• Title/Summary/Keyword: ICC Profile

Search Result 25, Processing Time 0.019 seconds

Reliability and Validity of Gait Assessment Tools for Elderly Person (노인의 보행에 대한 평가 도구의 신뢰도와 타당도 조사 연구)

  • Kim, Jae-Hyun
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.1
    • /
    • pp.41-48
    • /
    • 2009
  • Purpose: The examine the Reliability and Validity of the modified Emory Functional Ambulation Profile (mEFAP), Tinetti. Gait (TG), Timed Up & Go Tes t (TUG), Comfortable Gait Speed (CGS), Berg Balance Scale (BBS) in assessing gait function and balance in elderly person. Methods: The 45 community-dwelling subjects were participated in this study. Reliability was determined by intra-class correlation coefficient (ICC$_{3,1}$), Bland and Altman method (Standard Error of Measurement (SEM), Smallest Real Difference (SRD)). Results: Validity was examined by correlation the mEFAP, TG, TUG, CGS, BBS. The intra-rater reliability were High (ICC$_{3,1}$ : mEFAP=0.95, TG=0.96, TUG=0.94, CGS=0.96, BBS=0.92) and Absolute reliability were excellent (SEM: mEFAP=1.90, TG=0.21, TUG=0.28 CGS=0.25, BBS=0.52), (SRD: mEFAP=5.26, TG=0.58, TUG=0.77, CGS=0.69, BBS=1.44). There were significant correlations between assessment tool (r=.0.58$\sim$0.78, p<0.01) indicating good validity. Our results provide strong evidence that the assessment tool has good reliability, validity for assessing elderly person undergoing rehabilitation. Conclusion: The gait assessment tool is a useful scale for measuring walking function and recovery in elderly person.

  • PDF

Hue Preserving Color Gamut Mapping (색조 보존을 위한 칼라 색역 매핑)

  • 성영모;박은홍;임재권
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2003.06a
    • /
    • pp.106-109
    • /
    • 2003
  • This paper presents a hue preserving gamut mapping algorithm for color monitor and printer. The gamuts of monitor and printer are set by the profile of color reproduction media, specified by ICC(International Color Consortium) and provided by vendors, then those gamuts are represented on the CIE xy color space. In case that the color of monitor are located on out-of-gamut of printer, these are clipped on the point of gamut boundary of printer towards a reference white point. On the other hand, colors are in-gamut of printer are unchanged. An image generated by the algorithm keeps a ratio of each pixel of original image. Advantages of the algorithm are easy to implement and fast processing time than other algorithms which involve hue preserving especially in CIELAB color space.

  • PDF

Observer Variation Factor on Advanced Method for Accurate, Robust, and Efficient Spectral Fitting of java Based Magnetic Resonance User Interface for MRS data analysis (java Based Magnetic Resonance User Interface의 Advanced Method for Accurate, Robust, and Efficient Spectral Fitting 분석방법의 관찰자 변동 요소)

  • Lee, Suk-Jun;Yu, Seung-Man
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.143-148
    • /
    • 2016
  • The purpose of this study was examined the measurement error factor on AMARES of jMRUI method for magnetic resonance spectroscopy (MRS) quantitative analysis by skilled and unskilled observer method and identified the reason of independent observers. The Point-resolved spectroscopy sequence was used to acquired magnetic resonance spectroscopy data of 10 weeks male Sprague-Dawley rat liver. The methylene protons ($(-CH_{2-})n$) of 1.3 ppm and water proton ($H_2O$) of 4.7 ppm ratio was calculated by LCModel software for using the reference data. The seven unskilled observers were calculated total lipid (methylene/water) using the jMRUI AMARES technique twice every 1 week, and we conducted interclass correlation coefficient (ICC) statistical analysis by SPSS software. The inter-observer reliability (ICC) of Cronbach's alpha value was less than 0.1. The average value of seven observer's total lipid ($0.096{\pm}0.038$) was 50% higher than LCModel reference value. The jMRUI AMARES analysis method is need to minimize the presence of the residual metabolite by identified metabolite MRS profile in order to obtain the same results as the LCModel.

Influence of heritability on craniofacial soft tissue characteristics of monozygotic twins, dizygotic twins, and their siblings using Falconer's method and principal components analysis

  • Song, Jeongmin;Chae, Hwa Sung;Shin, Jeong Won;Sung, Joohon;Song, Yun-Mi;Baek, Seung-Hak;Kim, Young Ho
    • The korean journal of orthodontics
    • /
    • v.49 no.1
    • /
    • pp.3-11
    • /
    • 2019
  • Objective: The purpose of this study was to investigate the influence of heritability on the craniofacial soft tissue cephalometric characteristics of monozygotic (MZ) twins, dizygotic (DZ) twins, and their siblings (SIB). Methods: The samples comprised Korean adult twins and their siblings (mean age, 39.8 years; MZ group, n = 36 pairs; DZ group, n = 13 pairs of the same gender; and SIB group, n = 26 pairs of the same gender). Thirty cephalometric variables were measured to characterize facial profile, facial height, soft-tissue thickness, and projection of nose and lip. Falconer's method was used to calculate heritability (low heritability, $h^2$ < 0.2; high heritability, $h^2$ > 0.9). After principal components analysis (PCA) was performed to extract the models, we calculated the intraclass correlation coefficient (ICC) value and heritability of each component. Results: The MZ group exhibited higher ICC values for all cephalometric variables than DZ and SIB groups. Among cephalometric variables, the highest ${h^2}_{(MZ-DZ)}$ and ${h^2}_{(MZ-SIB)}$ values were observed for the nasolabial angle (NLA, 1.544 and 2.036), chin angle (1.342 and 1.112), soft tissue chin thickness (2.872 and 1.226), and upper lip thickness ratio (1.592 and 1.026). PCA derived eight components with 84.5% of a cumulative explanation. The components that exhibited higher values of ${h^2}_{(MZ-DZ)}$ and ${h^2}_{(MZ-SIB)}$ were PCA2, which includes facial convexity, NLA, and nose projection (1.026 and 0.972), and PCA7, which includes chin angle and soft tissue chin thickness (2.107 and 1.169). Conclusions: The nose and soft tissue chin were more influenced by genetic factors than other soft tissues.

Psychometric Characteristics of Korean Version of Life Balance Inventory (K-LBI) and Relationship Between Life Balance and Sensory Processing (한국판 삶의 균형 척도의 심리측정적 특성 및 감각 처리와의 관련성)

  • Kim, Eun Young;Lee, Sun Wook;Kim, Young;Lee, Sang-Heon;Kim, Heyjin;Gwon, Jung-A
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.16 no.2
    • /
    • pp.36-49
    • /
    • 2018
  • Objective : The purpose of this study was to examine the validity and reliability of the Korean version of Life Balance Inventory (K-LBI) and to present the relationship between life balance and sensory processing. Methods : K-LBI was constructed through forward and backward translation. Convergent validity, internal consistency, and test-retest reliability were tested for college students. To verify convergent validity, correlation analyses between K-LBI and Korean version of Perceived Stress Scale, Korean version of Satisfaction With Life Scale, and Adult Self Report-Achenbach system of empirically based assessment were performed. Split-half reliability and test-retest reliability were also obtained for reliability verification. We performed the correlation analysis between K-LBI and Korean version of Adolescent/Adult Sensory Profile. Results : A significant correlation was found between K-LBI and the scales for convergent validity. A favorable split-half reliability and test-retest reliability were calculated. The positive correlations were found between relationship life balance and sensory sensitivity/sensation avoiding quadrants. The negative correlation was found between challenges life balance and low registration. Conclusion : This study shows that K-LBI is a valid and reliable tool in Korea. It also provides an in-depth understanding of the relationship between life balance and sensory processing.