• 제목/요약/키워드: Hydrogen ion selective electrode

검색결과 12건 처리시간 0.024초

Tribenzylamine Ionophore를 이용한 pH-ISE의 제조 및 임상응용 (Preparation and Clinical Application of pH-ISE(Ion Selective Electrode) Based on Tribenzylamine Ionophore)

  • 조동회;박정오
    • 대한임상검사과학회지
    • /
    • 제38권1호
    • /
    • pp.59-64
    • /
    • 2006
  • The pH-ISE(ion selective electrode) based on tribenzylamine as a hydrogen ion carrier was prepared and its electrochemical characterization was studied. It responded linearly to hydrogen ions in the range of pH 3.1 - pH 11.0 and the Nernstian slope showed 55.0 mV/pH (at $20{\pm}0.2^{\circ}C$), it also showed a fast response time of 8 sec. When it was directly applied to human blood(pH 6.0-8.5), we could get the same satisfying results. A good reproducibility and stability were shown with the precision of 2 mV (${\pm}0.1$). The pH-ISE based on tribenzylamine exhibited biocompatibility in clinical applications.

  • PDF

Surface Renewable Hydrogen Ion-Selective Polymeric Composite Electrode Containing Iridium Oxide

  • Quan, Hongmei;Kim, Won;Chung, Koo-Chun;Park, Jong-Man
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권10호
    • /
    • pp.1565-1568
    • /
    • 2005
  • A surface renewable pH electrode was prepared by utilizing composite electrode technique. Iridium oxide micro-fine particles was prepared by hydrolysis of $(NH_4)_2IrCl_6$ at elevated temperature. The iridium oxide particles were mixed with well-dispersed carbon black and then filtered. The mixture was suspended in DMF containing PVC as a binder. The mixture was precipitated rapidly by adding large amount of water. The precipitate was ground and pressure-molded to iridium oxide composite electrode material. The electrode showed linear response between pH 1-13 with 50 to 60 mV/pH slope. The electrode maintained the pH response without appreciable slope drift for 170 days if stored in deionized water. The electrode surface can be renewed reproducibly by simple grinding process whenever contaminated or deactivated.

Bakelite A-Ni(II) 착물의 질산이온 선택성 막전극 (Nitrate Ion-Selective Membrane Electrode Based on Complex of Ammonia Modified Bakelite A-Ni(II) Nitrate)

  • 김환기;신두순
    • 대한화학회지
    • /
    • 제31권3호
    • /
    • pp.271-279
    • /
    • 1987
  • Amine기를 가진 Bakelite A와 Ni(II) 사이의 착물을 이용한 ${NO_3}^-$이온 선택성 막전극을 만들었다. 이 막전극은 $H^+$ 이온 및 2가 3가 음이온에는 감응하지 않으며, 특히 이 막전극의 재현성, 감응시간 및 이온선택성등 전기화학적 성질을 조사하여 다른 실용화된 막전극과 비교 고찰하였으며 분석화학에의 응용을 고찰하였다.

  • PDF

N,N,N,N-Tetrabenzylethylenediamine 중성운반체를 이용한 수소 이온 선택성 막전극 (A hydrogen ion-selective membrane electrode based on N,N,N,N-Tetrabenzylethylenediamine as neutral carrier)

  • 정성숙;박면용;정구춘;조동회;이경재;김재우
    • 분석과학
    • /
    • 제8권2호
    • /
    • pp.187-193
    • /
    • 1995
  • N,N,N,N-Tetrabenzylethylenediamine 중성운반체를 이용하여 PVC 수소이온 선택성 막전극을 제조하였다. 가소제 종류(phthalates와 sebacate) 및 친지방성 첨가제(NaTPB)에 따른 막전극의 전기저항과 수소이온 감응범위 및 알칼리금속과 알칼리토금속의 존재하에서 방해효과를 조사하였다. 가소제 종류에 의한 전기저항은 영향을 거의 받지 않았고 NaTPB 0.7%의 경우 수소이온에 대한 Nernstian 기울기는 가장 이론값에 근접하였으며, 또한 알칼리금속 및 알칼리토금속에 의한 방해도 적게 받았다. pH-선택성 고분자 막전극은 pH 2~10 범위내에서 선형적이고, 산과 알칼리용액 중에서 안정성 및 재현성 시험 결과 매우 좋게 나타났다.

  • PDF

ISFET Glucose Sensor with Palladium Hydrogen Selective Membrane

  • Chung, Mi-Kyung;Kim, Seong-Wan;Lee, Sang-Sik;Park, Chong-Ook
    • 센서학회지
    • /
    • 제21권2호
    • /
    • pp.90-95
    • /
    • 2012
  • This paper describes the development of a glucose biosensor based on ion sensitive field effect transistor(ISFET) with a palladium(Pd) modified ion sensing membrane. By adopting Pd as a hydrogen sensitive layer and integrating a screen-printed reference electrode, the sensitivity and stability were considerably improved due to the high permeability and selectivity of the Pd hydrogen selective membrane. This paper suggests a new approach for realizing portable and highly sensitive glucose sensors for diagnosing and treating diabetes mellitus.

The Potentiometric Studies on the Effects of Various Functional Groups in Disiloxane as an Anion-Selective Ionophore

  • Jung, Hyo-Jin;Lee, Myong-Euy;Lim, Chae-Yun;Paeng, Ki-Jung
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권1호
    • /
    • pp.57-62
    • /
    • 2005
  • The potentiometric responses for various anions are investigated with membrane electrode (membrane 1) based on 1,3-diethyl-1,3-dihydroxy-1,3-bis(2-dimethylaminomethyl ferrocenyl) disiloxane. The nitrate ion-selective electrode based on compound 1 gave a good Nernstian response of 58.18 mV per decade for nitrate with the detection limit of −e5.66 of log [NO3−e]. Compound 1 has all those functional groups and the other two compounds have less functional group of ferrocenyl or ferrocenyl and hydroxide, respectively. Even though, potentiometric response to anions was excellent at pH 5, the selectivity pattern for all three membrane electrode based on series of disiloxane is almost like Hofmeister sequence at pH 5. However, the membrane electrode 1-3 exhibited very different response to anions at pH 7. In this pH, NH2 is not protonated and ionophore may act as neutral carrier. Hydrogen bond may enhance the responsibility to hydrogen acceptors and intramolecular electro-active site may increase the permeability of analyte to ionophore in membrane.

아릴아민계의 중성운반체를 이용한 수소이온선택성 막전극 (Hydrogen ion-selective membrane electrodes based on arylamines as neutral carriers)

  • 정성숙;조동희;김재우;정구춘;박면용
    • 분석과학
    • /
    • 제9권1호
    • /
    • pp.78-83
    • /
    • 1996
  • Tribenzylamine(TBA), tetrabenzylethylenediamine(TBEDA), pentabenzyldiethylenetriamine(PBDETA)을 중성운반체로 이용한 막전극은 각각 pH 1~pH 9, pH 2~pH 12, pH 4~pH 12 범위에서 수소이온에 선택적이고 선형적인 감응을 나타내었다. TBA, TBEDA, PBDETA로 만든 막전극은 비공유전자쌍 수의 증가와 수소이온 선택성 사이에는 무관 하였고 각각에 대한 기울기는 43.8mV/pH, 46.9mV/pH, 43.6mV/pH를 나타냈다. 각 전극에 대하여 알칼리금속이온($Li^+$, $Na^+$, $K^+$) 및 알칼리토금속이온($Ba^{2+}$, $Ca^{2+}$, $Mg^{2+}$), 전이금속이온($Mn^{2+}$, $Co^{2+}$, $Ni^{2+}$, $Cu^{2+}$, $Zn^{2+}$)에 대한 방해이온을 측정하였다. 선택계수는 분리용액법을 이용하여 측정하였고 TBEDA를 이용한 막이 가장 좋은 결과를 나타내었다.

  • PDF

溶解氣體 分析用 氣體感應膜 이온選擇性 電極 (第 3 報). 새로운 管形 PVC膜 질산이온 選擇性 電極을 이용한 아질산이온의連續·自動化 定量 (Gas-Sensing Membrane Electrodes for the Determination of Dissolved Gases (III). Continuous-Automated Determination of Nitrite Ion Using a New Tubular PVC Membrane Type of Selective Electrode Nitrate)

  • 이흥락;윤종훈
    • 대한화학회지
    • /
    • 제35권1호
    • /
    • pp.51-58
    • /
    • 1991
  • 새로운 管形 PVC膜 질산이온 選擇性 電極을 제작하여 그 性能을 조사하였다. 電極膜의 組成을 5${\%}$ aliquat-NO$_3$ 용액+ 32${\%}$ poly(vinyl chloride) + 63${\%}$ dibutyl sebecate로 하였을 때 전극의 感應特性이 최적이었으며, 이 때의 감응기울기는 58.5 ${\pm}$ 0.1 mV/decade, 檢出限界는 0.02mM, 感應時間 (t$_{99}$)은 25초이었다. 이 전극을 써서 아질산이온을 連續${\cdot}$自動化法으로 정량하였다. Recipient 용액은 pH 7.6의 10$^{-2}$ M 燐酸鹽 緩衝溶液을 쓰고, 여기에 酸化劑로서 過酸化水素를 0.3${\%}$가 되도록 포함시켰다. 전극계의 最適條件에서 아질산이온 標集溶液 8.0 ${\times}$ 10$^{-5}$ M ∼ 5.0 ${\times}$ 10$^{-2}$ M의 범위에서 직선적인 감응을 나타내었으며, 이 때의 감응기울기는 56.8 ${\pm}$ 0.2 mV/decade이었다.

  • PDF

Tetrabenzylalkylenediamine을 이용한 수소이온 선택성 막전극 (Hydrogen ion-selective membrane electrodes based on tetrabenzylalkylenediamine)

  • 김재우;조동희;정성숙;정구춘;박면용
    • 분석과학
    • /
    • 제10권3호
    • /
    • pp.161-167
    • /
    • 1997
  • Tetrabenzylmethylenediamine(TBMDA), tetrabenzylethylenediamine(TBEDA), tetrabenzylpropylenediamine(TBPDA), tetrabenzylhexylenediamine(TBHDA)의 중성운반체를 이용한 수소이온 선택성 막전극을 제조하였다. TBMDA, TBEDA, TBPDA, TBHDA의 아미노기간의 탄소수 변화에 따라 pH 1~pH 9, pH 2~pH 9, pH 3~pH 9, pH 4~pH 9 범위에서 수소이온에 대하여 선택적이고 선형적인 감응을 나타내었으며, 각각에 대한 기울기는 48mV/pH, 52mV/pH, 64mV/pH, 59mV/pH를 나타내었다. 각 전극에 대하여 알칼리금속이온($Li^+$, $Na^+$, $K^+$) 및 알칼리토금속이온($Mg^{2+}$, $Ca^{2+}$, $Sr^{2+}$, $Ba^{2+}$), 전이금속이온($Cu^{2+}$, $Ni^{2+}$, $Co^{2+}$)과 음이온($I^-$, $Br^-$, ${NO_3}^-$, $SCN^-$)에 대한 방해효과를 측정하였다. 선택계수는 분리용액법을 이용하여 측정하였고, 산성 용액에서 선형성을 나타내는 TBMDA가 가장 좋은 결과를 나타내었다.

  • PDF

구미 불산 누출사고 지점 주변 식물의 불소화합물 농도 분포 및 공기 중 불화수소 농도 추정에 관한 연구 (Study on the Distribution of Fluorides in Plants and the Estimation of Ambient Concentration of Hydrogen Fluoride Around the Area of the Accidental Release of Hydrogen Fluoride in Gumi)

  • 구슬기;최인자;김원;선옥남;김신범;이윤근
    • 한국환경보건학회지
    • /
    • 제39권4호
    • /
    • pp.346-353
    • /
    • 2013
  • Objectives: The goal of this study is to identify the distribution of the foliar fluorine content of vegetation surrounding the area where hydrofluoric acid was accidently released in Gumi, Gyeongsangbuk-do on September 27, 2012. In addition, it also aims to estimate the concentration of hydrogen fluoride in the air on the day of the accident. Methods: Samples of plant leaves were collected on October 7, 2012 within 1 km from the site where the accident occurred. These samples were analyzed for soluble fluorine ion with an ion selective electrode. The ambient concentration of hydrogen fluoride was calculated using the fluoride content in the plant via the dose-rate equation (${\Delta}F$=KCT). Results: The arithmetic and geometric means of the concentrations were 2158.2 and 1183.7mg F $kg^{-1}$ for leaves and, 2.4 and 1.1 ppm HF for the air, respectively. The highest concentration of hydrogen fluoride in the air was 14.7 ppm, which is higher than the maximum concentration reported by the government (1 ppm) and the exposure limit (ceiling, 3 ppm). The concentrations of both fluorine and hydrogen fluoride decreased with increasing distance from the accident site and showed a significant decrease outside of a 500m radius from the site (p <0.05). Conclusions: The area around the accident site was highly polluted with hydrogen fluoride according to the results of this study. Considering the persistency of hydrogen fluoride in the environment, long-term monitoring and environmental impact assessment should be pursued.