• 제목/요약/키워드: ICNIRP(international Commission on Non-Ionizing Radiation Protection)

검색결과 11건 처리시간 0.02초

VVVF 인버터로 구동되는 전기철도차량에서 방출되는 시변 저주파 전자계 분석 (Analysis of time-varying low-frequency electric magnetic field emitted from electric rolling stocks fed by VVVF inverter)

  • 장동욱;김주락;김형철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.507-513
    • /
    • 2010
  • This paper is described the analysis of time-varying low-frequency electric magnetic field emitted from electric rolling stocks fed by VVVF inverter, in reference to allowable magnitude for exposures to time-varying electromagnetic field issued by International Commission on Non-Ionizing Radiation Protection(ICNIRP). The level of the magnetic field strength was measured, in reference to the standard for occupational environments, which takes into account the public person's protection against the excessive emission of the low-frequency magnetic field, 5 Hz ~ 2 kHz.

  • PDF

멀티미디어 무선통신기기의 인체보호 기준 및 측정방법

  • 신찬수;최동근;김남;오학태;성주영
    • 한국전자파학회지:전자파기술
    • /
    • 제15권3호
    • /
    • pp.91-101
    • /
    • 2004
  • SAR(Specific Absorption Rate: 전자파 흡수율)이란 생체조직이 단위 질량당 흡수하는 전력(W/kg)으로 ICNIRP(International Commission on Non-ionizing Radiation Protection: 국제비전리방사위원회)국제 규격에서는 10 g평균 첨두 SAR 값을 인체 전신 및 국부(두부 및 몸통)에 대해 각각 0.08 W/kg과 2 W/kg으로 규정하고 있고, 미국의 FCC 규격에서는 국부노출의 경우 1 g 평균 첨두 SAR 값을 1.6 W/kg 값으로 제한하고 있다. (중략)

Realistic Head Phantom for Evaluation of Brain Stroke Localization Methods Using 3D Printer

  • Lee, Juneseok;Bang, Jihoon;Choi, Jaehoon
    • Journal of electromagnetic engineering and science
    • /
    • 제16권4호
    • /
    • pp.254-258
    • /
    • 2016
  • In this paper, a brain phantom for evaluating brain stroke localization is proposed. To evaluate brain stroke localization, a phantom imitating three-dimensional (3D) simulation environment is needed. Mold for the proposed phantom was printed by a 3D printer and the interior of the phantom consists of 5 different brain tissue materials. Each of the brain tissue materials has the conductivity and permittivity similar to those of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) standards for a frequency band from 0.5 to 2 GHz.

인체 통신에 따른 인체 주변에서의 전기장 분포 계산 및 전송 손실 연구 (Calculation of the Electromagnetic Fields Distribution around the Human Body and Study of Transmission Loss Related with the Human Body Communication)

  • 주영준;김윤명
    • 한국전자파학회논문지
    • /
    • 제23권2호
    • /
    • pp.251-257
    • /
    • 2012
  • 인체 통신이란 사람의 몸통이나 피부를 전송 매질로 하여 데이터를 송수신하는 통신 방식을 의미한다. 본 논문에서는 인체 피부 표면에 닿아 있는 자유 공간을 전송 매체로 하여 데이터를 전달하는 전송 방식에 대하여, 10~30 MHz 주파수 범위에서 5 MHz 간격으로 5개의 주파수에 대하여 송수신부 사이의 전기장 분포에 대하여 수치 해석하였다. 채널 손실 계산은 총 29종의 조직으로 구성되어 있는 한국형 남성 표준 인체 모델에 상용의 툴을 사용하여 실행하였다. 계산 주파수에 따른 인체 조직의 도전율과 비유전율을 해석 파라미터로 입력하여 송수신부로 간주되는 손등 위에서 전기장 분포를 계산하였다. 손등에 부착된 송신기에 의한 전자파비(比)흡수율(SAR: Specific Absorbtion Rate) 값을 계산한 후, 국제비전리복사방호위원회(ICNIRP: International Commission on Non-Ionizing Radiation Protection) 인체 보호 기준과 비교하였다. 또한, 수치 해석으로 구한 전기장을 선(線)적분하여 인접한 극판들 사이의 전압들을 계산하였고, 송신부와 수신부의 전압의 비(比)를 채널 손실로 정의하였다. 수치 해석 결과, 10~30 MHz 주파수 대역에서 채널 손실의 범위는 약 ($75{\pm}1$) dB로 주파수에 따른 채널 손실의 변화가 크지 않았다.

2.4 GHz의 무선전력전송에 사용되는 4 × 8 배열 안테나에 대한 인체안전성평가 (Human Safety Assessment for a 4 × 8 Array Antenna Used for Wireless Power Transfer at 2.4 GHz)

  • 주영준;김준희;이유리;김윤명;임용석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2018년도 추계학술대회
    • /
    • pp.338-341
    • /
    • 2018
  • Beam-forming 방식을 적용한 배열 안테나의 무선전력전송(WPT)은 송신기와 수신기를 접촉하지 않고 서로 떨어져도 높은 효율의 무선전력전송이 가능하다. 하지만 이 방식은 송신기와 수신기의 떨어진 거리에 따른 전자파에 대한 인체안전기준을 만족해야 사용할 수 있다. 본 논문에서는 시뮬레이션을 통해 2.4 GHz용 $4{\times}8$ 배열 안테나를 모델링하고 배열 안테나의 단일 안테나에 각각 1W의 2.4 GHz 정현파를 인가하여 배열 안테나로부터 떨어진 거리에 따른 전기장 세기 및 머리에 대한 10 gram 평균 SAR (Specific Absorption Rate)를 구하였다. 그리고 이 값들과 2018 ICNIRP (International Commission on Non-Ionizing Radiation Protection) 가이드라인 초안의 인체안전기준치와 비교하였다. 그 결과, 원거리장의 전기장 세기로부터 도출된 전력밀도가 $33.257W/m^2$로 직업인에 대한 전력밀도의 인체안전기준치는 만족하나 일반인에 대한 전력밀도의 인체안전기준치를 초과하였다. 10 gram 평균 SAR 또한 인체안전 기준치를 초과하였다.

  • PDF

6.78 MHz 무선전력전송 시스템에 의한 전자파 노출량 분석 (Analysis of Electromagnetic Wave Exposure Due to 6.78 MHz Wireless Power Transfer System)

  • 윤석;정현종;임영석
    • 한국전자파학회논문지
    • /
    • 제28권12호
    • /
    • pp.954-963
    • /
    • 2017
  • 본 연구에서는 공진형 무선전력전송시스템에 의해 발생되는 자기장과 전기장 강도 및 이에 의한 인체 내부 전자파 비흡수율(Specific Absorption Rate: SAR) 분포를 분석하였다. 연구에서 사용된 동작주파수는 ISM 대역에 해당하는 6.78 MHz이다. 실제 시스템을 제작하고, 시스템의 송신측에 공급되는 가용 전력을 1 W로 제한하여 전기장 및 자기장 분포를 측정하고, 동일한 규격으로 시뮬레이션한 결과와 비교하였다. 피부, 지방, 근육의 순으로 조직층이 구성된 단순인체모델을 이용하여, WPT 시스템으로부터의 거리에 따른 인체 내부의 유도 전류밀도와 SAR 분포를 구하였다. 측정과 시뮬레이션을 통해 얻어진 전자파 노출 정도를 ICNIRP(International Commission on Non-Ionizing Radiation Protection)의 국제 권고기준과 비교하여 분석하였다.

전투원 신체 주변 통신기기의 인체 노출량 분석 (Analysis of Human Exposure for Wireless Devices Near War-Fighter)

  • 서민경;최증원;고종환;이현성;박주만;백정기
    • 한국전자파학회논문지
    • /
    • 제24권1호
    • /
    • pp.106-112
    • /
    • 2013
  • 본 논문에서는 전투원이 착용할 수 있는 무선기기에 의한 인체영향 분석을 위해 인체의 다양한 위치에 송신 안테나를 위치시키고, 각 위치별로 송신기에 의한 인체영향을 분석하였다. 다양한 송신 안테나의 위치에 대해 분석하였다. 송신 안테나의 위치에 대한 시나리오는 전장에서 전투원이 통신기기를 착용할 수 있는 위치를 고려하여 국방과학연구소와 협의 하에 도출하였으며, 인체 전신 모델은 한국전자통신연구원(ETRI: Electronics and Telecommunications Research Institute)의 한국인 성인 남성 표준 모델을 사용하여 송신 안테나의 위치에 따른 전자파 흡수율(SAR: Specific Absorption Rate)을 국내 및 국제비전리복사방호위원회(ICNIRP: International Commission on Non-Ionizing Radiation Protection)의 인체 보호 기준과 비교하였다. 또한, 전장에서 전투원이 취할 수 있는 자세를 고려하여, 2가지 전형적인 자세에 대해서도 인체 노출량을 분석하였다.

Cross-Shaped Magnetic Coupling Structure for Electric Vehicle IPT Charging Systems

  • Ren, Siyuan;Xia, Chenyang;Liu, Limin;Wu, Xiaojie;Yu, Qiang
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1278-1292
    • /
    • 2018
  • Inductive power transfer (IPT) technology allows for charging of electric vehicles with security, convenience and efficiency. However, the IPT system performance is mainly affected by the magnetic coupling structure which is largely determined by the coupling coefficient. In order to get this applied to electric vehicle charging systems, the power pads should be able to transmit stronger power and be able to better sustain various forms of deviations in terms of vertical, horizontal direction and center rotation. Thus, a novel cross-shaped magnetic coupling structure for IPT charging systems is proposed. Then an optimal cross-shaped magnetic coupling structure by 3-D finite-element analysis software is obtained. At marking locations with average parking capacity and no electronic device support, a prototype of a 720*720mm cross-shaped pad is made to transmit 5kW power at a 200mm air gap, providing a $1.54m^2$ full-power free charging zone. Finally, the leakage magnetic flux density is measured. It indicates that the proposed cross-shaped pad can meet the requirements of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) according to the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA).

송전선로 주변의 3차원 자기장 및 인체 유도 와전류 계산 (ELF 3D Magnetic Field and Eddy Current Calculation of Human Body Around Transmission Lines)

  • 명성호;이동일;신구용;한인수;박종근
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권10호
    • /
    • pp.485-491
    • /
    • 2002
  • Since Wertheimer and Leeper reported possible adverse health effects of magnetic field in 1979, worldwide researches on this issue have been conducted. More recently, the U.S. Congress instructed the NIEHS (National Institute of Environmental Health Sciences), NIH (National Institute of Health) and DOE (Department of Energy) to direct and manage EMF RAPID (Electric and Magnetic Fields Research and Public Information Dissemination) program aimed at providing scientific evidence to clarify the potential for health risks from exposure to extremely low frequency electric and magnetic fields(ELF-EMF). Although they concluded that the scientific evidence suggesting adverse health risks of ELF-EMF is weak, the exposure to ELF-EMF cannot be recognized as entirely safe. Therefore, the purpose of this article is to describe magnetic field 3-D calculation and to evluate eddy current of human body compare to international guide line recognized one of the basic problems. In open boundary problem, Magnetic field using FEM is not advantageous in the point of the division of area and the proposition of the fictitious boundary. Therefore, we induced the analytic equation of magnetic field calculations so but the finite line segment based on Biot-Savarts law Also, Eddy currents induced due to ELF-EMF magnetic field are computed. To calculate induced currents, impedance method is used in this paper, An example model of human head with resolution of 1.27cm is used. In this paper, We evaluate the magnetic field and eddy current of human head around 765 kV transmission lines compare to international guide line.

휴대용 손 선풍기의 극저주파 자기장 발생 수준 평가와 쟁점 고찰 (Discussion of Exposure Evaluation Associated with Extremely Low Frequency-magnetic Field in the Case of Portable Hand-held Fans)

  • 박동욱;이성진;김소연;배서연;최상준;김원;민승현;박지훈;안종주
    • 한국환경보건학회지
    • /
    • 제44권5호
    • /
    • pp.480-490
    • /
    • 2018
  • Objective: This study aimed to report the level of extremely low frequency-magnetic field (ELF-MF) emitted by portable hand-held fans (HHF) and to discuss the methodologies for determining the health risk of ELF-MF for HHF products. Method: ELF-MF was monitored at eight locations by distances in the vicinity of HHFs. A total of 13 HHF brands on the market were randomly selected. A portable ELF-MF monitor MDEX II was used to measure the ELF-MF level in the range of 40-800 Hz with a resolution of $0.01{\mu}T$. This study also examined the frequency results of a total of 45 HHF products investigated by the Korean Ministry of Science and ICT (KMSICT). Results: ELF-MF higher than $0.3{\mu}T$ was found to be emitted at a distance of less than 20 cm from 12 HHF. ELF-MF emitted from four products was found to exceed the reference level ($83.3{\mu}T$ based on 60 Hz) recommended by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). KMSIT reported that the principle frequency emitted from the HHFs ranged from 54 Hz to 284 kHz, without the level of LEF-MF. Unscientifically, the KMSICT used the reference level by ICNIRP as the chronic level and concluded that all HHFs are safe with a basis of 1.2-36.0% less than the reference level. Conclusion: The HHF emitted much higher levels of ELF-MF than $0.3-0.4{\mu}T$, which is regarded as the reference level for childhood leukemia. The risk of HHF should be examined in terms of whether they can be used by the general public, including children and pregnant woman.