• 제목/요약/키워드: I-scan

검색결과 451건 처리시간 0.03초

Prognostic Factors of Renal Scarring on Follow-up DMSA Scan in Children with Acute Pyelonephritis

  • Lee, Juyeen;Woo, Byung Woo;Kim, Hae Sook
    • Childhood Kidney Diseases
    • /
    • 제20권2호
    • /
    • pp.74-78
    • /
    • 2016
  • Purpose: Early diagnosis and treatment of urinary tract infection have been emphasized to prevent renal scarring. If untreated, acute pyelonephritis could cause renal injury, which leads to renal scarring, hypertension, proteinuria, and chronic renal failure. The purpose of this study was to assess risk factors of renal scarring after treatment of acute pyelonephritis (APN). Methods: The medical records of 59 patients admitted at Daegu Fatima Hospital because of APN between March 2008 and April 2015 whose renal cortical defects were confirmed by using initial technetium-99m dimercaptosuccinic acid (DMSA) scans were reviewed retrospectively. We divided 59 patients into 2 groups according to the presence of renal scar and assessed risk factors of renal scar, including sex, age at diagnosis, feeding method, hydronephrosis, bacterial species, vesicoureteral reflux, and vesicoureteral reflux grade. Results: Of 59 patients (41%), 24 showed renal scar on follow-up DMSA scan. No significant differences in sex, hydronephrosis, bacterial species, and fever duration were found between the renal-scarred and non-scarred groups. As for age at diagnosis, age of >12 months had 5.8 times higher incidence rate of renal scarring. Vesicoureteral reflux (VUR) affected renal scar formation. VUR grade III or IV had 14.7 times greater influence on renal scar formation than VUR grade I or II. Conclusion: Our data suggest that the presence of VUR and its grade and age at diagnosis are risk factors of renal scar on follow-up DMSA scan after APN.

A study on procedure for classifying male muscular lower body somatotype from general anthropometric database

  • Lee, Minji;Chun, Jongsuk
    • 복식문화연구
    • /
    • 제21권4호
    • /
    • pp.585-595
    • /
    • 2013
  • The most researches developing pattern of compression style sportswear were targeted at the live model that has muscular body build. The purpose of this study was developing a method for classifying men's lower body types in terms of muscular body build. The 3D human body scan data and body measurements of 30s of Size Korea were analyzed. The subjects (n=203) were men between the ages of 30 and 39 years. Men's muscular body build was classified with two key dimensions, thigh girth and calf girth. The subjects were divided into four groups. From each group, average subjects (n=42) whose height and weight were close to the mean value ($mean{\pm}1/2$ S.D.) were selected. 42 subjects were divided up as four groups. Group I (n=7) was thigh and calf developed body type. Group II (n=9) was thigh developed body type. Group III (n=11) was calf developed body type. Group IV (n=15) was thigh and calf undeveloped body type. Four groups had distinct different at widths (n=4), depths (n=4), and girths (n=9) dimensions. The results showed that the muscular men in their 30s could be defined by thigh and calf girths. The thigh developed muscular men had thigh girth over 60cm and the calf developed muscular men had calf girth over 38cm. From each group one representative was selected by 3D body scan figure.

복합 [$90^{\circ}-{\tau}-180^{\circ}-2{\tau}-180^{\circ}-{\tau}$ 시이퀸스를 이용한 핵자기 공명 혈관 조영술 (MR ANGIOGRAPHY USING THE COMPOSITE [$90^{\circ}-{\tau}-180^{\circ}-2{\tau}-180^{\circ}-{\tau}$] SEQUENCE)

  • 김재호;이기동;전현호;조장희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1989년도 춘계학술대회
    • /
    • pp.35-37
    • /
    • 1989
  • A new MR angiography technique using a composite sequence for the suppression of static sample signals is proposed and verified with experiments. When the composite [$90^{\circ}-{\tau}-180^{\circ}-2{\tau}-180^{\circ}-{\tau}$] sequence is applied, the large signal from the static sample is sufficiently suppressed but the signal from fresh inflow sample of which amplitude. is observed without suppression. These properties are appropriate for angiographic applications. In this paper, a modified line scan method (Block line scan angiography) incorporated with the composite [$90^{\circ}-{\tau}-180^{\circ}-2{\tau}-180^{\circ}-{\tau}$] sequence is used to obtain flow-only images, i.e., angiograms. The block line scan method improves the resolution in the flow-direction at the expense of imaging time. With the composite sequence, there is no need for subtraction procedure as in the most conventional angiographic methods. Experimental results for a phantom and a normal volunteer with KAIS 2.0 Tesla MRI system are shown.

  • PDF

기하학적 동적 외곽선 모델을 이용한 X-ray 단층촬영영상의 영상추출 (Segmentation of Computed Tomography using The Geometric Active Contour Model)

  • 장동표;김선일
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.541-545
    • /
    • 1997
  • This paper presents a modified geometric active contour model or edge detection and segmentation of computed tomography(CT) scan images. The method is based on the level setup approach developed by Osher and Sethian and the modeling of propagation fronts with curvature dependent speeds by Malladi. Based on above algorithms, the geometric active contour is obtained through a particular level set of hypersurface lowing along its gradient force and curvature force. This technique retains the attractive feature which is topological and geometric flexibility of the contour in recovering objects with complex shapes and unknown topologies. But there are limitations in this algorithm which are being not able to separate the object with weak difference from neighbor object. So we use speed limitation filter to overcome those problems. We apply a 2D model to various synthetic cases and the three cases of real CT scan images in order to segment objects with complicated shapes and topologies. From the results, the presented model confirms that it attracts very naturally and efficiently to the desired feature of CT scan images.

  • PDF

사이드 스캔 소나 기반 Pose-graph SLAM (Side Scan Sonar based Pose-graph SLAM)

  • 권대현;김주완;김문환;박호규;김태영;김아영
    • 로봇학회논문지
    • /
    • 제12권4호
    • /
    • pp.385-394
    • /
    • 2017
  • Side scanning sonar (SSS) provides valuable information for robot navigation. However using the side scanning sonar images in the navigation was not fully studied. In this paper, we use range data, and side scanning sonar images from UnderWater Simulator (UWSim) and propose measurement models in a feature based simultaneous localization and mapping (SLAM) framework. The range data is obtained by echosounder and sidescanning sonar images from side scan sonar module for UWSim. For the feature, we used the A-KAZE feature for the SSS image matching and adjusting the relative robot pose by SSS bundle adjustment (BA) with Ceres solver. We use BA for the loop closure constraint of pose-graph SLAM. We used the Incremental Smoothing and Mapping (iSAM) to optimize the graph. The optimized trajectory was compared against the dead reckoning (DR).

Prediction of Mammalian MicroRNA Targets - Comparative Genomics Approach with Longer 3' UTR Databases

  • Nam, Seungyoon;Kim, Young-Kook;Kim, Pora;Kim, V. Narry;Shin, Seokmin;Lee, Sanghyuk
    • Genomics & Informatics
    • /
    • 제3권3호
    • /
    • pp.53-62
    • /
    • 2005
  • MicroRNAs play an important role in regulating gene expression, but their target identification is a difficult task due to their short length and imperfect complementarity. Burge and coworkers developed a program called TargetScan that allowed imperfect complementarity and established a procedure favoring targets with multiple binding sites conserved in multiple organisms. We improved their algorithm in two major aspects - (i) using well-defined UTR (untranslated region) database, (ii) examining the extent of conservation inside the 3' UTR specifically. Average length in our UTR database, based on the ECgene annotation, is more than twice longer than the Ensembl. Then, TargetScan was used to identify putative binding sites. The extent of conservation varies significantly inside the 3' UTR. We used the 'tight' tracks in the UCSC genome browser to select the conserved binding sites in multiple species. By combining the longer 3' UTR data, TargetScan, and tightly conserved blocks of genomic DNA, we identified 107 putative target genes with multiple binding sites conserved in multiple species, of which 85 putative targets are novel.

Comparison of Avatar Posture Formation According to 3D Virtual Garment Modeling Programs -Focusing on Cycling Movements of High-School Male Cyclist-

  • Park, Hyunjeong;Do, Wolhee
    • 한국의류학회지
    • /
    • 제45권6호
    • /
    • pp.965-977
    • /
    • 2021
  • The study aimed to analyze the functional differences in 3D virtual garment programs and compare body scan data with the corresponding 3D virtual models. We selected 3D virtual garment programs, formed virtual models in a representative size for high-school male cyclists, and analyzed them using the Design-X program. The results were as follows. In the 3D virtual garment programs, the anthropometric items for virtual model forming differed significantly from the standard anthropometric items suggested by Size Korea. Comparing the lower body scan data and virtual models formed by the 3D virtual garment programs, the biggest difference was in the shapes of the waist and hips, i.e., the flatness values of the waist and hips were different for each program in the cross-section view. In the lower body, a data-input-based program was needed for changing the exact measurement position of the waist circumference and hips' shape in detail. If a 3D virtual garment program provides functions for the virtual model's joint angle input and free motion transformation, it is expected to be widely used in the sportswear industry.

레이저 직접 패터닝에 의한 폴리이미드의 표면 특성 제어 (Tailoring Surface Properties of Polyimides by Laser Direct Patterning)

  • 황윤찬;손정민;박재희;남기호
    • 한국염색가공학회지
    • /
    • 제35권2호
    • /
    • pp.121-127
    • /
    • 2023
  • In this study, a comprehensive investigation was conducted on the morphological and property changes of laser-induced nanocarbon (LINC) as a function of laser process parameters. LINC was formed on the surfaces of polyimide films with different backbone structures under various process conditions, including laser power, scan speed, and resolution. Three different forms of LINC electrodes (i.e., continuous 3D porous graphene, wooly nanocarbon fibers, line cut) were formed depending on the laser power and scan speed. Furthermore, heteroatom doping induced from the chemical structure of the polyimide during laser patterning was found to be effective in modifying the electrical properties of LINC electrodes. The LINC surfaces exhibited different microstructures depending on the laser beam resolution under constant laser power and scan speed, allowing for controllable surface wettability. The correlation between the chemical structure of the polymer substrate, laser process parameters, and carbonized surface properties in this study is expected to be utilized as fundamental understanding for the manufacturing of next-generation carbon-based electronic devices.

급성신우신염과 방광요관역류 환아에서 DMSA신주사의 추적관찰 (A Follow-up Study of DMSA Renal Scan in Children with . Acute Pyelonephritis and Vesicoureteral Reflux)

  • 오창희;최원규;김지홍;이재승;김병길
    • Childhood Kidney Diseases
    • /
    • 제2권2호
    • /
    • pp.145-151
    • /
    • 1998
  • 목 적 : 99m-TCDMSA(이하 DMSA)신주사는 발열성 요로감염환아 혹은 방광요관역류가 있는 환아에서 급성신우신염과 신반흔을 평가하는데 유용한 검사로 알려져 있다. 저자들은 이를 해석하는데 있어서 정확성을 기하고 효율적인 이용을 위해서 본 연구를 시행하였다. 방 법 : 1992년 1월부터 1995년 6월까지 연세대학교 세브란스병원에 내원하여 발열, 측복부 동통, 농뇨 등의 요로감염 증세 혹은 요 배양검사상 세균이 $10^5/mL$이상 동정된 환아 155명을 대상으로 DMSA신주사, 신초음파 및 배뇨성 요도방광조영술을 시행하였으며, 이중 방광요관역류가 없으면서 DMSA신주사에서 이상 소견을 보인 환아는 29명, 방광요관역류가 있었던 환아는 32명이 있었다. 초기 DMSA신주사상 병변이 발견되었던 환아는 추적검사를 통해 병변의 변화를 조사하였으며, 방광요관역류가 있었던 환아는 역류 정도에 따라 DMSA 신주사 및 신초음파 소견을 분석하였다. 결 과 : 방광요관역류 없이 DMSA신주사상 비정상소견을 보였던 29명의 환아는 요로감염 증상이 시작된 지 평균 $7.5{\pm}4.8$일내에 DMSA신주사를 시행하였으며, 평균 $0.99{\pm}0.46$개월에 추적 검사를 실시한 결과 21명 ($72.4\%$)에서는 정상으로 되었고, 3명($10.3\%$)은 병변이 감소하였으며, 5명($17.3\%$)은 병변이 지속되었다. 병변이 남아있는 8명을 3개월내 DMSA신주사를 시행한 결과 2명에서만 병변이 남아있었다. DMSA신주사로 급성신우신염이 확인된 29명중 12명($41.4\%$)이 신초음파에서 이상소견을 보였다. 방광요관역류가 있었던 32명(53역류신장)은 역류정도에따라 Grade $I:25.0\%,\;II:44.5\%,\;III:64.3\%,;IV:92.9\%,\;V:100\%$에서 초기 DMSA 신주사상 이상소견을 보였다. 53역류신장중 전체적으로 DMSA신주사에서 36신장($68.0\%$), 신초음파에서 26신장($49.1\%$)이 이상소견을 보여 유의한 차이를 보였으며(P<0.05). 특히 Grade IV 역류신장에서 유의한 차이가 있었다(P<0.05). 결 론 : DMSA신주사를 이용한 급성신우신염의 진단은 신초음파검사 보다 유용하며, 초기 DMSA신주사 소견상 이상소견을 보인 경우 약 8-12주 후 추적검사를 시행하여 변화를 관찰하고 섭취결손 부분이 남아있는 경우에는 향후 새로운 병소의 출현 혹은 정상화 여부를 보기 위한 추적검사가 필요하리라 사료된다. 방광요관역류 환아에서 DMSA신주사소견은 방광요관역류의 정도가 심할수록 이상소견을 보일 확률이 높으며 신초음파 검사보다 민감도가 높은 것을 알 수 있었다.

  • PDF

인두암과 식도암의 새로운 진단내시경 (New Diagnostic Techniques in Cancer of the Pharynx and Esophagus)

  • 조주영;조원영
    • 대한기관식도과학회지
    • /
    • 제17권1호
    • /
    • pp.14-18
    • /
    • 2011
  • The diagnosis and treatment of early gastrointestinal cancers is the gastroenterologists' mission because of national cancer screening program in South Korea. The detection of early cancers is emphasized, because these were previously treated with surgical treatment can be currently cured with endoscopic treatment. Gastroenterologists who achieved at least on some level can make an exact diagnosis regardless of what type of endoscopy, but generally, there are some required conditions for an optimal diagnosis. First, clinically important lesions have to be detected easily. Second, the border and morphology of lesions have to be characterized easily. Third, lesions have to be diagnosed exactly. Precancers and early cancers are often subtle and can pose a challenge to gastroenterologists to visualize using standard white light endoscopy. The use of dye solutions aids the diagnosis of early gastrointestinal cancers, however, it is a quite cumbersome to use dye solutions all the time and the solution often bothers the exact observation by pooling into the depression or ulceration of the lesion. To overcome this weakness, newer endoscopes are now developed so called "image enhanced endoscopy" using optical and/or electronic methods such as narrow band imaging (NBI), autofluorescence imaging (AFI), i-scan, flexible spectral imaging color enhancement (FICE) and confocal endomicroscopy (CLE).

  • PDF