• 제목/요약/키워드: Hydraulic Servo Control

검색결과 245건 처리시간 0.028초

압력제어용 직동 밸브를 이용한 전기.유압 서보시스템의 힘 제어 (Force Control of Electro-Hydraulic Servo System using Direct Drive Valve for Pressure Control)

  • 이창돈;이진걸
    • 유공압시스템학회논문집
    • /
    • 제1권3호
    • /
    • pp.14-19
    • /
    • 2004
  • The Direct Drive Valve used in this study contains a pressure-feedback-loop in itself, then it can eliminate nonlinearity such as the square-root-term in flow rate calculation and the change of bulk modulus of hydraulic oil. In this study, assuming that the dynamic characteristic of the DDV is modelled as a first order lag system, an parameter identification method using the input data and the output data is applied to obtain DDV's mathematical model. Then, a state feedback controller was designed to implement the force control of hydraulic system, and the control performance was evaluated.

  • PDF

제어관점에서의 부하감지형 유압시스템의 특성 (Properties of the Load-Sensing Hydraulic System from a Viewpoint of Control)

  • 김성동
    • 대한기계학회논문집
    • /
    • 제18권3호
    • /
    • pp.738-750
    • /
    • 1994
  • The load-sensing hydraulic system which was developed to improve energy efficiency of conventional hydraulic systems has its own properties. The instability of system responses, linearity of a servo valve, robustness for variation of external load, and dynamic interference between hydraulic motors are such properties which have much to do with control properties of the system. The load-sensing hydraulic system has instability tendancy because the load-sensing mechanism makes a positive feedback loop between the motor part and the pump part. A flow property of the servo valve can be said to be linear because the flow through the valve has nothing to do with a load pressure and the flow is strictly proportional to a valve opening which is adjusted by a valve command signal. The resultant control property can be said to be robust because the steady-state control performance is independent to the load actuated on the motor shaft. In the case when one pump simultaneously drives more than two hydraulic motors, the pump outlet pressure is determined by a hydraulic motor of the largest load pressure among all of the hydraulic motors, and, thus, the other motors are dominated by the largest load pressure. That is, the other motors can be said to be interfered by the motor of the largest load pressure.

가변구조제어기를 이용한 외란을 받는 유압시스템의 위치제어 (Position Control of a Hydraulic System Subjected to Disturbances Using a Variable Structure Controller)

  • 박근석;김형의
    • 제어로봇시스템학회논문지
    • /
    • 제10권10호
    • /
    • pp.915-921
    • /
    • 2004
  • In this paper, a variable structure controller(VSC) is used to control the position of the hydraulic servo system subjected to unknown disturbances. The system consists of two cylinders, which connected in series. One cylinder executes position control, the other executes force control to generate disturbances. In order to control each cylinder, interaction must be considered between two cylinders because two cylinders are connected in series. Therefore, the controller is designed regarding interaction between two cylinders as disturbances. Performance of the proposed controller was verified through experiments and compared to PID controller. The experiments showed that the proposed controller had a good performance and robustness.

헬름홀츠 감쇠기를 응용한 유압시스템의 유압맥동 및 소음 최소화 연구 (Hydraulic Pulsation and Noise Reduction using the Helmholtz Attenuator)

  • 김동현;이대옥;최근국
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.614-619
    • /
    • 1997
  • The hydraulic pressure pulsation has on the effected on the acoustic nosie and control performance of the hydraulic-servo system. The Helmholtz attenuator introduction on the hydraulic line is an efficient device to reduce the hydraulic pulsation. The salient feature of causing hydraulic pulsation and the frequency characteristics of Helmholtz attenuator are studied. The hydraulic filter design parameters such as the locating position, connecting orifice area and accumulator volume are mathematically analyzed. The instrumental works are carried out with the remarkable reduction of the hydraulic pressure pulsation magnitude and the acoustic noise level.

  • PDF

전기유압 서보시스템의 슬라이딩 모드 위치제어 (Position Control of an Electro-hydraulic Servo System with Sliding Mode)

  • 허준영
    • 드라이브 ㆍ 컨트롤
    • /
    • 제18권3호
    • /
    • pp.16-22
    • /
    • 2021
  • The variable structure controller has the characteristic that while in sliding mode, the system moves along the switching plane in the vicinity of the switching plane, so it is robust to the parameter fluctuations of the plant. However, a controller based on a variable structure may not meet the desired performance when it is commanded to track any input or exposed to disturbances. To solve this problem, a sliding mode controller based on the IVSC approach excluding an integrator is proposed in this study. The proposed sliding mode control was applied to the position control of a hydraulic cylinder piston. The sliding plane was determined by the pole placement and the control input was designed to ensure the existence of the sliding mode. The feasibility of the modeling and controller was reviewed by comparing it with a conventional proportional control through computer simulation using MATLAB software and experiment in the presence of significant plant parameter fluctuations and disturbances.

AC유도전동기 서보제어장치를 이용한 구조물 슬라이딩공법 (A Study on Improvement of Structural Sliding Method Using AC Induction Motor Servo Control Device)

  • 조영남;한재웅;장원태
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2018년도 추계학술대회
    • /
    • pp.235-237
    • /
    • 2018
  • 구조물 건축분야에서의 슬라이딩 공법의 우수성에도 불구하고 유압식 동력제어 방식의 문제점을 개선하기 위하여 AC 유도전동기 서보제어장치를 구조물 건축 분야의 동력제어기술로 활용함으로서 정밀제어 및 생산성 향상에 기여 할 수 있다. Induction Motor Servo Controller를 기반으로 PC와 MITY(MS) Servo의 복잡한 조합을 이용한 이동성슬라이딩 공법 시스템 개발을 제안 하였다.

  • PDF

압축가스 방출 유압시스템 해석 및 제어 (The Analysis and Control of Compressed Gas Discharging System)

  • 장웅락;김정관;한명철;정찬희;박인기
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.458-462
    • /
    • 2004
  • The hydraulic system for discharging compressed gas is composed of compressor tank, proportional flow control servo valve, expulsion spool valve and discharging tube. Purpose of this study is to control of expulsion spool valve. First, we analyzed the hydraulic system. The flow control servo valve is modeled as a 2nd order transfer function and friction force of the expulsion spool valve is modeled as nonlinear model with stribeck effect. However, it is difficult to include the flow reaction force in modeling. So, we exchanged from the simplified flow reaction force of the compressed gas affection into the flow analysis code written in FORTRAN code. Our simulation of the oil pressure system for discharging gas used MATLAB/Simulink. So, we realized 'Level -2 S-Function Fortran' to cooperate for MATLAB/Simulink and FORTRAN code. PD controller is selected to control in this system. Simulation results show that with given conditions the controllers give a good tracking performance.

  • PDF

유압 서보 제어계에서 밸브 선형화 방정식의 오차 평가 (Error Evaluation of the Linearized Equation of Servo Valve in Hydraulic Control Systems)

  • 김태형;이일영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.501-506
    • /
    • 2001
  • In the procedure of the hydraulic control system analysis, a linearized approximate equation described by the first order term of Taylor's series has been widely used. Such a linearized equation is effective just near the operating point. In this study, the authors estimate computational errors in the process of applying the existing linearized equation stated above. For evaluating the computational accuracy in practical applications of the linearized equations, dynamic behaviors of hydraulic control systems are investigated through simulations with several kinds of representative hydraulic systems and the linearized equations suggested in this study.

  • PDF

무인 컨테이너 운반차량의 조향을 위한 전기-유압 시스템의 안정도 분석 및 해석 (Stability Analysis and Control of the Electro-Hydraul System for Steering of the Unmaned Container Transporter(UCT))

  • 최재영;윤영진;허남;이영진;이만형
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1999년도 추계학술대회논문집
    • /
    • pp.371-374
    • /
    • 1999
  • This paper present the nonlinear control and the Lyapunov analysis of the nonlinear electro-hydraulic system for steering control of UCT. Electro-hydraulic system itself has the high nonlinearities arisen from the nonlinear characteristics of the pressure-fluid flow in valve and friction in cylinder. These nonlinearities are unmodeled terms in the transfer function. This paper presents the system modeling, analysis of stability based on the Lyapunov function and simulation of the nonlinear hydraulic servo system.

  • PDF

전기-유압 서어보 시스템의 시간-지연 제어기 설계 (Time-Delayed Feedback Controller Design for a Electro-Hydraulic Servo System)

  • 김수홍;원상철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.342-345
    • /
    • 1989
  • In this paper, a controller design for a electro-hydraulic servo system is presented. When state variables of the system are not directly measurable for feedback control, it is very difficult to satisfy the given requirements for the system output control. The proposed design method is based on the feeding back of the output variable and it's time delayed values.

  • PDF