• Title/Summary/Keyword: I-scan

Search Result 450, Processing Time 0.028 seconds

Clinical Observation of Perfusion Lung Scan with $^{131}IMAA$ and Ventilation tung Scan with $^{198}Au$ Colloid in various Lung Diseases (각종폐질환(各種肺疾患)에 있어서의 $^{131}I$표지대응집인혈청(標識大凝集賤集人血淸)알부민($^{131}I$-Macroaggregated Albumin)을 이용(利用)한 폐혈류(肺血流)스캐닝 및 교질상방사성금(膠質狀放射性金)-198($^{198}Au$ colloid)을 이용(利用)한 폐흡입(肺吸入)스캐닝에 관(關)한 고찰(考察))

  • Koh, C.S.;Rhee, C.H.;Hong, C.K.;Kim, D.J.
    • 대한핵의학회:학술대회논문집
    • /
    • 1967.11a
    • /
    • pp.104.2-104.2
    • /
    • 1967
  • PDF

Analysis of the Contact Pressure Distribution and Kinetics of Knee Implant Using the Simulator (Simulator를 이용한 인공무릎관절 접촉면의 압력분포 및 운동성 분석)

  • 이문규;김종민;김동민;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.363-367
    • /
    • 2003
  • Contact area and pressure are important factors which directly influence a life of knee implants. Since implant's mechanical functions should be experimentally evaluated for clinical use, many studies using a knee simulator and a pressure sensor system have been conducted. However it has not been reported that the contact pressure's distribution of a knee implant motion was estimated in real-time during a gate cycle. Therefore. the objective of this study was to analyze the contact pressure distribution for the motion of a joint using the knee simulator and I-scan sensor system. For this purpose, we developed a force-controlled dynamic knee simulator to evaluate the mechanical performance of artificial knee joint. This simulator includes a function of a soft tissue and has a 4-degree-of-freedom to represent an axial compressive load and a flexion angle. As axial compressive force and a flexion angle of the femoral component can be controlled by PC program. The pressure is also measured from I-scan system and simulator to visualize the pressure distribution on the joint contact surfaces under loading condition during walking cycle. The compressive loading curve was the major cause for the contact pressure distribution and its center move in a cycle as to a flexion angie. In conclusion, this system can be used to evaluate to the geometric interaction of femoral and tibial design due to a measured mechanical function such as a contact pressure, contact area and a motion of a loading center.

Management of Recurrent Thyroid Carcinoma with Negative Diagnostic Radioiodine Whole-Body Scan (진단적 방사성옥소 전신스캔이 음성인 갑상선 재발암의 진료)

  • Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.3
    • /
    • pp.117-124
    • /
    • 2001
  • Serum thyroglobulin measurement and I-131 whole-body scintigraphy (WBS) are well-established methods for the detection of recurrence in the follow-up of patients with thyroid carcinoma. However, inconsistent results are observed frequently, and these two methods are not always able to detect recurrence. In some patients, serum thyroglobulin level is elevated but the WBS is negative, because the recurrent tumor is too small and below the sensitivity of the diagnostic scan, or there is a dissociation between thyroglobulin synthesis and the iodine frapping mechanism. In such cases, various nuclear imaging methods including Tl-201 Tc-99m-sestamibi, and F-18-FDG PET can be used besides anatomical imaging methods. Among them, FDG PET localizes recurrent lesions in WBS-negative thyroid carcinoma with high accuracy. Several studies have suggested that empirical high-dose I-131 therapy resulted in a high rate of visualization in post-therapy scans with evidence of subsequent improvement. An important question is when to operate on patients with recurrent tumor. We believe that surgical removal is the best means of treatment for patients with localized persistent tumor, despite the high-dose I-131 therapy. with tumor in thyroid remnant, and with isolated recurrence in the lymph node, lung or bone. In addition, we recommend palliative resection of locally unresectable mass with subsequent treatment with high-dose I-131 therapy. Before I-131 therapy, the evaluation of sodium-iodide symporter expression in thyroid carcinoma can predict iodine uptake. Retinoic acid is known to induce redifferentiation, and to enhance I-131 uptake in thyroid carcinoma. Retinoic acid therapy may represent an alternative approach before high-dose I-131 therapy.

  • PDF

Thermal Imager Implementation Using Infrared Sensor (적외선 센서를 이용한 열상장비의 구현)

  • Yu, W.K.;Yoon, E.S.;Kim, C.W.;Song, I.S.;Hong, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1250-1254
    • /
    • 1992
  • This paper describes the designed and fabricated thermal imaging system with the SPRITE(Signal PRocessing in The Element) detector, operating in the 3-12 micron band. This system consists of an afocal telescope, a scan unit containing the SPRITE detector, an electronic processor unit and a cooler. The optical scan system utilizing rotating polygon and oscillating mirror, is 2-dimensional serial/parallel scan type using five elements of the detector. And the electronic processor unit performs digital scan conversion to reform the parallel data stream into serial analog data compatable with conventional RS-170 video. The scan field of view is 40 ${\times}$ 26.7 and the MRTD(Minium Resolvable Temperature Difference) is 0.6 K at 7.5 cycles/mm. The acquired thermal image indicates that this system has a satisfactory performance.

  • PDF

Phantom Study of the Mutual Influences Between 18F-FDG and 99mTcO4- on the Same Day (18F-FDG와 99mTcO4-를 이용한 당일 검사 시 상호 영향에 대한 Phantom 연구)

  • Ham, Jun Cheol;Park, Min Soo;Bahn, Young Kag;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.68-72
    • /
    • 2014
  • Purpose The nuclear medicine examination, there is a difficulty to carry out the inspection of both on the day of residual isotope due to the half-life. In this study, by studying the mutual influence and $^{18}F$-FDG of $^{99m}TcO_4{^-}$, I would like to explain the matters to be considered in the case of performing the same day. Materials and Methods With the NEMA-1994 Phantom, and experiments were performed 3 times. Create a 1: 4 Background ratio HOT and the $^{99m}TcO_4{^-}$ The first experiment: After underwent SPECT in INFINIA (GE Healthcare, MI, USA), and were injected with $^{18}F$-FDG 37 MBq in the Background area, 13 once for 60 minutes under the same conditions was time Scan. Create a 1: 4 Background ratio HOT and the $^{18}F$-FDG second is: The Scan in PET/CT Discovery 600 (GE Healthcare, MI, USA), and 148 MBq after injection $^{99m}TcO_4{^-}$ the Background area, once for 60 minutes, 6 under the same conditions was time Scan. Create a 1: 4 Background ratio HOT and the $^{18}F$-FDG experiments las, increments of 296 MBq and 148 MBq the 1 Bed Scan after $^{99m}TcO_4{^-}$, was 1 Bed Scan under the same conditions. Non BKG area and HOT, I was measured comparing the Total Counts and SNR or CNR. Results Showed a significant difference in the ratio CNR of enforcement during SPECT $^{18}F$-FDG is, (p>0.05). The $^{99m}TcO_4{^-}$ was no significant difference between the SNR ratio of PET / CT at the time of the effective date (p<0.05). I got the results $^{99m}TcO_4{^-}$ that reduce the Total Counts of PET / CT scan. Conclusion If you make a PET / CT scan, may affect the test using the $^{99m}TcO_4{^-}$ up to 12 hours, when it is performed before the $^{99m}TcO_4{^-}$, does not affect the SNR and SUV, PET / CT scan I reduced the detection efficiency. The inspection of day, we'd like to recommend a way to complement the detection efficiency to increase the inspection time of PET / CT in move forward the inspection using the $^{99m}TcO_4{^-}$.

  • PDF

The Significance of $^{99m}Technetium$ Dimercaptosuccinic Acid(DMSA) Scan as a Substitute for Voiding Cystourethrography(VCUG) in Evaluating Children with first Febrile Urinary Tract Infection (생애 첫 발열성 요로 감염 환아에 대한 평가에서 배뇨성 방광 요도 조영술을 대체하기 위한 검사로서 $^{99m}technetium$ dimercaptosuccinic acid(DMSA) scan의 의의)

  • Han, Seung-Beom;Ko, Yong-Min;Lee, Sue-Young;Jeong, Dae-Chul;Kang, Jin-Han;Lee, Kyung-Yeon;Uhm, Mee-Ryung;Kim, Woong-Heum;Kim, Jung-Sue
    • Childhood Kidney Diseases
    • /
    • v.11 no.2
    • /
    • pp.220-228
    • /
    • 2007
  • Purpose : We studied the value of clinical signs, laboratory findings and $^{99m}technetium$ dime-rcaptosuccinic acid(DMSA) scan in predicting the presence of vesicoureteral reflux(VUR) in children with first febrile urinary tract infection(UTI). Methods : A retrospective analysis of 84 hospitalized children with first febrile UTI was performed. They underwent DMSA scan and voiding cystourethrography(VCUG) during the acute phase, and were divided into three groups according to the results of the VCUG: absence of VUR, mild(grade I-II) and severe VUR(grade III-V). We studied the relation of VUR to age, gender, fever duration, causative organism, white blood cell count, serum C-reactive protein and result of DMSA scan. Results : Among 84 patients, 6 had mild and 17 had severe VUR. Thirty-eight had abnormal DMSA scan. results Patients with VUR were older than those without VUR(P<0.01). There was a lower probability of infection with Escherichia coli in patients with severe VUR than in those with mild and absent VUR(P<0.01). An abnormal DMSA scan correlated with the presence and severity of VUR(P<0.05). Severe VUR was present in 10.9% of patients with normal DMSA scan. The sensitivity, specificity, positive and negative predictive values of the DMSA scan in predicting the presence of VUR were 69.6%, 63.9%, 42.1%, and 84.8%, respectively. Conclusion : An abnormal DMSA scan correlated to the presence and severity of VUR, but the sensitivity, specificity and positive predictive value of the DMSA scan were low. There-fore, patient with an abnormal DMSA scan requires a VCUG. In order to prevent missing the 10.9% of patients with severe VUR but normal DMSA scans, a VCUG should be performed in patient with normal DMSA scan.

  • PDF

Evaluation of Therapeutic Effect with Serum Thyroglobulin and Whole Body Scan after 200mCi $^{131}I$ Treatment in Patients with Well-Differentiated Thyroid Carcinoma (전이성 분화 갑상선암에서 200mCi 방사성 옥소 치료효과 평가를 위한 혈청 Thyroglobulin 추적검사와 전신스캔의 의의)

  • Lee, Chang-Hee;Yoon, Jong-Kil;Jeong, Sang-Hoon;Kwu, Gyo-Seon;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Sung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.451-459
    • /
    • 1995
  • Thirty-eight patients with metastatic well-differentiated thyroid carcinoma treated with 200mCi $^{131}I$ were studied. There were false negative serum thyroglobulin values during TSH suppression or at anti-thyroglobulin antibody(+) and discrepancies between findings of whole body scan and serum thyroglobulin level. After one to five cycles of 200mCi $^{131}I$ therapy, complete remission and partial remission were achieved at 5.3% and 57.9%, respectively. We concluded that all of serum thyroglobulin, TSH, anti-thyroglobulin antibody, $^{131}I$ or $^{123}I$ whole body scan were necessary in follow up of metastatic well-differentiated thyroid carcinoma. Also, if there was no response after repetitive 200mCi $^{131}I$ therapy, higher doses of $^{131}I$ therapy should be considered.

  • PDF

Sialolithiasis Mimicking Metastatic Thyroid Cancer (갑상선암 전이병소로 오인된 타석증 증례)

  • Jeong, Hwan-Jeong;Bom, Hee-Seung;Song, Ho-Cheon;Min, Jung-Jun;Kim, Seung-Min;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.94-98
    • /
    • 2000
  • We report a false positive case of I-131 scan due to a sialolithiasis in right submandibular gland. I-131 images showed not only remnant thyroid tissues and functional metastases in the anterior neck but also a hot uptake near right submandibular gland. We confirmed the sialolithiasis by radiologic studies. Sialolithiasis should be regarded as a false positive cause when I-131 scan shows a hot spot near salivary bed.

  • PDF