• Title/Summary/Keyword: Hysteresis measurement

Search Result 184, Processing Time 0.028 seconds

Flux Jump of $MgB_2$ fabricated by commercial stainless steel tube enveloping technique (상용 스테인리스 스틸 튜브 봉합기법(COSSET)으로 제작 된 MgB$_2$flux jump 현상)

  • Lee, H.B.;Kim, B.J.;Kim, Y.C.;Jeong, D.Y.
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.27-31
    • /
    • 2002
  • MgB$_2$samples have been prepared by a stoichiometry mixture of Mg and B inside stainless steel tubes(Commercial Stainless Steel Tube Enveloping Technique). XRD data show that there are no second phases like MgO. The transition temperature of specimens is 37.5 K with a sharp transition width of ΔTc within 1K. From magnetic hysteresis measurement, flux jump was shown up to 15K, which was higher than that of samples by other methods. We have concluded that the flux jump is mainly affected by impurities and second phases.

  • PDF

Absolute Strain Measurement Using Fiber Bragg Grating Sensor (광섬유 브래그 격자 센서를 이용한 절대 변형률 측정)

  • ;Lou-shuang
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.416-420
    • /
    • 2002
  • This Paper describes a matched-filter type strain sensor system using optical fiber Bragg grating (FBG) sensor. Matched-filter type uses another wavelength-matched FBG filter to track wavelength shift in the FBG sensor. Filter FBG is attached on a fiber stretcher and stretched by PZT actuator. To overcome the nonlinearity and hysteresis of the PZT actuator that degrades system accuracy, a string resonator which can measure an absolute strain is employed. And the effect of vibration modes on string resonator is investigated particularly regarding its sensitivity and stability.

  • PDF

A study of the inductance measurement of an interior permanent magnet synchronous motor (매입형 영구자석 동기전동기의 인덕턴스 계측에 관한 연구)

  • Lee, Jeong-Hum;Kim, Young-Seok;Joung, Woo-Taik;Kim, Dai-Hyun;Choi, Yang-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.18-20
    • /
    • 2004
  • An interior permanent magnet synchronous motor (IPMSM) is receiving increased attention for many industrial applications because of its high torque to inertia ratio, superior power density, and high efficiency. IPMSM is necessary to use the accurate information of the inductace for the precise torque control owing to the reluctance torque. This paper presents two method to measure the each-axis inductance. The first method uses the peak current that is measured by applying the pulsewise voltage on the each position of IPMSM. The second uses the hysteresis loop of the flux and current measured by applying the positive and negative pulsewise voltage alternately on the each-axis.

  • PDF

Self-Compensation of PZT Errors in White Light Scanning Interferometry

  • Kang, Min-Gu;Lee, Sang-Yoon;Kim, Seong-Woo
    • Journal of the Optical Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.35-40
    • /
    • 1999
  • One of main error sources in white light scanning interferometry is the inaccuracy of scanning mechanisms in that PZT(piezoelectric transducer) micro-actuators are preferably used. We propose a new calibration method that is capable of identifying actual scanning errors directly by analyzing the spectral distribution of sampled interferograms. This calibration provides an effective means of self-compensation for the non-linearity errors caused by PZT hysteresis, enhancing the measurement uncertainty to a level of 5 nanometers over an entire measuring range of 100 ${\mu}{\textrm}{m}$.

Construction of a Pulsed Field Magnetometer and Magnetic Properties Measurement of Rare Earth Permanent Magnets (고자장 펄스마그네토미터 구성 및 희토류 영구자석의 자성측정)

  • 김윤배;우병칠;박포규;김만중;김택기
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.4
    • /
    • pp.212-216
    • /
    • 1997
  • A pulsed field magnetometer with maximum applied field of 130 kOe has been constructed. The pulsed field generated by a 18 kJ capacitor bank system combined with a pulse coil was damped oscillation with the period of 10.12 ms. Magnetic hysteresis loop was measured by induction method during 10.12 ms of a pulse duration from the first positive to the second positive peak. The difference from DC magnetic properties due to the eddy current effect was inferred below 3% for the NdFeB magnet with the diameter below 5 mm.

  • PDF

Fabrication and Characterizations of Thick PZT Films for Micro Piezoelectric Devices (마이크로 압전 소자용 후막 PZT의 제조 및 물성 평가)

  • 박준식;박광범;윤대원;박효덕;강성군;최태훈;이낙규;나경환
    • Transactions of Materials Processing
    • /
    • v.11 no.7
    • /
    • pp.569-574
    • /
    • 2002
  • Recently, thick PZT films are required for the cases of micro piezoelectric devices with high driving force, high breakdown voltage and high sensitivity, and so on. In this work, thick PZT films were fabricated by Sol-Gel multi-coating method. Microstructures, and electrical properties of films were investigated by XRD, FESEM, impedance analyzer, and P-E hysteresis. PZT films with 2.7$mu extrm{m}$ to 4.4${\mu}{\textrm}{m}$ thickness were fabricated. Dielectric constant, loss, remnant polarization and coercive field of them were 880~1650 at 1kHz, 2~3% at 1kHz, 26~32 $\mu$C/$ extrm{cm}^2$, and 33~60kV/cm, respectively. Also a transverse piezoelectric coefficient $(e_{31,f})$ measurement system was fabricated and tested for thick film samples.

Inductance Measurement Method of an IPMSM (매입형 영구자석 동기전동기의 인덕턴스 계측)

  • Lee, Jeong-Hum;Choi, Chang-Ho;Kim, Young-Seok;Kim, Min-Kyu;Wang, Hyo-Jin;Kim, Yun-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.11-13
    • /
    • 2005
  • An interior permanent magnet synchronous motor (IPMSM) is receiving increased attention for many industrial applications because of its high torque to inertia ratio, superior power density, and high efficiency. IPMSM is necessary to use the accurate information of the inductance for the precise torque control owing to the reluctance torque. This paper presents two method to measure the each-axis Inductance. The first method uses the peak current that is measured by applying the pulsewise voltage on the each position of IPMSM. The second uses the hysteresis loop of the flux and current measured by applying the positive and negative pulsewise voltage alternately on the each-axis.

  • PDF

A Study on Crystal Structure Growth of YbBCO Superconductor (YbBCO초전도체의 결정성장에 관한 연구)

  • 박정철;이영매;소대화
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.367-370
    • /
    • 1998
  • In this paper, based on the research of high temperature YBCO superconductor, using the Yb instead of Y, with the YbBCO superconductor powder which was combined by means of conventional solid reaction, textured directional crystal was prepared by MCP method and the character was analyzed. Mixing the starting elements and calcining at 890$^{\circ}C$, 900$^{\circ}C$, 910$^{\circ}C$, single phase YbBCO, Yb$_2$BaCuO$\sub$5/ and BaCuO$\sub$2/ were certified. And from the powder which was calcined at 900$^{\circ}C$ the, sample which became texture-growth by MCP method was well oriented. The result of DTA measurement, the fusing point of YbBCO superconductor and it\`s critical current was measured to be 979$^{\circ}C$, 87K respectively. The critical current density was obtained at the value of 700A/$\textrm{cm}^2$(77K. 0H) calculated by Bean's Model using the measured hysteresis curve of VSM.

  • PDF

Absorptance and Electrical Properties Evaluation of Nickel Layer Deposited onto Thin Film Pyroelectric PZT IR Detector (PZT박막 적외선 감지소자의 적외선 흡수층으로 증착된 니켈 박막의 광학 및 전기적 특성 분석)

  • Ko, Jong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.11
    • /
    • pp.1727-1732
    • /
    • 2004
  • A nickel layer was deposited onto the PZT thin films, serving both as a selective radiation absorption layer and as a top electrode. The absorption properties of such nickel coated multi-layered infrared detectors were studied in the visible and infrared wavelength ranges. The optimal thickness of the nickel layer on our substrate was 10nm. The maximum absorption coefficient of the deposited 10nm thick nickel layer was 0.7 at a 632nm wavelength. However, a striking asymmetric polarization hysteresis loop was observed in these PZT thin films with nickel as the top electrode. This asymmetric polarization was attributed to the difference between the dynamic pyroelectric responses in these Ni/PZT/Pt films poled either positively or negatively before the measurement. A positively poled film showed a 40% higher voltage response than a negatively poled detector.

Ferromagnetic Domain Behaviors in Mn doped ZnO Film

  • Soundararajan, Devaraj;Santoyo-Salazar, Jaime;Ko, Jang-Myoun;Kim, Ki-Hyeon
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.216-219
    • /
    • 2011
  • Mn doped ZnO films were prepared on Si (100) substrates using sol-gel method. The prepared films were annealed at $550^{\circ}C$ for decomposition and oxidation of the precursors. XRD analysis revealed the presence of ZnMnO hexagonal wurtzite phase along with the presence of small quantity of $ZnMn_2O_3$ secondary phase and poor crystalline nature. The 2D, 3D views of magnetic domains and domain profiles were obtained using magnetic force microscopy at room temperature. Rectangular shaped domains with an average size of 4.16 nm were observed. Magnetic moment measurement as a function of magnetic field was measured using superconducting quantum interference device (SQUID) magnetometry at room temperature. The result showed the ferromagnetic hysteresis loop with a curie temperature higher than 300 K.