격반향법 사례 연구)

  • Shin, Sung-Ryul;Jo, Cheol-Hyun
    • Tunnel and Underground Space
    • /
    • v.19 no.1
    • /
    • pp.19-30
    • /
    • 2009
  • For the purpose of determining the thickness of concrete lining and detect of the cavity where may be located behind tunnel lining, IE (Impact-Echo) method it effectively useful in the tunnel safety diagnosis and the quality control during the construction. As a part of case study, we applied IE method to various tunnel structure types such as road tunnel and subway tunnel constructed by NATM (New Austrian Tunnelling Method) and ASSM (American Steel Support Method). As tunnel specifications estimated from this method were compared with coring data, design drawing and other survey results, it was very good agreement with each other. In conclusion, we verified that IE method shows an accurate and reliable result. The conventional interpretation of IE method in frequency domain gives only vertical information at a certain point. However, the interpretation using time-frequency analysis and depth section imaging technique from two dimensional profiling surveys can show more reliable information about structure inside.