• Title/Summary/Keyword: Hydrogen sulfide

Search Result 593, Processing Time 0.024 seconds

Analysis of halitosis components following by subjective cognition of halitosis and oral state (주관적인 구취인식도와 구강환경에 따른 구취성분과의 관계 분석)

  • Shin, Kyoung-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.2
    • /
    • pp.263-275
    • /
    • 2011
  • Objectives : This study was performed analysis of Halitosis components following by subjective cognition of halitosis and Oral State in order to provide basic data for halitosis prevention and establish a device to efficiently eliminate halitosis and analyze the factors that affect the halitosis. Methods : 80 adults were participated who visited at the Dental Clinic in Kyoung-gi do, on the period of the March to September in 2010. The obtained results, through the oral examination, halitosis check and interview, Individually, were as followings. Results : According to the ammonia level was a high relationship between sex, CPI, Tongue plaque, DMFT index which were statistically significant (p<0.05). Total oral gas level was a relationship between VAS, tongue plaque, DMFT index(p<0.05). The Correlation coefficient between the Hydrogen sulfide level and Methyl mercaptan was estimated as r=0.534(p<0.01). As for the multiple regression analysis result, there have been selected dimethyl sulfide and Tongue plaque, Gingival index as factors affecting Bridge, Methyl mercaptan level is as factors affecting Hydrogen sulfide level. Conclusions : There was relationship between the periodontal disease and Ammonia gas component, hydrogen sulfide, dimethyl sulfide, methyl mercaptan. Which were statistically significant total oral gas level and oral variables. Such dental caries as the prevention or early treatment of periodontal disease.

A study of the sulfide stress corrosion cracking characteristic of A106 Gr B steep pipe weldment (황화수소환경에서 A106 Gr-B 강 용접부의 응력부식균열 특성 평가)

  • Lee, Gyu-Young;Park, Kwang-Jin;Bae, Dong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.114-119
    • /
    • 2007
  • Sulfide stress cracking (SSC) of materials exposed to oilfield environment containing hydrogen sulfide $(H_{2}S)$ has been recognized as a materials failure problem. Laboratory data and field experience have demonstrated that extremely low concentration of $H_{2}S$ may be sufficient to lead to SSC failure of susceptible materials. In some cases, $(H_{2}S)$ can act synergistically with chlorides to produce corrosion and cracking failures. SSC is a form of hydrogen embrittlement that occurs in high strength steels and in localized hard zones in weldment of susceptible materials. In the heat-affected zones adjacent to welds, there are often very narrow hard zones combined with regions of high residual stress that may become embrittled to such an extent by dissolved atomic hydrogen. On the base of understanding on sulfide stress cracking and its mechanism, SSC resistance for the several materials, those are ASTM A106 Gr B using in the oil industries, are evaluated.

  • PDF

Electrochemical Properties of Lithium Batteries with Nickel Sulfide by Ammonium Polysulfide (다황화암모늄에 의해 제조된 황화니켈을 이용한 리튬전지의 전기 화학적 특성 평가)

  • RYU, HO SUK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.6
    • /
    • pp.612-617
    • /
    • 2021
  • In the case of a metal sulfide electrode, it is used as an anode or cathode active material in a lithium battery. The reason is that the voltage exists between 0.8 and 2.0 V via lithium electrode and the discharge and charge capacity is high. In order to manufacture nickel sulfide for electrode, which are widely used, nano-nickel powder was sulfided using ammonium polysulfide, and single-phase NiS electrodes were manufactured through heat treatment. The prepared NiS electrode had a high initial capacity of 500 mAh/g or more, and was stabilized after 20 cycles to maintain a capacity of 400 mAh/g or more until 100 cycles.

Effects of Hydrogen Sulfide and Siloxane on Landfill Gas Utility Facilities

  • Nam, Sang-Chul;Hur, Kwang-Beom;Lee, Nam-Hoon
    • Environmental Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.159-164
    • /
    • 2011
  • This study examined the emission characteristics of impure gas-like hydrogen sulfide and siloxane contained in landfill gas (LFG) and investigated the effect of impure gas on LFG utility facilities. As a result of an LFG component analysis from eight landfills in the same environment, hydrogen sulfide averaged 436 ppmv (22-1,211 ppmv), and the concentration of total siloxane averaged 7.95 mg/$m^3$ (1.85-21.18 mg/$m^3$). In case of siloxane concentration by component, the ratio of D4 (average 3.79 mg/$m^3$) and D5 (average 2.64 mg/$m^3$) indicated the highest level. Different kinds of scales were found on the gas air heater (GAH) and inside the boiler. The major component of scale from the GAH was $Fe_2O_3$ of 38.5%, and it was caused by hydrogen sulfide. Other scale was found on the bottom and the wall of the boiler and the scale was silicon dioxide of 92.8% and 98.9%. The silicon dioxide scale was caused by combustion of siloxane. As a result of a scanning electron microscopy analysis, the structure of the silicon dioxide scale from the boiler was an immediate filamentous type. Consequently, as silicon dioxide scale is bulky, such bad effects were worsening, as an interruption in heat conduction, increase in fuel consumption, damage to the boiler by overheating, and clogged emission pipeline could occur in LFG utility facilities.

Estimation of Ultimate Methane and Hydrogen Sulfide Yields for C&D Waste and MSW Using BMP Test (건설폐기물, 생활폐기물의 용출특성 분석과 BMP test를 통한 최종메탄(CH4) 및 황화수소(H2S) 수율 산정)

  • Jung, Sukyoung;Jeong, Seongyeob;Chang, Soonwoong
    • New & Renewable Energy
    • /
    • v.10 no.1
    • /
    • pp.30-40
    • /
    • 2014
  • The main object of this study was to offer information about incoming waste in landfill and to evaluate biochemical methane and hydrogen sulfide potentials of landfill wastes. We examined brick, soil, mixed waste (C&D waste and MSW) samples for the study. The leaching experiments showed that BOD, COD and sulfate were determined in the range of 0~18,816 mg/kg, 85~21,100 mg/kg and 160~1,205 mg/kg, respectively in 6hr extraction test. An accumulated extraction tests for 140day were determined BOD 226~197,219 mg/kg, COD 436~242,588 mg/kg and Sulfate 1,090~25,140 mg/kg. Also, BMP (biochemical methane potential) tests were carried out to examine methane and hydrogen sulfide yields for the 3 different wastes. As a result, methane yield was determined to 262.68 mL $CH_4/g$ VS of MSW and 0~17.75 mL $CH_4/g$ VS in brick, soil and C&D waste. Higher hydrogen sulfide yield was observed to 0.079mL $H_2S/g$ VS in C&D waste. This result indicate that brick and soil could be sources of sulfate, and higher production of hydrogen sulfide could be odor problem and inhibitor of methane production.

Effect of General Ventilation Rate on Concentrations of Gaseous Pollutants Emitted from Enclosed Pig Building (밀폐형 돈사 작업장의 전체 환기율이 가스상 오염물질 노출 농도 변화에 미치는 영향)

  • Kim, Ki Youn;Seo, Sung Chul;Choi, Jeong-Hak
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.46-51
    • /
    • 2014
  • Objectives: The principal aim of this study was to compare the concentrations of gaseous pollutants emitted in enclosed pig buildings between different rates of general ventilation and determine the variations in the patterns of gaseous pollutants as affected by ventilation rate. Materials and Methods: The experiment was performed in the growing/finishing room($20.0m{\times}12.0m{\times}3.0m$) of a pig confinement building located on the experimental farm of Seoul National University. The conditions of the general ventilation rate for three treatments were 30%($4.12m^3s^{-1}$), 50%($6.87m^3s^{-1}$) and 70%($9.61m^3s^{-1}$). The data presented in the study were collected overa total of 45 days, 15 days for each of the three treatments from March to May 2011. A total of six air samplings were taken at 1.5m above the floor of the pig building. The environmental agents measured in the pig building were ammonia, hydrogen sulfide and odor concentration index for gaseous pollutants with temperature and hydrogen sulfide for thermal factors. Results: There were significant differences in the ammonia and odor concentration index in the pig building among the three general ventilation rate conditions(p<0.05), whereas hydrogen sulfide did not show a significant difference among three conditions of general ventilation rate(p>0.05). As the general ventilation rate applied to the pig building increases, it appears that all the indoor environmental agents measured in this study simultaneously decrease. Conclusions: The gaseous pollutants significantly affected by the general ventilation rate in pig building were ammonia and odor concentration index(p<0.05). However, it was found that hydrogen sulfide and thermal factors, temperature and relative humidity were not influenced significantly by variation in the general ventilation rate.

Literature review of the Reduction of Hydrogen Sulfide and Ammonia in Livestock Pen: Comparison between Korean and Chinese cases (축사 내 황화수소와 암모니아의 저감방안 고찰: 한중비교)

  • Yan, Ding;Moon, Chan-Seok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.4
    • /
    • pp.442-451
    • /
    • 2019
  • Objectives: The aim of this study was to review the reduction methods for ammonia (NH3) and hydrogen sulfide (H2S) exposure in livestock. Methods: By reviewing domestic and international research reports from Korea and China, reducing ammonia and hydrogen sulfide in livestock pens was analyzed in terms of ventilation, deodorant, and feed additives. In addition, exposure limits in Korea and China were examined through a comparison between 'TLV-TWA and STEL under the Industrial Safety and Health Act in Korea' and 'Management Standards for Air of Livestock Pens in China'. Results and Discussion: In order to effectively control hazardous gases and odors in livestock pens, the enhancement of natural ventilation or the addition of ventilation fans at the pollution source are being examined. Deodorants are used as adsorbents or masking deodorants. Additives to feed were zeolite powder, FeSO4·7H2O, enzymes, and microbial preparations. Use of feed additives was low-cost and had significant effects compared to other methods. Zeolite was the most commonly used in feed additive in Chinese cases and proved to be low-cost and effective for reducing harmful gases. Enzyme preparations were shown to stimulate the growth of livestock, but were expensive. Conclusions: This study reviewed and examined domestic and international research papers in Korea and China for reducing ammonia and hydrogen sulfide concentrations in livestock pens. More diverse research and the development of feed additives are needed.

Role of Plant Extracts to Remove Hydrogen Sulfide in the Air-Lifter Reactor (Air-lift 반응기내 황화수소제거시 식물정유추출물의 역할)

  • Park, Jong-Woo;Park, Young-G.;Kim, Jeong-In
    • KSBB Journal
    • /
    • v.25 no.5
    • /
    • pp.421-428
    • /
    • 2010
  • This paper reports on the experimental investigation carried out to evaluate the physical optimal conditions in the absorption column to remove odorous hydrogen sulfide gas. Hydrogen sulfide gas, as a highly undesirable contaminant, is most widely emitted from environmental treatment facilities. The absorbent mixed with natural second metabolites extracted from conifer trees and chemical absorbent of 2-aminoethanol was applied to remove it via chemical neutralization. The absorbent of natural second metabolites was achieved by a removal efficiency of 20-40% by itself depending on the treatment conditions, but the complex absorbent mixed with 0.1% amine chemical provides the removal efficiency of 98%. The optimal removal efficiencies have been examined against the two major parameters of temperature and pH. This study shows that the aqueous solution by natural second metabolites can be used as an appropriate absorbent in the column absorbed for the removal of hydrogen sulfide gas.

3상 생물막유동층반응기를 이용한 황화수소와 암모니아의 동시제거

  • Park, Jin-Su;Mun, Jong-Hye;Kim, Jong-U;Kim, Dong-Uk;O, Gwang-Jung
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.339-342
    • /
    • 2000
  • A three phase fluidized bed bioreactor including Thiobacillus sp.IW was used to remove hydrogen sulfide and ammonia simultaneously. In this study, hydrogen sulfide was oxidized to sulfate by the microorganism and ammonia was reacted with the sulfate to form ammonium sulfate. Removal efficiency of hydrogen sulfide was almost perfect up to 45 mg/l h of inlet loading rate, whereas that of ammonia was reduced as inlet loading rate increased from 10 mg/1 h.

  • PDF

A Study on Correlation of Odorous Compounds and Odor Substance occurring in Septic Tank and Sewer Pipe (하수관거 및 정화조에서 발생하는 악취물질이 복합악취에 미치는 영향에 관한 연구)

  • Song, Homyeon;Cho, Jeongil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.165-175
    • /
    • 2013
  • This study aims to analysis correlation in septic tank and sewer pipe between odor substances and complex odor. For the analysis, convert odor substances to odor intensity, and estimate the effect of odor substances on complex odor. As a result, both Hydrogen sulfide and Methyl mercaptane of specified offensive odor substances accounted for 29 percent of the effect of odor substances on complex odor. Hydrogen sulfide and Methyl mercaptane are major cause of odor from septic tank and sewer pipe. The result of this study is suggested to be used as a preliminary data for research on analysis complex odor and odor substances.