• Title/Summary/Keyword: Hysteresis Characteristic

Search Result 183, Processing Time 0.031 seconds

Hysteresis Characteristics of a-Si:H TFT (비정질 실리콘 박막 트랜지스터 히스테리시스 특성)

  • 이우선;정용호;김남오;김병인;장의구
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.43-46
    • /
    • 1995
  • We fabricate a bottom gate a-Si:H TFT on N-Type <100> Si wafer. According to the variation of gate and drain voltage, the hysteresis characteristic curves were measured experimentally. Also, we showed that the model predict the hysteresis characteristic successfully. Drain current on the hysteresis characteristic currie showed an exponential variation. Hysteresis area of TFT increased with the drain voltage increase and decreases with the drain voltage decrease.

  • PDF

Mathematical Modeling of Hysteresis Characteristics of a-Si:H TFT (비정질 실리코 박막 트랜지스터 히스테리시스 특성의 수학적인 모델)

  • Lee, Woo-Sun;Kim, Byung-In
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1135-1143
    • /
    • 1994
  • We fabricate a bottom gate a-Si:H TFT on N-Type <100> Si wafer. According to the Variation of gate and drain voltage, the hysteresis characteristic curves were measured experimentally. Also, we proposed model equation and showed that the model predict the hysteresis characteristic successfully. Drain current on the hysteresis characteristic curve showed an exponential variation. Hysteresis area of TFT increased with the drain voltage increase and decreases with the drain voltage decrease.

  • PDF

A Study of Dynamic Characteristic of the Leaf Spring for Freight Wagon After the Derailment (탈선 후 화물열차의 겹판스프링 동적특성 연구)

  • 이응신;이장무
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.1
    • /
    • pp.49-54
    • /
    • 2004
  • Particularly derailing freight wagon, which are loaded with dangerous chemicals, has large damages on humans and environment. In this paper the dynamic characteristic of the laminated leaf spring under extreme situation, for example derailment, is examined. The leaf spring has a static hysteresis. Not only the friction value, but also the spring rate are influenced by this hysteresis characteristic. Because of the static hysteresis of the leaf spring the spring rate must be used in normal operation depending upon the loading and the kind of the excitation with the up to 10-fold value of the static spring rate. Some characteristics of the leaf spring can be treated like well-known viscous damping, but fer special situation (preload and/or excitation) particular calculation are necessary.

Finite Element Analysis for Hysteresis Motors (히스테리시스 전동기의 유한요소해석)

  • Hong, Sun-Ki;Won, Jong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.15-17
    • /
    • 1995
  • Hysteresis motor is a synchronous machine which has simple structure and self-start characteristic but also has serious difficulties in numerical analysis. In this study, a finite element analysis for hysteresis motor considering the hysteresis characteristics is presented. The hysteresis model is the magnetization-dependent Preisach model which explains hysteresis phenomena very well. From this, we estimate the instantaneous torque, average torque and hysteresis loss of the rotor, considering slot and winding distribution.

  • PDF

Effect of Hysteresis on Soil-Water Characteristic Curve in Weathered Granite and Gneiss Soil Slopes during Rainfall Infiltration (풍화계열 사면의 불포화 함수특성곡선 이력이 강우 침투에 미치는 영향)

  • Shin, Gil-Ho;Park, Seong-Wan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.28-33
    • /
    • 2006
  • Shallow failures of slopes in weathered soils are caused by infiltration due to prolonged rainfall. These failures are mainly triggered by the deepening of the wetting band accompanied by a decrease in suction induced by the water infiltration. In this paper, hysteresis on soil-water characteristic curve(SWCC) of granite and gneiss weathered soils are investigated using transient flow analysis respectively. Each case was subjected to artificial rainfall intensities and time duration depending on the laboratory-based drying and wetting processes. The results show that the unsaturated seepage on weathered slopes are very much affected by the initial suction of soils and unsaturated permeability of the soils. In addition, a granite weathered soil has a lower air-entry value, residual matric suction, and wetting front suction and less hysteresis loop than a gneiss weathered soil.

  • PDF

Characteristic Comparison between PI and Hysteresis Voltage Control of High Voltage Unidirectional Inverter for Piezoelectric Load using FPGA (FPGA를 이용한 피에조 부하 구동용 고전압 단방향 인버터의 PI 및 히스테리시스 전압 제어 특성 비교)

  • Kim, Ki-Seok;Cho, Yong-Ho;Kim, Hyeong-Seop;Kang, Tae-Sam;Hong, Sun-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.48-54
    • /
    • 2017
  • In this paper, hysteresis voltage control method is proposed to an unidirectional inverter control for piezoelectric load. Piezoelectric load has electrically RC characteristic, and is driven by the inverter to control the output voltage waveform. When controling the output waveform by PI control, appropriate gains need to be selected. However, hysteresis control may minimize the output distortion because it has maximum proportional gain. In addition, Hysteresis control algorithm has simple structure to realize and the response is fast. Although the switching frequency of the inverter by hysteresis control varies, the switching frequency for the piezoelectric load is lower than that by PI control for equivalent performance. In particular, on implementing the algorithm using FPGA, the algorithm can be implemented in fewer pabrics and the processing time can be reduced. The superiority of the proposed hysteresis voltage control was proved for piezoelectric load through simulation and experiment.

Method for improving the accuracy of a voltage transformer considering hysteresis characteristics (히스테리시스 특성을 고려한 전압 변성기 오차 개선 방법)

  • Kang, Yong-Cheol;Lee, Byung-Eun;Park, Jong-Min;Cha, Sun-Hee;Jang, Sung-Il;Kim, Yong-Guen
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.208-209
    • /
    • 2006
  • Voltage Transformer is used to transform high voltage into low voltage to input signal of protection relay. Most of the Voltage Transformers use the iron core which maximizes the flux linkage. The ratio of the Voltage Transformer depends on the transformer turns ratio. The current which flows in the Voltage Transformer has non-linear characteristic caused by hysteresis of the iron core, it causes a voltage loss in the winding impedances which makes measurement errors. This paper describes an error compensation method considering hysteresis characteristic. The proposed compensation method improves error by calculating the primary current from the exciting current of the hysteresis loop in the Voltage Transformer, compensating the voltage loss.

  • PDF

In Memristor Based Differential or Integral Control Circuit, Hysteresis Curve Characteristic Analysis According to Capacitance (멤리스터 기반 미분 및 적분제어 회로에서의 커패시턴스 변화에 따른 히스테리시스 곡선 특성 분석)

  • Choi, Jin-Woong;Mo, Young-Sea;Song, Han-Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.10
    • /
    • pp.658-664
    • /
    • 2015
  • This paper presents an electrical feature analysis of hysteresis curves in memristor differential and intergral control circuit. After making macro model of the memristor device, electric characteristics of the model such as time analysis, frequency dependent DC I-V curves were performed by PSPICE simulation. Also, we made a circuit of memristor-capacitor based on nano-wired memristor device and analyzed the simulated PSPICE results. Finally, we proposed a memristor based differential or integral control circuit, analyzed hysteresis curve characteristic in the control circuit.

Estimating the State-of-Charge of Lithium-Ion Batteries Using an H-Infinity Observer with Consideration of the Hysteresis Characteristic

  • Xie, Jiale;Ma, Jiachen;Sun, Yude;Li, Zonglin
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.643-653
    • /
    • 2016
  • The conventional methods used to evaluate battery state-of-charge (SOC) cannot accommodate the chemistry nonlinearities, measurement inaccuracies and parameter perturbations involved in estimation systems. In this paper, an impedance-based equivalent circuit model has been constructed with respect to a LiFePO4 battery by approximating the electrochemical impedance spectrum (EIS) with RC circuits. The efficiencies of approximating the EIS with RC networks in different series-parallel forms are first discussed. Additionally, the typical hysteresis characteristic is modeled through an empirical approach. Subsequently, a methodology incorporating an H-infinity observer designated for open-circuit voltage (OCV) observation and a hysteresis model developed for OCV-SOC mapping is proposed. Thereafter, evaluation experiments under FUDS and UDDS test cycles are undertaken with varying temperatures and different current-sense bias. Experimental comparisons, in comparison with the EKF based method, indicate that the proposed SOC estimator is more effective and robust. Moreover, test results on a group of Li-ion batteries, from different manufacturers and of different chemistries, show that the proposed method has high generalization capability for all the three types of Li-ion batteries.

A hysteresis model for soil-water characteristic curve based on dynamic contact angle theory

  • Liu, Yan;Li, Xu
    • Geomechanics and Engineering
    • /
    • v.28 no.2
    • /
    • pp.107-116
    • /
    • 2022
  • The steady state of unsaturated soil takes a long time to achieve. The soil seepage behaviours and hydraulic properties depend highly on the wetting/drying rate. It is observed that the soil-water characteristic curve (SWCC) is dependent on the wetting/drying rate, which is known as the dynamic effect. The dynamic effect apparently influences the scanning curves and will substantially affect the seepage behavior. However, the previous models commonly ignore the dynamic effect and cannot quantitatively describe the hysteresis scanning loops under dynamic conditions. In this study, a dynamic hysteresis model for SWCC is proposed considering the dynamic change of contact angle and the moving of the contact line. The drying contact angle under dynamic condition is smaller than that under static condition, while the wetting contact angle under dynamic condition is larger than that under static condition. The dynamic contact angle is expressed as a function of the saturation rate according to the Laplace equation. The model is given by a differential equation, in which the slope of the scanning curve is related to the slope of the boundary curve by means of contact angle. Empirical models can simulate the boundary curves. Given the two boundary curves, the scanning curve can be well predicted. In this model, only two parameters are introduced to describe the dynamic effect. They can be easily obtained from the experiment, which facilitates the calibration of the model. The proposed model is verified by the experimental data recorded in the literature and is proved to be more convenient and effective.