• 제목/요약/키워드: Hydrogen detector

검색결과 42건 처리시간 0.027초

FID를 이용한 수중의 TOC 분석법 (Determination of Total Organic Carbon in Water by Flame Ionization Detector)

  • 박만기;한대석;임병연
    • 약학회지
    • /
    • 제22권3호
    • /
    • pp.157-162
    • /
    • 1978
  • Total organic carbon(TOC) can be determined by means of combustion and flame ionization detector. The principle of string method is that a sample acidified to pH2 and transferred into combustion tube by string is oxidized with air. Another combustion tube method is that organic compounds are oxidized in the combustion tube charged with CuO and cobalt asbestos after the acidified sample is injected directly by microsyringe. Carbon dioxide evolved was reduced under specially treated nickel catalyst and hydrogen, the methane produced was detected by flame ionization detector. Linear relationship was found between concentration and the peak height by the string method. The peak area in the case of combustion tube method is in the range of 1-200ppm. The coefficient of variation by string method was 2.3% and that by combustion tube method was 1.8%. The lower detectable limit was about 10mol. Advantages of the latter are simplicity, sensitivity and reproducibility. TOC in contineous stream can also be determined automatically by means of the string method.

  • PDF

Experimental setup for elemental analysis using prompt gamma rays at research reactor IBR-2

  • Hramco, C.;Turlybekuly, K.;Borzakov, S.B.;Gundorin, N.A.;Lychagin, E.V.;Nehaev, G.V.;Muzychka, A. Yu;Strelkov, A.V.;Teymurov, E.
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.2999-3005
    • /
    • 2022
  • The new experimental setup has been built at the 11b channel of the IBR-2 research reactor at FLNP, JINR, to study the elemental composition of samples by registration of prompt gamma emission during thermal neutron capture. The setup consists of a curved mirror neutron guide and a radiation-resistant HPGe high-purity germanium detector. The detector is surrounded by lead shielding to suppress the natural background gamma level. The sample is placed in a vacuum channel and surrounded by a LiF shield to suppress the gamma background generated by scattered neutrons. This work presents characteristics of the experimental setup. An example of hydrogen concentration determining in a diamond powder made by detonation synthesis is given and on its basis, the sensitivity of the setup is calculated being ~4 ㎍.

식품 중 과산화수소의 분석법에 관한 연구 (Studies on the Determination Method of Hydrogen Peroxide in Foods)

  • 이달수;이영자;박재석;권용관;황정연;이주연;이철원
    • 한국식품과학회지
    • /
    • 제34권6호
    • /
    • pp.998-1001
    • /
    • 2002
  • 신속하고 정확한 식품 중 과산화수소 분석방법을 확립하고자 물을 이동상으로 양이온수지칼럼에서 과산화수소를 분리한 후 전기화학검출기로 검출하는 Mico-LC법을 사용하였으며 여기에 사용한 전해질용액인 무수황산나트륨의 최적농도 및 검출기의 최적전압은 각각 50 mM, 0.6 V이었다. 본 Mico-LC 방법을 적용하여 국내 식품 중 토마토와 레몬에 대한 회수율을 검토한 결과 각각 98.3 및 97.4%이었으며, 국내유통식품 중 채소류 및 과실류 총 28종에 대하여 과산화 수소를 분석한 결과, 과실류인 바나나, 복숭아, 오렌지 및 딸기에서 각각 0.6, 0.5, 1.9 및 0.9 ppm, 채소류인 피망, 양파, 오이, 우엉 및 가지에서 각각 0.5, 0.6, 0.9, 0.8 및 0.4 ppm이 검출되었으며 나머지 19종은 모두 불검출이었다.

환경 대기 중 ppt 수준의 황화수소 분석을 위한 GC 방식의 검량 기법에 대한 연구 (Calibration Methods for the Gas Chromatographic Analysis of ppt-level Hydrogen Sulfide (H2) in Air)

  • 김기현;오상인;최여진;최규훈;주도원
    • 한국대기환경학회지
    • /
    • 제19권6호
    • /
    • pp.679-687
    • /
    • 2003
  • In this study, we investigated the analytical techniques to quantify the ambient concentration of hydrogen sulfide (H$_2$S) in air at ppt concentration level. For this purpose, an on-line GC analytical system equipped with both pulsed-flame photometric detector (PFPD) and thermal desorption unit (TDU) was investigated by collecting ambient air samples. The results of our study generally indicated that calibration conditions of GC system is highly sensitive to affect the accuracy of the analytical technique. Most importantly. we found that the use of different matrices in the the preparation stage of working standards was sensitive to control the overall performance of this technique. The calibration of our analytical system was tested by the two types of working standard (prepared by mixing either with high purity $N_2$ or with the ambient air). According to this test, the latter represented more efficiently the detecting conditions of actual air samples. The peak occurrence patterns of both air samples and standards (prepared by mixing with ambient air) were altered in a similar manner as the function of the loaded volume; however, it was not the case for the $N_2$-mixed standards. Results of our study suggest that detection of H$_2$S is highly different from other sulfides and that its quantification requires minimiaing interfering effects of non -pure substance (like water vapor) and (either sorptive or destructive) loss effects.

카드뮴 텔룰라이드 CMP 공정에서 산화제가 연마에 미치는 영향 (Effect of Oxidizer on the Polishing in Cadmium Telluride CMP)

  • 신병철;이창석;정해도
    • 한국정밀공학회지
    • /
    • 제32권1호
    • /
    • pp.69-74
    • /
    • 2015
  • Cadmium telluride (CdTe) is being developed for thin film of the X-Ray detector recently. But a rough surface of the CdTe should be improved for resolution and signal speed. This paper shows the study on the improvement of surface roughness and removal rate by applying Chemical Mechanical Polishing. The conventional potassium hydroxide (KOH) based colloidal silica slurry could not realize a mirror surface without physical defects, resulting in low material removal rate and many scratches on surface. In order to enhance chemical reaction such as form oxidized layer on the surface of cadmium telluride, we used hydrogen peroxide ($H_2O_2$) as an oxidizer. Consequently, in case of 3 wt% concentration of hydrogen peroxide, the highest MRR (938 nm/min) and the lowest surface roughness ($R_{p-v}=10.69nm$, $R_a=0.8nm$) could be obtained. EDS was also used to confirm the generated oxide of cadmium telluride surface.

Cross Talk Experiment with Two-element CdTe Detector and Collimator for BNCT-SPECT

  • Manabe, Masanobu;Ohya, Ryosuke;Saraue, Nobuhide;Sato, Fuminobu;Murata, Isao
    • Journal of Radiation Protection and Research
    • /
    • 제41권4호
    • /
    • pp.328-332
    • /
    • 2016
  • Background: Boron Neutron Capture Therapy (BNCT) is a new radiation therapy. In BNCT, there exists some very critical problems that should be solved. One of the severest problems is that the treatment effect cannot be known during BNCT in real time. We are now developing a SPECT (single photon emission computed tomography) system (BNCT-SPECT), with a cadmium telluride (CdTe) semiconductor detector. BNCT-SPECT can obtain the BNCT treatment effect by measuring 478 keV gamma-rays emitted from the excited state of $^7Li$ nucleus created by $^{10}B(n,{\alpha})$ $^7Li$ reaction. In the previous studies, we investigated the feasibility of the BNCT-SPECT system. As a result, the S/N ratio did not meet the criterion of S/N > 1 because deterioration of the S/N ratio occurred caused by the influence of Compton scattering especially due to capture gamma-rays of hydrogen. Materials and Methods: We thus produced an arrayed detector with two CdTe crystals to test cross talk phenomenon and to examine an anti-coincidence detection possibility. For more precise analysis for the anti-coincidence detection, we designed and made a collimator having a similar performance to the real BNCT-SPECT. Results and Discussion: We carried out experiments with the collimator to examine the effect of cross talk of scattering gamma-rays between CdTe elements more practically. As a result of measurement the coincidence events were successfully extracted. Conclusion: We are now planning to carry out evaluation of coincidence rate from the measurement and comparison of it with the numerical calculations.

소방 실화재 훈련에서 사용하는 압축목재 가연물에서 발생하는 유해물질 특성 (Characteristics of Hazardous Substances Generated from Combustible Compressed Wood Used during Live Fire Training for Firefighters)

  • 이용호;김진희;김의진;최원준;이완형;강성규;이소연;함승헌
    • 한국환경보건학회지
    • /
    • 제46권5호
    • /
    • pp.555-564
    • /
    • 2020
  • Objectives: To identify and investigate through qualitative and quantitative analysis the hazardous substances generated when compressed wood was burned at a live fire-training center. Methods: Four types of compressed wood that are actually used in live fire training were burned in a chamber according to KS F2271. The gaseous material was sampled with a gas detector tube and conventional personal samplers. Results: 1,3-butadiene, benzene, toluene, xylene, formaldehyde, hydrogen chloride, hydrogen cyanide, ammonia, carbon monoxide, and nitric acid were detected. In particular, 1,3-butadiene (497.04-680.44 ppm), benzene (97.79-125.02 ppm), formaldehyde (1.72-13.03 ppm), hydrogen chloride (4.71-15.66 ppm), hydrogen cyanide (3.64-8.57 ppm), and sulfuric acid (3.85-5.01 ppm) exceeded the Korean Occupational Exposure Limit as measured by sampling pump according to the type of compressed wood. Conclusions: We found through the chamber testing that firefighters could be exposed to toxic substances during live fire training. Therefore, firefighter protection is needed and more research is required in the field.

Development and Applications of TOF-MEIS (Time-of-Flight - Medium Energy Ion Scattering Spectrometry)

  • Yu, K.S.;Kim, Wansup;Park, Kyungsu;Min, Won Ja;Moon, DaeWon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.107.1-107.1
    • /
    • 2014
  • We have developed and commercialize a time-of-flight - medium energy ion scattering spectrometry (TOF-MEIS) system (model MEIS-K120). MEIS-K120 adapted a large solid acceptance angle detector that results in high collection efficiency, minimized ion beam damage while maintaining a similar energy resolution. In addition, TOF analyzer regards neutrals same to ions which removes the ion neutralization problems in absolute quantitative analysis. A TOF-MEIS system achieves $7{\times}10^{-3}$ energy resolution by utilizing a pulsed ion beam with a pulse width 350 ps and a TOF delay-line-detector with a time resolution of about 85 ps. TOF-MEIS spectra were obtained using 100 keV $He^+$ ions with an ion beam diameter of $10{\mu}m$ with ion dose $1{\times}10^{16}$ in ordinary experimental condition. Among TOF-MEIS applications, we report the quantitative compositional profiling of 3~5 nm CdSe/ZnS QDs, As depth profile and substitutional As ratio of As implanted/annealed Si, Ionic Critical Dimension (CD) for FinFET, Direct Recoil (DR) analysis of hydrogen in diamond like carbon (DLC) and InxGayZnzOn on glass substrate.

  • PDF

A Study on the Distribution Characteristics of Sulfur Compounds in Ambient air using Continuous Monitoring Method in Incheon Area

  • Seo, Seok-Jun;Lim, Yong-Jae;Hong, You-deok;Park, Geon-Young
    • 통합자연과학논문집
    • /
    • 제8권2호
    • /
    • pp.128-134
    • /
    • 2015
  • This paper focuses on the applicability of a continuous monitoring method on trace sulfur compounds in the ambient air by TD and GC/PFPD. The target compounds for monitoring include H2S(hydrogen sulfide), Methyl mercaptan, Dimethyl Sulfide, and Dimethyl disulfide. The result of QA/QC on monitoring instruments satisfies all the standards of Odor Measurement and Analysis Method, showing that the reproductivity of the compounds by concentration is within 10%, linearity is above 0.98 of a correlation efficient, method detection limit is 0.16 ppb by MM standard, and recovery rate is over 70%. Monitoring was conducted for two years from March 2006 to February 2008. As a result of the monitoring, the average concentration of H2S was 0.08 ppb, with the maximum concentration at 16.15 ppb. The result indicates that it is reasonable to do continuous monitoring as there appears a spontaneous event of high concentration by the condition of the site during monitoring odor-causing substances. Therefore, it is suggested that the continuous monitoring method used in this paper is appropriate to identify the characteristics of sudden occurrence and concentration variations of sulfur compounds.