• Title/Summary/Keyword: Hydrostatic pressure

Search Result 494, Processing Time 0.023 seconds

Effects of High Hydrostatic Pressure and Gamma Irradiation on Quality and Microbiological Changes of Kochujang-Gulbi. (고추장굴비의 품질과 저장성에 미치는 초고압처리와 감마선 조사 효과)

  • Kang, Seong-Gook;Park, Nan-Hee;Ko, Do-Ock;Li, Jing-Lei;Kim, Bo-Sub;Park, Yang-Kyun
    • Food Science and Preservation
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Kochujang-gulbi, a Korean traditional food, was prepared with kochujang and freeze-dried gulbi slices. Kochujang-gulbi was treated with high hydrostatic pressure (200, 400 and 600 MPa) and gamma-irradiation (7, 10, 20 and 30 KGy) to improve its quality and shelf-life. The pH of high hydrostatic pressure and gamma-irradiation treated kochujang-gulbi samples did not significantly different compared to that of control. However, Hunter L value slightly increased, and Hunter a and b values decreased by high hydrostatic pressure and gamma-irradiation treatment. During storage, the pH and color of high hydrostatic pressure and gamma-irradiation treated kochujang-gulbi samples did not significantly changed. The VBN and TBA level decreased by the increase treatment of high hydrostatic pressure and then slowely increased during storage. The VBN and TBA level of kochujang-gulbi samples treated by the strong gamma ray emission slowely increased during storage. In particular, gamma-irradiation treatment was very effective to sterilize microorganisms when compared to that of high hydrostatic pressure in kochujang-gulbi products. In addition, the high hydrostatic pressure and gamma-irradiation treated kochujang-gulbi samples shown significantly lower total viable cell number than control for the 20 days of storage at room temperature with retort pouch packaging.

A Study on the Effect of Energy Dissipation in Extruding Clad Rod (복합봉재 압출에 의한 에너지 소산의 영향에 관한 연구)

  • Kim, Chang-Hoon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.5 no.2
    • /
    • pp.56-64
    • /
    • 2006
  • Rapid progress in many branches of technology has led to a demand on new materials such as high strength light weight alloys, powdered alloys and composite materials. The hydrostatic extrusion is essentially a method of extruding a clad rod through a die. In order to investigate the effect of the process conditions such as friction heat, deformation and clad thickness on the clad extrusion process, viscoplastic finite element simulations were conducted. A specific model for theoretical analysis used in this study is The single scalar variable version of Hart's model. An experiment also has been carried out using 1.5MN hydrostatic extruder with variable speed ram, LVDT and load cell for comparison. It is found that the hydrostatic extrusion pressure considering the effect of heat dissipation in this theoretical work was closer to the experimental pressure than the isothermal hydrostatic extrusion pressure.

  • PDF

A Comparison of Standard Methods for Evaluating the Water Resistance of Shell Fabrics

  • Kwon, Myoung-Sook;Nam, Youn-Ja
    • The International Journal of Costume Culture
    • /
    • v.4 no.3
    • /
    • pp.241-248
    • /
    • 2001
  • Re water resistance of shell fabrics intended for we in outdoor apparel was measured using three different standard test methods, ASTM D 751, hydrostatic resistance, procedure A(Mullen test -- with and without a fabric support) and Procedure B (Hydrostatic head test). A database of information on their water resistance performance was created. The data collected with different methods were correlated and the advantages and disadvantages of each method were compared. The Mullen test with a support appears to give higher and more favorable water resistance values on shell fabrics preventing fabric rupture during the test. The hydrostatic head test gave lower hydrostatic pressure values than those measured on the two Mullen tests. The Mullen test is recommended for testing the water resistance of fabrics that high a relatively high water resistance because the Mullen tester applies a wide range of pressure. The hydrostatic head test is recommended for testing the fabrics that have relatively low water resistance. The area of the fabric sample that is in contact with the water is smaller in the Mullen test, so higher pressure levels can be reached and more samples should probably be tested to get a representative value for each fabric types. Furthermore, the hydrostatic head test was deemed more repeatable than the Mullen tests in his study.

  • PDF

Application of Biological industry using High Hydrostatic Pressure (HHP) system (초고압 시스템을 이용한 생물 산업의 적용)

  • Lee, Kwang-Jin;Choi, Sun-Do
    • KSBB Journal
    • /
    • v.23 no.5
    • /
    • pp.362-368
    • /
    • 2008
  • High Hydrostatic Pressure assisted (HHP) process enhancement for food and allied industries are reported in this paper review. Recently, considerable research has been devoted to the improvement of mild thermal processing techniques and to the development of alternative mild processing technologies. HHP assisted can enhance existing extraction, processes and enable new commercial extraction opportunities and processes. New HHP processing approaches have been proposed, including, the potential for modification of plant cell material to provide improved bioavailability of micro nutrients while retaining the natural-like quality, simultaneous extraction. Therefore, High Hydrostatic Pressure assisted (HHP) technologies could have a strong presence in the future of the biotechnology industry.

Pressure Ripple Characteristics of Hydrostatic Transmission (HST) (유압전동장치(HST)의 압력맥동 특성)

  • 김도태
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.222-227
    • /
    • 1998
  • The paper proposes a new method for measuring the flow ripple generated by an axial piston pump and motor in a hydrostatic transmission. The method is based on dynamic characteristics between pressure and flow ripple in the pipeline. Also, the self-checking functions develop for the evaluation of accuracy and dynamic response of estimated results by the method proposed here. The experiment carry out open circuit type hydrostatic transmission. By using the self-checking functions, the validity of the method is investigated by comparison with the measured and estimated flow and pressure ripples, and good agreement is achieved.

  • PDF

Micro Forming with Hydrostatic Pressure -Hydro-Mechanical Role Punching- (정수압을 이용한 미세 성형 -Hydro-Mechanical Hole Punching-)

  • 박훈재;김승수;최태훈;김응주;나경환
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10a
    • /
    • pp.386-390
    • /
    • 2003
  • As a trial of application of hydrostatic pressure in micro fomring, burr-free punching has been conducted by means of hydro-mechanical procedure. Even though it is in beginning stage, result of the hydro-mechanical punching is promising. Hydrostatic pressure helps delay fracture initiation and makes it possible to get clean shearing surface. Without any burr on both side of sheet, smooth holes are archived as intended. To verify the significance of hydro-mechanical punching, conventional punching is performed under similar conditions and relatively larger portion of fracture surface is detected in the punching hole. Despite the quality of sidewall is not good enough, it might be possible to make the hole shaped upright, reduce the roll-over radius and minimize the fracture surface by optimizing process parameters.

  • PDF

Effects of the Hydrostatic Test and the Operating Condition on Weld Residual Stress at a Safety Nozzle of the Pressurizer (수압시험 및 운전조건이 가압기 안전노즐의 용접잔류응력에 미치는 영향 평가)

  • Lee, Kyoung Soo;Lee, Sung Ho;Kim, Wan Jae
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.8 no.1
    • /
    • pp.19-24
    • /
    • 2012
  • This paper presents the results of finite element analysis for the effects of hydrostatic test and operating condition on the weld residual stress at dissimilar metal weld of a pressurizer safety nozzle in a nuclear power plant. For the study, the weld residual stress at ambient condition was analyzed using ABAQUS in the first place. After the weld residual stress analysis, the hydrostatic test condition and operating condition was applied to the same model one after another. The weld residual stress was observed to change due to the successive hydrostatic test and operating condition. The axial residual stresses on inner surface of the dissimilar metal weld and HAZ region were decreased by hydrostatic test and operating condition, which gives beneficial effect on preventing primary water stress corrosion cracking.

Flow and Pressure Ripple Characteristics of Hydrostatic Transmissions (유압전동장치의 유량 압력맥동 특성)

  • 김도태;윤인균
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.1
    • /
    • pp.120-126
    • /
    • 2001
  • This study deals with a flow and pressure ripple characteristics for a hydrostatic transmission(HST) consisting of a vari-able axial piston pump connected in an open loop to a fixed displacement axial piston motor. These flow ripples produced by pump and motor in HST interacts with the source impedances of the pump or motor and dynamic characteristics of the connected pipeline, and results in a pressure ripples, Pressure ripples. Pressure ripples in HSP is major source of vibration, which can lead to fatigue failure of components and cause noise. In this paper, the flow ripples generated by a swash plate type axial piston pump or motor in HST are measured by making use of hydraulic pipeline dynamics and the measured pressure data at two points along the pipeline. By using the self-checking functions, the validity of the method us investigated by comparison with the measured and estimated pressure ripples at the halfway section of the pipeline, and good agreement is achieved.

  • PDF

Pressure Ripple Reduction in Hydrostatic Transmissions by Using a Hydraulic Filter (맥동흡수용 유압필터에 의한 유압전동장치의 압력맥동 감쇠)

  • 김도태
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.3
    • /
    • pp.33-38
    • /
    • 2002
  • This paper deals with pressure ripple attenuation far separated-type Hydrostatic Transmission (HST) consisting ova variable axial piston pump connected in an open loop to a fried displacement axial piston motor. Pressure ripples in HST is major source of vibration which can lead to fatigue failure of components and cause noise. In order to reduce the pressure ripple, an annular tube tripe hydraulic filter is proposed to attenuate pressure ripples with the high frequencies components to achieve better noise reduction in HST. The basic principle of a hydraulic filter is allied to propagation of pressure wave, reflection, absorption in cross section of discontinuity and resonance in the hydraulic pipeline. It is experimentally shown that the hydraulic filter attenuates about 30∼40dB of pressure ripple with high frequencies. These results will assist in modeling and design of noise reduction in hydraulic control systems, and provide a means of designing a quieter HST.

Application of a Non-Hydrostatic Pressure Model with Dynamic Boundary Condition to Free Surface Flow (동역학적 경계조건을 갖는 동수압 모형의 자유수면흐름에의 적용)

  • Lee, Jin-Woo;Jeong, Woo-Chang;Cho, Yong-Sik
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.1
    • /
    • pp.103-109
    • /
    • 2010
  • In this study, a three-dimensional non-hydrostatic pressure model based on a normalized vertical coordinate system for free surface flows is presented. To strongly couple the free surface and non-hydrostatic pressure with the momentum equations, a double predictor-corrector method is employed. The study is especially focused on implementing the dynamic boundary condition (a zero pressure condition) at the free surface with ignoring of the atmospheric pressure. It is shown that the boundary condition can be specified easily with a slight modification to existing models.