• Title/Summary/Keyword: Hydrogeologic

Search Result 108, Processing Time 0.022 seconds

An Interpretation of Hydrogeologic Structure Using Geophysical Data from Chungwon Area, Chungcheongbuk-Do (물리탐사자료를 이용한 수리지질구조 해석 -충청북도 청원지역)

  • 송성호;정형재;권병두
    • Economic and Environmental Geology
    • /
    • v.33 no.4
    • /
    • pp.283-293
    • /
    • 2000
  • A set of geophysical survey results over an area in Bookil-myun, Chungwon-Gun, Chungcheongbuk-Do is presented; resistivity logging, d.c. sounding, dipole-dipole resistivity, and controlled-source magnetotelluric (CSMT) surveys. These surveys were chosen in this research for the estimation of the basement depth and the delineation of the hydrogeologic structure over the survey area. The results provide an optimal input to a hydrogeologic modeling analysis using the strategies built in GIS software. A total of 14 lines of dipole-dipole resistivity surveys, 25 stations of d.c. sounding and 6 stations of CSMT sounding were performed. In addition 10 boreholes were chosen for resistivity logging to correlate the logs to the surface data. A quantitative information on the hydrogeologic structure over the area is provided by synthesizing the results from various geophysical data and attribute layers are constructed by utilizing a GIS software Arc/ Info. The constructed layers match well to the hydrogeologic structures, which were outlined from the drilling data. The methodology tested and adopted in this study would be useful for providing a more reliable input to the hydrogeologic model setup.

  • PDF

ArcView와 Avenue$^{TM}$ Language를 활용한 수문지질도 도식 표현 기법 개발

  • 김규범;조민조;이장룡
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.31-35
    • /
    • 2000
  • We investigate the groundwater distribution and chemical characteristics for 3 or 5 districts every year and make the hydrogeologic map on a scale of 1:50,000. We draw the hydrogeologic digital map based on "The Handbook for the Drawing and Management of Hydrogeologic Map" which was published by MOCT and KOWACO in 1998. But, the Stiff diagram and well's notation are difficult to be presented in the digital map using the commercial Arcview GIS tools. So we develop the script file with Avenue language to represent them in Arcview GIS tool. At first, we design the database for the chemical analysis result of groundwater and well identification, and make the program code with Avenue language to display them on the digital map. And next we test the usefulness of the program code. As a result, we find that the script file is very useful for drawing the symbols and diagrams in hydrogeologic digital map using ArcView GIS.

  • PDF

지표수 수위변동을 이용한 대수층 수리상수 추정

  • 하규철;조민조
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.426-430
    • /
    • 2004
  • In aquifers connected hydraulically, the levels of groundwater respond to stream stages. Analytical solutions by Laplace transform and convolution integral are used to get some response patterns about hydrogeoiogic parameter such as hydraulic conductivity, specific storage in confined aquifer. This method has the advantage to do hydrogeologic parameter estimations only with stream stage changes.

  • PDF

Sensitivity Analysis of Hydrogeologic Parameters by Groundwater Table Fluctuation Model in Jeju Island (지하수위 변동 해석모델을 이용한 제주지역의 수리지질 매개변수 민감도 분석)

  • Kim, Nam Won;Kim, Youn Jung;Chung, Il-Moon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1409-1420
    • /
    • 2014
  • In this work, we have carried out a sensitivity analysis of hydrogeologic parameters such as reaction factor and drainable pore space in groundwater table fluctuation model and have found characteristics of parameter distribution according to the altitude. We found that drainable pore space which is hydrogeologic parameter of aquifer didn't show any trend with altitude while reaction factor which is groundwater flow characteristic showed clear trend with altitude. To find a sensitivity of parameters, we compared RMSE of estimated groundwater recharges by using the mean value and linear relationship of parameters. As results, the linear equation derived for entire watersheds could be applied to estimate parameters for ungauged watershed. Furthermore, the features of parameter distribution can be used to predict hydrogeologic parameter in ungauged watersheds and it is expected that those features could be used for a basic data for groundwater modeling.

현장 규모 biobarrier의 수리학적 특성과 기초 설계

  • 최영화;오재일;왕수균;배범한
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.426-430
    • /
    • 2003
  • Subsurface biobarrier technology has potential applications to contain contaminated groundwater and/or to degrade toxic pollutants in groundwater. Effective biobarrier formation is need to assess of hydrogeologic characteristics and to conduct practical operation strategies and design based on this prior to design biobarrier. Thus, in this study, we examined hydrogeologic characteristics in biobarrier construction site. Hydraulic conductivities which calculated from slug test data have shown difference with each well as 1.20$\times$10$^{-3}$ -6.00$\times$10$^{-5}$ cm/sec. Tracer test is a method in which concentration of tracer solution during withdrawal in each well by vacuum extraction system is measured with time. Tracer solution was continuously injected by constant head tank. Measured tracer concentration versus time data were fitted to analytical solution of convection dispersion equation (CDE). The fitting data of CDE to the measured data at each extraction well yielded were 0.61cm/min(pore velocity), 5.38$\textrm{cm}^2$/min(dispersion coefficient) for discharge rate of 0.47 1/min and 1.75cm/min(pore velocity), 36.34$\textrm{cm}^2$/min(dispersion coefficient) for discharge rate of 0.93 1/min. As a result, we acquired fundamental parameters which need to design biobarrier and operation strategies.

  • PDF

FEASIBILITY MAPPING OF GROUND WATER YIELD CHARACTERISTICS USING WEIGHT OF EVIDENCE TECHNIQUE: A CASE STUDY

  • Heo, Seon-Hee;Lee, Ki-Won
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.430-433
    • /
    • 2005
  • In this study, weight of evidence(WOE) technique based on the bayesian method was applied to estimate the groundwater yield characteristics in the Pocheon area in Kyungki-do. The ground water preservation depends on many hydrogeologic factors that include hydrologic data, landuse data, topographic data, geological map and other natural materials, even with man-made things. All these data can be digitally collected and managed by GIS database. In the applied technique of WOE, The prior probabilities were estimated as the factors that affect the yield on lineament, geology, drainage pattern or river system density, landuse and soil. We calculated the value of the Weight W+, W- of each factor and estimated the contrast value of it. Results by the ground water yield characteristic calculations were presented in the form of posterior probability map to the consideration of in-situ samples. It is concluded that this technique is regarded as one of the effective technique for the feasibility mapping related to detection of groundwater bearing zones and its spatial pattern.

  • PDF

Interpretation of shallow geological structure by applying GIS to geophysical data (물리탐사자료의 GIS 복합처리에 의한 천부지질구조 해석)

  • 송성호;정형재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.123-126
    • /
    • 1998
  • We have conducted surface electrical resistivity surveys along with the electrical logging at Bookil-Myun, Chungwon-Goon, Choongchungbuk-Do to determine the depths of basement and water table, and for the purpose of preparing the basic input data for hydrogeologic model combined with GIS. A twenty lines of dipole-dipole array survey and a twenty-five stations of resistivity sounding were performed and ten holes were employed for electrical logging to cross check the surface data. A combined interpretation gave the quantitative information of the shallow geologic structure over the area and we constructed layers using the grid analysis of Arc/info. The constructed layers were turned out to be similar to the geologic structure confirmed from the drilling data and we concluded that the methodology adopted in this study would be applicable to hydrogeologic model setup as a tool of providing the basic input data.

  • PDF

Hydrogeologic Parameter Estimation by Using Tidal Method in a Fractured Rock Aquifer (단열암반 대수층에서 조석분석법을 이용한 수리상수 추정)

  • Shim Byoung Ohan;Chung Sang Yong
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.3
    • /
    • pp.27-32
    • /
    • 2004
  • The oceanic tides have an effect on groundwater levels in coastal fractured rock aquifers. The observed groundwater table fluctuations caused by the effective stress through an aquifer are shown as sine curves similar with tidal fluctuation. To estimate a hydrogeologic parameter, tidal method is utilized with groundwater level fluctuations of two monitoring wells. Cross correlation function is used to calculate time lags between observed groundwater levels and tide, and the deeper well shows longer time lag. The storage coefficients calculated by using tidal efficiency and time lag show large differences. The storage coefficients obtained by using time lags are close to the result of slug test, and that of the deeper well shows closer value by slug test. The tidal efficiency is unsatisfied to apply in the tidal method because of an effect of phreatic aquifer and the vertical flow of groundwater through fractured confining bed. This tidal method can be an economical and effective way to define the parameter by considering the location of observation well and hydrogeologic characteristics of a coastal aquifer.