Effect Analysis of the Pre-Consulting System of Hydrogen Refueling Station for Expanding the Hydrogen Mobility Infrastructure (수소모빌리티 인프라 확대를 위한 수소충전소 사전컨설팅 제도 효과 분석)

  • Lee, Man-Wook;Kim, Sung-Kyu;Tak, Song-Su;Kim, Dae-Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.85-91
    • /
    • 2021
  • In January 2019, the Korean government announced the 「Hydrogen Economy Activation Roadmap」 to be a world-class leading country in Hydrogen economy. Korea has established a strategy that can lead the hydrogen economy with its strong points of 'hydrogen car' and 'fuel cell'. As a part of that, a target of supplying hydrogen vehicle charging stations to 310 by 2022 and 1,200 by 2040 was established. In line with this, Korea Gas Safety Corporation will operate a pre-consulting system of hydrogen vehicle charging station in February 2021 to solve in advance construction delays due to various on-site problems according to safety standards during the construction stage to build a hydrogen refueling station with a sense of speed. This paper is to find out about the pre-consulting system and to analyze its effects.

The Study of Comparison of Cooling System for H2 Discharge Station (수소충전용 직접 및 간접 냉각시스템 비교 평가 연구)

  • LEE, HYENCHAN;YI, JONGYEOL;BAE, CHANHYO;HEO, JEONGHO;JEON, JAEYOUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.2
    • /
    • pp.163-169
    • /
    • 2019
  • This study is a research to compare efficiency of new cooling system (chiller, pre-cooler) to that of the conventional system at the hydrogen refueling station (HRS). This study includes contents for thermodynamic comparison of cooling system for HRS and comparison of pros and cons of its components. So It is to establish design concept of cooling system of HRS supplying with fuel cell electric vehicle (FCEV). HRS is charging high pressure H2 (700 bar) to FCEV. However cooling system is need to prevent temperature rise in tank. This cooling system consists of pre-cooler and chiller system.

Risk Assessment for Performance Evaluation System of Hydrogen Refueling Station (수소충전소 성능평가 장비 안전성 평가 연구)

  • KANG, SEUNGKYU;LEE, DONGHOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.3
    • /
    • pp.232-239
    • /
    • 2022
  • This study performed qualitative and quantitative risk assessment of equipment for evaluating the protocol of hydrogen refueling stations and suggested measures to improve safety. Hazard and operability study was performed for qualitative risk assessment, and Hy-KoRAM was used for quantitative risk assessment. Through a qualitative risk assessment, additional ventilation devices were installed, simultaneous venting of the storage container was prohibited, and the number of repeated refilling of the evaluation equipment was identified to manage the number of fillings of the container. Through quantitative risk assessment, the area around the device was set as a restricted area when evaluating the station, and measures were suggested to reduce the frequency of accidents.

Current Status of Standardization for Quality Control of Hydrogen Fuel in Hydrogen Refueling Stations for Fuel Cell Electric Vehicles (수소충전소 내 연료전지용 수소연료 품질 관리 및 표준화 동향)

  • KIM, DONGKYUM;LIM, JEONG SIK;LEE, JEONGSOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.4
    • /
    • pp.284-292
    • /
    • 2022
  • Hydrogen is promising a candidate for energy supporting the carbon neutrality policy for greenhouse gas reduction, which is being promoted in several countries, including Korea. Although challenging efforts-such as lowering the costs of green hydrogen production and fuel cells-remain, hydrogen fuel cell electric vehicles (FCEVs) are expected to play a significant role in the energy transition from fossil fuels to renewable energy. In line with this objective, the hydrogen FCEV working group in the International Organization for Standardization (ISO) compiled and revised international standards related to hydrogen refueling stations as of 2019. A well-established hydrogen quality management system based on the standard documents will increase the reliability of hydrogen charging stations and accelerate the use of FCEVs. In this study, among the published ISO standards and other references, the main requirements for managing charging stations and developing related techniques were summarized and explained. To respond preemptively to the growing FCEV market, a continuous hydrogen quality monitoring method suitable for use at hydrogen charging stations was proposed.

Status of the Real-time Safety Monitoring System of Hydrogen Refueling Station According to the Operation (수소충전소 실시간 이중 모니터링 시스템 운영을 통한 안전성 향상)

  • Lee, Jin-Woo;Park, Jong-Hee;Kim, Dae-Hyun;Tak, Song-Su;Yang, Byung-Jo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.92-97
    • /
    • 2021
  • In accordance with the revision of the Enforcement Regulations of the High-Pressure Gas Safety Management Act in February 2021, from August 27, 2021, the operation status of safety devices such as gas leak detection and alarm devices, emergency shut-off devices and flame detectors installed at hydrogen vehicle charging stations can be monitored in real time. It is transmitted and operated by the computer system managed by Korea Gas Safety Corporations. We intend to share the results of statistical analysis of abnormal signals that have occurred along with the results of the monitoring system construction so that they can be used for the safety management of hydrogen refueling stations, and to seek future safety management directions.

A Study on the Optimal Location Selection for Hydrogen Refueling Stations on a Highway using Machine Learning (머신러닝 기반 고속도로 내 수소충전소 최적입지 선정 연구)

  • Jo, Jae-Hyeok;Kim, Sungsu
    • Journal of Cadastre & Land InformatiX
    • /
    • v.51 no.2
    • /
    • pp.83-106
    • /
    • 2021
  • Interests in clean fuels have been soaring because of environmental problems such as air pollution and global warming. Unlike fossil fuels, hydrogen obtains public attention as a eco-friendly energy source because it releases only water when burned. Various policy efforts have been made to establish a hydrogen based transportation network. The station that supplies hydrogen to hydrogen-powered trucks is essential for building the hydrogen based logistics system. Thus, determining the optimal location of refueling stations is an important topic in the network. Although previous studies have mostly applied optimization based methodologies, this paper adopts machine learning to review spatial attributes of candidate locations in selecting the optimal position of the refueling stations. Machine learning shows outstanding performance in various fields. However, it has not yet applied to an optimal location selection problem of hydrogen refueling stations. Therefore, several machine learning models are applied and compared in performance by setting variables relevant to the location of highway rest areas and random points on a highway. The results show that Random Forest model is superior in terms of F1-score. We believe that this work can be a starting point to utilize machine learning based methods as the preliminary review for the optimal sites of the stations before the optimization applies.

Hydrogen Industry Cycle Infrastructure Safety Analysis (수소산업 전주기 인프라시설 안전성 분석)

  • WOOIL PARK;SEULKI CHOI;INWOO LEE;SEUNGKYU KANG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.795-802
    • /
    • 2022
  • Korea is showing its appearance as a leading country in the hydrogen economy by establishing policies for revitalizing the hydrogen economy and enacting the 「Hydrogen Economy Promotion and Hydrogen Safety Management Act」 for the first time in the world. In addition, domestic hydrogen facilities are using hydrogen energy safely through world-class safety management compared to overseas advanced countries. However, in order to enhance the safety of the rapidly diversifying hydrogen industry and rapid technology development, such as the introduction of liquefied hydrogen, some institutional improvements are needed. In this regard, this paper intends to analyze the results of safety inspections on 13 representative facilities and prepare safety improvement plans to establish preemptive safety measures.

A Study on a Combined DMFC-Lithium Battery Hybrid System for a Forklift (지게차용 DMFC와 리튬배터리 하이브리드시스템의 혼합 적용에 대한 연구)

  • Ju, Yong-Soo;Lim, Dong-Jin;Kim, Hong-Gun;Kwac, Lee-Ku
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.4
    • /
    • pp.57-65
    • /
    • 2021
  • This paper explains a DMFC-Lithium Battery hybrid system applied to a forklift. A conventional Lead Acid battery forklift has several problems: long charging times, short operation times, and frequent battery replacements. As a result, hydrogen-powered forklifts are replacing Lead acid battery-powered forklifts due to their shorter refueling time and longer operation times. However, in doing so, we are confronted with the problem of a high hydrogen refueling infrastructure. A Direct Methanol Fuel Cell (DMFC), on the other hand, is an eco-friendly generator that directly converts the chemical energy of methanol into electricity. In general, DMFC is regarded as a small power generator under kW power. In this paper, a DMFC-Battery hybrid system is applied to a 1.5 ton forklift by increasing the power output of the DMFC stack and utilizing the high charge-discharge characteristics of a lithium battery.

A Study on Taxonomy and RCM Strategy Establishment for Performance Evaluation of Hydrogen Compression System at Hydrogen Vehicle Refueling Stations (수소자동차충전소의 수소압축장치 성능평가를 위한 분류체계 및 RCM 전략수립 연구)

  • Seong-jun Bae;Ha-neul Yim;Seo-yeon Na;Chung-keun Chae;Jin-hyeok Choi;Jin-woo Lee;Sang-bong Shin
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.48-56
    • /
    • 2023
  • Currently, Hydrogen compressor is maintained and managed according to the safety management regulations of the operator. But it is not based on technical standards, so it is necessary to establish based on reliability. In this paper, hydrogen compressor taxonomy by ISO 14224 standard reviewed for hydrogen compressor operated by KOGAS-Tech hydrogen vehicle refueling station to establish 9-stage taxonomy, and FMEA was conducted to establish RCM strategy specified in SAE JA1011, and 1012. It is expected that results of taxonomy and RCM strategy will be used as basic data for development of standards for verifying the performance of compressors.

A Study on the Safety Enhancement of Hydrogen Tube Trailer (수소운송설비 안전성 강화 방안 고찰)

  • Woo-Il, Park;Yeong-Hun, Kim;In-Woo, Lee;Seung-Kyu, Kang
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.59-64
    • /
    • 2022
  • Currently, 787 hydrogen tube trailer are in operation as of the end of October 2022, and a maximum of 340 kg is transported in a Type 1 seamless container at a pressure of up to 200 bar. The current safety management system and facility management are in good condition, but the system and facility structure improvement are needed to strengthen safety. Accordingly, this paper simulated and analyzed an accident case that occurred on the Daejeon-Dangjin highway on December 28, 2021 during the process of expanding the supply and operation of hydrogen tube trailer according to the hydrogen energy activation policy. Based on the results, suggestions were made on how to improve the safety of hydrogen tube trailer.