• Title/Summary/Keyword: ICP Monitoring

Search Result 102, Processing Time 0.031 seconds

Detection of Heavy Metal Ions in Aqueous Solution Using Direct Dye Chemosensors

  • Heo, Eun-Yeong;Ko, Young-Il;Bae, Jin-Seok
    • Textile Coloration and Finishing
    • /
    • v.21 no.5
    • /
    • pp.51-57
    • /
    • 2009
  • Since heavy metal pollution is a significant global environmental problem and very dangerous to human health, the improved methods for detecting heavy metals are required recently. Colorimetric chemosensors are now considered as one of the most effective analytical method used in the environment monitoring. New direct dyes having the function of colorimetric chemosensors were synthesized. When metal ions such as $Al^{3+}$, $Ca^{2+}$, $Cd^{2+}$, $Cr^{3+}$, $Cu^{2+}$, $Fe^{2+}$, $Fe^{3+}$, $Hg^{2+}$, $Li^+$, $Mg^{2+}$, $Na^+$, $Ni^{2+}$, $Pb^{2+}$ and $Zn^{2+}$ were added each solution of new direct dyes, the color of solution was changed and can be easily detected with naked eyes without expensive experimental equipment such as atomic absorption spectrometer (AAS) or inductively coupled plasma?mass spectrometer (ICP-MS). The new benzidine analogues were diazotized and reacted with couplers such as H-acid, J-acid, Chromotropic acid, Nevill-winther acid and gamma acid to synthesize new direct dyes. The structures of the new direct dyes were confirmed by high resolution mass spectrometer (FAB ionization) and evaluated with UV-Vis spectroscopy. The UV-VIS spectroscopy was measured for the dye solutions by adding various concentrations of metal ions. It was observed that the absorbance in UV-Vis spectra was changed as the heavy metal ions were added.

Clinical Significance of Bifrontotemporal Decompressive Craniectomy in the Treatment of Severe Refractory Posttraumatic Brain Swelling (중증 외상성 뇌부종 환자에서 양측 전두-측두부 감압적 개두술의 의의)

  • Shin, Hyung Shik;Kim, Jin Yong;Kim, Tae Hong;Hwang, Yong Soon;Kim, Sang Jin;Park, Sang Keun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.9
    • /
    • pp.1179-1183
    • /
    • 2000
  • Objective : The treatment of malignant posttraumatic brain swelling remains a frustrating endeavor for neurosurgeon. Mortality and morbidity rates remain high depite advances in medical treatment of increased intracranial pressure. If conventional therapy fails in patients suffering from intracranial hypertension, there is only small number of second-tier option left including decompressive craniectomy. The role of decompressive craniectomy in posttraumatic brain swelling remains controversial. We assessed the efficacy and indications of decompressive craniectomy. Methods : The authors performed decompressive bifrontotemporal craniectomy in 22 patients with malignant posttraumatic brain swelling. Epidural pressure monotoring was performed in all patients. The clnical data and surgical outcomes were reviewed retrospectively. Result : The favorable outcome(GOS score 4-5) was 59%(13 of 22 patients), whereas the mortality rate was 32% (7 of 22 patients). Two patients(9%) remained in severely disabled state. Increased rate of favorable outcome was seen in the patients who had 8 or more of GCS score at admission and exhibited B wave in ICP monitoring and who showed steady state or slow deterioration in clinical course. Conclusion : If conservative therapy fails, decompressive bifrontotemporal craniectomy should be considered in the management of malignant posttraumatic brain swelling before irreversible ischemic brain damage occur.

  • PDF

The Effect of Barbiturate Coma Therapy for the Patients with Severe Intracranial Hypertension : A 10-Year Experience

  • Kim, Young-Il;Park, Seung-Won;Nam, Taek-Kyun;Park, Yong-Sook;Min, Byung-Kook;Hwang, Sung-Nam
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.3
    • /
    • pp.141-145
    • /
    • 2008
  • Objective : Barbiturate coma therapy (BCT) has been known to be an useful method to control increased intracranial pressure (IICP) refractory to medical and surgical treatments. We have used BCT for patients with severe IICP during the past 10 years, and analyzed our results with review of literatures. Methods : We analyzed 92 semicomatose or comatose patients with Glasgow coma scale (GCS) of 7 or less with severe IICP due to cerebral edema secondary to parenchymal damages irrespective of their causes. Forty patients who had received BCT with ICP monitoring from January 1997 to December 2006 were included in BCT group, and fifty-two patients who had been managed without BCT from January 1991 to December 1995 were divided into control group. We compared outcomes with Glasgow outcome scale (GOS) and survival rate between the two groups. Results : Good outcome (GOS=4 and 5) rates at 3-month after insult were 27.5% and 5.8% in BCT and control group, respectively (p<0.01). One-year survival rates were 35.9% and 12.5% in BCT and control group, respectively (p<0.01). In BCT group, the mean age of good outcome patients ($37.1{\pm}14.9$) was significantly lower than that of poor outcome patients ($48.1{\pm}13.5$) (p<0.05). Conclusion : With our 10-year experience, we suggest that BCT is an effective treatment method for severe IICP patients for better survival and GOS, especially for younger patients.

Real-Time Spacer Etch-End Point Detection (SE-EPD) for Self-aligned Double Patterning (SADP) Process

  • Han, Ah-Reum;Lee, Ho-Jae;Lee, Jun-Yong;Hong, Sang-Jeen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.436-437
    • /
    • 2012
  • Double patterning technology (DPT) has been suggested as a promising candidates of the next generation lithography technology in FLASH and DRAM manufacturing in sub-40nm technology node. DPT enables to overcome the physical limitation of optical lithography, and it is expected to be continued as long as e-beam lithography takes place in manufacturing. Several different processes for DPT are currently available in practice, and they are litho-litho-etch (LLE), litho-etch-litho-etch (LELE), litho-freeze-litho-etch (LFLE), and self-aligned double patterning (SADP) [1]. The self-aligned approach is regarded as more suitable for mass production, but it requires precise control of sidewall space etch profile for the exact definition of hard mask layer. In this paper, we propose etch end point detection (EPD) in spacer etching to precisely control sidewall profile in SADP. Conventional etch EPD notify the end point after or on-set of a layer being etched is removed, but the EPD in spacer etch should land-off exactly after surface removal while the spacer is still remained. Precise control of real-time in-situ EPD may help to control the size of spacer to realize desired pattern geometry. To demonstrate the capability of spacer-etch EPD, we fabricated metal line structure on silicon dioxide layer and spacer deposition layer with silicon nitride. While blanket etch of the spacer layer takes place in inductively coupled plasma-reactive ion etching (ICP-RIE), in-situ monitoring of plasma chemistry is performed using optical emission spectroscopy (OES), and the acquired data is stored in a local computer. Through offline analysis of the acquired OES data with respect to etch gas and by-product chemistry, a representative EPD time traces signal is derived. We found that the SE-EPD is useful for precise control of spacer etching in DPT, and we are continuously developing real-time SE-EPD methodology employing cumulative sum (CUSUM) control chart [2].

  • PDF

The monitoring of heavy metals (lead and cadmium) in honeys consumed in Incheon region

  • Lee, Sung-Mo;Kim, Jung-Im;Park, Eun-Jeong;Hong, Jee-Young;Lee, Jung-Goo;Hwang, Hyun-Soon;Kim, Yong-Hee
    • Korean Journal of Veterinary Service
    • /
    • v.29 no.4
    • /
    • pp.451-457
    • /
    • 2006
  • This study was conducted to investigate the contents of lead (Pb) and cadmium(Cd) in honeys (n=60) from April to May in 2004 and to provide the scientific basis for heavy metal regulations of Korea Food Code. The samples were digested with acids, then analyzed for the contents of Pb and Cd by an inductively coupled plasma spectrometer (ICP). The contents of Pb and Cd [minimum-maximum (mean)] were 0.189-1.82 mg/kg (0.568) and not detected (ND)-0.016 mg/kg (0.0008) in domestic acacia honeys (n=20), ND-1.702 mg/kg (0.329) and ND-0.243 mg/kg (0.013) in domestic wild flower honeys (n= 18), ND-0.322 mg/kg (0.073), ND-0.027 mg/kg (0.002) in imported honeys (n=13), ND-3.754 mg/kg (0.671) and ND-0.658 mg/kg (0.073) in foreign honeys (n=9) brought by Korean travellers, respectively. According to the results, foreign honeys brought by Korean travellers were detected with the highest level of Pb and Cd. Therefore, we recommend that heavy metals of domestic and foreign honeys should be continuously monitored. It is also thought that these results could be the important references to establish the standard of Pb and Cd in honey.

Virtual Metrology for predicting $SiO_2$ Etch Rate Using Optical Emission Spectroscopy Data

  • Kim, Boom-Soo;Kang, Tae-Yoon;Chun, Sang-Hyun;Son, Seung-Nam;Hong, Sang-Jeen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.464-464
    • /
    • 2010
  • A few years ago, for maintaining high stability and production yield of production equipment in a semiconductor fab, on-line monitoring of wafers is required, so that semiconductor manufacturers are investigating a software based process controlling scheme known as virtual metrology (VM). As semiconductor technology develops, the cost of fabrication tool/facility has reached its budget limit, and reducing metrology cost can obviously help to keep semiconductor manufacturing cost. By virtue of prediction, VM enables wafer-level control (or even down to site level), reduces within-lot variability, and increases process capability, $C_{pk}$. In this research, we have practiced VM on $SiO_2$ etch rate with optical emission spectroscopy(OES) data acquired in-situ while the process parameters are simultaneously correlated. To build process model of $SiO_2$ via, we first performed a series of etch runs according to the statistically designed experiment, called design of experiments (DOE). OES data are automatically logged with etch rate, and some OES spectra that correlated with $SiO_2$ etch rate is selected. Once the feature of OES data is selected, the preprocessed OES spectra is then used for in-situ sensor based VM modeling. ICP-RIE using 葰.56MHz, manufactured by Plasmart, Ltd. is employed in this experiment, and single fiber-optic attached for in-situ OES data acquisition. Before applying statistical feature selection, empirical feature selection of OES data is initially performed in order not to fall in a statistical misleading, which causes from random noise or large variation of insignificantly correlated responses with process itself. The accuracy of the proposed VM is still need to be developed in order to successfully replace the existing metrology, but it is no doubt that VM can support engineering decision of "go or not go" in the consecutive processing step.

  • PDF

The High Concentration Oxygen Therapy in Severe Head Injury Patients (중증 뇌손상 환자에서 고농도 산소치료법)

  • Park, Sung-Ho;Park, Han-Jun;Youn, Seung-Hwan;Cho, Joon;Moon, Chang-Taek;Chang, Sang-Jeun
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.37-43
    • /
    • 2001
  • Object : The rapid and early oxygen delivery to brain tissue was a common therapeutic method in the treatment of severe head injury patients. The purpose of this study was to investigate the effect of increased fraction of inspired oxygen in early stage of severe head injury. Methods : The parameters of research were CSF(cerebral spinal fluid) oxygen pressure($PcsfO_2$), lactate, pH, temperature, and CSF carbon dioxide pressure($PcsfCO_2$). We selected 28 patients with head trauma whose the Glasgow Coma Scale(GCS) score was less than 8 point at admission. All patients were mechanically ventilated and monitored with the commercial ICP monitoring device. Each of parameters was compared as increased fraction of inspired oxygen. In experimental cohort of 14 patients, the mean $PcsfO_2$ level was increased to $314.93{\pm}259.15mmHg$ by raising the $FiO_2$ from 40% to 100% for nine hours(p<0.05). And the mean CSF lactate level was decreased to $2.96{\pm}1.98mmol/L$ on 100% $FiO_2$ as compared with $5.98{\pm}3.25mmol/L$ on 40% $FiO_2$ in control group(p<0.05). The only above two parameters were showed statistically meaningful outcome. Conclusions : Although this study was performed in small cohort and short period, these results supports that increased inspired oxygen therapy in severe head injuried patients was recommended as a modality of treatment in future through the continuous survey.

  • PDF

Development of Certified Reference Materials for Analysis of Heavy Metals in Paints to Cope with Environmental Regulations (환경규제 대응을 위한 페인트 중의 중금속 분석용 인증 표준물질 개발)

  • Yu, Byung Kyu;Sun, Yle Shik
    • Journal of Environmental Analysis, Health and Toxicology
    • /
    • v.21 no.4
    • /
    • pp.209-219
    • /
    • 2018
  • In the areas of RoHS, WEEE, ELV and REACH, reinforcement of environmental regulations against harmful substances is a global trend not only in EC but also in all over the world. In the fields of Korea's major export products such as material parts, electrical and electronic products and automobile parts, we are responding to these regulations consistently. To develop reference material for analyzing lead and cadmium in paints, the candidate materials were produced through the screening process which separated shapes and sizes. To secure the traceability of the candidate materials produced, the characteristics and uncertainties are estimated by ICP-AES analysis using the primary reference material. The short-term and long-term stabilities also are evaluated in parallel. In order to calculate the final certification value of the candidate material, the verification were carried out by the performance evaluation through the comparison among the KOLAS (Korea Laboratory Accreditation Scheme) laboratories, and the CRM was produced in accordance with ISO Guide 35. The certified values and uncertainties of Pb and Cd of the final paint standard, determined according to the joint analysis among laboratories, are Pb [($191.4{\pm}3.1$) mg/kg, ($944.1{\pm}5.6$) mg/kg] and Cd [($45.0{\pm}2.6$) mg/kg, ($225.5{\pm}3.5$) mg/kg]. These standard materials were developed to enhance the reliability of measurement analysis, including the validity and traceability of measurement results. Also it is expected that the CRM will be used as QCM (quality control material) for the product design and the process monitoring, so that regulation and management of hazardous heavy metals can be systematically implemented.

Monitoring of Heavy Metals in Fruits in Korea (유통 중인 과일류의 중금속 모니터링)

  • Lee, Jin-Ha;Seo, Ji-Woo;An, Eun-Sook;Kuk, Ju-Hee;Park, Ji-Won;Bae, Min-Seok;Park, Sang-Wook;Yoo, Myung-Sang
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.2
    • /
    • pp.230-234
    • /
    • 2011
  • According to the Codex committee, the maximum allowable level for lead in fruits is 0.1 mg/kg. This survey was conducted as a surveillance program following the establishment of safety guideline for fruits in Korea. Concentrations of lead (Pb), cadmium (Cd), arsenic (As) and mercury (Hg) were measured in 927 samples using a ICP-MS and a mercury analyzer. The recoveries of microwave digestion method were 86.0-110.4% for Pb, 81.0-104.0% for Cd and 82.0-104.7% for As by standard addition method. The recovery of direct mercury analyzer was 106.5% for Hg. The average levels of Pb in ${\mu}g/kg$ were $10.0{\pm}12.8$ for apple, $8.8{\pm}10.9$ for pear, $4.1{\pm}4.4$ for persimmons, $14.9{\pm}12.3$ for mandarin, $7.1{\pm}6.5$ for orange, $3.1{\pm}3.3$ for banana, $8.8{\pm}8.9$ for kiwi, and $9.3{\pm}9.7$ for mango. The average levels of Cd in ${\mu}g/kg$ were $0.4{\pm}0.3$ for apple, $2.0{\pm}1.6$ for pear, $0.3{\pm}0.3$ for persimmon, $0.1{\pm}0.1$ for mandarin, $0.1{\pm}0.1$ for orange, $1.3{\pm}1.8$ for banana, $0.5{\pm}0.5$ for kiwi, and $0.7{\pm}0.6$ for mango. The average levels of As in ${\mu}g/kg$ were $2.0{\pm}2.1$ for apple, $1.2{\pm}1.3$ for pear, $1.5{\pm}1.2$ for persimmon, $0.8{\pm}0.3$ for mandarin, $1.5{\pm}0.5$ for orange, $1.8{\pm}1.2$ for banana, $1.6{\pm}1.5$ for kiwi, and $1.2{\pm}1.5$ for mango. The average levels of Hg in ${\mu}g/kg$ were $0.5{\pm}0.4$ for apple, $0.3{\pm}0.2$ for pear, $0.2{\pm}0.1$ for persimmon, $0.2{\pm}0.1$ for mandarin, $0.2{\pm}0.1$ for orange, $0.2{\pm}0.0$ for banana, $0.2{\pm}0.2$ for kiwi, and $0.6{\pm}0.2$ for mango. Based on the Korean public nutrition report 2005, these levels (or amounts) are calculated only at 0.17% for Pb, 0.013% for Cd and 0.006% for Hg of those presented in provisional tolerable weekly Intake (PTWI) which has been established by FAO/WHO. Therefore, the levels presented here are presumed to be adequately safe.

Monitoring of Heavy Metals in Fishes in Korea -As, Cd, Cu. Pb, Mn, Zn, Total Hg - (유통 중인 어류의 중금속 모니터링 - 비소, 카드뮴, 구리, 납, 망간, 아연, 총수은 -)

  • Kim, Hee-Yun;Kim, Seo-Young;Lee, Jin-Ha;Jang, Young-Mi;Lee, Myoung-Sook;Park, Jong-Seok;Lee, Kwang-Ho;Kim, Jin-Chul
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.353-359
    • /
    • 2007
  • This survey was carried out to estimate the heavy metal contents of fishes (531 ocean fishes and 80 freshwater fishes) sold in and around Korea from April to October in 2006 . The contents of arsenic (As), cadmium (Cd), copper (Cu), lead (Pb), manganese (Mn), zinc (Zn) and mercury (Hg) were estimated by inductively coupled plasma-mass spectrometry (ICP-MS) and a mercury analyzer. The concentrations [mean (minimum-maximum) mg/kg] of heavy metals in the ocean fishes were as follows: As=2.523 (0.140-65.543), Cd=0.017 (0.000-0.108), Cu=0.569 (0.040-5.634), Pb=0.023 (0.000-0.323), Hg=0.068 (0.002-0.754), Mn=0.395 (0.016-4.651) and Zn=6.086 (0.529-34.729). The concentrations of heavy metals in the freshwater fishes were: As=0.370 (0.024-2.231), Cd=0.01l (ND-0.086), Cu=0.628 (0.003-1.962), Pb=0.026 (ND-0.423), Hg=0.058 (0.006-0.349), Mn=1.150 (0.069-7.230) and Zn=9.980 (3.463-82.737). The weekly intakes of Cd, Hg and Pb from fish were 0.9, 1.6 and 0.9%, respectively, as compared with the Provisional Tolerable Weekly Intake (PTWl) established by Joint FAO/WHO Expert Committee for food safety evaluation.