• 제목/요약/키워드: Hydraulic Control Valve

검색결과 411건 처리시간 0.026초

원자력발전소 유출계통의 과도현상에 대한 연구 (A Study on Hydraulic Transients of Letdown System of Nuclear Power Plant)

  • 김민;정장규;김은기;노태선;이성노;유성연
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.493-498
    • /
    • 2002
  • The letdown system of pressurized water reactor (PWR) nuclear fewer plants had experienced instabilities in letdown system due to unacceptable flow characteristics of control valves. The Korean Standard Nuclear Power Plants (KSNPs) have three flow paths in parallel for letdown new control. Each flow path consists of two offices and one isolation valve. This study evaluates the effect of orifice arrangement and valve stroke time of letdown isolation valve on the system transients because sudden flow changes due to valve actuation can generate high pressure peaks in letdown line. A pressure transient analysis has been preformed to evaluate the impact of dynamic transients. This analysis uses MMS which is a simulation code developed by EPRI based on the method of characteristics. The result shows that the pressure peak is reduced in the continuous arrangement but negligible. Additionally, it shows that the stroke time of linear type flog valve greater than 15 seconds can give more stable performance.

  • PDF

보조 동력장치용 서보밸브 유효 오리피스 면적의 칼만필터 추정 (Kalman Filter Estimation of the Servo Valve Effective Orifice Area for a Auxiliary Power Unit)

  • 장지팡;김춘택;정헌술
    • 유공압시스템학회논문집
    • /
    • 제4권4호
    • /
    • pp.1-7
    • /
    • 2007
  • Flow rate is one of the important variables for precise motion control and detection of the faults and fluid loss in many hydraulic components and systems. But in many cases, it is not easy to measure it directly. The orifice area of a servo valve by which the fluid flows is one of key factors to monitor the flow rate. In this paper, we have constructed an estimation algorithm for the effective orifice area by using the model of a servo valve cylinder control system and Kalman filter algorithm. Without geometry information about the servo valve, it is shown that the effective orifice area can be estimated by using only displacement and pressure data corrupted with noise. And the effect of the biased sensor data and system parameter errors on the estimation results are discussed. The paper reveals that sensor calibration is important in accurate estimation and plausible parameter data such as oil bulk modulus and actuator volume are acceptable for the estimation without any error. The estimation algorithm can be used as an useful tool for detecting leakage, monitoring malfunction and/or degradation of the system performance.

  • PDF

절자 비례 밸브를 갖는 펌프의 퍼지-동력제어기 설계 (Design of Fuzzy-Power Controller for a Pump with Electric Proportional Valve)

  • 전순용
    • 제어로봇시스템학회논문지
    • /
    • 제4권4호
    • /
    • pp.441-447
    • /
    • 1998
  • Motivated by a recent work, a fuzzy-power-controller(FPC) is designed for the relieving-horsepower control of output variable pump with electrical proportional valve and actually implemented on the industrial excavator. In order to calculate the output power of pump with input of FPC, a linear discrete time model of load system to pump is obtained and the result is applied to control the engine-pump coupled system by software without pressure and flow sensor. The FPC controls the engine and pump coupled system by relieving horsepower control according to the change of load and the running conditions in relieving horsepower control are selected by fuzzy inference engine. A case study is peformed through the construction of the control device and installation on the excavator. It shows that the relieving-horsepower control system with the FPC, as suggested in this paper, is superior to the conventional PID controllers. And also, the excavator, with the FPC, shows that the power-loss of the coupled system is reduced and the running speed of the hydraulic actuator is enhanced.

  • PDF

전자 유압식 후륜 조향 장치의 응답 특성 개선에 관한 연구 (A Study on the Improvement of the Response Characteristic of the Electro-Hydraulic Rear Wheel Steering Gear)

  • 오인호;양경욱;이일영
    • 한국자동차공학회논문집
    • /
    • 제5권6호
    • /
    • pp.192-201
    • /
    • 1997
  • The feedback control scheme of the pressure control system of the rear wheel steering gear which has relatively large volume and sprung load was built up in order to improve th response characteristic of the system. The control algorithm chosen was a feedback compensator joined by a feedfoward compensator and the model matching method was used in the process of control system design. The structures and properties of the reference models were inspected and the parameters of the controller were decided. The improvement of the response characteristic of the pressure control valve by means of the feedback control is affirmed. Particularly, when the order of the system model is higher than the 2nd order, the effectiveness of the feedback control on the improvement of the response characteristic of the valve is distinct. And the convenience of the model matching method is the process of control system design is confirmed as well.

  • PDF

유량제어밸브 인가신호 형태가 선형펌프 방식 수중사출 시스템의 성능에 미치는 영향에 관한 수치적 연구 (Effect of Command Signal of Flow Control Valve on Performance of Underwater Discharge System using Linear Pump - Numerical Investigation)

  • 이선주;최원식
    • 한국군사과학기술학회지
    • /
    • 제24권2호
    • /
    • pp.219-227
    • /
    • 2021
  • In the present study, the effect of command signals of the flow control valve on performance of underwater discharge systems using a linear pump was investigated numerically. For that, the improved mathematical model was developed. The improvement is to calculate the flow leakage between the water cylinder and the piston. Also the model of the hydraulic cylinder is simplified. To validate the improved model, calculation results were compared with experiment results. The results of the study is as follows: Double ramp command signals of the flow control valve had an advantage over single ramp signals. The parametric study on the effect of double ramp command signals on performance of the system was performed. In case of using double ramp signals, the maximum acceleration of the underwater vehicle was reduced by approximately 50 % compared with using single ramp signals.

적응제어 기법을 이용한 전기-유압 액츄에이터의 위치제어 (Position Control of an Electro Hydraulic Actuator Using Adaptive Control Method)

  • 조승호
    • 유공압시스템학회논문집
    • /
    • 제7권3호
    • /
    • pp.1-6
    • /
    • 2010
  • This paper deals with the issue of simple adaptive position control for a pump-controlled cylinder system. A fixed displacement pump is utilized instead of servo valve and its speed is controlled by AC motor. The whole control system is composed of a pair of interconnected subsystems, that is, a feedback control system and a feedforward control system. From experiments it is shown that position control using simple adaptive control can accomplish significant reduction in position tracking error comparing to a conventional PID control.

  • PDF

소형 연근해 어선의 조업 시스템 개선에 관한 연구-II -원격 조타 시스템의 설계- (Improved Design in Fishing Operation System for Small Inshore and Coastal Fishing Vessels -II -Design of a Remote Steering System-)

  • 이대재
    • 수산해양기술연구
    • /
    • 제36권1호
    • /
    • pp.25-32
    • /
    • 2000
  • A combination steering system was designed to provide the flexibility in controlling the steering wheel in fishing operations of the inshore and coastal fishing vessels. The designed steering system basically is consisted of three driving units, such as a electrically driven hydraulic pump unit with a solenoid control valve, a DC motor driven hydraulic pump unit and a manually driven hydraulic pump unit, and two controllers to provide remote steering on the deck, respectively. The steering torque was measured and analyzed to investigate the dynamic performance of the developed steering system. The steering system showed excellent linearity between the working pressure of cylinder and the torque of rudder post in case of increasing in rudder angle from $5^{\circ} to 35^{\circ}$ that is, the steering torque increased from $10.4 kgf{\cdot}m$ to $105.3 kgf{\cdot}m$ and then the working pressure of cylinder fluctuated from 6.3 kgf/cm super(2) to 16.4 kgf/cm super(2). The steering time of 3.2 sec in remote hydraulic steering by the on/off solenoid valve control was much faster than 13.2 sec in the manual steering by the helmsman and 11.6 sec in the electric steering by a DC motor, and then it was verified that operation of one unit does not affect other units in combination steering system in any way. Furthermore, the developed steering system can be remotely controlled in multiple stations of the deck during the fishing operation and the automatic pilot steering unit can be used to add hydraulic steering.

  • PDF

Vibration Control of an Axially Moving String: Inclusion of the Dynamics of Electro Hydraulic Servo System

  • Kim, Chang-Won;Hong, Keum-Shik;Kim, Yong-Shik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.342-347
    • /
    • 2003
  • In this paper, an active vibration control of a translating tensioned string with the use of an electro-hydraulic servo mechanism at the right boundary is investigated. The dynamics of the moving strip is modeled as a string with tension by using Hamilton’s principle for the systems with changing mass. The control objective is to suppress the transverse vibrations of the strip via boundary control. A right boundary control law in the form of current input to the servo valve based upon the Lyapunov’s second method is derived. It is revealed that a time-varying boundary force and a suitable passive damping at the right boundary can successfully suppress the transverse vibrations. The exponential stability of the closed loop system is proved. The effectiveness of the control laws proposed is demonstrated via simulations.

  • PDF

유압 위치제어 시스템의 단속적 제어방법에 관한 연구 I

  • 장효환;안병홍;이춘호
    • 대한기계학회논문집
    • /
    • 제11권3호
    • /
    • pp.465-472
    • /
    • 1987
  • 본 연구에서는 솔레노이드 밸브를 사용한 유압위치제어 시스템에 위에서 언급 한 두가지 단속적 제어 방법을 적용하여 각각의 제어변수들과 부하조건이 시스템의 시 간 영역에서의 응답특성에 미치는 영향을 실험적으로 규명하고 각각의 제어특성을 비 교 고찰하였다.

미끄럼 방지 제동장치용 솔레노이드 밸브의 모델링에 관한 연구 (A Study on the Modeling of Solenoid Valve for Anti - lock Brake System)

  • 송창섭;양해정
    • 한국정밀공학회지
    • /
    • 제12권12호
    • /
    • pp.81-90
    • /
    • 1995
  • Anti-lock Brake System has been developed to reduce tendency for wheel lock and improve vehicle control during sudden braking on slippery road surfaces. This is achieved by controlling the braking pressure avoiding wheel lock, while retaining handling and brake performance. This paper is concerned about characteristics of a solenoid valve in hydraulic modulator for controlling brake pressure. First, it was modeling the electromagnet by the permeance method. Second, it was modeling the commercial Maxwell poackage program. And then, a experiment was performed in order to justify modeling. The result of modeling coincided with teh result of experiment and commercial packabe program. As a result, these modelings will be able to use in analysis of dynamic character- istics of the solenoid valve for braking.

  • PDF