• Title/Summary/Keyword: I.C.U.

Search Result 977, Processing Time 0.029 seconds

CONTROLLABILITY OF NONLINEAR DELAY PARABOLIC EQUATIONS UNDER BOUNDARY CONTROL

  • Park, Jong-Yeoul;Kwun, Young-Chel;Jeong, Jin-Mun
    • Journal of the Korean Mathematical Society
    • /
    • v.33 no.2
    • /
    • pp.333-346
    • /
    • 1996
  • Let $A(\zeta, \partial)$ be a second order uniformly elliptic operator $$ A(\zeta, \partial )u = -\sum_{j, k = 1}^{n} \frac{\partial\zeta_i}{\partial}(a_{jk}(\zeta)\frac{\partial\zeta_k}{\partial u}) + \sum_{j = 1}^{n}b_j(\zeta)\frac{\partial\zeta_j}{\partial u} + c(\zeta)u $$ with real, smooth coefficients $a_{j, k}, b_j$, c defined on $\zeta \in \Omega, \Omega$ a bounded domain in $R^n$ with a sufficiently smooth boundary $\Gamma$.

  • PDF

WEIGHTED INTEGRAL INEQUALITIES FOR MODIFIED INTEGRAL HARDY OPERATORS

  • Chutia, Duranta;Haloi, Rajib
    • Bulletin of the Korean Mathematical Society
    • /
    • v.59 no.3
    • /
    • pp.757-780
    • /
    • 2022
  • In this article, we study the weak and extra-weak type integral inequalities for the modified integral Hardy operators. We provide suitable conditions on the weights ω, ρ, φ and ψ to hold the following weak type modular inequality $${\mathcal{U}}^{-1}\({\int_{{\mid}{\mathcal{I}}f{\mid}>{\gamma}}}\;{\mathcal{U}}({\gamma}{\omega}){\rho}\){\leq}{\mathcal{V}}^{-1}\({\int}_{0}^{\infty}{\mathcal{V}}(C{\mid}f{\mid}{\phi}){\psi}\),$$ where ${\mathcal{I}}$ is the modified integral Hardy operators. We also obtain a necesary and sufficient condition for the following extra-weak type integral inequality $${\omega}\(\{{\left|{\mathcal{I}}f\right|}>{\gamma}\}\){\leq}{\mathcal{U}}{\circ}{\mathcal{V}}^{-1}\({\int}_{0}^{\infty}{\mathcal{V}}\(\frac{C{\mid}f{\mid}{\phi}}{{\gamma}}\){\psi}\).$$ Further, we discuss the above two inequalities for the conjugate of the modified integral Hardy operators. It will extend the existing results for the Hardy operator and its integral version.

A Heuristic for Dual Mode Routing with Vehicle and Drone

  • Min, Yun-Hong;Chung, Yerim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.9
    • /
    • pp.79-84
    • /
    • 2016
  • In this paper we consider the problem of finding the triplet (S,${\pi}$,f), where $S{\subseteq}V$, ${\pi}$ is a sequence of nodes in S and $f:V{\backslash}S{\rightarrow}S$ for a given complete graph G=(V,E). In particular, there exist two costs, $c^V_{uv}$ and $c^D_{uv}$ for $(u,v){\in}E$, and the cost of triplet (S,${\pi}$,f) is defined as $\sum_{i=1}^{{\mid}S{\mid}}c^V_{{\pi}(i){\pi}(i+1)}+2$ ${\sum_{u{\in}V{\backslash}S}c^D_{uf(u)}$. This problem is motivated by the integrated routing of the vehicle and drone for urban delivery services. Since a well-known NP-complete TSP (Traveling Salesman Problem) is a special case of our problem, we cannot expect to have any polynomial-time algorithm unless P=NP. Furthermore, for practical purposes, we may not rely on time-exhaustive enumeration method such as branch-and-bound and branch-and-cut. This paper suggests the simple heuristic which is motivated by the MST (minimum spanning tree)-based approximation algorithm and neighborhood search heuristic for TSP.

A Study on the Selection of Lightning Arrester for DC Electric Traction Vehicles (전기철도용 피뢰기 선정에 관한 연구)

  • Kil, G.S.;Song, J.Y.;Kim, I.L.;Moon, S.B.;Han, J.S.
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.581-586
    • /
    • 2006
  • Selection and application recommendations of lightning arresters for DC electric traction vehicles are presented. To decide arrester specification such as continuous operating voltage(COV, $U_c$), rated voltage($U_R$), and nominal discharge current($I_n$), variations of system voltage and surge currents flowing arresters were analyzed in running-service of traction vehicles. System voltages increased up to 1,800V during anti-breaking. Surge currents recorded 3 times per running-service-route and their magnitudes were ranges of $150A{\sim}2kA$. From the field measurement and consideration of EN50163, COV, $U_c$, and $U_R$ for the $1,500V_{DC}$ traction vehicles were proposed.

  • PDF

DEPENDENCE OF METAL CONCENTRATIONS OF METAL-TREATED ANTIBACTERIAL ACTIVATED CARBON FIBER AND THEIR APPLICATION (금속 처리된 항균성 활성탄소 섬유의 금속 농도의 의존성과 그의 응용)

  • Oh, Won-Chun;Kim, Bum-Soo;Jang, Won-Cheoul;Rheem, In-Soo;Kim, Jong-Wan
    • Proceedings of the KAIS Fall Conference
    • /
    • 2000.10a
    • /
    • pp.55-60
    • /
    • 2000
  • The adsorption isotherms can be assigned to typical Type I for Ag and Cu-treated ACFs and Type I and Type II for Ni-treated ACFs. From the DSC analysis, A $g_{0.9}$-ACF occurs only exothermic curve at the temperature of $203^{\circ}C$, and relatively stable composition curves were formed. But C $u_{0.3}$-ACF and C $u_{0.4}$-ACF occur endothermic curves at the temperature of 57.26, 107.02 and $215.87^{\circ}C$. N $i_{1.0}$-ACF occurs large endothermic curves at 59.26, 98.40 and $208.89^{\circ}C$ and N $i_{0.8}$-ACF are shown endothermic curves at 59.26 and $157.77^{\circ}C$. From the biological results, the percentages of the antibacterial effects were 96.5-100 for Ag-ACFs, 92.3-99.8 for Cu-ACFs and 95.5-100 for Ni-ACFs, respectivelylyvelylyly

Potency and plasma protein binding of drugs in vitro-a potentially misleading pair for predicting in vivo efficacious concentrations in humans

  • Yim, Dong-Seok
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.23 no.4
    • /
    • pp.231-236
    • /
    • 2019
  • In drug discovery or preclinical stages of development, potency parameters such as $IC_{50}$, $K_i$, or $K_d$ in vitro have been routinely used to predict the parameters of efficacious exposure (AUC, $C_{min}$, etc.) in humans. However, to our knowledge, the fundamental assumption that the potency in vitro is correlated with the efficacious concentration in vivo in humans has not been investigated extensively. Thus, the present review examined this assumption by comparing a wide range of published pharmacokinetic (PK) and potency data. If the drug potency in vitro and its in vivo effectiveness in humans are well correlated, the steady-state average unbound concentrations in humans [$C_{u_-ss.avg}=f_u{\cdot}F{\cdot}Dose/(CL{\cdot}{\tau})=f_u{\cdot}AUCss/{\tau}$] after treatment with approved dosage regimens should be higher than, or at least comparable to, the potency parameters assessed in vitro. We reviewed the ratios of $C_{u_-ss.avg}$/potency in vitro for a total of 54 drug entities (13 major therapeutic classes) using the dosage, PK, and in vitro potency reported in the published literature. For 54 drugs, the $C_{u_-ss.avg}$/in vitro potency ratios were < 1 for 38 (69%) and < 0.1 for 22 (34%) drugs. When the ratios were plotted against $f_u$ (unbound fraction), "ratio < 1" was predominant for drugs with high protein binding (90% of drugs with $f_u{\leq}5%$; i.e., 28 of 31 drugs). Thus, predicting the in vivo efficacious unbound concentrations in humans using only in vitro potency data and $f_u$ should be avoided, especially for molecules with high protein binding.

Effects of Preparation Conditions of $Y_1Ba_2Cu_3O_{7-y}$ Sintered with $Bi_2O_3$ on Superconductiog Properties ($Bi_2O_3$를 첨가하여 소결한 $Y_1Ba_2Cu_3O_{7-y}$ 초전도체의 제조 조건이 초전도 특성에 미치는 영향)

  • Kim, Shi-Yul;Park, Sung;Im, Ho-Bin
    • Electrical & Electronic Materials
    • /
    • v.3 no.2
    • /
    • pp.90-98
    • /
    • 1990
  • Y-Bi-Ba-Cu-O계 초전도체를 보통의 ceramic방법과 screen printing과 소결법으로 원판형과 후막형으로 제작하였다. B $i_{2}$ $O_{3}$를 첨가하여 소결한 $Y_{1}$B $a_{2}$C $u_{3}$ $O_{7-y}$의 초전도 성질은 전기저항측정과 자석위에 부상 유무로 조사하였다. 또한 B $i_{2}$ $O_{3}$를 첨가함에 따라 소결된 시편의 미세구조에 어떠한 영향을 주었는지 알아보았다. 전기저항 측정시 Yttrium 대신에 Bi로 부분적으로 치환한 경우인 $Y_{0.85}$B $i_{0.15}$B $a_{2}$C $u_{3}$ $O_{7-y}$의 상온 저항치가 기본조성인 $Y_{1}$B $a_{2}$C $u_{3}$ $O_{7-y}$의 그것보다 향상된 미세구조로 인해 더 작은 값을 나타낸다. 반면 $Y_{1}$B $a_{2}$C $u_{3}$ $O_{7-y}$에다가 초과로 B $i_{2}$ $O_{3}$를 첨가한 경우 오히려 미세구조는 불량하고 상온저항치도 더 높다. 이러한 사실은 입계에 잔류하는 이차상은 전기적 성질에는 크게 영향을 주나 자기적 성질에는 거의 영향을 주지않는 것으로 보인다. 후막으로 Y-Bi-Ba-Cu-O를 제작시 기판에 의해 좌우되는데 단지 magnesia 기판에서 소결시 bulk시편과 유사한 성질을 나타냈다.질을 나타냈다.다.

  • PDF

COPRA MEAL AS A SUPPLEMENT TO CATTLE OFFERED A LOW QUALITY NATIVE PASTURE HAY

  • Hennessy, D.W.;Kempton, T.J.;Williamson, P.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.2 no.2
    • /
    • pp.77-84
    • /
    • 1989
  • Twenty-four Hereford steers, 22 months old and a mean liveweight (${\pm}\;s.e.$) of $250\;{\pm}\;7\;kg$ were used in an experiment to evaluate over 42 days two rates of copra meal supplementation to cattle on a low N ($8.6\;{\pm}\;0.9$ g N/kg dry matter (DM)), low digestible ($45\;{\pm}\;5.2%$ DM) native pasture hay. Steers given the two rates (500, 1000 g/steer/day; i.e. 500C, 1000C) were compared to steers on a non-supplemental diet and to the effects on steers of supplemental urea (30g/steer/day; 30U) or with copra meal (500 g/steer/day; 500C.U), or of cottonseed meal (500 g/steer/day; 500S). Liveweight change was increased (P<0.01) by all of the supplements except by supplemental urea. The most effective treatment, 1000C, increased significantly (P<0.01) liveweight change (946 g/day) in steers above all supplements except those steers given 500C.U (718 g/day). Hay intake per unit liveweight was increased (P<0.05) by 7% by the 30U and 500C.U treatment, and by 9% by 500C; this group having the highest supplements, being greatest (P<0.05) for the 1000C group (6.0 g feed intake/g gain) and least for the 500S supplemented group (11.5 g/g gain). Efficiency was lowest (18.6 g/g gain) for the non-supplemented steers on the basal hay diet. Copra meal N was less degradable (i.e. 29%) in nylon bags over 15 hours in the rumen than was cottonseed meal N (37%), and rumen ammonia concentrations were lower (P<0.05) in cattle supplemented with copra meal (25, 27 mg N/L) than in cattle given urea (36 mg N/L) or cottonseed meal (39 mg N/L). It is concluded that copra meal at a daily rate of 500 g/head, and with rumen soluble nitrogen from urea, is an effective supplement for improving growth of cattle on a low quality forage.

A Comparative Study on bank's responsibilities in the Electronic Payment System -comparison between Korea and U.S.A- (국제 전자결제시스템에서 금융기관의 책임 및 정책적 시사점 -한국과 미국의 전자금융제도 비교-)

  • Lee, Byeong-Ryul
    • International Commerce and Information Review
    • /
    • v.12 no.1
    • /
    • pp.35-54
    • /
    • 2010
  • This article explored the bank's responsibilities in electronic payment system between Korea and U.S.A. In order to complete my research object, I used Article 4A of the U.C.C. and EFTA of 1978 and by Electronic Financial Transaction Act of Korea as a analytic instruments. I also adapted America's various regulations to regulate concerned parties(banks). The system of this article is going to display as fellows; First, I presented recent trend and legal stabilities of electronic payment in this article. Second, I focuses on the allocation of risk of loss caused by ambiguous term in payment orders that do not express the subjective intention of the senders. I also did analyze the solution procession of error occurring in course of send of payment order. Third, In any action which involves a customers's liability for an unauthorized electronic fund transfer, the burden of proof is upon the financial institution to show that the electronic fund transfer was authorized. Forth, Customers have to report the error and unauthorized electronic fund transfer after awaring of it. Then bank will be liable for such a unauthorized electronic fund transfer. But If customer's failure to report, the bank has exemptions. Lastly, In order to prevent or detect the unauthorized electronic fund transfer, bank will agree with custom to establish a commercially reasonable security procedure, while bank has duties to notify in order to decrease the loss resulted from unauthorized payment order in korea law.

  • PDF