• 제목/요약/키워드: Hydraulic Factor

검색결과 499건 처리시간 0.022초

테이프와 거칠기가 설치된 사각 채널의 압력강하 특성 (Characteristics of Pressure Drops in Square Channels with Twisted Tape Inserts plus Axial Interrupted Ribs)

  • 안수환;배성택;강호근
    • 동력기계공학회지
    • /
    • 제10권4호
    • /
    • pp.38-42
    • /
    • 2006
  • Pressure drops and friction factors in square channels with twisted tape inserts plus axial interrupted ribs are investigated. Tests are performed for Reynolds numbers ranging from 8,900 to 29,000. The rib height-to-channel hydraulic diameter, $e/D_h$, is kept at 0.057 and test section length-to-hydraulic diameter, $L/D_h$ is 30. The pressure drops and friction factor values are enhanced with axial interrupted ribs and twisted tape inserts. Square channels with twisted tape inserts plus axial interrupted ribs show the greatest pressure loss penalty in the present work. Friction factor data obtained for the square channel with twisted tape inserts plus axial interrupted ribs are less than those in the past publications for circular tubes with axial interrupted ribs and twisted tape inserts.

  • PDF

Numerical investigations on the effect of tortuosity on friction factor in superconducting CICC configuration

  • Vaghela, Hitensinh;Lakhera, Vikas;Bhatt, Kunal;Sarkar, Biswanath
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.49-55
    • /
    • 2021
  • The Cable in Conduit Conductor (CICC) configurations are designed, tested and realized to make high field superconducting (SC) magnets. The evolution of CICC design makes it challenging to forecast thermo-hydraulic behavior. A common objective of thermo-hydraulic studies is to obtain the most reliable predictive correlation for friction factor in CICC geometries and to reduce the dependency on the experiment. So far, only the void fraction and Reynolds number have been considered in the predictive correlations in an explicit way. In the present paper, the CICC twisting pattern dependency, called tortuosity (τ), on the pressure drop prediction, has been assessed through a numerical simulation approach. The CICC twisting pattern with 6+1 petals (solid conductor in the present study) with different twisting pitches is mimicked in the numerical simulation for the range 100 ≤ Re ≤10000 and 1 < τ < 1.08 and a correlation for friction factor, f, has been proposed as a function of Re and τ.

강우침투에 따른 불포화 토사사면의 안정해석 (Slope Stability Analysis of Unsaturated Soil Slopes Due to Rainfall Infiltration)

  • 조성은;이승래
    • 한국지반공학회논문집
    • /
    • 제16권1호
    • /
    • pp.51-64
    • /
    • 2000
  • 본 연구는 강우의 침투로 인한 불포화 토사사면의 안정 해석을 위한 절차를 제시한다. 강우 침투로 인한 사면의 거동은 흐름과 변형이 연관된 이차원 유한요소해석을 통하여 해석된다. 시간에 따른 안전율을 계산하기 위하여 유한요소 해석법을 통한 응력장(stress field)으로부터 가상활동면에 대한 안전율을 산정할 수 있도록 하는 정교한 응력적분기법을 적용하였고 기하학적으로 허용가능한 활동단면의 형상을 유지하면서 합리적으로 임계단면을 찾아가는 최적화방법을 적용함으로써 강우에 의한 토사사면의 안정성 평가 절차를 개발하였다. 또한 이를 이용하여 강우침투시 투수계수의 공간적인 변화가 불포화토사사면의 파괴 거동에 미치는 영향을 보다 공학적이고 합리적인 방법으로 연구하였다. 연구결과에 의하면 투수계수의 불균질한 분포로 인하여 강우에 의한 사면표면의 국부적인 파괴영역이 발생할 수 있고 이러한 영역이 점점 확대되어 전체적인 파괴에 이르게 된다. 그러므로 시간의존적 인 사면안정해석 문제의 경우 이러한 국부적인 파괴 영역의 영향을 더 이상 무시할 수 없다.

  • PDF

CORE AND SUB-CHANNEL EVALUATION OF A THERMAL SCWR

  • Liu, Xiao-Jing;Cheng, Xu
    • Nuclear Engineering and Technology
    • /
    • 제41권5호
    • /
    • pp.677-690
    • /
    • 2009
  • A previous study demonstrated that the two-row fuel assembly has much more favorable neutron-physical and thermal-hydraulic behavior than the conventional one-row fuel assemblies. Based on the newly developed two-row fuel assembly, an SCWR core is proposed and analyzed. The performance of the proposed core is investigated with 3-D coupled neutron-physical and thermal-hydraulic calculations. During the coupling procedure, the thermal-hydraulic behavior is analyzed using a sub-channel analysis code and the neutron-physical performance is computed with a 3-D diffusion code. This paper presents the main results achieved thus far related to the distribution of some neutronic and thermal-hydraulic parameters. It shows that with adjustment of the coolant and moderator mass flow in different assemblies, promising neutron-physical and thermal-hydraulic behavior of the SCWR core is achieved. A sensitivity study of the heat transfer correlation is also performed. Since the pin power in fuel assemblies can be non-uniform, a sub-channel analysis is necessary in order to investigate the detailed distribution of thermal-hydraulic parameters in the hottest fuel assembly. The sub-channel analysis is performed based on the bundle averaged parameters obtained with the core analysis. With the sub-channel analysis approach, more precise evaluation of the hot channel factor and maximum cladding surface temperature can be achieved. The difference in the results obtained with both the sub-channel analysis and the fuel assembly homogenized method confirms the importance of the sub-channel analysis.

피에조 액츄에이터 적용 고압 인젝터의 유압 동특성 해석 (Analysis of Hydraulic Characteristics of High Pressure Injector with Piezo Actuator)

  • 이진욱;민경덕
    • 한국자동차공학회논문집
    • /
    • 제14권4호
    • /
    • pp.164-173
    • /
    • 2006
  • In the electro-hydraulic injector for the common rail Diesel fuel injection system, the injection nozzle is being opened and closed by movement of a injector's needle which is balanced by pressure at the nozzle seat and at the needle control chamber, at the opposite end of the needle. In this study, the piezo actuator was considered as a prime movers in high pressure Diesel injector. Namely a piezo-driven Diesel injector, as a new method driven by piezoelectric energy, has been applied with a purpose to develop the analysis model of the piezo actuator to predict the dynamics characteristics of the hydraulic component(injector) by using the AMESim code. Aimed at simulating the hydraulic behavior of the piezo-driven injector, the circuit model has been developed and verified by comparison with the experimental results. As this research results, we found that the input voltage exerted on piezo stack is the dominant factor which affects on the initial needle behavior of piezo-driven injector than the hydraulic force generated by the constant injection pressure. Also we know the piezo-driven injector has more degrees of freedom in controlling the injection rate with the high pressure than a solenoid-driven injector.

스털링 엔진용 재생 열교환기의 다공체 구조에 따른 성능 특성 (Performance Characteristics of a Regenerative Heat Exchanger Depending on Its Porous Structure)

  • 신명철;안준;강병하
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.415-421
    • /
    • 2012
  • Stirling engine is an external combustion engine, whose efficiency approaches that of Carnot engine with the help of a regenerator. The regenerator is a heat exchanger composed of porous medium, whose performance is dependent on the pore structure. Three types of pore structures are considered in the present study. They are wire screen, random wire and composite structure, i.e. a combination of wire screens with different hydraulic diameters. The porosity more highly affects the performance of a regenerator compared to the hydraulic diameter. The random wire can yield high effectiveness even at a high porosity. The composite mesh gives better performance when the hydraulic diameter decreases in the direction from hot side to cold side.

누수성 프락탈 대수층내의 일정 또는 다단계 양수시험의 민감성 분석에 의한 수리상수 결정 (Hydraulic Parameter Evaluation by Sensitivity Analysis of Constant and Variable Rate Pump Test in Leaky Fractal Aquifer)

  • 함세영
    • 지질공학
    • /
    • 제4권3호
    • /
    • pp.311-319
    • /
    • 1994
  • 본 논문은 누수를 포함하는 프락탈 대수층의 수리상수의 최적값을 구하기 위한 민감성 분석에 대한 것이다. 민감성 분석은 최소자승법을 이용한다. 민감성 분석에 의하여 수리상수(일반화 투수량계수와 일반화 저유계수)는 여러가지 흐름의 차원과 여러 값의 누수계수에 대해서 쉽게 결정될 수 있다. 아울러, 민감성, 분석은 다수의 양수정의 다단계 양수에도 적용되었다. 민감성 분석을 이용한 프락탈 대수층의 수리상수 산출을 위하여 컴퓨터 프로그램이 개발되었다.

  • PDF

휠 로더용 폐회로형 부하 감응 유압 제어 시스템의 특성 해석 (The Characteristic Analysis of the Load-sensitive Hydraulic Control System for Closed Center Type of a Wheel Loader)

  • 이승현;송창섭;정춘국
    • 대한기계학회논문집A
    • /
    • 제31권9호
    • /
    • pp.934-942
    • /
    • 2007
  • In this study, the characteristics of the load-sensitive hydraulic control system for closed center type of a wheel loader were analyzed using developed analysis program based on Amesim tool. From the parametric analysis, the effects of each factor were revealed. Through the simulation with varying parameters, the system parameter effects on the controllable region and the pump pressure and load pressure variations were studied. The results were compared with the experimental ones. The results and discussions of the present paper could aid in the design of a load-sensitive hydraulic control system for closed center type.

소형 굴삭기용 브리드 오프 센터형 유압 제어 시스템의 특성 (The Characteristic of the Hydraulic Control System with Bleed-off Center Type of a Compact Excavator)

  • 김준식;이승현;이재원
    • 대한기계학회논문집A
    • /
    • 제32권2호
    • /
    • pp.119-126
    • /
    • 2008
  • In this study, the characteristics of the hydraulic control system with bleed-off center type of a compact excavator were analyzed using developed analysis program. From the parametric analysis, the effects of each factor were revealed. Through the simulation with varying parameters, the system parameter effects on the controllable region and the pump pressure and load pressure variations were studied. The results were compared with the experimental ones. The results and discussions of the present paper could aid in the performance improvement of a hydraulic control system of a compact excavator.

뉴로-퍼지 제어기를 이용한 유압서보시스템의 추적제어 (A Tracking Control of the Hydraulic Servo System Using the Neuro-Fuzzy Controller)

  • 박근석;임준영;강이석
    • 제어로봇시스템학회논문지
    • /
    • 제7권6호
    • /
    • pp.509-517
    • /
    • 2001
  • To deal with non-linearities and time-varying characteristics of hydraulic systems, in this paper, the neuro-fuzzy controller has been introduced. This controller does not require and accurate mathematical model for the nonlinear factor. In order to solve general fuzzy inference problems, the input membership function and fuzzy reasoning rules are used for determining the controller parameters. These parameters are determined by using the learning algorithm. The control performance of the neuro-fuzzy controller is evaluated through a series of experiments for the various types of inputs while applying disturbances to the hydraulic system. The performance of this controller was compared with those of PID and PD controllers. From these results, We observe be said that the position tracking performance of neuro-fuzzy is better those of PID and PD controllers.

  • PDF