• Title/Summary/Keyword: ICP analysis

Search Result 823, Processing Time 0.022 seconds

Chemical Analysis of Fly Ashes from Municipal Solid Waste Incinerators (생활폐기물 처리시설 배출 비산재의 조성분석)

  • Jang, Seong-Ki;Choi, Duk-Il;Lim, Chang-Ho;Lee, Jin-Sook
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.215-221
    • /
    • 2000
  • Analysis of fly ashes from the MSW incinerators was carried out using XRF, ICP-MS and ICP-AES. It was found that the major elements of fly ash were Ca, K, Na, Si, Al, S, Cl and O by the XRF analysis. The XRD spectra showed that the fly ashes were mainly consisted with the chlorides, hydroxides, carbonates and also oxides of former elements. For the determination of minor elements such as Zn, Pb, Cu, Cr, and Cd, we used ICP-AES and ICP-MS after microwave digestion and the results were compared with the result of XRF.

  • PDF

A study on the determination of lead in whole blood by ICP/MS (ICP/MS에 의한 전혈 중 납의 분석방법 연구)

  • Park, Kyung Su;Kim, Sun Tae
    • Analytical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.240-245
    • /
    • 1997
  • An accurate analysis method for the determination of lead in whole blood by ICP/MS was developed. Whole blood samples were decomposed in microwave digestion system without any contamination and loss of lead. The 96 samples were analyzed by ICP/MS using mass$^{208}$ isotope of lead. Lead concentrations of human whole blood were ranged of $2.50{\sim}22.8{\mu}g/dL$. The accuracy of this analysis method was verified by analyzing of NIST SRM 955a series(lead in blood).

  • PDF

A Study on the Analytical Characterizations of the Low Flow-Low Power ICP-AES (Low flow-low power 유도결합 플라즈마 원자방출 분광법에서의 분석적 특성에 관한 연구)

  • Yang, Hae Soon;Kim, Young Man;Kim, Sun Tae;Choi, Beom Suk
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.253-260
    • /
    • 1994
  • Analytical characteristics of low power-low flow inductively coupled plasma-atomic emission spectometry(ICP-AES) has been studied. Although the net intensity of the low power ICP is lower than the moderate power ICP, the signal to background ratio becomes higher since the background intensity decreases with decreasing the RF power. The detection limit of the low power ICP is comparable with that of the moderate power ICP. The dynamic range of the calibration curve of the low power ICP is $10^4{\sim}10^5$. The ionization interferences by alkali metals increase with increasing the carrier gas flow rate, but the effects are not varied significantly with the RF power.

  • PDF

The chemical speciation and analysis of trace elements in sediment with neutron activation analytical method(NAA) and atomic mass spectrometry (중성자 방사화분석법과 원자질량분석법을 이용한 침전물 시료속에 존재하는 미량원소들의 화학종 분류 및 분석)

  • Nam, Sang-Ho;Kim, Jae-Jin;Chung, Yong-Sam;Kim, Sun-Ha
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.358-367
    • /
    • 2003
  • In this research, first of all, the analytical methods for the determination of major elements in sediment have been developed with ICP-MS (Inductively Coupled Plasma Mass Spectrometry). The analytical results of major elements (Al, Ca, K, Fe, Mg) with Cool ICP-MS were much better than those with normal ICP-MS. The analytical results were compared with those of NAA (Neutron Activation Analysis). NAA were a little superior to ICP-MS for the determination of major elements in sediment as a non-destructive trace analytical method. The analytical methods for the determination of minor elements (Cr, Ce, U, Co, Pb, As, Se) have been also developed with ICP-MS. The analytical results by standard calibration curve with ICP-MS were not accurate due to the matrix interferences. Thus, the internal standard method was applied, then the analytical results for minor elements with ICP-MS were greatly improved. The analytical results obtained by ICP-MS were compared with those obtained by NAA. It showed that the two analytical methods have great capabilities for the determination of minor elements in sediments. Accordingly, the NAA will play an important role in analysis of environment sample with complex matrix. ICP-MS also will play an important role because it has a great capability for the determination of Pb that could not be determined by NAA.

Analysis of Trace Elements in Mud Flat with Neutron Activation Analysis (NAA) and Atomic Spectroscopy (중성자 방사화 분석법과 원자 분광법을 이용한 갯벌 시료 중 미량원소 분석법에 관한 연구)

  • Nam, Sang-Ho;Kim, Min-Jae;Chung, Yong-Sam;Kim, Sun-Ha
    • Analytical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.521-528
    • /
    • 2002
  • Neutron Activation Analysis (NAA) and Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) have been applied for the determination of inorganic elements in mud flat of south seaside in Korea. The analytical results of Al, Ca, Fe, Mg, K and Na by NAA were compared with those by ICP-AES. The results show that NAA is superior to ICP-AES for the determination of minor elements in sediment. Accordingly, NAA will play an important role in the analysis of environment samples such as mud flat and sediment having complex matrix.

Determination of Boron in Steels by Precipitation Method and ICP-AES (침전법과 ICP-AES법에 의한 철강 시료 중 Boron의 분석)

  • Lim, Heon-Sung;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.180-183
    • /
    • 2002
  • The new useful method for the direct determination of trace boron in iron matrix was studied by applying the precipitation of $Fe(OH)_3$ and ICP-AES. Optimum pH range was 11 ~ 12.5. Linear concentration range of boron was $0.01{\sim}1.0{\mu}g/m{\ell}$ in $5000 {\mu}g/m{\ell}$ solution as iron.

Applicability of CCT-ICP-MS for the Determination of Trace Elements in Airborne Particulate Matters (CCT-ICP-MS의 대기분진내 미량원소분석에 대한 적용성)

  • 임종명;이진홍;서만철
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.3
    • /
    • pp.397-409
    • /
    • 2004
  • There has been few studies of either domestic or international to apply CCT-ICP-MS for the precise analysis of As and Cr components associated with airborne particulate matter. To date, the use of CCT-ICP-MS is strongly recommended for the accurate analysis of the toxic trace metals; this is because CCT-ICP-MS technique prevents polyatomic spectral interferences involved in the determination of As and/or Cr components. Taking advantage of CCT-ICP-MS technique, the measurements of about 20 metals were undertaken in this study. The standard reference material (NIST SRM 2783) was used for analytical quality control. To improve analytical accuracy and of acid efficiency, we selected nitric acid based on a test of three kinds of acid for microwave digestion method 1 ) nitric acid. 2) nitric acid and hydrogen peroxide. and 3) nitric acid and perchloric acid. When this method was employed, relative errors to SRM values of Al, As, Cr Fe, Mg, Mn, Pb, Sb, V, and Zn fell below 20%, while those or Ca, Si, and Ti were higher than 20%. The overall results of our study show that the concentrations of As and V determined by CCT-ICP-MS were satisfied with the certificated values within a relative error of 20e1c, whereas those determined by ICP-MS were 10 times higher than the certificated values.

Construction of a Baculovirus Hyphantria cunea NPV Insecticide Containing the Insecticidal Protein Gene of Bacillus thuringiensis subsp. kurstaki HD1

  • Lee, Hyung-Hoan;Moon, Eui-Sik;Lee, Sung-Tae;Hwang, Sung-Hei;Cha, Soung-Chul;Yoo, Kwan-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • v.8 no.6
    • /
    • pp.685-691
    • /
    • 1998
  • Baculovirus Hyphantrin. cunea nuclear polyhedrosis virus (HcNPV) insecticide containing the insecticidal protein (ICP) gene from Bacillus thuringiensis subsp. kurstaki HD1 was constructed using a lacZ-HcNPV system. The ICP ($\delta$-endotoxin) gene was placed under the control of the polyhedrin gene promoter of the HcNPV. A polyhedrin-negative virus was derived and named ICP-HcNPV insecticide. Then, the insertion of the ICP gene in the ICP-HcNPV genome was confirmed by Southern hybridization analysis. Polyacrylamide gel electrophoresis (PAGE) analysis of the Spodoptera frugiperda cell extracts infected with the ICP-HcNPV showed that the ICP was expressed in the insect cells as 130 kDa at 5 days post-infection. The ICP produced in the cells was present in aggregates. When extracts from the cells infected with the ICP-HcNPV were fed to 20 Bombyx mori larvae, the following mortality rate was seen; 8 larvae at 1 h, 10 larvae at 3 h, and 20 larvae at 12 h. These data indicate that the B. thuringiensis ICP gene was expressed by the baculovirus insecticide in insect cells and there was a high insecticidal activity. The biological activities of the recombinant virus ICP-HcNPV were assessed in conventional bioassay tests by feeding virus particles and ICP to the insect larvae. The initial baculovirus insecticide ICP-HcNPV was developed in our laboratory and the significance of the genetically engineered virus insecticides is discussed.

  • PDF

Relationship between Increased Intracranial Pressure and Mastoid Effusion

  • Jung, Hoonkyo;Jang, Kyoung Min;Ko, Myeong Jin;Choi, Hyun Ho;Nam, Taek Kyun;Kwon, Jeong-Taik;Park, Yong-sook
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.5
    • /
    • pp.640-648
    • /
    • 2020
  • Objective : This study aimed to assess the relationship between increased intracranial pressure (ICP) and mastoid effusions (ME). Methods : Between January 2015 and October 2018, patients who underwent intracranial surgery and had ICP monitoring catheters placed were enrolled. ICP was recorded hourly for at least 3 days. ME was determined by the emergence of opacification in mastoid air cells on follow-up brain imaging. C-reactive protein (CRP) levels, presence of endotracheal tube (ETT) and nasogastric tube (NGT), duration of intensive care unit (ICU) stay, duration of mechanical ventilator application, diagnosis, surgical modalities, and presence of sinusitis were recorded. Each factor's effect on the occurrence of ME was analyzed by binary logistic regression analyses. To analyze the independent effects of ICP as a predictor of ME a multivariable logistic regression analysis was performed. Results : Total of 61 (53%) out of 115 patients had ME. Among the patients who had unilateral brain lesions, 94% of subject (43/50) revealed the ipsilateral development of ME. ME developed at a mean of 11.1±6.2 days. The variables including mean ICP, peak ICP, age, trauma, CRP, ICU stays, application of mechanical ventilators and presence of ETT and NGT showed statistically significant difference between ME groups and non-ME groups in univariate analysis. Sex and the occurrence of sinusitis did not differ between two groups. Adding the ICP variables significantly improved the prediction of ME in multivariable logistic regression analysis. Conclusion : While multiple factors affect ME, this study demonstrates that ICP and ME are probably related. Further studies are needed to determine the mechanistic relationship between ICP and middle ear pressure.