• Title/Summary/Keyword: Hydrochloric acid concentration

Search Result 204, Processing Time 0.027 seconds

Influence and Application of an External Variable Magnetic Field on the Aqueous HCl Solution Behavior: Experimental Study and Modelling Using the Taguchi Method (염산 수용액 거동에 대한 가변 외부 자기장의 적용과 영향: 실험 연구 및 Taguchi 법을 이용한 모델링)

  • Hashemizadeh, Abbas;Ameri, Mohammad Javad;Aminshahidy, Babak;Gholizadeh, Mostafa
    • Applied Chemistry for Engineering
    • /
    • v.29 no.2
    • /
    • pp.215-224
    • /
    • 2018
  • Influences of the magnetic field on 5, 10 and 15 wt% (1.5, 3 and 4.5 M) HCl solution behaviour, which has widespread applications in petroleum well acidizing, were investigated in various conditions. Differences in the pH of magnetized hydrochloric acid compared to that of normal hydrochloric acid were measured. Taguchi design of experimental (DoE) method were used to model effects of the magnetic field intensity, concentration, velocity and temperature of acid in addition to the elapsed time. The experimental results showed that the magnetic field decreases [$H^+$] concentration of hydrochloric acid up to 42% after magnetization. Increasing the magnetic field intensity (with 28% contribution), concentration (with 42% contribution), and velocity of acid increases the effect of magnetic treatment. The results also demonstrated that the acid magnetization was-not influenced by the fluid velocity and heating. It was also displayed that the acid preserves its magnetic memory during time. The optimum combination of factors with respect to the highest change of [$H^+$] concentration was obtained as an acid concentration of 10% and an applied magnetic field of 4,300 Gauss. Due to the reduction of HCl reaction rate under the magnetization process, it can be proposed that the magnetized HCl is a cost effective and reliable alternative retarder in the matrix acidizing of hydrocarbon (crude oil and natural gas) wells.

Analytical method of trace elements in ceramic capacitor materials (세라믹 축전물질들의 미량성분 분석방법)

  • Choi, J.K.;Kim, T.H.;Lim, H.B.
    • Analytical Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.35-42
    • /
    • 1997
  • The sample pretreatment technique using a high pressure acid digestion bomb for the analysis of ceramic capacitor materials, such as barium titanate and PZT, was studied. When the concentrations of hydrochloric acid were varied with the addition of nitric acid or distilled water, quantitative measurements for those samples were carried out using inductively coupled plasma atomic emission spectrometry. From this experiment the results indicate that most of elements, such as Ba, Mn, Zn, Si, etc., aren't affected by the concentration of hydrochloric acid but Nb and Zr are very susceptable to it. It however turns out that the digestion time relatively gave little effects on the analytical result. In case of Nb the ratio of hydrochloric acid to water should be greater than 3:1(v / v) for the best analytical result. For the Pb determination use of diluted hydrochloric acid compared to the mixture of nitric acid and hydrochloric acid showed a better analytical result.

  • PDF

A Comparative Study of Acidemia-induced Hyperkalemia and Hyperkalemia-induced Acidemia (산혈증 유발 고칼륨혈증과 고칼륨혈증 유발 산혈증의 비교 연구)

  • Yoon, Jun-Oh;Park, Choon-Ok;Hwang, Sang-Ik;Kim, Chong-Whan;Kim, Woo-Gyeum
    • The Korean Journal of Physiology
    • /
    • v.24 no.1
    • /
    • pp.123-129
    • /
    • 1990
  • A comparative study of acid-base balance has been made between acidemia-induced hyperkalemia and hyperkalemia-induced acidemia. A group of rabbits was infused 0.1 N hydrochloric acid solution and metabolic acidosis was induced. Another group was administered 20 mM potassium chloride solution and hyperkalemia was induced. The third group was infused 0.1 N hydrochloric acid and 20 mM potassium chloride solution, simultaneously. Acid-base data and plasma potassium ion concentration were monitored every thirty minutes in these three groups of rabbits. Following results were obtained: 1 ) Along with the infusion of hydrochloric acid, acute metabolic acidosis was induced in the rabbits. Plasma bicarbonate ion concentration decreased primarily in this group. As a respiratory compensation, there was a tendency of reduction of arterial $Pco_{2}$. The alteration of data became larger along with the amount of administration and the time elapsed. However, hyperkalemia was not so severe compared with the second group. 2) In potassium chloride infused group, plasma potassium ion concentration increased along with the time elapsed and the amount of infusion. And the alteration of acid-base data was parrallel to the level of potassium ion concentration, above all depression of pH was prominent. 3) Above data suggest that when acute metabolic acidosis was induced, exchange of intracellular potassium ion with extracellular hydrogen ion seems significant for the regulation of extracellular acid-base balance. And when hyperkalemia was induced with the infusion of potassium chloride solution, the exchange of intracellular hydrogen ion with extracellular potassium ion also seems significant for the regulation of extracellular potassium balance. 4) In the group of rabbits infused hydrochloric acid and potassium simultaneously, disturbances of acid-base balance and potassium balance were much more severe than two other groups. In these mixed disturbances, the process of compensatory mechanism might be inhibited and one disturbance might aggregate each other. 5) Through above data it has been postulated that in acid-base disturbance potassium balance can be sacrificed as a compensatory mechanism, and vice versa in disturbance of potassium balance. And our data also suggest that hydrogen ion and potassium ion are compensatory pair, one another.

  • PDF

Cementation of Tin by Aluminium from Hydrochloric acid Solution (염산산성(鹽酸酸性) 용액(溶液)중에서 알루미늄에 의한 주석(朱錫)의 치환반응(置換反應))

  • Ahn, Jae-Woo;So, Sun-Seob
    • Resources Recycling
    • /
    • v.17 no.2
    • /
    • pp.70-75
    • /
    • 2008
  • A study on the cementation for the recovery of tin with aluminium in the hydrochloric acid solution was carried out. Parameters, such as aluminium metal equivalent, pH, reaction time, reaction temperature and the concentration of chloride ions were investigated. The experimental results showed that the cementation rate of Sn(II) ions increased with increase of the addition amount of aluminium powders, temperature, pH and the concentration of chloride ions in hydrochloric acid solution. From the results, the optinum conditions for recovery of metallic tin by cementation with aluminium metal powders were proposed.

Electrowinning of Tin from Acidic Chloride Effluents by Cyclone type Electrolytic Cell (염산용액에서 사이클론형 전해방식에 의한 주석의 전해채취)

  • Cho, Yeon-Chul;Kang, Myeong-Sik;So, Hong-Il;Lee, Joo-Eun;Ahn, Jae-Woo
    • Resources Recycling
    • /
    • v.26 no.3
    • /
    • pp.61-68
    • /
    • 2017
  • Cyclone electrowinning method was used to recover tin to metal in hydrochloric acid solution. The effects of flow rate, current density, tin concentration, and hydrochloric acid concentration on the electrowinning of tin were investigated. As the flow rate increased and the concentration of tin and hydrochloric acid decreased, the tin recovery and current efficiency increased. As the current density increased, the recovery rate increased but the current efficiency decreased. Tin can be effectively recovered at flow rates of 18 L/min., $3A/dm^2$, 2.5 g/L Sn, and 5 wt.% HCl.

Investigating the Efficiency of Formic Acid and Hydrochloric Acid in Weak Acid Hydrolysis for Myoglobin

  • Jihyun Paek;Hyojin Hwang;Yeoseon Kim;Dabin Lee;Jeongkwon Kim
    • Mass Spectrometry Letters
    • /
    • v.14 no.2
    • /
    • pp.48-55
    • /
    • 2023
  • This study compares the efficiency of weak acid hydrolysis (WAH) using formic acid (FA) and hydrochloric acid (HCl) in the analysis of myoglobin peptides. WAH using 2% and 5% formic acid resulted in the identification of 32 peptides, with varying degrees of cleavage at the C-terminus of aspartic acid residues. HCl WAH with different concentrations demonstrated an increase in the total number of identified peptides but a decrease in fully cleaved peptides as the HCl concentration increased. Notably, deamidation was observed during HCl WAH but not in FA WAH. The addition of HCl WAH after FA WAH provided a similar pattern to HCl WAH, with slightly higher levels of hydrolysis. These findings highlight distinct cleavage patterns and deamidation effects between FA and HCl in the context of WAH.

Hydrolsis Behaviour of Antheraea pernyi Silk Fiber Treated with HCI (염산처리 작잠견사의 가수분해거동)

  • 권해용;이광길;이용우;여주홍;엄인철
    • Journal of Sericultural and Entomological Science
    • /
    • v.40 no.2
    • /
    • pp.163-168
    • /
    • 1998
  • Hydrolysis rate and activation energy of Antheraea pernyi silk fiber treated with HCI were examined. Thermal decomposition temperature and surface morphology were also investigated by using differential scanning calorimeter and scanning electron microscope. As the concentration of hydrochloric acid and the treatment temperature increased, the hydrolysis occurred more rapidly. The activation energy of Antheraea pernyi, 74.0 kJ/mol, was higher than that of Bombyx mori, 58.1 kJ/mol. As the concentration of hydrochloric acid increases, the activation energy of Antheraea pernyi decreased from 74.0 kJ/mol to 62.0 kJ/mol. The shape of acid-resistance fraction of Antheraea pernyi became more distroyed and was transformed from fiber to powdered form with an increase of hydrolysis rate. The thermal decomposition temperature of Antheraea pernyi was 360.8$^{\circ}C$ until the hydrolysis rate was 81.8 wt%, but ti decreased to 347.0$^{\circ}C$ when the hydrolysis rate was 93.8 wt%.

  • PDF

NaOH Decomposition and Hydrochloric Acid Leaching of Monazite by Hot Digestion Method (Hot digestion법(去)에 의(依)한 모나자이트정광(精鑛)의 알카리분해(分解) 및 염산침출(鹽酸浸出) 거동(擧動))

  • Kim, Sung-Don;Lee, Jin-Young;Kim, Chul-Joo;Yoon, Ho-Sung;Kim, Joon-Soo
    • Resources Recycling
    • /
    • v.19 no.6
    • /
    • pp.70-76
    • /
    • 2010
  • It was to investigate the optimum leaching conditions for the NaOH hot digestion and hydrochloric acid leaching of Monazite. The optimum condition for NaOH hot digestion was that the concentration of NaOH/TREO mole ratio was 15, the temperature of decomposition $140^{\circ}C$, and reaction time 2 hrs. And the optimum condition for the hydrochloric acid leaching of NaOH hot digestion product was that the concentration of hydrochloric acid was 6N, leaching time 2 hrs and pulp density about 15%. The yield of rare earth oxide was above 90% on the above experimental condition.

Solvent Extraction of Co(II) and Cu(II) from Hydrochloric Acid Solution of Spent Lithium-ion Batteries Containing Li(I), Mn(II), and Ni(II) (Li(I), Mn(II) 및 Ni(II)를 함유한 폐리튬 이온 배터리의 염산침출용액에서 Co(II) 및 Cu(II)의 용매 추출)

  • Le, Minh Nhan;Lee, Man Seung
    • Resources Recycling
    • /
    • v.29 no.5
    • /
    • pp.73-80
    • /
    • 2020
  • In order to develop a process for the recovery of valuable metals from spent LiBs, solvent extraction experiments were performed to separate Cu(II) and/or Co(II) from synthetic hydrochloric acid solutions containing Li(I), Mn(II), and Ni(II). Commercial amines (Alamine 336 and Aliquat 336) were employed and the extraction behavior of the metals was investigated as a function of the concentration of HCl and extractants. The results indicate that HCl concentration affected remarkably the extraction efficiency of the metals. Only Cu(II) was selectively at 1 M HCl concentration, while both Co(II) and Cu(II) was extracted by the amines when HCl concentration was higher than 5 M, leaving the other metal ions in the raffinate. Therefore, it was possible to selectively extract either Cu(II) or Co(II)/Cu(II) by adjusting the HCl concentration.

A Case of Serious Caustic Injury after Ingestion of Hydrochloric Acid (염산으로 인한 중대한 부식성 손상 1례)

  • Park Hyun-Joo;Yi Hyeon-Gyu;Kim Pum-Soo;Roh Hyung-Keun
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.2 no.1
    • /
    • pp.58-62
    • /
    • 2004
  • Acid ingestion can cause not only caustic injury on esophagus and stomach but also fatal outcome through systemic complications. We report the case of a patient who died early after severe caustic injury with strong acid. A 38-year-old man who ingested about 400ml of hydrochloric acid of unknown concentration was transferred to our hospital from a private clinic, in which he was managed with gastric irrigation through a nasogastric tube. He was complaining dyspnea and abdominal pain. Physical examination demonstrated tenderness and rebound tenderness on epigastric region. Severe metabolic acidosis and leukocytosis were noted. Radiological findings suggested perforation of gastrointestinal tract, although the physical signs were not typical. Endoscopy revealed caustic injuries of grade I on esophagus and of grade Ⅲ on stomach, which indicate more severe injury on the stomach than on the esophagus. Exploratory surgery was recommended but unfortunately not permitted by his family. Despite intensive measures, his vital signs deteriorated rapidly and he died 50 hours after the ingestion.

  • PDF