Extension Possibility of Indoor Air Standards in Office Building by Health Risk Assessment (건강위해성평가에 의한 사무실 실내공기오염물질의 관리항목 확대)

  • Roh, Young-Man;Lee, Cheol Min;Kim, Yoon Shin;Kim, Seok Won;Kim, Chi-Nyon;Kim, Hyun-Wook;Cho, Kee Hong;Choi, Ho Chun;Kim, Jung Man
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.1
    • /
    • pp.54-67
    • /
    • 2006
  • This study was performed to deduct the extension possibility of the standards establishment for $NO_2$, $O_3$, Asbestos, Radon, total volatile organic compounds (TVOC) excluded in the indoor air part of Industrial Safety Acts in Korea. The air pollutants were sampled for 30 office buildings from August to September, 2005 in the metropolitan area. The airborne concentrations of $NO_2$, $O_3$, Radon and TVOC were 0.0092 ppm, 0.0035 ppm, 0.57 pCi/L and $423{\mu}g/m^3$, respectively. The management plan and reduction methods is required in the aspect of indoor air quality(IAQ) because the emission sources of those also exist in indoor as well as outdoor even though those were not exceeded the standards of the Ministry of Environment in Korea. The standard for TVOC in the new and remodeling office has to be established based on the risk assessment when hazard index exceeded "1" in the worst case scenario. In the state of art, the management of each volatile organic compounds has a difficulty due to not enough data for toxicological reference. Therefore, it is suggested that first of all, the standard for TVOC be established and then expanded to each materials for decision-making of improvement of IAQ in office.

Comparison of Correlation between Total Airborne Bacteria and Particulate Matter in University Spaces (일부 학교 내 총부유세균 및 미세먼지의 상관성 비교)

  • Hyekyung Seo;Harim An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.2
    • /
    • pp.115-124
    • /
    • 2024
  • Objectives: The aim of this study is to assess indoor air quality within and around buildings and evaluate the health risks associated with exposure to indoor air pollution. The study compares IAQ standards established by the World Health Organization with those set by South Korea's Ministry of Environment and Ministry of Education. Methods: The study utilized an Anderson Sampler and DustTrakTM II to collect samples of total airborne bacteria and PM in indoor and outdoor environments. Collected samples were analyzed using biological and biochemical methods. Statistical analysis was conducted using SPSS to examine the correlation between airborne bacteria and PM. Results: The study revealed that the concentration of total airborne bacteria in indoor air generally remained below the Ministry of Environment's standard of 800 CFU/m3, although it surpassed this threshold in certain instances. PM concentrations did not exceed the standards. Indoor fine dust concentration was higher when there were people (P<0.05). There was no difference in total floating bacterial concentrations between indoor and outdoor environments (P=0.184). Finally, there was a correlation between fine dust and airborne bacteria concentrations. Conclusion: The study evaluated the concentrations of total airborne bacteria and PM in indoor air, emphasizing the importance of managing IAQ. Further research in various environments is essential to ensure a healthy indoor environment. The findings underscore the need for ongoing research and management to enhance IAQ and create safer and healthier living environments.

Removal Efficiency of PM10 & $CO_2$ in Subway Mock-up Cabin (지하철 목업차량내 객실 공기정화장치의 미세먼지(PM10) 및 $CO_2$ 저감성능평가)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jong-Bum;Cho, Goan-Hyun;Nam, Goong-Seok;Lee, Joo-Yeol;Kim, Tae-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.613-618
    • /
    • 2011
  • More than 7 million persons use Seoul Metropolitan Subways (SMS) everyday and the number has been in increasing trend. With the increasing trend of concerns on indoor air quality(IAQ), the management of IAQ has become an important issue, especially in case of subway operators, because most of subway lines are placed underground with poor ventilation condition. The ultimate object of study develop independent cleaning device that reduce efficient fine particle and $CO_2$. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. Two layered electrically pre-charged filters were used for removing particulate matters and gas absorbers are packed between two layer filters for removing gases pollutants such $CO_2$, VOCs and HCHO. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. SCAP prototype is producted as all in one method which decrease fine dust, $CO_2$ and noxious gas. and basic test carry out with quantity of wind, a gap of pressure, sampling efficiency.

  • PDF

Checklist and Design Recommendations for the Interiors of Korean, Eco-healthy Childcare Facilities (우리나라 영유아 보육시설의 친환경 실내를 위한 체크리스트와 디자인안 제안)

  • Chun, Jin Hie
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.105-114
    • /
    • 2010
  • As children are known to touch and chew everything, green cleaning procedures are an important step in preventing children from ingesting harmful toxins. The objectives of this study are to develop a new, self-evaluation checklist and to suggest design recommendations which comply with easy, adaptable, economical ways to improve the eco-friendly indoor environment of Korean childcare facilities. The information compiled during this study was collected through literature review and internet surveys1) from July, 2009 to February, 2010. The results of this study show that the current Korean childcare accreditation system and practices emphasize clean building interiors, policies for sanitation and cleanliness, and control of humidity and lighting. On the other hand, the information provided by green-building rating systems from GBCC, LEED, and GBTool offers additional and comparative details regarding indoor environment quality and standards regarding the IAQ performance and management plan, ventilation and thermal comfort systems, views from windows, acoustics, and lighting. In conclusion, this document provides an appropriate and easy-to-follow, self-evaluation checklist composed of eight criteria and 51 practical items. This study also provides the design recommendations composed of 27 practical ideas focusing on interior elements. Both the checklist and design recommendations I have suggested can be a post-occupancy tool for evaluating eco-healthy facility standards as well as tips for continuing to maintain eco-healthy childcare facilities.

A Comparative Study of a Domestic and Foreign Green Architecture Evaluation Items for a Green Performance Enhancement of Hospital Architecture (병원건축의 친환경 성능 향상을 위한 국내외 친환경 건축물 평가항목의 비교 연구)

  • Lee, Ho-Sung
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.1
    • /
    • pp.99-107
    • /
    • 2009
  • In order to prepare future green hospital architecture authentication system, this study is a comparative year report to Korean, the United States, Japanese, British, Canadian and Australian green building authentication systems. Also, the United States and Australian Green hospital authentication systems were examined, and the authentication items of hospitals were compared with those of civil architecture. Though the examination and analysis, the portion of indoor environmental quality section commonly shows the average of 20.7 percent in all 6 countries. Especially, IAQ(Indoor Air Quality) among inside IEQ(Indoor Environment Quality) is overwhelmingly much treated in Korea, the U.S.A, Canada and Australia. In Japan, heat, light and sound are the important factors for authentication evaluation, while in the U.K light are more emphasized for the authentication. 'LEED for Healthcare' as a hospital evaluation authentication system subdivided currently most. The system includes the detailed and extensive evaluation items ranging from hospital management, traffic, emission, water resources utilization to integrated design and furnishing. These overseas systems should be carefully investigated, researched and analyzed for an appropriate improvement of domestic green hospital authentication system. Also the current evaluation method of IEQ section of Korean GBCC needs to be modified. That's why the method puts too much importance on IAQ in IEQ section.

The Fine Dust Reduction Effect and Operational Strategy of Vegetation Biofilters Based on Subway Station Passenger Volume (지하역사 내 승하차 인원에 따른 식생바이오필터의 미세먼지 저감효과와 운전전략)

  • Jae Young Lee;Ye Jin Kim;Mi Ju Kim
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.13-18
    • /
    • 2023
  • A subway station is a prominent multi-purpose facility where the quantitative management of fine dust, generated by various factors, is conducted. Recently, eco-friendly air purification methods using air-purifying plants are being discussed, with the focus on biofiltration through vegetation. Previous research in this field has confirmed the reduction effects of transition metals such as Fe, which have been identified as harmful to human health. This study aimed to identify the sources of fine dust dispersion within subway stations and derive an efficient operational strategy for air-purifying plants that takes into account the behavior characteristics of fine dust within multi-purpose facilities. The experiment monitored regional fine dust levels through IAQ stations established based on prior research. Also, the data was analyzed through time-series and correlation analyses by linking it with passenger counts at subway stations and the frequency of train stops. Furthermore, to consider energy efficiency, we conducted component-specific power consumption monitoring. Through this study, we were able to derive the optimal operational strategy for air-purifying plants based on time-series comprehensive analysis data and confirm significant energy efficiency.

  • PDF

Development of Vortex Scrubber Using Electrolyzed Water for the Removal Efficiency Improvement of Minute Particles and Odor (미세분진 및 냄새제거 효율향상을 위한 선회류식 세정전해 기술개발)

  • Kim, Nor-Jung;Lim, Seong-Il;Kim, Sun-Mi;Kim, Sun-Uk;Kim, Lae-Hyun;Kim, Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.3
    • /
    • pp.1-7
    • /
    • 2010
  • According to Indoor Air Quality(IAQ) management law for multi-use buildings, SEEONE CO., Ltd. made pilot and tested it to remove minute particle, odor, VOCs, etc. within the standards of IAQ. This pilot made by SEEONE CO., Ltd. is vortex scrubber washing electrolyzed water. As 30 minutes test result in multi-use building indoor place, minute particle(the smoke of a cigarette) was reduced $920{\mu}g/m^3{\rightarrow}112{\mu}g/m^3$, gaseous contaminants was reduced Formaldehyde (HCHO) 20ppm$\rightarrow$4ppm, Ammonia($NH_3$) 50ppm$\rightarrow$1ppm, Trimethylamine ($(CH_3CH_2)_3N$) 15ppm$\rightarrow$trace, Methylethylketone($CH_3COC_2H_5$) 25ppm$\rightarrow$trace, Acetic acid ($CH_3COOH$) 20ppm$\rightarrow$trace, Acetaldehyde($CH_3CHO$) 15ppm$\rightarrow$2ppm and Acetone($CH_3COCH_3$) 50ppm$\rightarrow$N.D. The pilot test result of the air filter using electroyzed water in vortex scrubber showed high removal efficiency. Because purified air maintain indoor humidity of approximately 40~60%, so users can feel pleasant. In E.coli, S.aureus sterilization test and CODcr, turbidity treatment test by electrolysis, germs was sterilized over 99.99% and CODcr and turbidity was decreased gradually. So water used for washing can be reused by electrolysis.

Risk Assessment of Volatile Organic Compounds (VOCs) and Formaldehyde in Korean Public Facilities: Derivation of Health Protection Criteria Levels

  • Kim, Ho-Hyun;Lim, Young-Wook;Shin, Dong-Chun;Sohn, Jong-Ryeul;Yang, Ji-Yeon
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.121-133
    • /
    • 2011
  • This study suggests criteria to conduct a risk assessment of VOCs and formaldehyde in uncontrolled public facilities. Pollutants and facilities were selected based on two years of monitoring data and exposure scenarios in 573 uncontrolled public facilities, composed of 10 types of public institutions. With the exception of social welfare facilities, lifetime ECRs of formaldehyde and benzene in each facility were higher in employees than in users, except in social welfare facilities. In social welfare facilities, the risk of benzene for users ($1{\times}10^{-5}$) was higher than that of workers ($1{\times}10^{-6}$) because facility users live in the facility 24 hours per day, compared to workers who spend an average of 8 hours per day in the facility. The risk of benzene to workers in restaurants, academies, performance halls, internet cafe and pubs were estimated as high as $1{\times}10^{-4}$ and the risk to workers in the theaters and karaoke bars were recorded as $1{\times}10^{-5}$. Because lifetime ECRs of carcinogens exceeded $1{\times}10^{-4}$ for workers and users in most facilities, risk management of formaldehyde and benzene in these facilities is necessary. Although HQs of toluene and xylenes did not exceed 1.0, their HQs did exceed 0.1 in some facilities, so they were evaluated as potentially harmful materials. Additionally, criteria for health protection in IAQ by facility are suggested at $60-100\;{\mu}g/m^3$ for formaldehyde, $400-500\;{\mu}g/m^3$ for TVOCs, $10-20\;{\mu}g/m^3$ for benzene, $150-170\;{\mu}g/m^3$ for toluene and $100\;{\mu}g/m^3$ for xylenes, based on the survey on IAQ and HRA methodology. The excess rates of IAQ to health protection criteria in all facilities were 16% for formaldehyde, 8% for TVOCs and benzene, 9% for toulene, and 5% for xylenes.

Six Sigma and the Cost of(Poor) Quality

  • Aca;U, Jichao-X
    • International Journal of Quality Innovation
    • /
    • v.3 no.2
    • /
    • pp.159-173
    • /
    • 2002
  • Any organization's Six Sigma program may be at high risk without heeding the lessons learned from the past and that tries to operate without a robust business foundation. A foundation that preferably should consist of stepping-stones such as a 5-S house-keeping program, an effective Integrated Management System (IMS), which includes a strong focus on planning for quality to fully capture the Voice of the Customer (VOC), and an organization-wide training scheme, as well as a reliable Cost of Poor Quality (COPQ) system. That's the best advise I can give to any organization that wishes to embark on a Six Sigma improvement program and hope to be successful. The paper will elaborate on the above issues and provide suggested solutions based on the review of published historical information and the experiences encountered over the last four decades by the author, as a quality practitioner and consultant, in industries that produced safety-critical product. This author maintains that few fundamentally new or useful things have been created in the field of Quality during the last couple of decades. Nevertheless, this paper deliberates on a number of relatively “newer” issues including the concept of “three types of customers”, the CTC, “Critical To Customer” term, the eight Quality Management Principles of the new ISO 9000 family, the growth of industry-specific standards, the adoption of Integrated Management Systems, the rebirth of AS2561 COQ standard, the spread of Six Sigma as well as related ASQ certification and the need for a robust business foundation to ensure Six Sigma survival.

Review of Guidelines for Radon and Estimation of Radiation dose (라돈의 가이드라인 고찰 및 선량 예측)

  • Chung, Eun Kyo;Kim, Kab Bae;Jang, Jae Kil;Song, Se Wook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.2
    • /
    • pp.109-118
    • /
    • 2016
  • Objectives: To review reference levels by the international and domestic management and provide the basis for setting occupational exposure limits(OELs) of radon in Korea Methods: Government's organizations with laws and systems for monitoring radon exposure were investigated and compared. There are five laws governing Indoor Air Quality(IAQ) control such as Occupational Safety and Health Act, Indoor Air Quality Control in Public Use Facilities, Etc. Act, School Health Act, Public Health Control Act and Parking Lot Act in Korea. It was surveyed that a total of 32 countries including 24 countries in the European Union(EU), six countries in Asian and two countries in North America setting the reference levels for radon in the world. Results: In Korea, there are set guidelines for radon in the Ministry of Environment and the Ministry of Education. Reference levels of radon for existing dwellings were $150{\sim}400Bq/m^3$ for Western European countries, and $200{\sim}1,500Bq/m^3$ in Eastern European countries. Approximately 67% of those EU countries were set up $400Bq/m^3$ to the standards for existing dwellings. EU countries such as Luxembourg, Finland, Norway, Sweden and Russia had adopted mandatory level for radon. Radon guidelines for new dwellings were set more strictly reference level($200Bq/m^3$) than existing dwellings. Conclusions: International organizations such as ICRP, UNSCEAR and NCRP, etc. had recommended the guidelines for radon. It was calculated the relation of the dose conversion factors with the annual effective doses. the OELs of radon suggest to need to establish $150Bq/m^3$ for office room and $400{\sim}1,000Bq/m^3$ for the workplace.