• Title/Summary/Keyword: ICB

Search Result 46, Processing Time 0.025 seconds

A case study of verifying a suicide by carbon monoxide intoxication committed by burning an ignition charcoal briquette (착화탄 연소에 의한 일산화탄소 중독사에서 자살입증에 관한 사례연구)

  • Sung, Tae-myung;Jo, Ju-ik;Ahn, Phil-sang
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.398-408
    • /
    • 2015
  • Carbon monoxide (CO) intoxication, arising from CO from an ignited charcoal briquette (ICB), is a popular means of committing suicide in Korea. Most CO intoxications are related to suicide attempts; however, the possibility of a homicide disguised as a suicide cannot be ruled out. Therefore, forensic investigation of the deceased and the crime scene is crucial to confirm that the deceased committed suicide. Detection of the components of an ICB on the objects suspected of being contacted by the deceased, such as the hands, nostrils, and doorknobs, is essential for linking the crime scene to the victim in the case of suicides by ignited ICBs. The traces from an ICB were analyzed by investigating the morphological characteristics and obtaining elemental compositions. The ICBs were completely different from blackened wood, as detected by discriminant analysis with the elements of carbon and oxygen. We analyzed one case of CO intoxication to demonstrate an excellent procedure for verifying whether a suicide occurred with an ICB. We employed SEM-EDX for the analysis of an ICB, microscope-FT/IR and pyrolysis-GC/MS for a partly burnt resin-type substance, GC/MS for diphenhydramine (a sleeping drug), and GC/TCD for the CO-Hb level. We detected traces of an ICB on the hands, nostrils, and doorknobs, which were all discriminated into an ICB group. Detection of ICB traces from the nostrils could indicate that the deceased started the fire themselves to commit suicide. The partially burnt black material was analyzed as an acrylronitrilestyrene polymer, which is normally used to make bags for carrying or wrapping and could be assumed to have been used to transport the ICB. Diphenhydramine, a sleeping drug, was detected at a level of 2.3 mg/L in the blood, which was lower than that in fatal cases (8-31 mg/L; mean 16 mg/L). A CO-Hb level of 79% was found in the blood, which means that the cause of death was CO intoxication. The steps shown here could represent an ideal method for reaching a verdict of suicide by CO intoxication produced by burning an ICB in a sealed room or a car.

Copper Film Growth by Chemical Vapor Deposition: Influence of the Seeding Layer (ICB seeding에 의한 CVD Cu 박막의 증착 및 특성 분석)

  • Yoon, Kyoung-Ryul;Choi, Doo-Jin;Kim, Seok;Kim, Ki-Hwan;Koh, Seok-Keun
    • Korean Journal of Materials Research
    • /
    • v.6 no.7
    • /
    • pp.723-732
    • /
    • 1996
  • Cu films were deposited by chemical wapor deposition on the as-received substrates (TiN/Si) and three kinds of Cu-seeded substrates (Cu/TiN/Si) which had seeding layer in the thick ness of 5 ${\AA}$ and 130 ${\AA}$ coated by ICB(Ionized Cluster Beam) method. The effect of Cu seeding layers on the growth rate, crystallinity, grain size uniformity and film adhesion strength of final CVD-Cu films was investigated by scanning eletron microscopy(SEM), X-ray diffractometry and scratch test. The growth rate was found to incresase somewhat in the case of ICB-seeding. The XRD patterns of the Cu films on the as-received substrate and ICB Cu-seeded substrates exhibited the diffraction peaks corresponding to FCC phase, but the peak intensity ratio($I_{111}/I_{200}$) of Cu films deposited on the ICB Cu-seeded substrates increased compared with that of Cu films on the as-received substrate. The resistivity of final Cu film on 40 ${\AA}$ seeded substrate was observed as the lowest value, 2.42 $\mu\Omega\cdot$cm compared with other Cu films. In adhesion test, as the seeding thickness increased from zero to 130 ${\AA}$, the adhesion strength increased from 21N to 27N.

  • PDF

A cumulative survival rate of implants installed on posterior maxilla augmented using MBCP after 2 years of loading: A retrospective clinical study (MBCP를 이용하여 거상된 상악 구치부에 식립한 임플란트의 기능 후 2년 누적 생존율 - 후향적 임상 연구)

  • Kim, Min-Soo;Lee, Ji-Hyun;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.4
    • /
    • pp.669-678
    • /
    • 2008
  • Purpose: The purpose of this study was to evaluate 2 years cumulative survival rate of implants on augmented sinus area using MBCP, mixture of MBCP and ICB, and mixture of MBCP and autogenous bone by means of clinical and radiologic methods. Materials and Methods: In a total of 37 patients, 41 maxillary sinuses were augmented and 89 implant fixtures were installed simultaneously or after a regular healing period. The patients were divided in 3 groups: MBCP only, MBCP combined with ICB, MBCP combined with autogenous bone. After delivery of prosthesis, along 2 years of observation period, all implants were evaluated clinically and radiologically. And the results were as follows. Results: The results of this study were as follows. 1. A 2 year cumulative survival rate of implants placed with sinus augmentation procedure using MBCP was 97.75%. 2. Survival rate of implants using MBCP only was 97.62%, MBCP and ICB was 100%, MBCP and autogenous bone was 95%. There was no statistically significant difference between 3 groups. 3. Only 2 of 89 implants were lost before delivery of prosthesis, so it can be regarded as an early failure. And both were successfully restored by wider implants. Conclusion: It can be suggested that MBCP may have predictable result when used as a grafting material of sinus floor augmentation whether combined with other graft(ICB, autogenous bone) or not. And the diameter, length, location of implants did not have a significant effect on 2 year cumulative survival rate.

A Study on the Dependence of Length for the Electromigration in the Dielectric Passivation Overlayered AI-1%Si Thin Film Interconnections and the Electromigration Resistance of Cu Thin Film Interconnetions (절연보호막 처리된 AI-1% 박막배선의 Electromigration에 대한 길이 의존성 및 Cu 박막배선의 Electromigration 저항성 변화에 대한 연구)

  • 양인철;김진영
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.4
    • /
    • pp.380-385
    • /
    • 1995
  • AI-1%Si 박막배선에서 수명의 길이 의존성 및 EM에 대한 저항성을 절연보호막 및 온도에 대하여 관찰하였고 ICB증착된 Cu박막배선의 EM에 대한 저항성을 측정하여 진공 열증착된 Cu 박막배선과 비교하였다. 첫째, 절연보호막 처리된 AI-1%Si 박막배선에서 길이가 200$\mu$m에서 1200$\mu$m로 증가함에 따라 전류인가에 의한 평균 수명과 활성화에너지값이 감소하다가 임계길이서부터는 모두 포화되는 것으로 나타났다. 절연보호막 물질에 상관 없이 고온으로 갈수록 임계길이가 짧아지며 그것을 넘는 영역에서는 길에에 대한 의존성이 약해져 임계길이 이상을 갖는 박막배선인 경우 평균수명 및 활성화 에너지값은 길이보다 막특성에 의존하는 것으로 사료된다. 둘째, ICB 증착된 Cu 박막배선의 d.c.인가에 따른 평균 수명은 진공 열층착된 Cu 박막배선보다 길게 나왔으며 e.ectromigration에 대한 활성화 에너지값도 1.70eV로 1.33eV보다 높게 측정되어 EM에 대한 저항성이 증가한 것으로 나타났다.

  • PDF

Analysis of the Three Phase Inductor-Converter Bridge Circuit by Means of State-Space Averaging Method (상태변수평균화법에 의한 삼상ICB회로 해석)

  • Park, Min-Ho;Hong, Soon-Chan;Oh, Soo-Hong
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.394-398
    • /
    • 1988
  • In this paper, the time-averaged behavior of the three-phase Inductor-Converter Bridge (ICB) circuit has been analyzed by using the state-space averaging method. The results are in closed form far from the results obtained by using the Fourier series. Therefore, the computational difficulties of the infinite Fourier series can be avoided and the results derived in this paper are available especially in real time control. Unlike the SFC, $S^{4}LCL$, DFC and other circuits which have time varying switching intervals for a constant time-averaged value of coil voltage, the ICB circuits operate with a clock-driven sequence of gate pulses which have constant switching intervals.

  • PDF

Analysis of crystalline structure of autogenous tooth bone graft material: X-Ray diffraction analysis (자가치아골이식재의 결정구조 분석: X선 회절 분석)

  • Kim, Gyung-Wook;Yeo, In-Sung;Kim, Su-Gwan;Um, In-Woong;Kim, Young-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.3
    • /
    • pp.225-228
    • /
    • 2011
  • This study evaluated the mineral crystalline structure of an autogenous tooth bone graft material. The crystalline structures of the autogenous tooth bone graft material enamel (AutoBT E+), dentin (AutoBT D+), xenograft (BioOss), alloplastic material (MBCP), allograft (ICB) and autogenous mandibular cortical bone were compared using XRD. The XRD pattern of AutoBT dentin and ICB was similar to that of autogenous bone.

Analysis of the Three Phase Inductor-Converter Bridge Circuit by Means of State-Space Averaging Method. (상태변수 평균화법에 의한 삼상 ICB회로 해석)

  • Park, Min-Ho;Hong, Soon-Chan;Choy, Ick;Oh, Soo-Hong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.9
    • /
    • pp.701-709
    • /
    • 1989
  • The time-averaged behavior of the three-phase Inductor-Converter Bridge (ICB) circuit has been analyzed by using the state-space averaging method. Especially, a second order approximation in the matrix expansion makes the analysis possible. The results are in a closed form which is quite different from the conventional solution obtained by using the Fourier Series. Therefore, the computational difficulties in evaluating the infinite Fourier series can be avoided and the results derived in this paper are available expecially in real time control. By comparing with the Fourier result, it has been verified that the analysis by means of the state-space averaging method is more accurate and simple. The digital simulation and the equivalent experiments have also been carried out to confirm the theoretical results.

  • PDF