• 제목/요약/키워드: Hydraulic Turbine

검색결과 217건 처리시간 0.03초

Zwicker 파라미터를 이용한 수차발전기 소음의 음질분석 (Sound Quality Analysis of Water Turbing Generator Noise using Zwicker Parameter)

  • 국정훈;윤재현;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.273-277
    • /
    • 2007
  • In case of the Hydraulic Turbine Dynamo operating for Waterpower Generation, it makes very huge and loud noises, and it influences bad effect physically as same as mentally to those people who are working inside of power plant, and brings the decline of an effective working efficiency. However, its evaluation method or measure about such noise reflects merely its physical attribute which is sensuous Loudness of the Noise itself, since the accumulation effect of Noise or the meaning connected with psychological response did not reflect, it is the actual state that a rational evaluation is unable to expect. Consequently, this Study has attempted to evaluate the Noise of Hydraulic Turbine Dynamo by analyzing the sound quality using Zwicker‘s Psychological Acoustic Parameter, after classification by its positions of the Noise occurring at Hydraulic Turbine Dynamo.

  • PDF

준우산형 수차발전기의 수직도 자동 측정방법과 그 적용 (A Method of Automatic Plumbness Measuring for the Semi-umbrella Type Hydraulic Turbine Generator)

  • 김문영;김낙점
    • 소음진동
    • /
    • 제10권4호
    • /
    • pp.623-628
    • /
    • 2000
  • This paper presents the automatic plumbness measuring system form improving the accuracy and working time for plumbness measuring of semi-umbrella type hydraulic turbine generator. It is general practice that rotating shaft should run within acceptable vibration limit. In order to obtain more accurate measuring data for single stage shaft on the semi-umbrella type, plumbness approach must be established carefully and accurately. Generally, present plumbness procedure is required several calculation algorithm, laser sensor and data acquisition devices. As a result of application to actual new system it is confirmed that working time could be saved over 80% and accurate measurement data could be acquired.

  • PDF

Numerical prediction of pressure pulsation amplitude for different operating regimes of Francis turbine draft tubes

  • Lipej, Andrej;Jost, Dragica;Meznar, Peter;Djelic, Vesko
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권4호
    • /
    • pp.375-382
    • /
    • 2009
  • Hydraulic instability associated with pressure fluctuations is a serious problem in hydraulic machinery. Pressure fluctuations are usually a result of a strong vortex created in the centre of a flow at the outlet of a runner. At every radial turbine and also at every single regulating axial turbine, the draft tube vortex appears at part-load operating regimes. The consequences of the vortex developed in the draft tube are very unpleasant pressure pulsation, axial and radial forces and torque fluctuation as well as turbine structure vibration. The consequences of the vortex are transferred upstream and downstream with amplitude and frequency modulation in respect of the turbine operating regime, cavitation conditions and air admitted content. Numerical prediction of the vortex appearance in the design stage is a very important task. The amplitude of the pressure pulsation is different for each operating regime therefore the main goal of this research was to numerically predict pressure pulsation amplitude versus different guide vane openings and to compare the results with experimental ones. For the numerical flow analysis of a complete Francis turbine (FT), the computer code ANSYS-CFX11 has been used.

The effect of materials properties on the reliability of hydraulic turbine runners

  • Thibault, Denis;Gagnon, Martin;Godin, Stephane
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권4호
    • /
    • pp.254-263
    • /
    • 2015
  • The failure of hydraulic turbine runners is a rare event. So in order to assess the reliability of these components one cannot rely solely on the number of observed failures in a given population. However, as there is a limited number of degradation mechanisms involved, it is possible to use physically-based reliability models. Such models are often more complicated but are able to account for physical parameters in the degradation process. They can therefore help provide solutions to improve reliability. With such models, the effect of materials properties on runner reliability can be highlighted. This paper presents a brief review of the Kitagawa-Takahashi diagram which links the damage tolerance approach, based on fracture mechanics, to the stress or strain-life approaches. Using simplified response spectra based on runner stress measurements, we will show how fatigue reliability is sensitive to materials fatigue properties, namely fatigue crack propagation behaviour and fatigue limit obtained on S-N curves. Furthermore, we will review the influence of the main microstructural features observed in 13%Cr-4%Ni stainless steels commonly used for runner manufacturing. The goal is ultimately to identify the most influential microstructural features and to quantify their effect on fatigue reliability of runners.

Unstable Operation of Francis Pump-Turbine at Runaway: Rigid and Elastic Water Column Oscillation Modes

  • Nicolet, Christophe;Alligne, Sebastien;Kawkabani, Basile;Simond, Jean-Jacques;Avellan, Francois
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권4호
    • /
    • pp.324-333
    • /
    • 2009
  • This paper presents a numerical simulation study of the transient behavior of a $2{\times}340MW$ pump-turbine power plant, where the results show an unstable behavior at runaway. First, the modeling of hydraulic components based on equivalent schemes is presented. Then, the 2 pump-turbine test case is presented. The transient behavior of the power plant is simulated for a case of emergency shutdown with servomotor failure on Unit 1. Unstable operation at runaway with a period of 15 seconds is properly simulated using a 1-dimensional approach. The simulation results points out a switch after 200 seconds of the unstable behavior between a period of oscillations initially of 15 seconds to a period of oscillation of 2.16 seconds corresponding to the hydraulic circuit first natural period. The pressure fluctuations related to both the rigid and elastic water column mode are presented for oscillation mode characterization. This phenomenon is described as a switch between a rigid and an elastic water column oscillation mode. The influence of the rotating inertia on the switch phenomenon is investigated through a parametric study.

전자유압식 Governor의 개발 :화력발전소증기 turbine에 있어서의 해외논초 (Development on Governor of electronic oil pressure type for stt:am turbine of thermal power plant)

  • 대한전기학회
    • 전기의세계
    • /
    • 제17권2호
    • /
    • pp.35-37
    • /
    • 1968
  • 증기 Turbine plant의 제어방식은 점점 더 복잡하게 고도화하고 있으며 원심 또는 유압조속기등 Lever와 유압기구의 조합으로 구성된 기계유압식 Governor 대신에 전자유압식 Governor(Electro-Hydraulic Governor, EHG 일반적으로 광의의 의미로는 전자유압식제어장치 Electro-Hydraulic Control System이라함)의 개발에 주력하고 있으며 본보고서는 이에 대한 시험결과를 기술한 것이다. 본보고서는 산업용(자가발전용) 증기 Turbine의 전자유압식 Governor에 관한 것으로서 기계유압식에서의 복잡한 Lever 기구, Relay 장치등 기계부분의 전자유압화와 고압제어유의 채용및 이에 따르는 각부분의 Module화, Solid State화 및 소형 Unit화에 의하여 취급및 보수가 용이한 고성능의 제어장치를 개발하게 되었다. 특히 미국의 GE사에서 이에 대한 개발이 앞서 있으며 현재 100MW까지 약 30대가 실용화되고 있다고 한다. (이글은 일본화력발전지 1968년 1월 제136호에서 발췌한 글이다.)

  • PDF

디퓨져를 이용한 튜블러형 상반전 수차의 CFD 성능해석 (CFD Analysis of a Counter-rotating Tubular Type Micro-Turbine with Diffuser)

  • 이낙중;박지훈;황영호;김유택;이영호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.205.2-205.2
    • /
    • 2011
  • Micro hydraulic turbines take a growing interest because of its small and simple structure as well as high possibility of applying to micro and small hydropower resources. The differential pressure exiting within the city water pipelines can be used efficiently to generate electricity like the energy generated through gravitational potential energy in dams. In order to reduce water pressure at the inlet of water cleaning centers, pressure reducing valves are used widely. Therefore, pressure energy is wasted. Instead of using the pressure reduction valve, a micro counter-rotating hydraulic turbine can be replaced to get energy caused by the large differential pressure found in the city water pipelines. In this study, in order to acquire design data of counter-rotating tubular type micro-turbine, output power, head, and efficiency characteristics due to the diffuser.

  • PDF

소수력 성능향상 사례연구 (An Application Case Study of Improving Performance of Small Hydro-power)

  • 김상균;박지군;이연주
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.165.1-165.1
    • /
    • 2011
  • In this paper, it is intended to study about deferences of design and operation properties between large and small hydro-power house's turbine which type is reaction. In generally, turbine of large hydro-power has a more safe and effective energy output mechanisms than small hydro-power's because the turbine of small hydro-power is more sensitive to hydraulic losses. But, it is more effective for the all energy market to improve the capability and efficiency of small hydro-power in the present status of increasing construction of small hydro-power than large hydro-power. Therefore, we intend to investigate and introduce the way to enhance the efficiencies of reaction turbine adopted to small hydro-power.

  • PDF

일체형 입축 프로펠러수차 모형의 수력학적 성능특성 (Hydraulic Performance Characteristics of Vertical-Axis Propeller Turbine Model)

  • 박완순;이철형
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.379-382
    • /
    • 2008
  • The propeller type hydro turbine model with vertical axis has been tested and analized. The blade angle of runner of turbine model were designed to be varied according to the condition of head and flowrate. When the changes in head and output were comparatively large, the efficiency drop were small, so the efficiency characteristics and stability of the entire operating condition were maintained in good condition. These results showed that the developed model in this study will be suitable for small hydro power stations with large changes in head and load such as sewage treatment plants and agricultural reservoirs.

  • PDF

수소력발전용 입축 프로펠러 수차의 수력학적 성능특성 분석 (Hydraulic Performance of Vertical Axis Propeller Type Hydro Turbine for Small Hydropower Plants)

  • 이철형;박완순
    • 한국수소및신에너지학회논문집
    • /
    • 제14권2호
    • /
    • pp.171-176
    • /
    • 2003
  • The propeller type hydro turbine model with vertical axis has been tested and analyzed. The blade angle of turbine model were designed to be varied according to the condition of head and flowrate. When the changes in head and output were comparatively large, the efficiency drop were small, so the efficiency characteristics and stability of the entire operating condition were maintained in good condition. These results showed that the developed model in this study will be suitable for small hydro power stations with large changes in head and load such as sewage treatment plants and agricultural reservoirs.