• 제목/요약/키워드: Hysteresis Curve

검색결과 285건 처리시간 0.022초

Performance control analysis of concrete-filled steel tube sepa-rated spherical joint wind power tower

  • Yang Wen;Guangmao Xu;Xiazhi Wu;Zhaojian Li
    • Structural Engineering and Mechanics
    • /
    • 제87권2호
    • /
    • pp.137-149
    • /
    • 2023
  • In this study, to explore the working performance of the CFST split spherical node wind power tower, two groups of CFST split spherical joint plane towers with different web wall thicknesses and a set of space systems were analyzed. The tower was subjected to a low-cycle repeated load test, and the hysteresis and skeleton curves were analyzed. ABAQUS finite element simulation was used for verification and comparison, and on this basis parameter expansion analysis was carried out. The results show that the failure mode of the wind power tower was divided into weld tear damage between belly bar, high strength bolt thread damage and belly rod flexion damage. In addition, increasing the wall thickness of the web member could render the hysteresis curve fuller. Finally, the bearing capacity of the separated spherical node wind power tower was high, but its plastic deformation ability was poor. The ultimate bearing capacity and ductility coefficient of the simulated specimens are positively correlated with web diameter ratio and web column stiffness ratio. When the diameter ratio of the web member was greater than 0.13, or the stiffness ratio γ of the web member to the column was greater than 0.022, the increase of the ultimate bearing capacity and ductility coefficient decreased significantly. In order to maximize the overall mechanical performance of the tower and improve its economy, it was suggested that the diameter ratio of the ventral rod be 0.11-0.13, while the stiffness ratio γ should be 0.02-0.022.

토양수분 특성함수의 고차 SCANNING 커브에 대한 간략한 모델 (A SIMPLED MODEL FOR HIGHER ORDER SCANNING CURVES IN THE SOIL WATER CHARACTERISTIC FUNCTION)

  • 정상옥
    • 물과 미래
    • /
    • 제21권2호
    • /
    • pp.193-201
    • /
    • 1988
  • 토양수분 특성함수의 고차 scanning 커브에 대한 간략한 모델을 개발하였다. Mualem의 개념적 이력모델을 고차 scanning 커브에 대하여 간략하게 변형시켰다. 즉, 고차 건조곡선에 대하여는 마지막 회향점을 연직하향으로 이동시켜 주습윤곡선과 만나는 점을 회향점으로 하는 일차건조곡선으로 간주하였다. 또, 고차 습윤곡선에 대하여는 마지막 회향점을 지나는 가상의 주건조곡선에서 출발하는 일차습윤곡선으로 간주하였다. 이 간략한 모델을 사용하여 이차 scanning 커브에 대하여 계산한 토양 함수량과 Mualem의 모델을 이용해서 구한 토양 함수량을 비교하였다. 그 결과 두 모델 사이의 절대오차는 비교적 작았으며, 간략한 모델이 Mualem 모델보다 고차 건조시에는 항상 낮게, 고차 습윤시에는 항상 높게 함수량을 추정하였다. 따라서 건조와 습윤을 반복하는 경우 오차는 서로 상쇄된다. 본 연구에서 개발된 간략한 모델이 고차 scanning 커브에서의 토양 함수량을 잘 추정하였으며 계산과정을 많이 감소시켰다.

  • PDF

경사지반에 설치된 단일말뚝과 무리말뚝의 동적 상호작용 (Dynamic Interaction of Single and Group Piles in Sloping Ground)

  • ;유병수;김성렬
    • 한국지반공학회논문집
    • /
    • 제36권1호
    • /
    • pp.5-15
    • /
    • 2020
  • 말뚝의 동적거동은 말뚝과 지반 사이의 동적 상호작용에 큰 영향을 받는다. 특히, 경사지반에 설치된 말뚝은 진동방향에 따른 지반저항력 차이, 지반 변위 등에 의해 말뚝-지반 동적상호작용이 매우 복잡해진다. 본 연구에서는 건조 사질토 경사지반에 설치된 단일말뚝과 2×2 무리말뚝에 대하여 동적 원심모형실험을 수행하였다. 그리고, 말뚝과 지반 변위 사이의 위상차 및 동적 p-y 곡선 등을 산정하여 경사지반, 단일말뚝과 무리말뚝, 입력가속도 진폭 등의 조건이 말뚝-지반 동적 상호작용에 미치는 영향을 분석하였다. 그 결과, 지반-말뚝 사이의 운동학적 힘이 말뚝의 동적거동에 큰 영향을 주며, 동적 p-y 곡선이 지반경사, 잔류변위, 운동학적 힘의 영향 등으로 매우 복잡한 형상을 보여주는 것으로 나타났다.

단순 일축 비등방성 자성체의 돌림힘 곡선의 개형 (Torque Curve Shapes of Simple Uniaxial Magnetic Materials)

  • 허진;신성철
    • 한국자기학회지
    • /
    • 제8권1호
    • /
    • pp.34-41
    • /
    • 1998
  • 본 연구에서는 비가역 자벽이동 및 결맞음회전 이론을 함께 고려하여 단순 일축 자성체의 돌림힘곡선에서는 둥근(미분가능한) 정점들이 존재하기 위한 조건을 구하고 돌림힘 곡선의 개형을 이론적으로 연구하였다. 일축 비등방성 자성체의 돌림힘 곡선을 인가 자기마당이 변화함에 따라, 이력현상의 유무 및 자기화 역전기구의 종류와 미분 가능한 정점의 갯수에 의해 8가지의 유형들로 구별할 수 있었다. 비등방성 자기마당 세기가 같은 시료라도 자벽의 생성 및 이동에 필요한 최저 임계자기마당 세기가 다르면 상이한 모양의 돌립힘 곡선을 보였다. 한편, 미분 가능한 정점의 높이를 활용하여 포화 자기화량 및 비등방성 에너지 상수를 측정하는 기존의 돌림힘 곡선 해석법들은 인가 자기마당 세기가 비등방성 자기마당 세기의 약 77% 이상일 때 정확한 측정이 가능함을 알 수 있었다.

  • PDF

CVD 텅스텐의 응력 및 접합 누설전류 특성 (Stress and Junction Leakage Current Characteristics of CVD-Tungsten)

  • 이종무;최성호;이종길
    • 한국진공학회지
    • /
    • 제1권1호
    • /
    • pp.176-182
    • /
    • 1992
  • CVD 텅스텐의 응력 및 접합 누설전류 특성을 조사하였다. 응력-연속 어닐링온도 의 그래프는 냉각곡선의 응력이 가열곡선의 그것보다 더 높게 나타나는 이력현상을 보인다. SiH4 환원에 의하여 증착된 텅스텐 막이 수소환원에 의하여 증착된 막보다 전반적으로 내부 응력 뿐만 아니라 열 응력도 더 큰 것으로 나타났으며 전자가 후자에 비해 실리콘 기판과의 부착특성이 불량한 것도 이러한 응력차와 유관한 것으로 생각된다. SiH4 환원에 의하여 형 성된 텅스텐 막은 상온에서 인장 응력 상태에 있으며, 온도가 증가됨에 따라 응력이 감소하 다가 $700^{\circ}C$ 부근에서 압축 응력 상태로 바뀌고, 계속 더 온도가 증가됨에 따라 압축 응력 이 급격히 증가한다. SiH4 환원에 의한 텅스텐 막의 증착 온도가 증가함에 따라 n+/p 접합 의 누설전류가 크게 증가하며, 특히 $400^{\circ}C$로 온도가 증가함에 따라 누설전류의 증가폭이 크게 나타났는데, 이것은 수소환원 반응시와 유사하게 텅스텐의 침투(encroachment)에 의 한 실리콘 소모가 그 원인이다. SiH4/WF6 유속비의 증가에 따라서도 누설전류가 증가하는 데 그 효과는 미소한 것으로 나타났다.

  • PDF

Effects of reversing the coiling direction on the force-deflection characteristics of nickel-titanium closed-coil springs

  • Park, Hwan-Hyung;Jung, Suk-Hwan;Yoon, Juil;Jee, Kwang Koo;Han, Jun Hyun;Baek, Seung-Hak
    • 대한치과교정학회지
    • /
    • 제49권4호
    • /
    • pp.214-221
    • /
    • 2019
  • Objective: To investigate the effects of reversing the coiling direction of nickel-titanium closed-coil springs (NiTi-CCSs) on the force-deflection characteristics. Methods: The samples consisted of two commercially available conventional NiTi-CCS groups and two reverse-wound NiTi-CCS groups (Ormco-Conventional vs. Ormco-Reverse; GAC-Conventional vs. GAC-Reverse; n = 20 per group). The reverse-wound NiTi-CCSs were directly made from the corresponding conventional NiTi-CCSs by reversing the coiling direction. Tensile tests were performed for each group in a temperature-controlled acrylic chamber ($37{\pm}1^{\circ}C$). After measuring the force level, the range of the deactivation force plateau (DFP) and the amount of mechanical hysteresis (MH), statistical analyses were performed. Results: The Ormco-Reverse group exhibited a significant shift of the DFP end point toward the origin point (2.3 to 0.6 mm), an increase in the force level (1.2 to 1.3 N) and amount of MH (1.0 to 1.5 N) compared to the Ormco-Conventional group (all p < 0.001), which indicated that force could be constantly maintained until the end of the deactivation curve. In contrast, the GAC-Reverse group exhibited a significant shift of the DFP-end point away from the origin point (0.2 to 3.3 mm), a decrease in the force level (1.1 to 0.9 N) and amount of MH (0.6 to 0.4 N) compared to the GAC-Conventional group (all p < 0.001), which may hinder the maintenance of force until the end of the deactivation curve. Conclusions: The two commercially available NiTi-CCS groups exhibited different patterns of change in the force-deflection characteristics when the coiling direction was reversed.

Test for the influence of socket connection structure on the seismic performance of RC prefabricated bridge piers

  • Yan Han;Shicong Ding;Yuxiang Qin;Shilong Zhang
    • Earthquakes and Structures
    • /
    • 제25권2호
    • /
    • pp.89-97
    • /
    • 2023
  • In order to obtain the impact of socket connection interface forms and socket gap sizes on the seismic performance of reinforced concrete (RC) socket prefabricated bridge piers, quasi-static tests for three socket prefabricated piers with different column-foundation connection interface forms and reserved socket gap sizes, as well as to the corresponding cast-in-situ reinforced concrete piers, were carried out. The influence of socket connection structure on various seismic performance indexes of socket prefabricated piers was studied by comparing and analyzing the hysteresis curve and skeleton curve obtained through the experiment. Results showed that the ultimate failure mode of the socket prefabricated pier with circumferential corrugated treatment at the connection interface was the closest to that of the monolithic pier, the maximum bearing capacity was slightly less than that of the cast-in-situ pier but larger than that of the socket pier with roughened connection interface, and the displacement ductility and accumulated energy consumption capacity were smaller than those of socket piers with roughened connection interface. The connection interface treatment form had less influence on the residual deformation of socket prefabricated bridge piers. With the increase in the reserved socket gap size between the precast pier column and the precast foundation, the bearing capacity of the prefabricated socket bridge pier component, as well as the ductility and residual displacement of the component, would be reduced and had unfavorable effect on the energy dissipation property of the bridge pier component.

습윤경로 함수특성곡선을 고려한 불포화 편마풍화토 사면의 안정해석 (Stability Analysis on Unsaturated Gneiss Weathered Soil Slopes Considering Wetting Path Soil-Water Characteristic Curve)

  • 박성완;신길호
    • 대한토목학회논문집
    • /
    • 제29권5C호
    • /
    • pp.191-198
    • /
    • 2009
  • 국내 풍화사면에서의 표면파괴는 주로 강우에 의한 침투로 인하여 발생한다고 알려져 있다. 이러한 파괴는 표면토사부에 강우로 인한 하향 침투수에 흡수력의 감소와 습윤대의 증가에 의하여 야기된다. 따라서 국내에 흔히 존재하는 편마계열 풍화사면토를 대상으로 강우로 인한 습윤 경로 및 그 추이를 현상학적인 접근법으로 살펴볼 필요가 있다. 이에 본 논문에서는 풍화토를 대상으로 습윤 함수특성곡선에 대한 실내실험을 수행하고 결과를 활용하여 강우시 불포화 사면안정해석을 실시하였다. 기존 문헌의 자료에서 현장의 함수특성이 실내시험에서의 습윤경로에서 잘 반영하고 있어 상계 조건으로 실내시험에서 구한 습윤경로 함수특성곡선을 사면해석에 활용하는 것도 합리적임을 알 수 있다.

부산 임기광산 폐석적치장 광미의 불포화 특성곡선 산정 (Estimation on Unsaturated Characteristic Curves of Tailings obtained from Waste Dump of Imgi Mine in Busan)

  • 송영석;김경수;정승원;이춘오
    • 한국지반공학회논문집
    • /
    • 제30권3호
    • /
    • pp.47-58
    • /
    • 2014
  • 본 연구에서는 임기광산 폐석적치장을 형성하고 있는 광미의 불포화 특성을 조사하기 위하여 자동 흙-함수특성곡선(SWCC) 측정장치를 이용하여 건조 및 습윤과정에 따른 모관흡수력과 체적함수비를 측정하였다. 측정결과를 토대로 van Genuchten 방법을 이용하여 흙-함수특성곡선(SWCC)을 산정하였다. 산정된 흙-함수특선곡선(SWCC)의 ${\alpha}$와 n을 이용하여 흙의 종류를 구분하면 폐석적치장 광미시료는 점토질 모래(clayey sand)에 해당한다. Lu and Likos 방법으로 광미시료의 흡입응력특성곡선(SSCC)을 산정한 결과 흙-함수특성곡선(SWCC)과 유사한 S자형 곡선을 나타낸다. 동일한 유효포화도에서 건조과정의 흡입응력이 습윤과정의 흡입응력보다 크게 발생되는 이력현상이 나타났다. 그리고 불포화토의 유효응력은 공기함입치 이내로 작용할 경우 포화시 유효응력과 동일하나, 공기함입치 이상의 모관흡수력이 작용할 경우 포화토의 유효응력보다 큰 값을 갖는다. 한편, van Genuchten 방법으로 산정된 광미시료의 불포화 투수계수는 모관흡수력이 증가함에 따라 감소하며, 건조과정의 투수계수가 습윤과정의 투수계수보가 크게 발생됨을 알 수 있다.

불포화 준설매립 지반의 흙-수분 특성곡선 및 불포화 투수계수 예측 (Prediction of Soil-water Characteristic Curve and Unsaturated Permeability Coefficient of Reclaimed Ground)

  • 신은철;이학주;오영인
    • 한국지반공학회논문집
    • /
    • 제20권1호
    • /
    • pp.109-120
    • /
    • 2004
  • 불포화지반에서 발생되는 부 간극수압은 함수비 변화에 따라 비선형적인 거동을 보이며, 이 관계를 흙-수분 특성곡선(soil-water characteristic curve)이라고 정의한다. 현재까지 우리나라의 흙에 대한 흙-수분 특성의 연구결과는 거의 전무한 실정이기 때문에 불포화 지반의 응력해석 및 침투해석 시, 마땅히 입력할 계수나 특성값이 없다. 본 연구에서는 준설매립지반의 주요 토사인 준설토와 모래, 그리고 복토재로 사용되는 화강풍화토에 대한 흙수분 특성시험을 실시하여 흙-수분 특성을 규명하였으며, 해석적 검증을 통하여 불포화 지반의 응력해석 및 침투해석 시 필요한 계수를 분석하였다. 또한, 입도분포곡선으로부터 흙수분 특성곡선 예측모델을 적용하고 흙수분 특성시험 결과와 비교 검토하였다. 흙-수분 특성시험결과, 세 가지 시료 모두 뚜렷한 히스테리시스 현상을 나타내었으며, 기존에 제안된 경험방정식에 실험결과를 적용한 결과 Fredlund and Xing의 경험방정식은 세 가지 시료 모두에 대하여 높은 정확도를 나타내었다. 한편, 입도분포를 이용한 예측모델은 Fredlund and Wilson의 방법이 가장 높은 정확도를 나타내었다. 흙-수분 특성시험결과와 다양한 예측모델을 통하여 불포화 투수계수를 예측하여 상호 비교한 결과, 모래와 화강풍화토는 Fredlund and Wilson의 방법, 준설토는 Arya and Paris의 예측모델이 높은 정확도를 나타내었다.