• Title/Summary/Keyword: I-method

Search Result 17,532, Processing Time 0.048 seconds

Analysis of Resistance Performance of a Ship having a Large Attitude based on CFD (CFD에 의한 자세변화가 큰 선박의 저항성능 해석)

  • Kim, Hyun-Soo;Park, Dong-Woo;Yang, Young-Jun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.7
    • /
    • pp.961-967
    • /
    • 2019
  • This research presents an efficient method based on computational fluid dynamics (CFD) for estimating the resistance performance of a ship with a large settlement amount and a dynamic trim. The settlement of the inviscid flow analysis and the results of dynamic trim were used to set a large attitude for the ship prior to performing a viscous flow analysis; a viscous flow analysis was subsequently performed by Dynamic Fluid Body Interaction (DFBI). This method is termed as method I, in which a simple grating system can be used without employing the overset mesh technique by setting many attitudes before interpretation. Thus, method I is advantageous in reducing calculation time and improving calculation accuracy. The viscous flow analysis was performed using a commercial CFD code STAR-CCM+. Compared with the final convergence result, the first viscous flow analysis result of method I exhibited a variation of less than 1 % of resistance. The result was obtained by changing the gratings each time an attitude is changed at each calculation stage, based on the DFBI method provided to STAR-CCM+ using a simple grating system, which is not a superposed grating. This method is termed as method II. Compared with method II of resistance, method I exhibited a dif erence of 0.03-0.6 % for linear velocity. The results of method I were confirmed to be qualitatively and quantitatively appropriate through comparison with several trillion simulations.

Project Risk Management & Observational Method for soft ground improvement (연약지반을 대상으로 한 프로젝트 리스크와 현장계측의 과제와 대책)

  • Imanishi, Hajime
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.509-514
    • /
    • 2006
  • Considering the risk management, there are many examples and various studies for the corporation risk. However, I have never seen the project risk management that applied a construction site for practical approach. Therefore, I have developed a chart (I-Chart) for the project risk management, and also built a model (I-Chart scenario analysis) that I could use. I applied this model to container yard reclaimed land in harbor construction with approaching of geotechnical engineering.

  • PDF

Novel allocation method of tiles in Subchannel for I/Q imbalances Estimation in WiBro uplink (WiBro 상량링크에서 I/Q 불균형 성분을 추정하기 위한 새로운 부채널 할당 방식)

  • Kim, Hye-Jin;Jin, Young-Hwan;Ahn, Jae-Min
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.11A
    • /
    • pp.1146-1153
    • /
    • 2007
  • In this paper, we analyze the I/Q imbalances effects at the WiBro uplimk when using direct-conversion RF transceiver. If I/Q imbalance exists, the transmit signal is spread over two sbcarriers. As a result, phenomenon of performance reducing is produced. Contrary to OFDM system in which one user uses all subcarrier, symmetrical two subcarriers are assigned other users in OFDMA system. I/Q imbalances elements can't be estimated such a conventional allocation method of tiles in subchannel and compensated. In order to solve the problem, We propose a new method in order that symmetrical two subcarriers are assigned one user. If novel method is applied, we can estimate I/Q imbalances and compensate distortion received signal. As a result, we can obtain a performance similar performance when I/Q imbalances is not existed. Also, if proper detection methods are used, we get the effect of performance improvement, because of diversity gain what is happened due to combining I/Q imbalances with multi path fading channel.

Effect of Rainfall-Patterns on Slope Stability in Unsaturated Weathered Soils (강우사상의 영향을 고려한 불포화 풍화사면의 안정성)

  • Kim, Byeong-Su;Park, Seong-Wann
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.1027-1035
    • /
    • 2013
  • In this study, two rainfall patterns are utilized for practical consideration of rainfall phenomena in unsaturated soil slope design. One is the I.D.F (Intensity-Duration-Frequency) method which is an existing design rainfall method and ignores the effect of the variation of the rainfall according to the time. The other is the Huff method which considers this effect oppositely. First, the safety of factor of the slope according to the variation of an initial suction which means the precedent rainfall effect was examined by means of the application of the I.D.F method. Through the application of two rainfall patterns, it was discussed how the rainfall pattern affects the factor of safety of the slope. As a result, it is found that the Huff method is more practical on the evaluation of the slope stability than the I.D.F method.

A Novel Compensation Scheme for I/Q Mismatch in an OFDM Direct-Conversion Architecture (OFDM 전송방식 기반의 Direct-Conversion 수신기에서 I/Q 불균형 보상을 위한 새로운 방법 제안)

  • Bae, Jung-Hwa;Park, Jin-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.12C
    • /
    • pp.1265-1272
    • /
    • 2006
  • This paper proposes a compensation method that can alleviate the problem of I/Q mismatch generated in the direct-conversion receiver of OFDM systems. In the proposed method, the amount of I/Q mismatch is estimated using null-carriers in transmitted signals, and it is subtracted from received symbols to suppress I/Q mismatch effects. Simulations show experiments that the proposed method can effectively eliminate the I/Q mismatch effects.

Quad-rotor's stabilization control with Fuzzy + I method

  • Shin, Heon-Soo;Choe, Jeong-Yeon;Jeong, Gyeong-Gwon;Kim, Ju-Ung;O, Jeong-Hun;Eom, Ki-Hwan
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1127-1128
    • /
    • 2008
  • In this paper, we propose a control method to improve control performance for a Quad-rotor Unmanned Aerial Vehicle's stabilization. The proposed method is the Fuzzy+I control that contains a fuzzy controller which processes signals from the error and the change of error, and generates the control signal by summing up fuzzy output signal and integral signal. We simulated and experimented on the fuzzy+I control method by implementing Quad-rotor UAV that is able to hovering, for the purpose of verifying the effectiveness of the proposed fuzzy+I control method in comparison with general PID control, and we found out that fuzzy+I controller improved control performance of the system.

  • PDF

Method of the known cross sections for calibration of the fast neutron spectrometer with a single-crystal stilbene based detector

  • I.V. Urupa;E.V. Ryabeva;R.F. Ibragimov;V.D. Sapozhnikov
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3602-3607
    • /
    • 2024
  • The present work is devoted to implementation of the stilbene-based neutron spectrometer energy calibration method. The results of experiments with portable neutron generators and 238PuBe source and scattering materials with known cross sections are used for this method. It is shown that the submitted method makes it possible to carry out fast neutron spectrometry in the energy range from 1 to 15 MeV with the uncertainty of the unfolded neutron energy no more than 200 keV. Neutron spectra unfolding was carried out based on the measured spectra and a Geant4 simulated response matrix. Unfolded spectra were compared with the literature data and reference spectra.

Analysis on the result of I/I calculation by the exiting method and the standardized maual method (하수관거 I/I(침입수/유입수) 분석방법에 따른 산정 결과 비교 -기존 보정방법과 환경부 표준 매뉴얼에 의한 방법-)

  • An, Byung-Mo;Song, Ho-Myun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.213-221
    • /
    • 2011
  • The purpose of sewer system is to separate rain water from sewage water. Through this, it is possible to prevent the flood and preserve public water territory. For the past few years, many problems of the sewer system have been solved by the execution of sewer rehabilitation project. However, they still exist in sewer system caused by I/I, which are divided into infiltration and inflow. Infiltration means the rain water and underground water that infiltrate through breakage point on pipes, inflow means the water that flows in through misconnection on pipes. This study shows how the I/I calculation has changed according to the new standardized manual and identifies the I/I difference between the new calculation and the existing one. Through the analysis on the two calculation methods we examined the appropriacy of the new method by comparing it to the old one. The result points out that the new standardized manual is more appropriate than the old in aspect of objectivity and reproducibility(establish standardization), rationality(alteration of inflow unit).

Characterizations of Pt-SPE Electrocatalysts Prepared by an Impregnation-Reduction Method for Water Electrolysis (함침-환원법으로 제조된 수전해용 Pt-SPE 전극촉매의 특성)

  • Jang, Doo-Young;Jang, In-Young;Kweon, Oh-Hwan;Kim, Kyoung-Eon;Hwang, Gab-Jin;Kang, An-Soo
    • Journal of Hydrogen and New Energy
    • /
    • v.17 no.4
    • /
    • pp.440-447
    • /
    • 2006
  • Solid polymer electrolyte(SPE) membrane with electrodes embedded on both faces offer unique possibilities for the electrochemical cells like water electrolyzer with fuel cell. The Nafion 117 membrane was used as the SPE, and $Pt(NH_3)_4Cl_2$ and $NaBH_4$ as the electrocatalysts and reducing agent, respectively. The 'impregnation-reduction(I-R) method' has been investigated as a tool for the preparation of electrocatalysts for water electrolyzer by varying the concentration of reducing agent and reduction time at fixed concentration of platinum salt, 5 mmol/L. Pt-SPE electrocatalysts prepared by non-equilibrium I-R method showed the lowest cell voltage of 2.17 V at reduction time, 90 min and with concentration of reducing agent 0.8 mol/L and the cell voltage with those by equilibrium I-R method was 2.42 V at reduction time, 60 min and with concentration of reducing agent 0.8 mol/L. The cell voltage were obtained at a current density $1\;A/cm^2$ and $80^{\circ}C$. In water electrolysis, hydrogen production efficiency by Pt-SPE electrocatalyst is 68.2% in case of non-equilibrium I-R method and 61.2% at equilibrium I-R method.

Measurements of the Vibrational Power Flow in Structure Beam by Using the Structural Intensity Method (Structural Intensity 법을 이용한 구조체의 진동전달량 측정)

  • ;Tichy, Jiri
    • Journal of KSNVE
    • /
    • v.4 no.2
    • /
    • pp.231-238
    • /
    • 1994
  • This paper presents an experimental method to find the vibrational transmission characteristics of structures by using the structural intensity method which is used as the important techniques of active vibration control method. Experimental results are obtained from measurements performed on a structure beam by 2, 3 and 4 position linear accelerometr array (2, 3 and 4 structural intensity : 2, 3 and 4 S.I.) methods at near and farfield conditions. These results are compared with the measurement values of conventional power flow measurement method called input power measurement in order to verify the accuracy of structural intensity methods. To minimize the errors associated with 2, 3 and 4 S.I. methods, the measurement locations were selected by the result of modal analysis and the averaged data by the inter-change of accelerometer array was utilized. In 3 and 4 S.I. methods measured wavenumber instead of theoretical wavenumber was used. This paper shows that measurements of bending wave power flow by using 2, 3 and 4 S.I. methods can give accurate values under general field conditions in structural beam and the accuracy of 2, 3 S.I. methods is higher than 4 S.I. methods. Finally, 2 position linear accelerometer array method is suggested as the practical structural intensity technique.

  • PDF