• Title/Summary/Keyword: Hydraulic conductivities

Search Result 104, Processing Time 0.029 seconds

Characteristics of the Hydraulic Conductivity of Carbonate Aquifers in Gangwon Province (강원도 탄산염지역 대수층의 수리전도도 특성)

  • Park, Young-Yun;Lee, Jin-Yong;Lim, Hong-Gyun;Park, Yu-Chul
    • The Journal of Engineering Geology
    • /
    • v.21 no.1
    • /
    • pp.79-85
    • /
    • 2011
  • We investigated the flow properties of groundwater in areas of carbonate rocks at Yeongwol and Jeongseon, Gangwon Province, based on measurements of hydraulic conductivity. Existing hydraulic conductivity data were compiled from 46 wells in the study area. These wells were sunk close to Golji stream and the Joyang and Dong rivers, which flow through the study area. The hydraulic conductivities range from 0.004 to 1.1 m/day, and show a gradually decreasing trend with decreasing well depth (y=-0.003x - 0.927, $r^2$=0.129). The study area was classified into zone A (< 0.1 m/day), zone B (0.1-1.0 m/day), and zone C (> 1 m/day) according to hydraulic conductivity. Zones A, B, and C make up 87% (n = 40), 11 % (n = 5), and 2% (n = 2) of the surface of the study area, respectively. Among the three zones, zone A contains few fractures whereas zone C contains many fractures. These results indicate that groundwater flow in carbonate regions is strongly influenced by the fracture network.

Characteristics of Bentonite Filter Cake on Vertical Cutoff Walls Evaluated by Modified Fluid Loss Test (수정 fluid loss 시험을 이용한 연직 차수벽에 생성된 벤토나이트 필터케익 특성 평가)

  • Nguyen, The-Bao;Park, Moon-Seo;Lim, Jee-Hee;Choi, Hang-Seok;Han, Shin-In
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.2
    • /
    • pp.53-62
    • /
    • 2011
  • During the construction of vertical cutoff walls, filtration of bentonite slurry into the adjacent soil formation fabricates a layer of bentonite filter cake on the wall surface. The bentonite filter cake possesses much lower hydraulic conductivity compared to that of backfill materials in the cutoff wall. Hydraulic conductivity of bentonite filter cakes formed with three different types of bentonites has been measured by performing the modified fluid loss test under various pressure levels. Three different mixture ratios, 4, 6, and 8%, were selected for fabricating bentonite filter cakes to represent common field conditions. Two analysis methods for interpreting the experimental data from the modified fluid loss tests were employed to estimate hydraulic conductivity of the bentonite cakes. The range of hydraulic conductivities of the three bentonite cakes is between $2.15{\times}10^{-11}\;m/s$ and $2.88{\times}10^{-10}\;m/s$ which is 1 to 2.7 orders of magnitude lower than that of the design cutoff wall backfill. The stress distribution and thickness of the bentonite cakes were also evaluated in this paper.

A Comparison of Soil Hydraulic Conductivities Determined by Three Different Methods in a Sandy Loam Soil (토양(土壤)의 포화투수계수(飽和透水係数) 측정법(測定法) 비교(比較) 연구(硏究))

  • Park, Moo-Eon;Yoo, Sun-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.16 no.1
    • /
    • pp.14-19
    • /
    • 1983
  • Comparison and evaluation of various wellknown methods to determine the saturated hydraulic conductivity of soil were attempted in order to choose a convenient and reliable method applicable, at least, to Bonryang sandy loam (coarse loamy over sandy, mixed, mesic family of Typic Udifluvents). Three experimental methods, inversed auger hole, infiltrometer, and core sample method, were used for this purpose. The results were summarized as follows: 1. The inversed auger hole method was highly correlated with the infiltrometer method while the core sample method was poorly correlated with other two methods. 2. The inversed auger hole method was proved to be convenient and reliable method to measure the hydraulic conductivity of upland coarse textured soils in situ. 3. The hydraulic conductivity determined by the infiltrometer method converged to a constant value after 80 to 100 minutes from starting of measurement. 4. The conductivity determined by the inversed auger hole method approached to a constant value at 5 or 6th run of measurement. 5. The hydraulic conductivity determined by the core sample method was greatly under estimated in comparison with the values obtained by other two methods.

  • PDF

Ecophysiological Interpretations on the Water Relations Parameters of Trees (XI) -The Comparison of Hydraulic Conductivity of Branch Junctions in Twenty-one Deciduous Broad-Leaved Species (수목(壽木)의 수분특성(水分特性)에 관한 생리(生理)·생태학적(生態學的) 해석(解析)(XI) - 낙엽(落葉) 활엽수(闊葉樹) 21종(種)의 분지부(分枝部)의 수분통도성(水分通道性) 비교(比較) -)

  • Han, Sang Sup;Kim, Sun Hee;Yi, Myong Jong
    • Journal of Korean Society of Forest Science
    • /
    • v.87 no.2
    • /
    • pp.220-229
    • /
    • 1998
  • This study was performed to compare the characteristics of hydraulic conductivity such as relative conductivity(RC), leaf specific conductivity(LSC), Huber value(HV), specific conductivity(SC), and diameter of vessels(${\mu}m$) and number of vessels($No./mm^2$) in branch junctions of the twenty-one deciduous broad-leaved species. The hydraulic conductivities of branch junctions decreased with increasing junction angle between stem and branch, and with decreasing diameter of branch. The RC and LSC of branch junctions related to branching types(ㅏ, Y, ${\Psi}$ type) were much lower in ㅏ and ${\Psi}$ types than in Y type. The diameter and number of vessels remarkably reduced in branch junctions as compared with the stem and branch.

  • PDF

Thermal Conductivity from an in-situ Thermal Response Test Compared with Soil and Rock Specimens under Groundwater-bearing Conditions (지하수 부존지역에서의 토질 및 암석 시료와 현장 열응답시험의 열전도도 비교)

  • Kim, Jin-Sung;Song, Sung-Ho;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.23 no.4
    • /
    • pp.389-398
    • /
    • 2013
  • Studies of the thermal properties of various rock types obtained from several locations in Korea have revealed significant differences in thermal conductivities in the thermal response test (TRT), which has been applied to the design of a ground-source heat pump system. In the present study, we aimed to compare the thermal conductivities of the samples with those obtained by TRT. The thermal conductivities of soil and rock samples were 1.32W/m-K and 2.88 W/m-K, respectively. In comparison, the measured TRT value for thermal conductivity was 3.13W/m-K, which is 10% higher than that of the rock samples. We consider that this difference may be due to groundwater flow because abundant groundwater is present in the study area and has a hydraulic conductivity of 0.01. It is natural to consider that the object of TRT is to calculate the original thermal conductivity of the ground, following the line source theory. Therefore, we conclude that the TRT applied to a domestic standing column type well is not suitable for a line source theory. To solve these problems, values of thermal conductivity measured directly from samples should be used in the design of ground-source heat pump systems.

Comparison of Disk Tension Infiltrometer and van Genuchten-Mualem Model on Estimation of Unsaturated Hydraulic Conductivity (장력 침투계(Disk Tension Infiltrometer)와 van Genuchten-Mualem 모형 적용에 따른 불포화수리 전도도의 비교 해석)

  • Hur, Seung-Oh;Jung, Kang-Ho;Park, Chan-Won;Ha, Sang-Keun;Kim, Geong-Gyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.5
    • /
    • pp.259-267
    • /
    • 2006
  • Hydraulic conductivity is the rate of water flux on hydraulic gradient. The van Genuchten Mualem (VGM) model is frequently used for describing unsaturated state of soils, that is composed with the function of soil water potential and soil water content and requests various parameters. This study is to get the value of VGM parameters used Rosetta computer program based on neural network analysis method and to calculate VGM parameters. VGM parameters included Ko(effective saturated hydraulic conductivity), ${\theta}r$(residual soil water content), ${\theta}s$(saturated soil water content), L, n and m. The unsaturated hydraulic conductivity at 10 kPa was calculated by using Rosetta program. Unsaturated hydraulic conductivities of 17 soil series at 1, 3, 5, 7 kPa were also obtained by applying saturated hydraulic conductivity by disk tension infiltrometer based on Gardner and Wooding's equation. Water flow at the water potential of 3 kPa was very low except Namgye, Hagog, Baegsan, Sangju, Seogcheon, Yesan soil series. Unsaturated hydraulic conductivity at 1 kPa showed the highest value for Samgag soil series and was in order of Yesan, Hwabong, Hagog and Baegsan soil series. Those of Gacheon, Seocheon and Ugog soil series were very low. When the value by VGM was compared with the value by disc tension infiltrometer, there was a tendency with exponential function to soils without gravel but there was no tendency to soils including gravel. Conclusively, it would be limited that VGM model for unsaturated hydraulic conductivity analysis applies to Korean agricultural land including gravel and having steep slope, shallow soil depth.

An Experimental Study on the Design Factors of Raw-water Supply System in Floodplain Filtration (홍수터여과에서 원수공급체계의 설계요소에 대한 실험연구)

  • Kim, Hoh-Seok;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.957-964
    • /
    • 2009
  • Sand tank experiments were performed along with on-site supplier experiments in order to obtain design factors for the raw-water supply system in floodplain filtration. Results of the sand tank experiment elucidated that the infiltration rate was approximately proportional to the soil permeability and was not significantly influenced by short periods of rest. The average daily infiltration rate calculated by taking both flood and rest periods into account increased with increasing flood period, and was observed to reach an asymptote. Under the conditions of this study, the maximum infiltration rates obtained for both Daegu and Mulgeum soils with 15 min/ 30 min of rest/flood periods were 6.3 m/day and 1.4 m/day respectively, which were 42% and 70% of their hydraulic conductivities, respectively. The process of soil filtration resulted in a gradual decrease of hydraulic conductivity; a decrease of 27% was observed for the soil of Mulgeum over a period of 8 days. From the data obtained from the supplier experiment, it was evident that the radius of the flooded area increased as the supply rate increased for soils of Gumi and Sangju, however, there was an inverse correlation between hydraulic conductivity and the rate of increase in the radius. Results also showed that the time required to cover the entire soil surface with water, in other words, the time to reach the maximum flood radius from the commencement of the water emission was as short as 3 to 4 minutes for all the soils. Also, the average infiltration rate for the entire flood period did not change significantly when the rest period was shorter than an hour.

Analysis of Chemical Compatibility of Leachates with Liner Materials in the Waste Landfills (폐기물 매립장의 차폐재와 침출 화학성분과의 상호작용 분석)

  • 정하익;장연수
    • Geotechnical Engineering
    • /
    • v.9 no.3
    • /
    • pp.49-60
    • /
    • 1993
  • The compatibility of chemicals in the leachates with the three natural and artificially -made liner materials is analyzed by performing the laboratory hydraulic conductivity test. The selected liner materials are natural marine clay, fly ash and weathered granitic soil stomped from Kimpo Wastefills, Seochon power plant and Mansu Dong, Inchon, respectivaly. Bentonites of 20 and 10 percent by weight are used as additive materials for fly ash and weathered granitic soil and the chemical solutions used in the test are acetic acid, methanol, heptane, and aniline which are frequently found in the leachate of waste fills. The concentrations of the chemical solutions are 100% and 75%. The results of the tests show that hydraulic conductivities of the oxter materials are increased by one or two orders of magnitude with permeating pure chemical solutions. The rate of hydraulic conductivity increase is lowest for Seochon fly ash admixed liner and highest for natural marine clay liner. The influence of hydraulic chemical solutions on the liner materials is least for acetic acid and largest for aniline. The increases of conductivity are not shown with the permeation of the solution of concentration 75%. At least by this test results, it can be recognized that the tested liner material can be quite stable with the solutions of significantly high concentration except pure solutions.

  • PDF

A Comparative Study on the REV, non-REV and Joint Network Methods for Analysis of Groundwater Flow in Jointed Rock Masses (절리암반내 지하수 유동해석을 위한 대표체적법, 비대표체적법 및 절리망 해석법의 비교 연구)

  • 문현구
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.5
    • /
    • pp.217-228
    • /
    • 1999
  • The three methods of analysis (i) REV(representative elemental volume), (ii) non-REV and (iii) joint network analysis are introduced in this paper to analyze the groundwater flow in jointed rock mass and the inflow into underground excavations. The results from those methods are compared one another to reveal their characteristics by varying the number of joints and the diameter of the opening. The pre-processor, the so-called sequential analysis, is introduced to predict the equivalent hydraulic conductivity of a jointed rock mass having a number of intersecting joints. Using the finite element mesh, joint map and sequential analysis, the equivalent hydraulic conductivities are calculated for all 445 elements. The hydraulic inhomogeneity and the determination of the representative properties of jointed rock masses are discussed. In the REV analysis where the entire rock mass is homogenized through the representative properties, the inflow is increased regularly and consistently by increasing the joint density, the opening size and the conductivity contrast value. Though the non-REV analysis showed irregular variation of the inflow due to the local inhomogeneity allowed to individual elements, the inflow approached the REV results as the characteristic length increases. The joint network analysis showed the most sensitive reaction to the joint density, the opening size and the presence of the network crossing the opening. The reliability of the network analysis depends on the geometric data of individual joints. In view of the limited field data on joint geometry and possible uncertainty the REV and non-REV methods are considered more practical and rational than the joint network analysis.

  • PDF

Study on Moye's Method for Analysis of Constant-Head Tests Conducted in Crystalline Rock (결정질 암반에서 Moye 방법을 이용한 정압시험의 해석에 대한 고찰)

  • Kyung-Woo Park;Byeong-Hak Park;Sung-Hoon Ji;Kang-Kun Lee
    • The Journal of Engineering Geology
    • /
    • v.33 no.4
    • /
    • pp.519-530
    • /
    • 2023
  • Moye's analytical solution was examined as a method for constant-head tests under steady-state conditions, and results were compared with transient-state analyses in in situ hydraulic tests. The sensitivity of hydraulic conductivities calculated using Moye's method increased with the length of the test section, which should be as large as possible under test conditions. Particularly in low-permeability media with less than 10-8 m/sec of hydraulic conductivity, hydraulic conductivity is lower than that under transient-state conditions and can be recalculated by adjusting the boundary between radial and spherical flow assumed in Moye's equation. Constant-head tests performed in the research borehole at the KAERI Underground Research Tunnel (KURT) indicated that transmissivities derived from the constant-head withdrawal test under transient-state conditions in low-permeability media were higher than those derived from steady-state tests, likely because the groundwater flow boundary was smaller than the "half of the test-section length"assumed by Moye's equation. When interpreting constant-head test results for crystalline rock, the hydrogeological properties of the medium may be better understood by considering assumed conditions accompanying analysis of the steady-state condition and comparing them with results for the transient-state analysis, rather than simply assuming properties based on steady-state analyses.