• Title/Summary/Keyword: I/V/T curve

Search Result 61, Processing Time 0.025 seconds

PLASMA POLYMERIZED THIN FILMS GROWN BY PECVD METHOD AND COMPARISON OF THEIR ELECTROCHEMICAL PROPERTIES

  • I.S. Bae;S.H. Cho;Park, Z. T.;Kim, J.G.;B. Y. Hong;J.H. Boo
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.119-119
    • /
    • 2003
  • Plasma polymerized organic thin films were deposited on Si(100) glass and Copper substrates at 25 ∼ 100 $^{\circ}C$ using cyclohexane and ethylcyclohexane precursors by PECVD method. In order to compare physical and electrochemical properties of the as-grown thin films, the effects of the RF plasma power in the range of 20∼50 W and deposition temperature on both corrosion protection efficiency and physical properties were studied. We found that the corrosion protection efficiency (P$\_$k/), which is one of the important factors for corrosion protection in the interlayer dielectrics of microelectronic devices application, was increased with increasing RF power. The highest P$\_$k/ value of plasma polymerized ethylcyclohexane film (92.1% at 50 W) was higher than that of the plasma polymerized cyclohexane film (85.26% at 50 W), indicating inhibition of oxygen reduction. Impedance analyzer was utilized for the determination of I-V curve for leakage current density and C-V for dielectric constants. To obtain C-V curve, we used a MIM structure of metal(Al)-insulator(plasma polymerized thin film)-metal(Pt) structure. Al as the electrode was evaporated on the ethylcyclohexane films that grew on Pt coated silicon substrates, and the dielectric constants of the as-grown films were then calculated from C-V data measured at 1㎒. From the electrical property measurements such as I-V ana C-V characteristics, the minimum dielectric constant and the best leakage current of ethylcyclohexane thin films were obtained to be about 3.11 and 5 ${\times}$ 10$\^$-12/ A/$\textrm{cm}^2$ and cyclohexane thin films were obtained to be about 2.3 and 8 ${\times}$ 10$\^$-12/ A/$\textrm{cm}^2$.

  • PDF

Mathematical Consideration on PV Cell Modeling (PV cell modeling의 수학적 고찰)

  • Park, Hyeonah;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2014
  • PV cell modeling is necessary both for software and hardware simulators in analyzing and testing the performance of PV generation systems. Unique I-V curve of a PV cell identifies its own characteristics by electrical equivalent model that is composed of diode constants ($I_o$, $v_t$), photo-generated current ($I_{ph}$), series resistance ($R_s$), and shunt resistance ($R_{sh}$). Photo-generated current can be easily estimated since it is proportional to irradiation level. However, other electrical parameters should be solved from the manufacturer's data sheet that is consisted with three remarkable operating points such as open circuit voltage ($V_{oc}$), short circuit current ($I_{sc}$), and maximum power voltage/current ($V_{MPP}/I_{MPP}$). This paper explains and analyzes mathematical process of a novel PV cell modeling algorithm that was proposed by the authors with the name of "K-algorithm".

Intensive Monitoring Survey of Nearby Galaxies (IMSNG) : Constraints on the progenitor system of a normal Type Ia SN 2019ein from its light curve at the early phase

  • Lim, Gu;Im, Myungshin;Kim, Dohyeong;Paek, Gregory S.H;Choi, Changsu;Kim, Sophia;Hwang, Sungyong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.55.2-56
    • /
    • 2021
  • The progenitor of Type Ia supernovae (SNe Ia) is mainly believed to be a close binary system of acarbon-oxygen white dwarf (CO WD) and non-degenerate companion (single degenerate) or another WD (double degenerate). However, it is unclear which system is more prevalent. Here, we present a high cadence optical/Near-IR light curve of normal but slightly faint type Ia SN 2019ein from IMSNG project. We fit the early light curve (t <+8.3 days from the first detection) with various models to find the shock-heated cooling emission from SN ejecta-companion interaction. No significant shock-heated cooling emission is found, from which we constrain the progenitor star size as the following. The upper limit (Rupper,*) of the companion size in R-band is ~0.2R when forcing the first light time (tfl) to have one value and ~0.9R when using the mean value of tfl from the fitting in each band. Assuming the source of the I-band curve is almost powered from the radioactive decay, we obtained Rupper,*~1.2R. The early B-V color curve is in agreement with the model color curve of the 2M main sequence companion. These results allow us to at least rule out large stars like red giants as a companion star of the binary progenitor system of this supernova. B-R and V-R color do not show any significant signs of a red bump, which shows a thin helium shell (MHe<0.1M) for the sub-Mch WD (double detonation model). In addition, we estimated the distance to NGC 5353 as 37.098±0.028Mpc.

  • PDF

Computation of Ionic Conductivity in NASICON Solid Electrolytes (I) Conduction Paths with no Mid-Na Sites (NASICON 고체전해질의 이온전도도 계산 (I) Mid-Na의 영향을 고려하지 않은 경우)

  • 최진삼;서양곤;강은태
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.8
    • /
    • pp.957-965
    • /
    • 1995
  • The ionic conductivityof NASICON solid electrolytes was simulated by using Monte Carlo Method (MCM) based on a hopping model as functions of temoperature and composition. Two conduction paths were used : jumping from Na1 to Na2 and jumping from Na1 to Na2 and jumping from Na2 to Na2. Vacancy availability factor, V was affected by composition, temperature and the conduction paths. For β"-Alumina, it was known that the minimum of charge correlation factor, fc appears at the composition, p=0.5, but there was not shown the minimum of fc for NASICON. When the NASICON composition, x, approaches 2.5, the curve of In σT vs. 1/T* was shown Arrhenius behavior and also In (VWfc) was a linear function of 1/T*. The results of simulations on the considered conduction paths didn't agree with the experimental results. Thus it will be necessary to include the another Na sites as mid-Na site on the conduction path to obtain the better results.

  • PDF

Improvements of Grounding Performances Associated with Soil Ionization under Impulse Voltages (임펄스전압에 의한 토양의 이온화에 따른 접지성능의 향상)

  • Kim, Hoe-Gu;Lee, Bok-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.1971-1978
    • /
    • 2016
  • In this paper, electrical and physical characteristics associated with the ionization growth of soil under impulse voltages in a coaxial cylindrical electrode system to simulate a horizontally-buried ground electrode were experimentally investigated. The results were summarized as follows: Transient ground resistances decreased significantly by soil ionization. The voltage-current (V-I) curves for non-ionization in soil lined up in a straight line with the nearly same slope that is the ground resistance, but they showed a 'cross-closed loop' of ${\infty}$-shape under ionization. The conventional ground resistance and equivalent soil resistivity were inversely proportional to the peak value of injected impulse currents. On the other hand, the equivalent ionization radius and time-lag to the maximum value of ionization radius were increased with increasing the incident impulse voltages. An analysis method for the transient ground resistances of the ground electrode based on the ionization phenomena was proposed. The proposed method can be applied to analyze the transient performances of grounding systems for lightning protection in power system installations.

Tunneling Magnetoresistance in Si/$SiO_2$/NiFe/$Al_2$$O_3$/Co Thin Films (Si/$SiO_2$/NiFe/$Al_2$$O_3$/Co 박막의 투과자기저항 특성 연구)

  • 현준원;백주열
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.11
    • /
    • pp.934-940
    • /
    • 2001
  • Magnetic properties were investigated for Si/SiO$_2$/NiFe(300 )/A1$_2$O$_3$(t)/Co(200 ) junction related with the parameters of $Al_2$O$_3$. Insulating $Al_2$O$_3$ layer was formed by depositing a 5~40 thick Al layer, followed by a 90~120s RF plasma oxidation in an $O_2$ atmosphere. Magnetoresistance was not observed for tunnel junction with 5~10 thick Al layer, but magnetoresistance was observed large for tunnel junction with 15~40 thick Al layer. Oxidation time did not largely influence magnetoresistance. Tunnel magnetoresistance effect depended on magnetization behavior of two ferromagnetic layers. Tunneling junction was confirmed through nonlinear I-V curve. In this work, tunneling magnetoresistance(TMR) up to 30 % was observed. This apparent TMR is an artifact of the nonuniform current flow over the junction in the cross geometry of the electrodes.

  • PDF

Characteristics of Impulse Discharges in Wet Soil (습한 토양의 임펄스방전특성)

  • Kim, Hoe-Gu;Lee, Bok-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.363-369
    • /
    • 2017
  • This paper presents the experimental results related to soil ionization and electrical breakdown in a concentric hemispherical electrode system under lightning impulse voltages. Dynamic voltage-current and impedance-time characteristics of soil ionization were measured and analyzed. Also the electrical breakdowns of the soil gap were investigated. The time-lag to the peak current corresponds to the soil ionization propagation. The time of ionization propagation in wet sand is found to decrease with increasing the impulse currents. A drastic decrease in ground resistance was observed during the impulse current spreading in sand. The electrical breakdown appears at the wave tail of impulse voltage and results in a wide scatter in V-t curves. The voltage-current curves have a fan-like shape attributed to ionization processes which result in increasing current and decreasing voltage.

Analysis and control of PWM converter for V-I output chracteristic implementation of solar cell (태양전지의 V-I 특성 구현을 위한 PWM 컨버터의 해석 및 제어)

  • Ryu, T.G;Yoo, J.H;Han, J.M;Gho, J.S;Choe, G.H
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.67-71
    • /
    • 2001
  • In this paper, the virtual implement of solar cell was proposed to solve the problems as reappearance and repetition of some situation in experiment of photovoltaic. To realize the VISC, mathematical model of solar cell for driving converter was studied and the buck converter were compared in viewpoint of tracking error of characteristic curve of solar cell using computer simulation.

  • PDF

Thermodynamic Performance Analysis of Heat Pump Using Thermoelectric Semiconductor (열전반도체를 이용한 열펌프의 열역학적 성능 해석)

  • 박영무
    • Journal of Energy Engineering
    • /
    • v.2 no.1
    • /
    • pp.95-103
    • /
    • 1993
  • A conceptual thermoelectric heat pump(cooling mode) of small capacity is designed. Its performance is investigated through parametric analysis. COP and cooling capacity decease as the ambient temperature increases with ${\mu}$, J, T$\sub$wi/, fixed. To design a system of fixed capacity comes to calculate ${\mu}$ and J when T$\sub$wi/, and T$\sub$a/ are given. As v is fixed by semi-conductor manufacturers, optimum combination of n and I should be searched for ν. Optimum current could be calculated using ${\mu}$-J curve and optimum value of ${\mu}$. COR$\sub$R/ increases as water flow rate increases and T$\sub$a/ decreases. The effect of heat transfer coefficient at hot(heat releasing) side is more significant than that at cold(heat absorbing) side.

  • PDF

HPLC Analysis and Pharmacokinetics of KAL-1120, a Novel Anti-inflammation Agent, in Rats (흰쥐에서 항염증제 후보물질 KAL-1120의 HPLC 분석 및 약물동태)

  • Shin, Dae-Hwan;Lee, Jung-Yeol;Park, Seong-Hyeok;Lee, Gyeong-Bok;Han, Kun;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.2
    • /
    • pp.101-107
    • /
    • 2010
  • A rapid and sensitive reversed-phase high performance liquid chromatography (HPLC) method was developed for the determination of N-(-4-Chlorophenyl)-6-hydroxy-7-methoxy-2-chromanecarboxamide (KAL-1120), a novel anti-inflammation agent, in the rat plasma. The method was applied to analyze the compound in the biological fluids such as bile, urine and tissue homogenates. After liquid-liquid extraction, the compound was analyzed on an HPLC system with ultraviolet detection at 275 nm. HPLC was carried out using reversed-phase isocratic elution with a $C_{18}$ column, a mobile phase of a mixture of acetonitril (40 v/v%) at a flow rate of 1.0 mL/min. The chromatograms showed good resolution and sensitivity and no interference of plasma. The calibration curve for the drug in plasma was linear over the concentration range of 0.05-50 ${\mu}g$/mL. The intra- and inter-day assay accuracies of this method ranged from 0.06% to 9.33% of normal values and the precision did not exceed 6.28% of relative standard deviation. The plasma concentration of KAL-1120 decreased to below the quantifiable limit at 1.5 hr after the i.v. bolus administration of 2-10 mg/kg to rats ($t_{1/2,({\alpha})}$ and $t_{1/2,({\beta})$ of 2.15 and 26.7 min at a dose of 2 mg/kg, 3.91 and 33.0 min at a dose of 10 mg/kg, respectively). The steady-state volume of distribution ($V_{dss}$) and the total body clearance ($CL_t$) were not significantly altered in rats given doses from 2 to 10 mg/kg. Of the various tissues tested, KAL-1120 was mainly distributed in the lung and heart after i.v. bolus administration. KAL-1120 was detected in the bile by 30 min after its i.v. bolus administration. However, the concentration in the urine after i.v. bolus administration became too low to measure, suggesting that KAL-1120 is mostly excreted in the bile. In conclusion, this analytical method was suitable for the preclinical pharmacokinetic studies of KAL-1120 in rats.