• Title/Summary/Keyword: IC Method

Search Result 1,050, Processing Time 0.025 seconds

An Improved Synthesis Method of Parametric Stereo Coding Based on Tonality Information (토널리티 정보를 기반으로 한 파라메트릭 스테레오 부호화의 개선된 합성 기법)

  • Lee, Tung chin;Park, Young-Cheol;Youn, Dae Hee
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.221-227
    • /
    • 2014
  • In this paper, we propose a synthesis method that can effectively suppress the ambience which affects tonal components in the PS decoder. Ambience component was obtained by using decorrelation filter and the weighting of the ambience in the decoder was determined through IC parameter. However, since the parameters are extracted in the sub-band domain, a low IC value could be analyzed even if the tonal component is dominant. The quality of the output signal may be degraded. To prevent this problem, the tonality was measured in the downmixed signal and the weighting of the ambience components were adjusted appropriately according to the measured tonality index. The performance of the proposed method was evaluated by simulations. Furthermore, the subjective test was performed and the results confirmed that the proposed method offers improved quality.

Design of Digital Correction Circuits Using Microprocessor (마이크로 프로세서를 이용한 디지털 보정회로 설계)

  • Jun, Ho-Ik;Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2291-2293
    • /
    • 2011
  • In this paper, the composes with digital position with a computer logical operation order with the signal processing method which is pliability and result of the logical operation which confronts in input signal from the outside input-output Channel leads and about the drive which the possibility to output at the outside is a research. This Decoder IC Multiplexer & De-multiplexer, position the function with from the digital signal circle where the imagination embodiments and BIT outputs of IC etc. are possible is possible in basic and usefully from the general industrial, could be used.

The Embedded 8V-to-12V CMOS DC-DC Converter for a Mobile Battery-Powered System (휴대용 배터리 구동 시스템을 위한 8V-12V 내장형 CMOS DC-DC 컨버터)

  • Oh, Won-Seok;Lee, Seung-Eun;Lee, Sung-Chul;Park, Jin;Choi, Jong-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2577-2579
    • /
    • 2002
  • In this paper, we describe a CMOS DC-DC converter with a variable output voltage(8-12V @100mA) for a portable battery-operated system applications. The proposed DC-DC converter is used along with a Pulse-Frequency Modulation (PFM) method and consists of a reference circuit, a feedback resistor, a controller, and an internal oscillator. The integrated DC-DC converter with two external passive components(L.C) has been designed and fabricated on a 0.6${\mu}m$ 2-poly, 3-metal CMOS process and could be applied to the Personal Digital Assistants(PDA), Cellular Phone, Laptop Computer, etc.

  • PDF

Implementation of the Electronic Prescription Security System Using by an If Card (IC 카드에 의한 원외 전자처방전 보안을 위한 시스템 구축)

  • Kang, Se-Na;Lee, Ki-Han
    • The KIPS Transactions:PartC
    • /
    • v.10C no.3
    • /
    • pp.281-286
    • /
    • 2003
  • Nowadays, a patient's private medical data which is exposed to the outside world has a severe effect on not only the patient's private life but also his/her social activities and environment. So, it is important to securely protect the patient's private medical data from the illegal manipulation. This paper studies the method to store the electronic prescription information in an IC card. For that, an access control for users, such as a doctor, a nurse, a medical institute member, a pharmacy, a pharmacist, or a patient, is proposed to access the data stored in an IC card. The certificate is issued using the Crypto API of a certificate management model supported by Windows 2000. The public/private key is created by the Cryptographic Service Provider program, and the electronic prescription is signed using the digital signature. The proposed system, therefore, can improve the quality of medical services by securing the safety and integrity of the electronic prescription, stored in an IC card.

Analysis of Research Trends for BrIC Injury (BrIC 상해에 대한 경향 분석 및 고찰)

  • Lee, Kihwang;Kim, Kiseok;Yoon, Ilsung
    • Journal of Auto-vehicle Safety Association
    • /
    • v.8 no.4
    • /
    • pp.12-17
    • /
    • 2016
  • NHTSA (National Highway Traffic Safety Administration) has offered consumers the vehicle safety information on their car since 1978. NHTSA believes that they contribute auto makers to develop safer vehicle for customers, which will result in even lower numbers of deaths and injuries resulting from motor vehicle crashes. NHTSA has been studied why people are still dying in frontal test despite of the use of many restraints system and they understand that current test does not reflect real world crash data such as oblique and corner impact test. As a result, NHTSA announced that a new test method will be introduced to use of enhanced biofidelic dummy and new crash avoidance technology evaluation from 2019. New and refined injury criteria will be applied to Head / Neck / Chest / Lower Leg. BrIC(Brain Injury Criterion)value in NHTSA test results using THOR dummy from 2014 to 2015 was average 0.91 and 1.24 in driver and passenger dummies. IIHS 64kph SOF test is the most likely to new frontal oblique test in an aspect of offset impact which is being studied by NHTSA. In this paper, we focused on head injury, especially brain injury - BrIC and conducted IIHS 64kph SOF (Small Offset Front) test with Hybrid III dummy to evaluate the injury for BrIC. Based on the test results, these data can be predicted BrIC level and US NCAP rating with current vehicle.

PLL Control Method for Precise Speed Control of Slotless PM Brushless DC Motor Using 2 Hall-ICs (2 Hall-ICs를 이용한 Slotless PM Brushless DC Motor의 정밀속도제어를 위한 PLL 제어방식)

  • Yoon Y.H;Lee S.J;Kim Y.R;Won C.Y;Choe Y.Y
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.109-116
    • /
    • 2005
  • The high performance drives of the slotless Permanent Magnet Brushless DC(PM BLDC) motor can be achieved by the current control, where the currents flow according to the rotor position and the current phase is suitably controlled according to the operational condition. Rotor position information can be provided by Hall-IC or sensorless algorithm. So, the Hall-ICs are set up in this motor to detect the main flux from the rotor. Instead of using three Hall-ICs and encoder, this paper uses only two Hall-ICs for the permanent magnet rotor position and the speed feedback signals, and uses a micro-controller of 16-bit type (80C196KC). Also because of low resolution obtained by using Hall-IC even low-cost and simple structure, to improve the wide range of speed response characteristic more exactly, we propose the rotor position signal synthesizer using PLL circuit based on two Hall-ICs.

Selective Toxicity and Acetylcholinesterase Inhibition of Diazinon and Carbofuran to Killifish(Oryzias latipes) and Loach(Misgurnus anguillicaudatus) (Diazinon과 Carbofuran의 송사리(Oryzias latipes)와 미꾸리(Misqurnus anguillicaudatus)에 대한 선택적 독성과 Acetylcholinesterase저해)

  • Kim, Young-Bae;Lee, Sung-Kyu;Kim, Yong-Hwa;Roh, Jung-Koo
    • Korean Journal of Environmental Agriculture
    • /
    • v.7 no.2
    • /
    • pp.117-123
    • /
    • 1988
  • This study was initiated to understand the mechanism of selective toxicity of diazinon and carbofuran to killifish and loach. Conventional LC50 was calculated from fish test. IC50 with acetylcholinesterase activity was estimated using whole body and wet brain homogenate of the two fish species. Acetylcholinesterase activity of killifish was approximately twice as high as that of loach. The selective toxicity of diazinon to killifish and loach was partly (14 : 4) explained by the IC50 of diazoxon, a toxic metabolite of diazinon. IC50 of carbofuran also partly (14 : 3.4) contributed to the selectivity. These result suggested that the enzymatic method might be utilized as a screening tool for the chemicals affecting fish species of environmental concern with certain limitations which should be overcome in future studies.

  • PDF

Inhibitory Effect of Methanol Extract of Magnolia officinalis on Matrix Metalloproteinase-2

  • Lee, Dong-Yup;Kim, Cheorl-Ho;Kim, Dong-Soo
    • Preventive Nutrition and Food Science
    • /
    • v.11 no.3
    • /
    • pp.191-197
    • /
    • 2006
  • Matrix metalloproteinase-2 (MMP-2) is a key enzyme involved in tumor invasiveness. The plant of Magnolia officinalis Rehd. et Wils. is often included as an ingredient in various herbal remedies recommended for cancer theraphies in Korea. Various extracts prepared from stems of M. officinalis were tested for cytotoxic activity on human hepatocellular carcinoma cell line, SK-Hep cells using the XTT assay method. Then, the inhibitory effect was examined on MMP-2 activity using gelatin zymography. Methanol (MeOH) extract of M. officinalis caused the strongest inhibition of the MMP-2 activity, as measured by gelatin zymography method for enzyme activity. $IC_{50}$ values of fractions on MMP-2 activity were in a range of $4.9{\sim}11.3\;{\mu}g/mL$. Among each fraction, butanol and ethylacetate (EtOAc) fractions showed the strong inhibitory activities ($IC_{50}=10.7\;and\;4.9\;{\mu}g/mL$, respectively). When the M. officinalis's constituents such as magnolol, honokiol, (-)-epigallocatechin gallate (EGCG) and ovovatol were examined for inhibitory effects on MMP-2 activity, EGCG showed strong inhibitory activity. However, MeOH extract of M. officinalis was dose-dependently inhibited to MMP-2 activity. The MeOH extract, hexane and EtOAc fractions $(IC_{50}\;of\;>200\;{\mu}g/mL)$ exhibited weak cytotoxicity activity, while butanol $(IC_{50}=80\;{\mu}g/mL)$ and chloroform fractions $(IC_{50}=90\;{\mu}g/mL)$ exhibited relatively strong cytotoxic activity. From these results, M. officinalis could be suitable for cancer treatment and chemopreventive drugs.

The Application of Ion Chromatographic Method for Bioavailability and Stability Test of Iron Preparations

  • Kim, Young-Ok;Chung, Hye-Joo;Kong, Hak-Soo;Choi, Dong-Woong;Cho, Dae-Hyun
    • Archives of Pharmacal Research
    • /
    • v.22 no.3
    • /
    • pp.288-293
    • /
    • 1999
  • Postabsorptive serum iron level was determined after oral administration of the compounds to human. In serum and whole blood, $Fe^{3+}$ was measured by ion chromatography (IC) using a pyridine-2,6-dicarboxylic acid (PDCA) as an eluent. The serum sample solutions were pretreated with I N HCI and 50% TCA. The whole blood sample solutions were treated with 3 N HCI for 30 min at $125^{\circ}C$. The limit of detection (LOD) of the IC technique is $0.2 {\mu}M$ for$Fe^{2+}$and 0.1 $\mu$M for $Fe^{3+}$. The area under concentration (AUC) can be obtained by the above analytical condition. In addition, to compare the stability of $Fe^{2+}$ to that of $Fe^{3+}$ in pharamaceutical preparations, accelerated stability test was carried out. After storing the samples under $40^{\circ}C$, 75%RH in light-resistant container for various time intervals, the contents of iron of different valencies were determined separately by the IC technique and the change and/or the interchange of among those iron species in preparations was investigated. Iron raw materials are stable, but $Fe^{2+}$ in$Fe^{3+}$ source materials was slightly converted to $Fe^{3+}$ by oxidation. $Fe^{2+}$ in$Fe^{3+}$ source raw materials and $Fe^{3+}$ in $Fe^{2+}$ raw materials are determined as impurities. Therefore, IC technique is found to be an appropriate method for comparative evaluation of dissimilar bioavailability of $Fe^{2+}$ and $Fe^{3+}$, stability of $Fe^{2+}$ and $Fe^{3+}$ raw materials and preparations.

  • PDF

Detection of Korean Native Honey and European Honey by Using Duplex Polymerase Chain Reaction and Immunochromatographic Assay

  • Kim, Chang-Kyu;Lee, Deug-Chan;Choi, Suk-Ho
    • Food Science of Animal Resources
    • /
    • v.37 no.4
    • /
    • pp.599-605
    • /
    • 2017
  • Korean native honey (KNH) is much more expensive than European honey (EH) in Korea, because KNH is a favored honey which is produced less than EH. Food fraud of KNH has drawn attention of the government office concerned, which is in need of a method to differentiate between KNH and EH which are produced by the Asiatic honeybee, Apis cerana and the European honeybee, Apis mellifera, respectively. A method to discriminate KNH and EH was established by using duplex polymerase chain reaction (PCR) in this study. Immunochromatographic assay (IC) was examined to analyze the duplex PCR product. The DNA sequences of primers for the duplex PCR were determined by comparing cytochrome C oxidase genes of the two honey bee species. Chelex resin method was more efficient in extracting genomic DNA from honey than the other two procedures of commercial kits. The duplex PCR amplifying DNA of 133 bp were more sensitive than that amplifying DNA of 206 bp in detecting EH in the honey mixture of KNH and EH. Agarose gel electrophoresis and IC detected the DNA of 133 bp at the ratios of down to 1% and 5% EH in the honey mixture, respectively and also revealed that several KNH products distributed by internet shopping sites were actually EH. In conclusion, the duplex PCR with subsequent IC could also discriminate between KNH and EH and save time and labor.