• 제목/요약/키워드: HygroThermal

검색결과 43건 처리시간 0.022초

Vibration analysis of magneto-flexo-electrically actuated porous rotary nanobeams considering thermal effects via nonlocal strain gradient elasticity theory

  • Ebrahimi, Farzad;Karimiasl, Mahsa;Mahesh, Vinyas
    • Advances in nano research
    • /
    • 제7권4호
    • /
    • pp.223-231
    • /
    • 2019
  • In this article the frequency response of magneto-flexo-electric rotary porous (MFERP) nanobeams subjected to thermal loads has been investigated through nonlocal strain gradient elasticity theory. A quasi-3D beam model beam theory is used for the expositions of the displacement components. With the aid of Hamilton's principle, the governing equations of MFERP nanobeams are obtained. Further, administrating an analytical solution the frequency problem of MFERP nanobeams are solved. In addition the numerical examples are also provided to evaluate the effect of nonlocal strain gradient parameter, hygro thermo environment, flexoelectric effect, in-plane magnet field, volume fraction of porosity and angular velocity on the dimensionless eigen frequency.

Accelerated Degradation Stress of High Power Phosphor Converted LED Package (형광체 변환 고출력 백색 LED 패키지의 가속 열화 스트레스)

  • Chan, Sung-Il;Jang, Joong-Soon
    • Journal of the Microelectronics and Packaging Society
    • /
    • 제17권4호
    • /
    • pp.19-26
    • /
    • 2010
  • We found that saturated water vapor pressure is the most dominant stress factor for the degradation phenomenon in the package for high-power phosphor-converted white light emitting diode (high power LED). Also, we proved that saturated water vapor pressure is effective acceleration stress of LED package degradation from an acceleration life test. Test conditions were $121^{\circ}C$, 100% R.H., and max. 168 h storage with and without 350 mA. The accelerating tests in both conditions cause optical power loss, reduction of spectrum intensity, device leakage current, and thermal resistance in the package. Also, dark brown color and pore induced by hygro-mechanical stress partially contribute to the degradation of LED package. From these results, we have known that the saturated water vapor pressure stress is adequate as the acceleration stress for shortening life test time of LED packages.

Mathematical modeling of actively controlled piezo smart structures: a review

  • Gupta, Vivek;Sharma, Manu;Thakur, Nagesh
    • Smart Structures and Systems
    • /
    • 제8권3호
    • /
    • pp.275-302
    • /
    • 2011
  • This is a review paper on mathematical modeling of actively controlled piezo smart structures. Paper has four sections to discuss the techniques to: (i) write the equations of motion (ii) implement sensor-actuator design (iii) model real life environmental effects and, (iv) control structural vibrations. In section (i), methods of writing equations of motion using equilibrium relations, Hamilton's principle, finite element technique and modal testing are discussed. In section (ii), self-sensing actuators, extension-bending actuators, shear actuators and modal sensors/actuators are discussed. In section (iii), modeling of thermal, hygro and other non-linear effects is discussed. Finally in section (iv), various vibration control techniques and useful software are mentioned. This review has two objectives: (i) practicing engineers can pick the most suitable philosophy for their end application and, (ii) researchers can come to know how the field has evolved, how it can be extended to real life structures and what the potential gaps in the literature are.

Study on the Mechanical Behavior of Fiber Metal Laminates Using Classical Lamination Theory (고전 적층이론에 의한 섬유금속적층판의 기계적 거동 연구)

  • 노희석;최흥섭;강길호;하민수
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 한국복합재료학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.37-41
    • /
    • 2003
  • In this study the mechanical behaviors of fiber metal laminates (FML) such as ARALL, GLARE and CARE which are recently developed as new structural materials and known to have excellent fatigue resistant characteristics while with relatively low densities compared to the conventional aluminum materials, are considered through the classical lamination theory. The mechanical properties such as elastic moduli, thermal expansion coefficients and hygro-thermally induced residual stresses in the fiber metal laminates are obtained and compared each other. Also load carrying mechanism between metal sheets and composite layers in the FML are considered.

  • PDF

Numerical analysis of high-strength concrete exposed elevated temperature (고온에 노출된 고강도 콘크리트 기둥의 수치해석)

  • Seo, Yeon-Joo;Hong, Sung-Gul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.21-24
    • /
    • 2005
  • A computational analysis of hygro-thermal and mechanical behaviour of concrete column at high temperature is presented. The objective of this study is to develop a finite difference model that simulates coupled heat and transport phenomena in reinforced concrete structures exposed to rapid heating conditions such as fires. The theoretical basis for the integrated finite difference method is presented to describe a powerful numerical technique for solving of fluid flow in porous media. The numerical results predict the phenomena of 'moisture clog' and the explosive spalling of concrete under fire. The investigations show that high-strength concrete(HSC) and normal-strength concrete(NSC) exposed to high temperature have different pore pressure buildup dependent on porosity, permeability and moisture contents. HSC has more possibility than NSC on spalling.

  • PDF

Mechanical and hygrothermal behaviour of functionally graded plates using a hyperbolic shear deformation theory

  • Laoufi, Imene;Ameur, Mohammed;Zidi, Mohamed;Bedia, El Abbes Adda;Bousahla, Abdelmoumen Anis
    • Steel and Composite Structures
    • /
    • 제20권4호
    • /
    • pp.889-911
    • /
    • 2016
  • Using the hyperbolic shear deformation plate model and including plate-foundation interaction (Winkler and Pasternak model), an analytical method in order to determine the deflection and stress distributions in simply supported rectangular functionally graded plates (FGP) subjected to a sinusoidal load, a temperature and moisture fields. The present theory exactly satisfies stress boundary conditions on the top and the bottom of the plate. No transversal shear correction factors are needed because a correct representation of the transversal shearing strain is given. Materials properties of the plate (elastic, thermal and moisture expansion coefficients) are assumed to be graded in the thickness direction according to a simple power-law distribution in terms of the volume fractions of the constituents. Numerical examples are presented and discussed for verifying the accuracy of the present theory in predicting the bending response of FGM plates under sinusoidal load and a temperature field as well as moisture concentration. The effects of material properties, temperature, moisture, plate aspect ratio, side-to-thickness ratio, ratio of elastic coefficients (ceramic-metal) and three distributions for both temperature and moisture on deflections and stresses are investigated.

Structural Design and Experimental Investigation of A Medium Scale Composite Wind Turbine Blade Considering Fatigue life

  • Kong, C.D.;Bang, J.H.;Jeong, J.C.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 한국추진공학회 2002년도 제18회 학술발표대회 논문초록집
    • /
    • pp.88-89
    • /
    • 2002
  • The aims of this study is to realize the structural design for development of a medium scale E-glass/epoxy composite wind turbine blade for a 750KW class horizontal axis wind turbine system. In this study, the various load cases specified by the IEC61400-1 international specification and GL Regulations for the wind energy conversion system were considered, and a specific composite structure configuration which can effectively endure various loads such as aerodynamic and centrifugal loads, loads due to accumulation of ice, hygro-thermal and mechanical loads was proposed. In order to evaluate the structure, the structural analysis for the composite wind turbine blade were peformed using tile finite element method(FEM). In the structural design, the acceptable blade structural configuration was determined through the parametric studies, and the most dominant design parameters were confirmed. In the stress analysis using the FEM, it was confirmed that the blade structure was safe and stable in any various load cases Moreover the safety of the blade root joint with insert bolts, newly devised in this study, was checked against the design fond and the fatigue.

  • PDF

Spalling Analysis of High-Strength Reinforced Concrete Columns under High Temperature (고온에 노출된 고강도 콘크리트 기둥의 폭렬해석)

  • Shin, Sung-Woo;Yoo, Suk-Hyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제11권6호
    • /
    • pp.193-200
    • /
    • 2007
  • The spalling analysis of high strength concrete columns needs a very complex and difficult process accounting for peeling of cover concrete as well as thermal, thermo-stress and hygro-transfer phenomena. However, the study on the spalling analysis method is insufficient. The practical spalling analysis algorithm is developed in this study, which formulates a vapor pressure equation as the parameter of temperature and cover depth and uses the compatibility condition In results of the spalling analysis, as the concrete strength increases and the content of PP fiber decreases the degree of spalling increases. This shows a similar result as the previous experimental study. Therefore the developed algorithm suggested in this study is expected to be useful in predicting the spalling of high strength concrete columns.

Hygrothermal Fracture Analysis of Plastic IC Package in Reflow Soldering Process (리플로 납땜 공정에서 플라스틱 IC 패키지의 습기 및 열로 인한 파손문제 해석)

  • Lee, Kang-Yong;Lee, Taek-Sung;Lee, Kyung-Seob
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제20권4호
    • /
    • pp.1347-1355
    • /
    • 1996
  • The purpose of this paper is to evaluate the delamination and fracture integrity of the IC plastic package under hygrothermal loading by stress analysis and fracture mechanics approaches. The plastic SOJ package with a dimpled diepad under the reflow slodering process of IR heating type is considered. On the package without a crack, the stress variation according to the change of the design variables such as the material and shape of the package is calculated and the possibility of delamination is considered. For the model fully delaminated between the chip and diepad, J-integrals are calculated for the various design variables and the fracture integrity is discussed. From the results, optimal design values of variables to prevent the delamination and fracture of IC package are obtained. In this study, FDM program to obtain the vapor pressure from the content of moisture absorbed into the package is developed.

Effect of Foliage Plant Pachira aquatica on the Change of Indoor Temperature and Humidity (관엽식물 파키라가 실내 온·습도 변화에 미치는 영향)

  • Son, Ki-Cheol;Kim, Mi-Kyoung;Park, So-Hong;Chang, Myoung-Kap
    • Horticultural Science & Technology
    • /
    • 제16권3호
    • /
    • pp.377-380
    • /
    • 1998
  • In order to investigate the effects of foliage plants on the changes of indoor thermal- and hygro- environments, experiments were carried out in two rooms with similar physical factors. Changes of indoor environmental parameters according to the existence of plants, their arrangement methods, and the existence of wrapseal for protecting the loss of water from the pot soil were measured during certain periods in winter and summer season, using Pachira aquatica which is widely used as indoor plant and has higher photosynthetic and traspiration rate than other foliage plants. The data suggested that the existence of plants didn't affect directly on the indoor thermal environment, while relative humidity increased about 3~5%, regardless of season, by putting plants which had volume equivalent to 2.4% of room volume. In summer, there was no difference in increasing effect of relative humidity between parallel arrangement with window and spread arrangement in the room, but in winter the former arrangement was more effective than the later.

  • PDF