GFRs Measured by Gates' Method According to 5 Background Sites: Comparison with GFR Measured by I-125-Iothalamate Method (다양한 배후 방사능 설정에 따른 Cates 법 사구체 여과율의 차이: I-125-Iothalamate 측정법과의 비교)

  • Jung, Hyun-Seok;Chung, Yong-An;Kim, Sung-Hoon;Kim, Chung-Ho;Lee, Sung-Young;Sohn, Hyung-Seon;Baik, Jun-Hyun;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.306-310
    • /
    • 2004
  • Purpose: The aim was to assess how the background site affects the Gates' glomerular filtration rate(GFR) measurement using Tc-99m-DTPA in correlation with GFR by I-125-lothalamate method. Material and methods: The study populations were 63 adults with 39 men and 24 women aged from 20 to 59 yrs (mean=37.9 yrs). The fellowing five background regions of interest were used in measurement of GFR using Gates' method: 1) lower side of each kidney(subrenal), 2) around each kidney(circumferential), 3) upper side of each kidney(suprarenal), 4) lateral side of each kidney(lateral), 5) between the two kidneys(inter-renal). We also measured GFR using I-125-iothalamate in each subject. The two studies were separated by 1 to 3 weeks. The subjects were divided into two groups by renal depth. Group 1 with renal $depth{\geq}7cm$ and group 2 with renal depth<7cm. We calculated the means and standard deviations of the GFRs measured by two studies. And we statistically analyzed the correlation and differences among GFRs by Gates' method and the GFR by iothalamate method with correlation analysis. Results: The GFRs by Gates' method using suprarenal and inter-renal background correction showed better correlation with the GFR measured by I-125-iothalamate. And GFRs measured by Gates' method showed statistically significant correlation with the GFR measured by I-125-iothalamate in the group with renal depth<7cm. But GFRs measured by Gates' method did not show statistically significant correlation with the GFR measured by I-125-iothalamate in the group with renal $depth{\geq}7cm$. Conclusion: GFRs measured with Gates' method showed higher correlation with the GFR measured by I-125-iothalamate when the regions of interest were plated over the suprarenal and inter-renal backgrounds. And GFRs measured with Gates method showed statistically significant correlation with the GFR measured by I-125-iothalamate in the group with renal depth<7cm.

Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results (두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과)

  • Jeong, Myung-Hwan;Choi, Yong;Chung, Yong-Hyun;Song, Tae-Yong;Jung, Jin-Ho;Hong, Key-Jo;Min, Byung-Jun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • Purpose: The purpose of this study was to develop a small animal PET using dual layer phoswich detector to minimize parallax error that degrades spatial resolution at the outer part of field-of-view (FOV). Materials and Methods: A simulation tool GATE (Geant4 Application for Tomographic Emission) was used to derive optimal parameters of small PET, and PET was developed employing the parameters. Lutetium Oxyorthosilicate (LSO) and Lutetium-Yttrium Aluminate-Perovskite(LuYAP) was used to construct dual layer phoswitch crystal. $8{\times}8$ arrays of LSO and LuYAP pixels, $2mm{\times}2mm{\times}8mm$ in size, were coupled to a 64-channel position sensitive photomultiplier tube. The system consisted of 16 detector modules arranged to one ring configuration (ring inner diameter 10 cm, FOV of 8 cm). The data from phoswich detector modules were fed into an ADC board in the data acquisition and preprocessing PC via sockets, decoder block, FPGA board, and bus board. These were linked to the master PC that stored the events data on hard disk. Results: In a preliminary test of the system, reconstructed images were obtained by using a pair of detectors and sensitivity and spatial resolution were measured. Spatial resolution was 2.3 mm FWHM and sensitivity was 10.9 $cps/{\mu}Ci$ at the center of FOV. Conclusion: The radioactivity distribution patterns were accurately represented in sinograms and images obtained by PET with a pair of detectors. These preliminary results indicate that it is promising to develop a high performance small animal PET.