• Title/Summary/Keyword: I-CAD

Search Result 294, Processing Time 0.03 seconds

White & Pink Esthetic for Clinical Restoration (심미보철 제작에 필요한 White & Pink Esthetic)

  • Yoo, Ha-Seong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.28 no.2
    • /
    • pp.95-115
    • /
    • 2019
  • To be successful in aesthetic prosthetic treatment, the crown part aesthetic (White Esthetic) and the tissue part aesthetic (Pink Esthetic) must be well controlled. Clinically, white esthetics are the area of dental technicians and pink esthetics are the area of dentists, but a deeper understanding of counterparts can produce more successful results. In this paper, I will briefly describe this process.

Material Information Extraction for Plate Parts Using Solid Models (솔리드 모델을 이용한 판재 부품의 소재 정보 추출)

  • Kim, Y.I.;Jun, C.S.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.11 no.5
    • /
    • pp.344-350
    • /
    • 2006
  • A method for extracting material information on sheet metal parts from an assembly model is proposed. In order to estimate the cost and order the required sheet metals, their outline profiles, thicknesses, quantities, and etc. are needed. The proposed method consists of two steps: First, sheet metal parts are selected through a feature recognition process from an assembly model. Then, some geometric information for the parts is calculated. In the later step a flattening process of bent parts is included. The method is implemented on a commercial CAD/CAM system Unigraphics with API routines and applied to steam turbine generators and large scale boilers.

Preference for Color and Fabric Motifs in Men's Clothing Design - In the area of men by age, physical type and job - (추동용 정장양복과 콤비양복의 색채 및 직물무늬에 관한 연구 - 성인남성의 연령별, 신체적 조건 및 직업에 따른 선호를 중심으로 -)

  • 조진숙
    • Journal of the Korean Home Economics Association
    • /
    • v.31 no.1
    • /
    • pp.193-210
    • /
    • 1993
  • The purpose of this study was to investigate the effect of age, physical type and job on preference for color and fabric motifs in men's clothing design. Color preference measures consisted of clothing styles painted in CAD. Preference for fabric motifs was assesed by stripe fabrics in size, width and strength. All of the preference measures were devised specifically for this study. Furthermore, items on Hight and Weight for physical type, age and job of subjects were included I the questionnaire. Data were obtained by self-administered questionnaires form 243 men (25-54 years old) in Seoul. Analysis was by chi-square (X2), frequency, and percentage. The results obtained in this study were as follows : 1. Color preference was not affected by age and physical type, Job was related to coordinate color of men's clothing. 2. Preference for width of striped motifs was affected by age and job. 3. Preference for strength of fabric motifs in men's jacket was affected by physical type.

  • PDF

QUANTITATIVE ANALYSES USING 4D MODELS - AN EXPLORATIVE STUDY

  • Rogier Jongeling;Jonghoon Kim;Claudio Mourgues;Martin Fischer;Thomas Olofsson
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.830-835
    • /
    • 2005
  • 4D models help construction planners to develop and evaluate construction plans. However, current analyses using 4D models are mainly visual and limit the quantitative comparison of construction alternatives. This paper explores the usefulness of extracting quantitative information from 4D models to support time-space analyses. We use two 4D models of an industry test case to illustrate how to analyze 4D content quantitatively (i.e., work space areas and distances between concurrent activities). This paper shows how these two types of 4D content can be extracted from 4D models to support 4D-based-analysis and novel presentation of construction planning information. We suggest further research to formalize the content of 4D models to enable comparative quantitative analyses of construction planning alternatives. Formalized 4D content will enable the development of reasoning mechanisms that automate 4D-model-based analyses and provide the information content for informative presentations of construction planning information.

  • PDF

Automated initial process planning system for three-axis NC machining of sculptured surfaces (자유 곡면의 3축 NC 가공을 위한 초기 공정 계획 기능의 자동화)

  • Kang, Jae-Kwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.3
    • /
    • pp.114-121
    • /
    • 1997
  • In this paper, the automated initial process planning for 3-axis NC machining of sculptured surfaces is persented. The solution algorithms determining three process planning functions, i.e. machining feasibility, setup orientation and feasible machine selection are developed. The machining feasibility is determined by means of BSM(Binary Spherical Map) which derives its solution quickly in algebraic form, and the setup orientation is determined so that the cutting force is minimized. Finally, the feasible machine is determined by computing the minimum motion ranges of each control axisl. The developed algorithms are tested by numerical simulations, convincing they can by readily implemented on the CAD/CAM system as a process planner.

  • PDF

Restoration of implant-supported fixed dental prosthesis using the automatic abutment superimposition function of the intraoral scanner in partially edentulous patients (부분무치악 환자에서 구강스캐너의 지대주 자동중첩기능을 이용한 임플란트 고정성 보철물 수복 증례)

  • Park, Keun-Woo;Park, Ji-Man;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.79-87
    • /
    • 2021
  • The digital workflow of optical impressions by the intraoral scanner and CADCAM manufacture of dental prostheses is actively developing. The complex process of traditional impression taking, definite cast fabrication, wax pattern making, and casting has been shortened, and the number of patient's visits can also be reduced. Advances in intraoral scanner technology have increased the precision and accuracy of optical impression, and its indication is progressively widened toward the long span fixed dental prosthesis. This case report describes the long span implant case, and the operator fully utilized digital workflow such as computer-guided implant surgical template and CAD-CAM produced restoration after the digital impression. The provisional restoration and customized abutments were prepared with the optical impression taken on the same day of implant surgery. Moreover, the final prosthesis was fabricated with the digital scan while utilizing the same customized abutment from the provisional restoration. During the data acquisition step, stl data of customized abutments, previously scanned at the time of provisional restoration delivery, were imported and automatically aligned with digital impression data using an 'A.I. abutment matching algorithm' the intraoral scanner software. By using this algorithm, it was possible to obtain the subgingival margin without the gingival retraction or abutment removal. Using the digital intraoral scanner's advanced functions, the operator could shorten the total treatment time. So that both the patient and the clinician could experience convenient and effective treatment, and it was possible to manufacture a prosthesis with predictability.

Construction of Sea-Floor Topographic Survey System Based on Echosounder and GNSS (Echosounder와 GNSS 기반 해저지형측량시스템의 구축)

  • Jin-Duk LEE;Yong-Jin CHOI;Jae-Bin LEE
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.1
    • /
    • pp.56-68
    • /
    • 2023
  • A system that extracts seabed topographic information by simultaneously and continuously observing the horizontal position and water depth in the sea by combining a single beam echosounder and GNSS was constructed. By applying the developed system to actual measurements of small-scale sea areas, the effectiveness of bathymetry and sea-floor topographic data acquisition using GNSS and echosounder was examined. By using the developed outdoor program DS-NAV and indoor program DS-CAD and applying the tide level data at the time of actual measurement of the target sea area, it was possible to derive bathymetry results based on the datum level i.e. approximate lowest low water level(A.L.L.W). By using the developed outdoor program DS-NAV and indoor program DS-CAD and applying the tide level data at the time of actual measurement of the target sea area, it was possible to derive the results of bathymetric survey based on the datum level. From database built through the actual measurement. it was possible to create 3D model of the sea-floor topography and extract cross-sections. The results of this study are expected to be economically useful for extracting seabed topographical information from small sea areas or in dredging sites for offshore construction.

Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report (구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례)

  • Yang, Sang-Hyun;Kim, Kyoung-A;Kim, Ja-Yeong;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.207-214
    • /
    • 2015
  • Due to the limitations of conventional removable partial denture prostheses to treat a cleft lip & palate patient who shows scar tissue on upper lip, excessive absorption of the maxillary residual alveolar ridge, and class III malocclusion with narrow palate and undergrowth of the maxilla, 4 implants were placed on the maxillary edentulous region and a maxillary removable implant-supported partial denture was planned using a CAD/CAM milled titanium bar. Unlike metal or gold casting technique which has shrinkage after the molding, CAD/CAM milled titanium bar is highly-precise, economical and lightweight. In practice, however, it is very hard to obtain accurate friction-fit from the milled bar and reduction in retention can occur due to repetitive insertion and removal of the denture. Various auxiliary retention systems (e.g. $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ attachment), in order to deal with these problems, can be used to obtain additional retention, cost-effectiveness and ease of replacement. Out of diverse auxiliary attachments, $Locator^{(R)}$ has characteristics that are dual retentive, minimal in vertical height and convenient of attachment replacement. Drill and tapping method is simple and the replacement of the metal female part of $Locator^{(R)}$ attachment is convenient. In this case, the $Locator^{(R)}$ attachment is connected to the milled titanium bar fabricated by CAD/CAM, using the drill and tapping technique. Afterward, screw holes were formed and 3 $Locator^{(R)}$ attachments were secured with 20 Ncm holding force for additional retention. Following this procedure, satisfactory results were obtained in terms of aesthetic facial form, masticatory function and denture retention, and I hereby report this case.

Influence of crown-to-implant ratio of short vs long implants on implant stability and marginal bone loss in the mandibular single molar implant (하악 구치 단일임플란트 수복에서 임플란트 길이에 따른 치관-임플란트 비율이 임플란트안정성 및 변연골소실에 주는 영향)

  • Baek, Yeon-Wha;Kim, Bongju;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.280-289
    • /
    • 2018
  • Purpose: The purpose of this randomized clinical trial is to determine whether implant length and the crown-to-implant (C/I) ratio influence implant stability and peri-implant marginal bone loss (MBL). Materials and Methods: 46 patients with single tooth missing in the posterior molar region of the mandible were included in this study. 19 implants (CMI IS-III $active^{(R)}$ long implant) of 5.0 mm diameter and 10 mm length were installed for the control group, while 27 implants (CMI IS-III $active^{(R)}$ short implant) of 5.5 mm diameter and 6.6, 7.3 or 8.5 mm length were placed for the experimental group. Each implant was inserted and immediately loaded using the digitally pre-fabricated surgical template and provisional restoration. The CAD-CAM monolithic zirconia crown was fabricated at 3 months after the surgery as a definitive restoration. The ISQ value and the MBL was measured at 48 weeks after the surgery. The correlation between the C/I ratio, MBL, and secondary implant stability was analyzed. Results: Successful results in terms of ISQ and MBL were achieved with both groups. There was no significant difference between the groups in terms of ISQ values and MBL at 48 weeks after the surgery (P > 0.05). No significant correlation was found between the C/I ratio and secondary stability as well as the C/I ratio and the MBL (P > 0.05). Conclusion: The influence of C/I ratio in both groups was not shown on the stability nor the marginal bone loss in implants supporting single crown of the mandible. Short implant could be a preferable alternative option in the reduced bone height mandible under the limited condition despite its higher C/I ratio.

A new method to measure the accuracy of intraoral scanners along the complete dental arch: A pilot study

  • Iturrate, Mikel;Lizundia, Erlantz;Amezua, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.331-340
    • /
    • 2019
  • PURPOSE. The purpose of this study is to assess the accuracy of three intraoral scanners along the complete dental arch and evaluate the feasibility of the assessment methodology for further in vivo analysis. MATERIALS AND METHODS. A specific measurement pattern was fabricated and measured using a coordinate measuring machine for the assessment of control distances and angles. Afterwards, the pattern was placed and fixed in replica of an upper jaw for their subsequent scans (10 times) using 3 intraoral scanners, namely iTero Element1, Trios 3, and True Definition. 4 reference distances and 5 angles were measured and compared with the controls. Trueness and precision were assessed for each IOS: trueness, as the deviation of the measures from the control ones, while precision, as the dispersion of measurements in each reference parameter. These measurements were carried out using software for analyzing 3-dimensional data. Data analysis software was used for statistical and measurements analysis (α=.05). RESULTS. Significant differences (P<.05) were found depending on the intraoral scanner used. Best trueness values were achieved with iTero Element1 (mean from 10 ± 7 ㎛ to 91 ± 63 ㎛) while the worst values were obtained with Trios3 (mean from 42 ± 23 ㎛ to 174 ± 77 ㎛). Trueness analysis in angle measurements, as well as precision analysis, did not show conclusive results. CONCLUSION. iTero Element1 was more accurate than the current versions of Trios3 and True Definition. Importantly, the proposed methodology is considered reliable for analyzing accuracy in any dental arch length and valid for assessing both trueness and precision in an in vivo study.