• Title/Summary/Keyword: ICC(Intraclass Correlation Coefficients)

Search Result 61, Processing Time 0.03 seconds

Comparison of the reproducibility of panoramic radiographs between dentulous and edentulous patients

  • Park, Jong-Woong;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.95-102
    • /
    • 2014
  • Purpose: This study was performed to evaluate the reproducibility of panoramic radiographs of dentulous and edentulous patients. Materials and Methods: The reproducibility of panoramic radiographs was evaluated using the panoramic radiographs acquired from 30 anterior dentulous patients by using a common biting positioning device (dentulous group) and 30 anterior edentulous patients by using chin-support devices to take a panoramic radiograph (edentulous group), respectively; these patients had undergone 3 or more panoramic radiographs. The widths and angles between the designated landmarks were measured on the panoramic radiographs, and the reproducibility was evaluated using the intraclass correlation coefficient (ICC) and the coefficient of variation. Results: In the dentulous and edentulous groups, the ICCs of the mandibular ramus and mandibular angle areas were higher than the condylar head and zygomatic areas. The mandibular ramus and angle areas showed statistically lower mean coefficients of variation than the condylar head and zygomatic areas in the dentulous group. The mandibular angle area showed a significantly lower mean coefficient of variation than the zygomatic area in the edentulous group. By comparing the two groups, each ICC of the edentulous group was lower than that of the dentulous group, and the mean coefficients of variation of the mandibular ramus area, zygomatic area, left condylar inclination, and ramus ratio between the right and the left in the edentulous group were significantly higher than those in the dentulous group. Conclusion: Biting positioning for dentulous patients provided better positioning reproducibility than chin-support positioning when performing panoramic radiography for edentulous patients.

Validation of a Needs Assessment Tool for Case Management in Korean Medical Aid Beneficiaries (의료급여수급권자의 사례관리 요구측정도구의 타당도와 신뢰도 검증)

  • Ahn, Yang-Heui;Kim, Eui-Sook;Ham, Ok-Kyung;Kim, Soo-Hyun;Kim, Soon-Ok;Song, Myung-Kyung
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.4
    • /
    • pp.549-558
    • /
    • 2012
  • Purpose: The purpose of this study was to validate the Needs Assessment Tool for Case Management (NATCM) for use with Korean medical aid beneficiaries. Methods: Psychometric testing was performed with a sample of 645 Korean medical aid beneficiaries, which included 41 beneficiaries who were selected using proportional sampling method, to examine intraclass correlation coefficients (ICC). Data were evaluated using item analyses, exploratory factor analysis (EFA), confirmatory factor analysis (CFA), Cronbach's alpha, and ICC. Results: Through psychometric testing the final version of NATCM was found to consist of two subscales: 1) Appropriateness of Health Care Utilization (5 items) and 2) Self Care Ability (6 items). The two subscale model was validated by CFA (RMSEA=.08, GFI=.97, and CFI=.93). Internal consistency measured by Cronbach's alpha was .82, and subscale reliability ranged from .79 to .84. The ICC of the NATCM between case managers was .73 and between case managers and health care professionals. .82. Conclusion: This study suggests that the final version of NATCM is a brief, reliable, and valid instrument to measure needs of Korean medical aid beneficiaries. Therefore, the NATCM can be effectively utilized as an important needs assessment as well as outcome evaluation tool for case management programs in Korea.

Inter-Examiner Reliability of the Korean Version of the Pediatric Balance Scale (한글판 아동 균형척도(Pediatric Balance Scale)의 측정자간 신뢰도)

  • Ko, Myung-Sook;Lee, Nam-Hyun;Lee, Jung-Ah;Jeon, Hye-Seon
    • Physical Therapy Korea
    • /
    • v.15 no.1
    • /
    • pp.86-95
    • /
    • 2008
  • The Pediatric Balance Scale (PBS) is a modified Berg's Balance Scale developed as a balance measure for school-aged children with mild to moderate motor impairments. The purpose of this study was to determine the inter-examiner reliability of the Korean version of PBS when applied to children with developmental delays. In this study, PBS was administrated to a total of 79 children with developmental delays (17 with global developmental delay, 31 with cerebral palsy, and 31 with mental retardation) in the Seoul Community Rehabilitation Center. Two pediatric trained physical therapists with longer than 13 year of clinical experience scored the children's performance blind, while replaying videotaped data. The inter-examiner reliability was statistically determined by intraclass correlation coefficients (ICCs). The results of this study revealed that the Korean version of PBS seems to have high inter-examiner reliability when applied to children with movement disorders such as global developmental delay (ICC=.96) and cerebral palsy (ICC=.97); however, it has relatively lower inter-examiner reliability (ICC=.78) for children with developmental delay secondary to mental retardation. therefore, the results support that the Korean version of the PBS could be a useful clinical measurement to assess the balance skills for children with developmental delay who have an adequate level of cognition to enable them to fol1ow the verbal instructions to complete the test.

  • PDF

Assessment of Isometric Muscle Strength of Shoulder Girdle: A Reliability Study (어깨와 견갑대 근육의 등척성 근력 평가)

  • Hong, Wan-Sung;Kim, Gi-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.6
    • /
    • pp.17-22
    • /
    • 2007
  • Purpose: To evaluate the quantitative isometric muscle strength of shoulder girdle and the test reliability using by the equipment, named 'IsoTrack', selected by authors in the former studies. Methods: Thirty healthy subjects (9 men, 21 women) were recruited in two sessions, one for intratester and intertester reliability tests and the other quantitative isometric muscle strength tests. The neck flexion, extension and scapular elevation muscle strength was measured using a force measuring device as IsoTract. Results: Intraclass correlation coefficients for intratester reliability of the all subjects ranging between 0.96 and 0.97. For intertester reliability, the ICC and Pearson correlation correspond to 0.84 and 0.78. We gauged muscle strength of shoulder girdle muscles based on it and indicated quantified isometric muscle strength of women and men in left and right side. Conclusion: We concluded that there were high reiliability of isometric muscle strength of neck and shoulder girdle. Also, we gauged muscle strength of shoulder girdle muscles based on it and indicated quantified isometric muscle strength in left and right side in women and men. So this findings may assist in the measure of whole body muscle strength.

  • PDF

Development of a Pain Assessment Tool for Critically Ill Patients (중환자 통증사정 도구 개발)

  • Choi, Eun Hee;Kim, Jin Hee;Choi, Kyung Ok;Yoo, Jung Sook;Kim, Mi Soon;Kim, Pil Ja;Jang, In Sun
    • Journal of Korean Clinical Nursing Research
    • /
    • v.18 no.1
    • /
    • pp.136-148
    • /
    • 2012
  • Purpose: The purpose of this study was to develop a reliable and valid pain assessment tool suitable for critically ill patients with communication problem in Korean intensive care unit. Methods: This pain assessment tool, Critical Care Non-verbal Pain Scale (CNPS), was developed based on review of national and international researches. Data were collected from ten intensive care units at five major general hospitals in Seoul. Reliability and validity were tested during performance of position change and endotracheal suctioning. Pain was measured before, during, and 20 minutes after the two procedures. Results: Interrater reliability of the CNPS was analyzed by ICC (Intraclass correlation coefficients). ICC values were significant from .833 to .883. Significant correlation between the FPS (Face Pain Scale) scores and the CNPS scores verified concurrent validity of the CNPS. For position change, CNPS scores increased significantly between before and during (t=-23.399, p<.001) and decreased significantly between during and 20 minutes after (t=22.760, p<.001). For endotracheal suctioning, CNPS scores increased significantly between before and during (t=-29.064, p<.001) and significantly decreased between during and 20 minutes after (t=28.194, p<.001), verifying construct validity of the CNPS. Conclusion: Results indicate that the CNPS can be used to assess pain of critically ill patients who have communication problem.

Segmental Liver Stiffness Evaluated with Magnetic Resonance Elastography Is Responsive to Endovascular Intervention in Patients with Budd-Chiari Syndrome

  • Peng Xu;Lulu Lyu;HaitaoGe;Muhammad Umair Sami;Panpan Liu;Chunfeng Hu;Kai Xu
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.773-780
    • /
    • 2019
  • Objective: To assess segmental liver stiffness (LS) with MRI before and after endovascular intervention in patients with Budd-Chiari syndrome (BCS). Materials and Methods: Twenty-three patients (13 males and 10 females; mean age, 42.6 ± 12.6 years; age range, 31-56 years) with BCS as a primary liver disease were recruited for this study. Two consecutive magnetic resonance elastography (MRE) examinations were performed before the endovascular treatment. Fifteen patients who underwent endovascular intervention treatment also had follow-up MRE scans within three days after the procedure. LS was measured in three liver segments: the right posterior, right anterior, and left medial segments. Inter-reader and inter-exam repeatability were analyzed with intraclass correlation coefficients (ICCs) and Bland-Altman analysis. Segmental LS and clinical characteristics before and after the intervention were also compared. Results: Within three days of the endovascular intervention, all three segmental LS values decreased: LS of the right posterior segment = 7.23 ± 0.88 kPa (before) vs. 4.94 ± 0.84 kPa (after), LS of the right anterior segment = 7.30 ± 1.06 kPa (before) vs. 4.77 ± 0.85 kPa (after), and LS of the left medial segment = 7.22 ± 0.87 kPa (before) vs. 4.87 ± 0.72 kPa (after) (all p = 0.001). There was a significant correlation between LS changes and venous pressure gradient changes before and after treatments (r = 0.651, p = 0.009). The clinical manifestations of all 15 patients significantly improved after therapy. The MRE repeatability was excellent, with insignificant variations (inter-reader, ICC = 0.839-0.943: inter-examination, ICC = 0.765-0.869). Bland-Altman analysis confirmed excellent agreement (limits of agreement, 13.4-19.4%). Conclusion: Segmental LS measured by MRE is a promising repeatable quantitative biomarker for monitoring the treatment response to minimally invasive endovascular intervention in patients with BCS.

The Reliability and Validity of Figure-of-8 Walk Test in Patients with Stroke (뇌졸중 환자에서 Figure-of-8 walk test의 신뢰도와 타당도)

  • Kim, Yang-Ho;Lim, Jae-Heon
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2012
  • Purpose : The purpose of this study was to establish intra-rater, inter-rater, test-retest reliability, and concurrent validity of figure-of-8 walk test in people with stroke. Methods : The subjects of this study were 17 patients who were diagnosed with a stroke. Subjects were tested twice by the same raters, with 1 day between tests. Subjects were assessed by two physical therapists. Test-retest reliability was calculated using intraclass correlation coefficients (ICC). The concurrent validity was demonstrated by spearman correlation of F8WT with 10m walking test (10MWT), timed up and go test (TUG), Berg balance scale (BBS), dynamic gait index (DGI) and four square step test (FSST). Results : Intra-rater, inter-rater, test- retest of F8WT time, showed high reliability. Intra-rater, inter-rater, test-retest of F8WT steps demonstrated high reliability. Intra-rater, inter-rater, test-retest of F8WT total smoothness score showed below moderate reliability. There was a significant positive correlation of F8WT time with 10MWT, TUG, FSST. There was a significant negative correlation of F8WT time with DGI, BBS. There was a significant positive correlation of F8WT steps with 10MWT, TUG, FSST. There was a significant negative correlation of F8WT steps with DGI. There was a significant positive correlation of F8WT test total smoothness score with BBS. Conclusion : The time, and number of steps in F8WT show high inter, intra-rater, test-retest reliability. The F8WT smoothness shows below moderate reliability. The F8WT shows high concurrent validity with other comparable balance, and walking tests. The F8WT is a valid and reliable measure for assessing walking function in patients with a stroke.

Interrater Reliability of Upper Extremity Function Assessment on Stroke (뇌졸중 환자에 대한 상지기능 평가도구의 검사자간 신뢰도)

  • Hwang, Seong-Soo;Kim, Pu-Reum;Won, Ji-In;Yoo, Seon-Ju;Yoon, Jun-Byung;Lee, Keun-Woo;Lee, Wang-Jae
    • PNF and Movement
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • Purpose : To verify the interrater reliability of upper extremity function assessment among three tools(Wolf motor function test, Motor assessment scale, Fugl-meyer assessment scale). Methods : The subjects of this study 40 (20 was physical therapists and 20 was physical therapy students). For the test one patients with chronic hemiparesis after stroke participated in the study. The Wolf Motor Function Test consists of 16 functional tasks. The motor assessment scale consists of 3 functional tasks. The fugl-meyer assessment scale consists of 8 functional tasks. All test sessions were videotaped and scored by 40 subjects. Analysis : The data was analysis by SPSS PC 14.0 with Cronbach alpha Coefficients, intraclass Correlation Coefficients Kendall tau-b value. Results : WMFT was highly scored in Cronbach's value, Cronbach's ${\alpha}=0.819$ that means high interrater reliability among assessment. WMFT was highly scored all items in p-value except one item, that means high p-value between therapists and students. WMFT was highly scored in Intrarater correlation coefficient (ICC) = 0.79, that means high interrater reliability of each examination item. WMFT was low index of coincidence from all items, MAS was low index of coincidence from a tim and FMA was low index of coincidence from 4 items. Conclusion : The interrater reliability of WMFT were compared with MAS, FMA and highly verified. WMFT can be more useful tool among upper extremity function assessment.

Cross-cultural Adaptation and Psychometric Evaluation of the Korean Version of the A-ONE (한국판 일상생활활동중심 작업기반 신경행동평가(A-ONE)의 개발 및 평가)

  • Kang, Jaewon;Park, Hae Yean;Kim, Jung-Ran;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.10 no.2
    • /
    • pp.109-128
    • /
    • 2021
  • Objective : The purpose of this study was to develop a Korean version of the Activities of Daily Living (ADL)-focused Occupation-Based Neurobehavioral Evaluation (A-ONE) through cross-cultural adaptation and examine its validity and reliability. Methods : This study translated the A-ONE into Korean and performed cross-cultural adaptation for the Korean population. After the development of the Korean version of the A-ONE, cross-cultural and concurrent validities were analyzed. Internal consistency, test-retest reliability, and inter-rater reliability were also evaluated. Results : We adapted three items to the Korean culture. The Korean version of the A-ONE showed high cross-cultural validity with a content validity index (I-CVI) >0.9. It correlated with the Functional Independence Measure (FIM) (r=0.52-0.77, p<0.001), except for communication. Cronbach's α was 0.58-0.93 for the functional independence scale (FI) and 0.42-0.93 for the neurobehavioral specific impairment subscale (NBSIS). Intraclass correlation coefficients (ICCs) indicated high test-retest and inter-rater reliability for FI (ICC=0.79-1.00 and 0.75-1.00, respectively) and NBSIS (ICC=0.74-1.00 and 0.72-1.00, respectively). Conclusion : The Korean version of the A-ONE is well adapted to the Korean culture and has good validity and reliability. It is recommended to evaluate ADL performance skills and neurobehavioral impairments simultaneously in Korea.

Reliability of the Active Knee Extension Test With a Pressure Biofeedback Unit

  • Kim, Chang-ho;Gwak, Gyeong-tae;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.24 no.3
    • /
    • pp.40-46
    • /
    • 2017
  • Background: The active knee extension (AKE) test commonly used to assess the flexibility of the hamstring muscles. Many researchers have tested the reliability of the AKE test; however, no published studies have examined the intrarater and interrater reliability of the AKE test using a PBU. Objects: The purpose of this study was to determine the intrarater and interrater reliability of the AKE test performed with a pressure biofeedback unit (PBU) on healthy subjects. Methods: Sixteen healthy male participants volunteered and gave informed consent to participate in this study. Two raters conducted AKE tests independently with a PBU. Each knee was measured twice, and the AKE testing was repeated one week after the first round of testing. Results: The interrater reliability's intraclass correlation coefficients ($ICC_{2,1}$) were .887~.986 for the right knees and .915~.988 for the left knees. In addition, the intrarater (test-retest) reliability ($ICC_{3,1}$) values ranged between .820~.915 and .820~.884 for Raters 1 and 2, respectively. The values for the standard error of mesurement were low for all tests ($.81{\sim}2.97^{\circ}$); the calculated minimum detectable change was $2.24{\sim}8.21^{\circ}$. Conclusion: These findings suggest that the AKE test performed with a PBU had excellent interrater and intrarater reliability for assessing hamstring flexibility in healthy young males.