• Title/Summary/Keyword: ICDS

Search Result 16, Processing Time 0.028 seconds

An analysis of Deconcentration Tendencies and Shifting -Share Situations of ICDs: Focused on the Southern Vietnam (내륙 컨테이너 기지의 탈 집중화 및 전이할당 현상 분석: 베트남 남부지역을 중심으로)

  • Phan, Minh Tien;Yeo, Gi-Tae
    • Journal of Digital Convergence
    • /
    • v.18 no.6
    • /
    • pp.143-156
    • /
    • 2020
  • In Southern Vietnam, the competition among Inland Clearance Depot (ICD) has resulted in deconcentration tendencies and shifting share situations. However, related research on Southern Vietnam ICDs in particular and ICDs in Vietnam in general has been extremely limited. Hence, In this study, empirical research is conducted on ICDs located in southern Vietnam from 2010 to 2017. The throughput volume data of ICDs is analyzed by concentration indicators, namely the concentration ratio (CR), the Herfindahl-Hirschman Index (HHI), the Gini coefficient, the Lorenz curve, and the shift share analysis (SSA). The results of adopting all the methodologies indicate that deconcentration was the mainstream trend for ICDs in Southern Vietnam during the period of 2010-2017. The findings provide insights into the process of container terminal development and have academic and managerial implications. The strengthening of the competitiveness of Vietnamese container ports and ICDs could affect the competing Southeast Asian neighbors by facilitating the port of more shipping companies.

Effects of Static Magnetic Fields of Earphones and Headphones on Pacemakers and Implantable Cardioverter Defibrillators (이어폰 및 헤드폰의 정자기장이 인공심장 박동기 및 이식형 제세동기에 미치는 영향)

  • Chung, J.W.;Choi, S.B.;Park, J.S.;Kim, D.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.1
    • /
    • pp.31-36
    • /
    • 2015
  • In this study, we evaluated the effects of static magnetic fields of earphones and headphones on pacemakers and implantable cardioverter defibrillators(ICDs). Five pacemakers and three ICDs were subjected to in-vitro test with three headphones which were an in-ear earphone, clip-on headphone, and closed-back headphone. Each implantable device was placed in close proximity(within 3 mm) to the ear-pad of each of the earphone and headphones for 3 min. As a result, no effects were observed on the pacemakers for the earphone and headphones during the test, but an effect was observed on one ICD for the clip-on and closed-back headphone during the test. When the ICD was placed in close proximity to the headphones, the ICD temporarily suspended functions of tachyarrhythmia detection and therapy. The effect was not observed in this study when the headphones were at least 2 cm from the ICD. Based on these findings, patients with ICDs should be advised to keep earphones and headphones at least 2 cm apart from their ICDs.

Impulse Control Disorders associated with Pramipexole/Ropinirole Use in Non-Parkinson's Disease: A Scoping Review (파킨슨 병 이외의 적응증을 가진 환자의 Pramipexole 혹은 Ropinirole 사용과 관련된 충동 조절 장애: 주제 범위 문헌 고찰)

  • Jeong, Tae hyun;Suh, Seoung Min;Song, Hyun Jin;Jeon, Nakyung
    • Korean Journal of Clinical Pharmacy
    • /
    • v.30 no.4
    • /
    • pp.250-258
    • /
    • 2020
  • Background: Dopamine receptor agonists (DRAs) have been associated with impulse control disorders (ICDs) in Parkinson's disease (PD) in preliminary studies. Whether the association holds true when DRAs are used to treat non-PD, such as restless legs syndrome, prolactinoma, and several mood disorders is uncertain. Objective: The present study aimed to understand the research gaps related to the risk of ICDs associated with pramipexole or ropinirole (PRX/ROP) use as a treatment for specific underlying diseases, excluding Parkinson's disorders. Methods: We conducted a scoping review, systematically searching databases to identify literature on the types, prevalence, and factors associated with ICD in non-PD patients receiving PRX/ROP. All relevant information that helped understand the epidemiology of ICDs among non-PD patients taking PRX/ROP were extracted and analyzed. We also evaluated the potential associations between PRX/ROP and ICDs, utilizing the Naranjo scale or statistical analysis, depending on the type of literature. Results: We included 24 articles (19 case reports or case series and 5 population-based studies) in this scoping review. Evaluating the 19 case reports or case series using Naranjo scores led to the discovery of a possible link between PRX/ROP exposure and ICDs. However, important information to assess causality is frequently missing. Moreover, the population-based studies lack diversity in the study populations and enough study samples to draw conclusive results. Conclusion: Our scoping review suggests that the currently available literature requires more details in future case reports and for well-powered studies in various disease conditions where PRX/ROP is frequently used.

Effects of Radio Frequency Electromagnetic Fields Emitted by WCDMA Mobile Phones on Pacemakers and ICDs (WCDMA 휴대전화 전자파가 인공심장 박동기 및 이식형 제세동기에 미치는 영향)

  • Chung, Jai Won;Choi, Soo Beom;Park, Jee Soo;Kim, Deok Won
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.1
    • /
    • pp.148-154
    • /
    • 2015
  • Reports show that global system for mobile communication (GSM) mobile phones, or two-generation (2G) mobile phones, could affect functions of pacemakers and implantable cardioverter defibrillators (ICDs). In this study, we evaluated the effects of radio frequency electromagnetic fields (RF-EMFs) emitted by wideband code division multiple access (WCDMA) mobile phones, which were third-generation (3G) mobile phones, on pacemakers and ICDs. Five pacemakers and three ICDs were subjected to in-vitro test using a ECG simulator. We used a WCDMA module (average power : 0.25 W, frequency band : 1950 MHz) instead of a real WCDMA mobile phone. To assess the effects of the WCDMA module on pacemakers and ICDs, each implantable device was placed in close proximity (within 3 mm) to the WCDMA module for 5 min. As a result, no effects were observed on the five pacemakers and three ICDs for the RF-EMFs emitted by the WCDMA module. Because WCDMA mobile phones have the higher frequency band (1800-2200 MHz) and lower power output (0.01-0.25 W) than GSM moboile phone, the RF-EMFs emitted by WCDMA mobile phones do not affect patients with pacemaker or ICD.

Freight Terminal Site Selection Using the Analytic Hierarchy Process: A Case Study on the Youngnan Freight Terminal (계층분석방법을 이용한 화물터미널 입지선정에 관한 연구 - 영남권 내륙화물기지 사례를 중심으로 -)

  • Ahn, Seung-Bum;Kim, Eui-Jun;Byeon, Eui-Seok
    • IE interfaces
    • /
    • v.16 no.1
    • /
    • pp.34-43
    • /
    • 2003
  • The Korean government has been working to reduce national logistics costs since the early 1990s. One of the major plans instituted by the government was to build five complex freight terminals using ICDs(inland container depots) as hub inland terminals. This paper explains the process and the methods adopted for site selection, with special focus on the Youngnam Freight Terminal. Among nineteen developable sites in Youngnam region, four candidates were selected based on the Map Overlay Approach under several criteria, including land acquisition costs, proximity to major highways and railroads, suitability of the terrain, etc. In this study, we used the AHP to select the best site among the four sites.

Mortality Analysis of Implantable Cardioverter Defibrillator (ICD) (체내제세동기 이식 시의 사망률분석)

  • Park, Kwang-Il
    • The Journal of the Korean life insurance medical association
    • /
    • v.30 no.2
    • /
    • pp.12-15
    • /
    • 2011
  • Background: The beneficial effects of implantable cardioverter defibrillators (ICDs) in primary and secondary prevention patients are well established. However, data on potential differences between both groups in mortality are scarce. The aim of this study was to assess extra risk differences between primary and secondary prevention ICD recipients. Methods: Comparative mortality figures were calculated from a source article using mortality analysis methods. Results: Mortality ratio (MR) of primary and secondary prevention ICD recipients were 393% and 373%. Excess death rates (EDR) of both groups were 42 and 38 per 1,000. Discussion: MR and EDR were higher in primary prevention group. But, there was no significant difference.

  • PDF

Implantable cardioverter defibrillator therapy in pediatric and congenital heart disease patients: a single tertiary center experience in Korea

  • Jin, Bo Kyung;Bang, Ji Seok;Choi, Eun Young;Kim, Gi Beom;Kwon, Bo Sang;Bae, Eun Jung;Noh, Chung Il;Choi, Jung Yun;Kim, Woong Han
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.3
    • /
    • pp.125-129
    • /
    • 2013
  • Purpose: The use of implantable cardioverter defibrillators (ICDs) to prevent sudden cardiac death is increasing in children and adolescents. This study investigated the use of ICDs in children with congenital heart disease. Methods: This retrospective study was conducted on the clinical characteristics and effectiveness of ICD implantation at the department of pediatrics of a single tertiary center between 2007 and 2011. Results: Fifteen patients underwent ICD implantation. Their mean age at the time of implantation was $14.5{\pm}5.4$ years (range, 2 to 22 years). The follow-up duration was $28.9{\pm}20.4$ months. The cause of ICD implantation was cardiac arrest in 7, sustained ventricular tachycardia in 6, and syncope in 2 patients. The underlying disorders were as follows: ionic channelopathy in 6 patients (long QT type 3 in 4, catecholaminergic polymorphic ventricular tachycardia [CPVT] in 1, and J wave syndrome in 1), cardiomyopathy in 5 patients, and postoperative congenital heart disease in 4 patients. ICD coils were implanted in the pericardial space in 2 children (ages 2 and 6 years). Five patients received appropriate ICD shock therapy, and 2 patients received inappropriate shocks due to supraventricular tachycardia. During follow-up, 2 patients required lead dysfunction-related revision. One patient with CPVT suffered from an ICD storm that was resolved using sympathetic denervation surgery. Conclusion: The overall ICD outcome was acceptable in most pediatric patients. Early diagnosis and timely ICD implantation are recommended for preventing sudden death in high-risk children and patients with congenital heart disease.

Verification of a Relationship between Ultraviolet Radiation and Initial Microalgal Cell Density Using a Floating Marine Photobioreactor (부유형 해양 광생물반응기를 이용한 자외선과 초기 미세조류 접종 농도와의 상관관계 규명)

  • Kim, Z-Hun;Park, Hanwool;Jung, Seong-Gyun;Kim, Su-Kwon;Kim, Hee-Yun;Park, Yong Sung;Hong, Han Ma Roo;Lee, Choul-Gyun
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.7 no.2
    • /
    • pp.52-57
    • /
    • 2015
  • The purpose of this study was to investigate a relationship between ultraviolet radiation and initial cell density (ICD) of microalgae using a floating marine photobioreactor (PBR). To examine the effect of ultraviolet (UV) radiation in sunlight on biomass productivity as a function of ICD, 0.5-L floating PBRs covered with or without UV cut-off film were placed in an outdoor rectangular tank containing 200 L of water. At the lower ICDs, 0.01 and 0.05 g/L, biomass productivities in the PBRs without UV cut-off film decreased by $278{\pm}21%$ and $222{\pm}3%$ compared with those with the film, respectively. In contrast, the presence of UV cut-off film did not have a significant effect on biomass productivities at the higher ICDs, 0.25 and 1.25 g/L. When the differences in biomass productivity made by the UV cut-off film were plotted against the sum of cell projection area per light receiving area of the PBR, the results revealed that the inhibitory effect of UV on biomass productivity can be negligible when the sum of cell projection area is equal to the light receiving area of the PBR. These results show that photoinhibition caused by UV radiation could be eliminated via operating the PBR with a proper ICD.

Effects of EAS Systems on Pacemakers and ICDs Malfunction (도난방지 시스템의 전자기장이 인공심장 박동기 등의 오동작에 미치는 영향)

  • Shim, Young-Woo;Kim, Jong-Jeong;Yang, Dong-In;Lee, Moon-Hyung;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.6
    • /
    • pp.44-49
    • /
    • 2009
  • EAS (electronic article surveillance) systems have increased rapidly for article surveillance. In this paper, the strength of the EMF (electromagnetic fields) of EAS systems were measured. Pacemaker and ICD were investigated for inappropriate response resulting from EM (electromagnetic) EAS systems. The strength of EMF and the response of pacemaker and ICD were measured in the inner left side, outer right sides and the center of gates of the 6.3 kHz and 14.25 kHz EAS systems at a height of 130cm. As the result, EMF of the EAS system using 14.25 kHz was stronger than that of 6.3 kHz. AU interferences were observed only for 14.25 kHz, and the noisy ECG was found in three static positions on the pacemaker. The ICD resulted in noise reversion and VF (ventricular fibrillation) both static and moving positions by the EMP of 14.25 kHz EAS system. Therefore, it is necessary to post a message warning radiation of EMF from every EAS systems and possible risk of pacemakers and ICDs.

Intrapericardial Implantation of an Implantable Cardioverter-Defibrillator in a Child

  • Seong, Yong-Won;Kim, Woong-Han;Yoo, Jae-Suk;Kim, Hye-Seon;Min, Byoung-Ju;Lee, Young-Ok
    • Journal of Chest Surgery
    • /
    • v.44 no.1
    • /
    • pp.61-63
    • /
    • 2011
  • Implantable cardioverter defibrillator (ICD) can be a crucial therapeutic modality for pediatric patients with congenital heart disease, Brugada syndrome, long QT syndrome and cardiomyopathy. Because transvenous implantation of ICD is mostly unfeasible for pediatric patients due to anatomical and technical limitations, epicardial patch type or subcutaneous type ICD have been used. Implantation of these alternative ICDs, however, was reported to be frequently associated with significant complications. We report a case of successful intrapericardial implantation of a single coil-type ICD through the transverse sinus in a 27 month-old child weighing lesser than 10 kg, and it was inferred from this experience that this alternative technique may decrease complications and morbidities after ICD implantation in children.