• Title/Summary/Keyword: Hydrochloric acid.

Search Result 634, Processing Time 0.026 seconds

Characteristic of Hydrogen Generation from Solid-State NaBH4 and Fuel Cell Operation for Fuel Cell Aircraft (연료전지 항공기를 위한 고체상태 NaBH4의 수소발생 및 연료전지 구동 특성)

  • Lee, Chung-Jun;Kim, Tae-Gyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.9
    • /
    • pp.858-865
    • /
    • 2011
  • This paper describes the characteristics of hydrogen generation from solid-state $NaBH_4$ and fuel cell operation for fuel cell aircraft. The solid-state $NaBH_4$ was used for a high hydrogen storage density, and was reacted with hydrochloric acid to generate hydrogen. The hydrogen generation rate for the solid-state $NaBH_4$ reaction was measured at various conditions. As a result, the hydrogen generation rate was increased with the feed rate and concentration of hydrochloric acid, while not be affected by the reaction temperature. A fuel cell was connected with the solid-state $NaBH_4$ hydrogen generator. The stable power output was obtained at the gradual and sudden increases of electric loads.

Electrochemical Noise Analysis on the General Corrosion of Mild steel in Hydrochloric Acid Solution

  • Seo, Do-Soo;Lee, Kwang-Hak;Kim, Heung-Sik
    • Corrosion Science and Technology
    • /
    • v.7 no.6
    • /
    • pp.319-323
    • /
    • 2008
  • The polarization resistance of mild steel in 0.5M hydrochloric acid has been evaluated by using impedance (Z) and linear polarization (LPR) techniques and compared to the noise resistance obtained from electrochemical noise data. The degree of localization of this general corrosion has also been discussed by evaluating localization index and power spectral density. Polarization resistance obtained by LPR technique ($28\Omega$) was higher than that obtained by impedance technique ($15\Omega$). Noise resistance ($11\Omega$) was much lower than polarization resistance measured by both of above techniques. Higher polarization resistance obtained by LPR technique is generally caused by passivation effect in the presence of scales or deposits which can introduce an increased resistance as can low conductivity electrolytes. The reason why noise resistance is lower than polarization resistance is the effect of background noise detected by using three platinum electrodes cell in 0.5M hydrochloric acid. Slope($-\beta$) of power spectral density (PSD) obtained from analysis of noise data ($-\beta$ = 3.3) was much higher than 2 which indicates mild steel corroded uniformly. Localization index (LI) calculated from statistical analysis (LI=0.08) is much lower than 1 which indicates that mild steel did not corroded locally. However, LI value is still higher than $1x10^{-3}$ and this indicates that mild steel corroded locally in microscopic point of view.

Analysis of Likelihood of Failure for the Thinning of Hydrochloric Acid Corrosion through Risk-Based Inspection using API-581 BRD (API-581 절차에 의한 위험기반검사에서 염산부식의 두께감소에 의한 사고발생 가능성 해석)

  • Lee, Hern-Chang;Jo, Ji-Hoon;Shin, Dong-Il;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.4
    • /
    • pp.37-44
    • /
    • 2010
  • To propose a cause analysis method of pressurized facilities, a likelihood of failure (LOF) for the thinning module by hydrochloric acid corrosion was analyzed through the risk-based inspection (RBI) using API-581 BRD. For this investigation, the technical module subfactor (TMSF), as a main factor of the LOF, was estimated, and the effects of parameters on the TMSF were analyzed quantitatively. As a result, we found that the TMSF increased with increasing chloride ion concentration and temperature, but it decreased with increasing thickness of the facilities, inspection number and inspection effectiveness. Also, the TMSF showed a relatively low value for the monitoring system implemented and the overdesign factor>1.5. In this condition, the TMSF changed sensitively with the inspection number, the inspection effectiveness and the overdesign factor, and its magnitude varied with the monitoring system.

Studies on the Eurytrema pancreaticum (췌질(膵蛭)에 관한 연구(硏究) [III] 충란검사법(蟲卵檢査法)의 개량(改良))

  • Jang, Du Hwan
    • Korean Journal of Veterinary Research
    • /
    • v.10 no.1
    • /
    • pp.25-31
    • /
    • 1970
  • The techniques which have been used for the fecal examination of ruminant infected with the pancreatic flukes, Eurytrema Pancreaticum, were reviewer in their efficiency to detect the ova. One of modified fecal examination: H.F.E. (hydrochloric acid-formalin-ether) sedimentation method was devised in this study. Efficiency in the detecting ability of the fluke eggs with H.F.E. sedimentation method was determined by a series of repeat tests. Among 20 head of cattle known to harbor 1-5 adult worms of the pancreatic fluke, 75% of the infected cattle were detected, and among 60 head of cattle known to harbor more than 6 adult worms, 95% of the infected cattle were detected with H.F.E. sedimentation method. The procedures of the H.F.E. sedimentation method are as follows; 1) Take the sample 5-10 gm., emulsify throughly with 20 ml. of 50% hydrochloric acid in a cup. 2) Strain this mixture through one or two layers of wet surgical gauze into 15ml. centrifuge tube. 3) Washing the cup with 5ml. of 50% hydrochloric acid and strain again. 4) Centrifuge at 2,300 rpm. for 2 minutes. 5) Pour off the supernatant fluid. 6) After the sediment mixed with 10% formalin, stand for 5 minutes. 7) Add 2-3ml. of ether, shake vigorously up and down, after the top of the tube covered with thumb. 8) Centrifuge at 2,300 rpm. for 2 minutes. 9) Loosen the fecal plug in the tube by ringing with an applicator stick. 10) Quickly, but carefully, pour of all, but the bottom layer of sediment. 11) Thoroughly mix the sediment, pour on a slide (or pick up it with a pipett), mount with a cover glass. 12) Examine carefully.

  • PDF

Solvent Extraction of Co(II) and Cu(II) from Hydrochloric Acid Solution of Spent Lithium-ion Batteries Containing Li(I), Mn(II), and Ni(II) (Li(I), Mn(II) 및 Ni(II)를 함유한 폐리튬 이온 배터리의 염산침출용액에서 Co(II) 및 Cu(II)의 용매 추출)

  • Le, Minh Nhan;Lee, Man Seung
    • Resources Recycling
    • /
    • v.29 no.5
    • /
    • pp.73-80
    • /
    • 2020
  • In order to develop a process for the recovery of valuable metals from spent LiBs, solvent extraction experiments were performed to separate Cu(II) and/or Co(II) from synthetic hydrochloric acid solutions containing Li(I), Mn(II), and Ni(II). Commercial amines (Alamine 336 and Aliquat 336) were employed and the extraction behavior of the metals was investigated as a function of the concentration of HCl and extractants. The results indicate that HCl concentration affected remarkably the extraction efficiency of the metals. Only Cu(II) was selectively at 1 M HCl concentration, while both Co(II) and Cu(II) was extracted by the amines when HCl concentration was higher than 5 M, leaving the other metal ions in the raffinate. Therefore, it was possible to selectively extract either Cu(II) or Co(II)/Cu(II) by adjusting the HCl concentration.

A Study on the Correlation between Leak Hole Size, Leak Rate, and the Influence Range for Hydrochloric Acid Transport Vehicles (염산 운송차량의 누출공 크기와 누출률 및 영향범위간 상관관계 연구)

  • Jeon, Byeong-Han;Kim, Hyun-Sub
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.2
    • /
    • pp.175-181
    • /
    • 2021
  • Objectives: The correlation between the size of a leak hole, the volume of the leakage, and the range of influence was investigated for a hydrochloric acid tank-lorry. Methods: For the case of a tank-lorry chemical accident, KORA (Korea Off-site Risk Assessment Supporting Tool) was used to predict the leak rate and the range of influence according to the size of the leak hole. The correlation was studied using R. Results: As a result of analyzing the leak rate change according to the leak hole size in a 35% hydrochloric acid tank-lorry, as the size of the leak hole increased from 1 to 100 mm, the leak rate increased from 0.008 to 83.94 kg/sec, following the power function. As a result of calculating the range of influence under conditions ranging from 1 to 100 mm in size and 10 to 60 minutes of leakage time, it was found that the range spanned from a minimum of 5.4 m to a maximum of 307.9 m. As a result of multiple regression analysis using R, the quadratic function model best explained the correlation between the size of the leak hole, the leak time, and the range of influence with an adjected coefficient of determination of 0.97 and a root mean square error of 22.33. Conclusion: If a correlation database for the size of a leak hole is accumulated for various substances and under various conditions, the amount of leakage and the range of influence can easily be calculated, facilitating field response activities.

Preliminary Research on Securing the Stability of Sandy Beaches in Gyeonggi Province (경기도 해수욕장 모래의 안전성 확보를 위한 선행연구)

  • Choi, Yun-Ho;Byun, Joo-Hyeong;Won, Jong-Moo;Kim, Jong-Sung;Shin, Jong-Hyun;You, Chang-Suk;Jeong, Yun-Ha;Park, Min-Been;Oh, Jo-Gyo
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.694-701
    • /
    • 2020
  • Objectives: The main purpose of this study is to evaluate heavy metal concentrations (Cd, As, Hg, Pb, Cr6+), particle size distribution, hydrochloric acid solubility, and parasite eggs in sand in five non-designated sandy beaches in Gyeonggi Province. Methods: The sampling sites are five non-designated Gyeonggi-do sandy beaches located in Ansan and Hwaseong. ICP-OES and UV, a Vibratory Sieve Shaker, and PCM were respectively used to analyze heavy metal concentrations, particle size distribution, and parasite eggs in the sand. Results: Heavy metals were detected within the beach's safety management standards and some of the detected As and Pb before and after beach opening were lower than one-quarter of the average value. In addition, the results of the T-test to confirm the As and Pb concentration changes before and after opening showed a significant difference in some beaches. The composition of sand was 86.53% according to the particle size distribution standard (2.0-0.02 mm), and the hydrochloric acid solubility was the highest at Gubongsolsup (4.9%) and the lowest at Bangameo-li (0.2%). Parasite eggs were undetected in all beach sand before and after opening. Conclusions: The safety of heavy metal concentrations in sandy beaches was secured in the selected five beaches in Gyeonggi Province. However, continuous efforts are required to make Gyeonggi-do's beaches suitable according to the Act on the Use and Management of Beaches.

Leaching of Molybdenite by Hydrochloric Acid Solution Containing Sodium Chlorate (NaClO3를 함유한 염산용액으로 몰리브데나이트광의 침출)

  • Nguyen, Thi Nhan Hau;Nguyen, Thi Thu Huong;Lee, Man Seung
    • Resources Recycling
    • /
    • v.31 no.5
    • /
    • pp.26-33
    • /
    • 2022
  • Molybdenum is widely used in many materials; thus, its recovery from ores and secondary resources has attracted considerable attention. In this study, the leaching of molybdenite ore using hydrochloric acid containing sodium chlorate as an oxidizing agent was studied. The effects of several variables, such as the concentrations of HCl and NaClO3, reaction temperature and time, and pulp density, on the leaching of the ore were investigated. Under strong acidic and oxidizing conditions, the sulfide in the ore was dissolved as a sulfate ion, which formed gypsum with Ca(II), leading to a decrease in the leaching percentage of Mo(VI) from the ore. The leaching percentage of molybdenum was greater than 90%, while those of iron, calcium, and silicon were 38, 29, and 67%, respectively, under the optimum conditions: 2.0 M HCl, 0.5 M NaClO3, pulp density of 5 g/L, temperature of 90 ℃, and treatment time of 60 min.

Demonstration of constant nitrogen and energy amounts in pig urine under acidic conditions at room temperature and determination of the minimum amount of hydrochloric acid required for nitrogen preservation in pig urine

  • Jongkeon Kim;Bokyung Hong;Myung Ja Lee;Beob Gyun Kim
    • Animal Bioscience
    • /
    • v.36 no.3
    • /
    • pp.492-497
    • /
    • 2023
  • Objective: The objectives were to demonstrate that the nitrogen and energy in pig urine supplemented with hydrochloric acid (HCl) are not volatilized and to determine the minimum amount of HCl required for nitrogen preservation from pig urine. Methods: In Exp. 1, urine samples of 3.0 L each with 5 different nitrogen concentrations were divided into 2 groups: 1.5 L of urine added with i) 100 mL of distilled water or ii) 100 mL of 6 N HCl. The urine in open plastic containers was placed on a laboratory table at room temperature for 10 d. The weight, nitrogen concentration, and gross energy concentration of the urine samples were determined every 2 d. In Exp. 2, three urine samples with different nitrogen concentrations were added with different amounts of 6 N HCl to obtain varying pH values. All urine samples were placed on a laboratory table for 5 d followed by nitrogen analysis. Results: Nitrogen amounts in urine supplemented with distilled water decreased linearly with time, whereas those supplemented with 6 N HCl remained constant. Based on the linear broken-line analysis, nitrogen was not volatilized at a pH below 5.12 (standard error = 0.71 and p<0.01). In Exp. 3, an equation for determining the amount of 6 N HCl to preserve nitrogen in pig urine was developed: additional 6 N HCl (mL) to 100 mL of urine = 3.83×nitrogen in urine (g/100 mL)+0.71 with R2 = 0.96 and p<0.01. If 62.7 g/d of nitrogen is excreted, at least 240 mL of 6 N HCl should be added to the urine collection container. Conclusion: Nitrogen in pig urine is not volatilized at a pH below 5.12 at room temperature and the amount of 6 N HCl required for nitrogen preservation may be up to 240 mL per day for a 110-kg pig depending on urinary nitrogen excretion.

Some Effects of Acid Concentrations in Inductively Coupled Plasma Atomic Emission Spectrometry and Inductively Coupled Plasma Mass Spectrometry (유도결합 플라즈마 원자방출분광법 및 질량분석법에서 산의 농도에 의한 영향)

  • Cho, Man-Sik;Lim, Heoungbin;Kim, Young-Sang;Lee, Kwang-Woo
    • Analytical Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.277-283
    • /
    • 1992
  • Acid effects on the ICP-AES signals are studied as the concentrations of nitric acid, hydrochloric acid, sulfuric acid, and 1:1 mixture of nitric acid and hydrochloric acid are changed. Almost all analyte signals are depressed. The extent of the depression due to the pressence of the acids became to be pecular when the acid concentration was over 1%. Among the acids used, the suppression due to sulfuric acid is most severe and unexpectable. The ratios of the analyte signal to Ar signal and the Mg II signal to Mg I signal are measured as the concentration of the acids changed. In this study, it is proved that the main reason of the signal reduction is the change in the nebulization efficiency, for example, droplet size distribution, viscosity and surface tension variation, not the alteration of plasma excitation characteristics. There was no relationship found between ionization potential and analyte signal reduction in ICP-MS.

  • PDF